inspectionsINSPECTION WORKSHEET (FM-000742-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-0782-2018 Case Module:Permit
Inspection Date:Mon Feb 4, 2019 Inspection Status:Passed
Inspector:Gary Stillman Inspection Type:OCC-Inspections
Job Address:Parcel Number:63 QUAKER RD
Queensbury, NY 12804
296.18-1-5
Contact Type Company Name Name
Granted Permission 63 Quaker LLC Fiacco, Michael
Contractor J & P Builders
Primary Owner 63 Quaker LLC Fiacco, Michael
Applicant Fiacco, Michael
Checklist Item Passed Comments
Fire Marshal YES NEED EMER CONTACT FORM
Exit Access YES
Exit Enclosure YES
Exit Discharge YES
Locks and Latches YES
Sign: Normal YES
Sign: Backup YES
Feb 04, 2019 Page (1)
INSPECTION WORKSHEET (FM-000742-2019)
Checklist Item Passed Comments
Main Aisle Width YES
Secondary Aisle Width YES
Fire Extinguisher Hung YES
Inspection of Extinguisher YES
Emergency Lighting Interior YES Ok
Clearance to Electrical YES
Electrical Wiring Enclosed/Labeled YES Ok
Combustibles in Equipment Rooms YES
F.D. Signage YES
Storage YES
Interior Finishes YES REPLACE CEILING TILE AS DISCUSSED
2/4/19 CORRECTED
CO Detectors YES Ok
Clearance to Sprinkler/Ceiling YES
Occupancy Cycle YES B
Feb 04, 2019 Page (2)
Stillman, Gary (Inspector)
INSPECTION WORKSHEET (BINS-000406-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0782-2018Permit
Case Number:Case Module:
Thu Jan 17, 2019Failed
Inspection Date:Inspection Status:
John O'BrienCommercial Final Inspection
Inspector:Inspection Type:
63 QUAKER RD296.18-1-5
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
Granted Permission63 Quaker LLC
Primary Owner63 Quaker LLC
ApplicantFiacco, Michael
ContractorJ & P Builders
Checklist ItemPassedComments
Blower Door Test CertificationNO
Chimney / B Vent / Direct Vent LocationNO
Chimney Rain Cap InstalledNO
Wood deck: 2'+ from grade dia bracing required -NO
H/C ramp compliant
Int/Ext Guardrails 42 inch Platform DecksNO
Int/Ext Balusters 4 inch Spacing Platform DecksNO
Stair rail 34 in - 38 in Step Risers 7 Treads 11NO
Jan 17, 2019Page (1)
INSPECTION WORKSHEET (BINS-000406-2019)
Checklist ItemPassedComments
Gas Shut-off Exposed & Regulator (18) AboveNO
Grade
Backflow Preventors where requiredNO
Outside Spigots have Air GapNO
Boiler/Furnace Enclosurer Fire Ext SystemNO
Low Water Shut Off for BoilersNO
HVAC Vent Terminal 10' from Lot Line &NO
Openings
Oil Furnace Shut-Off at Entrance to Furnace AreaNO
Propane Tank: Proper Setback from PropNO
Line/Struct
Stockroom /Storage/Receiving/Shipping RoomNO
¾ Hour Corridor Doors & ClosersNO
Firewalls, 2 Hr, 3 Hr / Fire Dampers / Fire DoorsNO
Ceiling Fire Stopping, 3,000 sq. ft. Wood FrameNO
Attic Access 30 x 20 x 30 (h)NO
Attic Access GasketedNO
Attic Access Insulation = Attic R- ValueNO
Jan 17, 2019Page (2)
INSPECTION WORKSHEET (BINS-000406-2019)
Checklist ItemPassedComments
Smoke Vents Or Fan, if requiredNO
Hydraulic Elevators: Non-comb. PlumbingNO
REQUIRED
Hydraulic Elevators: Oil Seperator REQUIREDNO
Elevator Operation and Signage Shaft SealedNO
H/C Bathroom Grab Bars /Sinks/Toilets/MirrorsNO- Lower mirrors so bottom of mirror is 40" max from floor.
Handicapped RampsNO
Ramps: 6" or more need handrailsNO
Ramps: 4" toe kick each side of rampNO
Ramps: 12" extension top & bottomNO
Handicapped UnitsNO
Active Listening System and Signage AssemblyNO
Space
Bollard Protection:4' on ctr/3' abv grd, gas meterNO
Bollard Protection: 15" footings & 3' below gradeNO
Occupancy sensor lighting controlNO- Install occupancy sensor switches in bathrooms
CSST/other piping in conduit if buried,if requiredNO
Jan 17, 2019Page (3)
INSPECTION WORKSHEET (BINS-000406-2019)
Checklist ItemPassedComments
Site Plan Variance requiredNO
Final SurveyNO
As-built Septic System Layout RequiredNO
Public Sewer Sign-OffNO
Bldg Num or Tenant Address on Bld or DriveNO- Install 4" high suite number or letter above door.
Water Fountain or CoolerNO
HRV or ERV Installed per Bedroom RequirementsNO
Engineer or Architect ApprovalNO
Elevator Hoistways PressurizedNO
Special InspectionsNO- Provide HVAC Air Balancing Report
OK to Issue Temporary C/ONO1/17/19 Final Inspection Not Approved
- Provide HVAC Air Balancing Report
- Install 4" high suite number or letter above door.
- Install occupancy sensor switches in bathrooms
- Lower mirrors so bottom of mirror is 40" max from floor.
- Install ceiling tiles that are out.
- Complete Fire Marshal's Items
OK to Issue C/ONO
Okay To Issue CCNO
O'Brien, John (Inspector)
Jan 17, 2019Page (4)
INSPECTION WORKSHEET (RPLUM-000404-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0782-2018Permit
Case Number:Case Module:
Thu Jan 17, 2019Passed
Inspection Date:Inspection Status:
John O'BrienRough Plumbing
Inspector:Inspection Type:
63 QUAKER RD296.18-1-5
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
Primary Owner63 Quaker LLC
Granted Permission63 Quaker LLC
ApplicantFiacco, Michael
ContractorJ & P Builders
Checklist ItemPassedComments
Building Inspector NotesYES12/20/18 Plumbing Under Slab Not Approved
- Not Ready for pressure test. Reschedule for 10- 12
tomorrow
1/17/19 Plumbing Approved
Plumbing Under SlabYES12/20/18 Plumbing Under Slab Not Approved
- Not Ready for pressure test. Reschedule for 10- 12
tomorrow
12/21/18 under slab ok to cover, need to inspect and
pressure test all above slab plumbing
Rough Plumbing / Nail PlatesYES1/17/19 Plumbing Approved
Plumbing Vent Vents in PlaceYESVerified holding pressure 12/31/18
Jan 17, 2019Page (1)
INSPECTION WORKSHEET (RPLUM-000404-2019)
Checklist ItemPassedComments
5 psi or 10 ft. above highest conn. for 15 minutesYES12/31/18
Pressure TestYES12/21/18 underslab only
O'Brien, John (Inspector)
Jan 17, 2019Page (2)
INSPECTION WORKSHEET (FIST-000403-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0782-2018Permit
Case Number:Case Module:
Thu Jan 17, 2019Passed
Inspection Date:Inspection Status:
John O'BrienFirestopping
Inspector:Inspection Type:
63 QUAKER RD296.18-1-5
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
Primary Owner63 Quaker LLC
Granted Permission63 Quaker LLC
ApplicantFiacco, Michael
ContractorJ & P Builders
Checklist ItemPassedComments
Building Inspector NotesYES1/17/19 Firestopping Approved - A&A side only
Fire separation 1, 2, 3 hourYES1/10/19 separation wall look good, need to stuff and seal
double joist in space and leave ceiling tile below out
1/17/19 Firestopping Approved - A&A side only
O'Brien, John (Inspector)
Jan 17, 2019Page (1)
INSPECTION WORKSHEET (BINS-000402-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0782-2018Permit
Case Number:Case Module:
Thu Jan 17, 2019Voided
Inspection Date:Inspection Status:
John O'BrienBuilding Framing
Inspector:Inspection Type:
63 QUAKER RD296.18-1-5
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
Granted Permission63 Quaker LLC
Primary Owner63 Quaker LLC
ApplicantFiacco, Michael
ContractorJ & P Builders
Checklist ItemPassedComments
Building Inspector NotesNO
FramingNOPartial only for partion wall 12/31/18
Attic Access 22 x 30 minimumNO
Jack Studs HeadersNO
Continuous Header for Garage Doors withNO
Straping
Truss Specification ProvidedNO
Bracing BridgingNO
Jan 17, 2019Page (1)
INSPECTION WORKSHEET (BINS-000402-2019)
Checklist ItemPassedComments
Hurricane Clips/Uplift Screws/Nail Holes FilledNO
Air Seal all Plates and SillsNO
Air Seal All Registers at FloorNO
Air Sealing all Joints Before InsulationNO
Joist hangersNO
Jack Posts Main BeamsNO
Exterior sheeting nailed properlyNO
12 O.C.NO
Headroom 6 ft. 8 in.NO
Notches Holes Bearing WallsNO
Metal Strapping for Notches Top PlateNO
Draft stopping 1,000 sq. ft. floor trussesNO
Anchor Bolts 6 ft. or less on centerNO
Ice and water shield 24 inches from wallNO
Soffits-Insulation BaffelNO
Windows Habitable Space BedroomsNO
Jan 17, 2019Page (2)
INSPECTION WORKSHEET (BINS-000402-2019)
Checklist ItemPassedComments
24 in. (H)NO
20 in. (W)NO
5.7 sf above below gradeNO
5.0 sf gradeNO
Design Professional Sign-off, if requiredNO
O'Brien, John (Inspector)
Jan 17, 2019Page (3)
INSPECTION WORKSHEET (RPLUM-008946-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0782-2018Permit
Case Number:Case Module:
Thu Dec 20, 2018Failed
Inspection Date:Inspection Status:
John O'BrienRough Plumbing
Inspector:Inspection Type:
63 QUAKER RD296.18-1-5
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantFiacco, Michael
Granted Permission63 Quaker LLC
ContractorJ & P Builders
Primary Owner63 Quaker LLC
Checklist ItemPassedComments
Building Inspector NotesNO12/20/18 Plumbing Under Slab Not Approved
- Not Ready for pressure test. Reschedule for 10- 12
tomorrow
Plumbing Under SlabNO12/20/18 Plumbing Under Slab Not Approved
- Not Ready for pressure test. Reschedule for 10- 12
tomorrow
Rough Plumbing / Nail PlatesNO
Plumbing Vent Vents in PlaceNO
3" Vent Through RoofNO
1 ½ inch minimum Drain SizeNO
Dec 20, 2018Page (1)
INSPECTION WORKSHEET (RPLUM-008946-2018)
Checklist ItemPassedComments
Washing Machine Drain 2 inch minimumNO
Washing Machine Trap: 18"-24" dischargeNO
Cleanout every 100 feet change of directionNO
Pressure TestNO
Drain VentNO
Air HeadNO
5 psi or 10 ft. above highest conn. for 15 minutesNO
Pressure TestNO
Water Supply PipingNO
Air HeadNO
50 P.S.I for 15 minutesNO
Air Test Gas Piping 10 psi for 10 MinutesNO
All Return Air Hard Duct WorkNO
Duct Insulation - if required in unheated spacesNO
Duct Testing Outside Conditioned SpaceNO
Duct work sealed properlyNO
O'Brien, John (Inspector)
Dec 20, 2018Page (2)
pc _ r a _
kPbArchitecture ,
P.O. Box 697 DEC 12 2018 ig
Clifton Park, NY 12065
518.429.8093 TOWN OF QUEENSBURY
BUILDING&CODES
kbuff@kpbarchitecture.com - — -m
Date: December 12, 2018
Re: 63 Quaker Ave—A&A Beauty and Benjamin Moore Fit-Out
ADDENDUM NUMBER 1
This Addendum forms a part of the Contract Documents and modifies/clarifies the original Drawings
dated December 10, 2018.
Comment from John O'Brien per voicemail on December 12, 2018
1. Submit 2015 COMcheck for Mechanical
Response: 2015 COMcheck for Mechanical cannot be completed because the existing roof top
unit (Carrier Model#48TME007-501) does not meet the required minimum of 11.00 EER for the
proposed system.The RTU was installed 8-10 years ago and the product data on the equipment
shows an EER of 10.1.The unit does have a motorized economizer with a minimum adjustable
setpoint to allow for fresh air intake and exhaust.
END OF ADDENDUM NUMBER 1 �p ARcy
Please contact me should you have any questions. �� Q �RfCk6 )F
Keith P. Buff,AIA
518.429.8093
5 I LE COPY