Loading...
CC-0768-2018 �^ TOWN OF QUEENSBURY a y � 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 --__ Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-0768-2018 Date Issued: Thursday, May 9, 2019 This is to certify that work requested to be done as shown by Permit Number CC-0768-2018 has been completed. Tax Map Number: 288.-1-53 Location: 1415 State Rte 9 Owner: Northway Outlets, LLC, Gap Inc Applicant: Expedite Permit This structure may be occupied as a: Commercial Alterations 12,285 s.f. Tenant: Old Navy By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve theproperty owner owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Desco Professional Builders Inc 288.-1-53 CC-0768-2018 Permission is hereby granted to: Tax Map No: Permit Number: For property located at: In the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Owner Address: Retail-Mercantile - Alteration Total Value Type of Construction $165,000.00 $165,000.00 1415 State Rte 9 2 Folsom ST San Fransisco, CA 94105 Gap IncOwner Name: Contractor or Builder's Name / Address Electrical Inspection Agency Desco Professional Builders Inc 290 Somers RD Ellington, CT 06029 Plans & Specifications Commercial Alterations 12,285 s.f. Tenant: Old Navy PERMIT FEE PAID - THIS PERMIT EXPIRES:$3,685.50 Thursday, December 19, 2019 (If a longer period is required, an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury;Wednesday, December 19, 2018 SIGNED BY:for the Town of Queensbury. Director of Building & Code Enforcement ________________________________ Office Use Only ADDITION/ALTERATION PERMIT Permit#: C� ` 7�O1(el) APPLICATION Permit Fee:$ (own of Clu,xnsbur% 742 Bay Road,Queensbury,NY 12804 Invoice#: P:518-761-8256 www.queensburv.net I`}i 5 Project Location„. tate Route 9 Ste#100 Lake George, NY 12845 >✓A^ Tax Map ID #: "2-66 • - ( - 5-5 Subdivision at Lake George Subdivision Name: 9 CONTACT INFORMATION: • Applicant: Name(s): Amanda Horst Mailing Address, C/S/Z: 176 E Highland Ave Cell Phone: ( 352 )978-8237 Land Line: (407 ) 469-5599 x 353 Email: amanda.horst@expeditepermit.com • Primary Owner(s): Name(s): Gap, Inc. Mailing Address, C/S/Z: 2 Folsom Street San Fransisco, CA 94105 Cell Phone: ( ) Land Line: ( 407 ) 378-6682 Email: rECEEIVIED • Contractor(s):TBD � , . ..� Business Name: 2018 Contact Name(s): Mailing Address, C/S/Z: TOWN QF QUEENSBURY Cell Phone: ) Land Li e: UII- IN GOD'E Email: • Architect(s)/Engineer(s): Business Name: Sargenti Architects Contact Name(s): Kristen Lombardo Mailing Address, C/S/Z: 461 From Road Paramus, NJ 07652 Cell Phone: ( )_ Land Line: ( Email:amanda.horst@expeditepermit.com Contact Person for Building & Code Compliance:Amanda Horst Cell Phone: ( 352 ) 978-82.37 Land Line: ( 407 ) 469-5599 x 2 Email: amanda.horstAexpeditepermit.com Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 PROJECT INFORMATION: TYPE: X Commercial Residential WORK CLASS: Single-Family Two-Family Multi-Family(#of units Townhouse Business Office X Retail _ Industrial/Warehouse _Garage (#of cars ) _Other (describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 12,285 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total square feet: Total square feet: 12,285 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 165,000 2. If Commercial project, what is the proposed use: Mercantile 3. Source of Heat (circle one): Gas Oil Propane Solar Other Fireplaces need a separate Fuel Burning Appliances & Chimney Application 4. Are there any structures not shown on the plot plan? YES NO Explain: 5. Are there any easements on the property? YES NO 6. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? Existing to Remain b. Is this a corner lot? YES NO c. Will the grade be changed as a result of the construction? YES NO d. What is the water source? PUBLIC PRIVATE WELL e. Is the parcel on SEWER or a PRIVA 'TIC system? No Town of Queensbury Budding&Code Enforcement Addition/Alteration Application Revised March 2018 r DECLARATION: I. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Amanda t SIGNATUR : DATE: 12/3/2018 Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 INSPECTION WORKSHEET (RPLUM-001491-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0768-2018 Case Module:Permit Inspection Date:Mon Mar 18, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Rough Plumbing Job Address:Parcel Number:1415 State Rte 9 Lake George, NY 12845 288.-1-53 Contact Type Company Name Name Granted Permission Desco Professional Builders Inc Contractor Desco Professional Builders Inc Primary Owner Gap Inc Property Owner Northway Outlets, LLC Architect Sargenti Architects Applicant Expedite Permit Checklist Item Passed Comments Building Inspector Notes NO 3/1/19 Plumbing Under Slab Approved - 10' pressure head test 3/18/19 Plumbing Partial Approval - Sanitary Head Test Approved - Water Head Test Approved Remaining Items: - Seal Balance of Ductwork Plumbing Under Slab YES 3/1/19 Plumbing Under Slab Approved - 10' pressure head Test Mar 18, 2019 Page (1) INSPECTION WORKSHEET (RPLUM-001491-2019) Checklist Item Passed Comments Rough Plumbing / Nail Plates YES 3/1/19 Plumbing Under Slab Approved - 10' pressure head test 3/18/19 Plumbing Partial Approval - Sanitary Head Test Approved - Water Head Test Approved Remaining Items: - Seal Balance of Ductwork Pressure Test YES 3/1/19 Plumbing Under Slab Approved - 10' pressure head Test Air Head YES 3/1/19 Plumbing Under Slab Approved - 10' pressure head Test 3/18/19 Head Test Air Head YES 3/18/19 Head Test Duct work sealed properly NO Mar 18, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (FIST-001490-2019) Case Number:CC-0768-2018 Case Module:Permit Inspection Date:Mon Mar 18, 2019 Inspection Status:Partial Pass Inspector:(null) (null)Inspection Type:Firestopping Job Address:Parcel Number:1415 State Rte 9 Lake George, NY 12845 288.-1-53 Contact Type Company Name Name Contractor Desco Professional Builders Inc Property Owner Northway Outlets, LLC Granted Permission Desco Professional Builders Inc Primary Owner Gap Inc Applicant Expedite Permit Architect Sargenti Architects Checklist Item Passed Comments Building Inspector Notes NO 3/18/19 Fire Separation Partial Approval - Tenant Fire Separation Wall - Area of fire separation wall behind soffit in northwest corner of Old Navy space. Fire separation 1, 2, 3 hour NO 3/18/19 Fire Separation Partial Approval - Tenant Fire Separation Wall - Area of fire separation wall behind soffit in northwest corner of Old Navy space. Fire wall 2, 3, 4 hour NO Fireproofing NO Mar 18, 2019 Page (1) INSPECTION WORKSHEET (FIST-001490-2019) Checklist Item Passed Comments Firestopping NO Draft stopping 1,000 sq. ft. floor trusses NO Penetration sealed NO 16 inch insulation in cavity min.NO Garage Fire Separation NO House side ½ inch or 58 inch Type X NO Garage side 5/8 inch Type X NO Ceilingwall NO Mar 18, 2019 Page (2) (null), (null) (Inspector) INSPECTION WORKSHEET (RPLUM-001215-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0768-2018 Case Module:Permit Inspection Date:Fri Mar 1, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Rough Plumbing Job Address:Parcel Number:1415 State Rte 9 Lake George, NY 12845 288.-1-53 Contact Type Company Name Name Contractor Desco Professional Builders Inc Property Owner Northway Outlets, LLC Primary Owner Gap Inc Granted Permission Desco Professional Builders Inc Architect Sargenti Architects Applicant Expedite Permit Checklist Item Passed Comments Building Inspector Notes NO 3/1/19 Plumbing Under Slab Approved - 10' pressure head test Plumbing Under Slab YES 3/1/19 Plumbing Under Slab Approved - 10' pressure head Test Rough Plumbing / Nail Plates NO Plumbing Vent Vents in Place NO 3" Vent Through Roof NO Mar 01, 2019 Page (1) INSPECTION WORKSHEET (RPLUM-001215-2019) Checklist Item Passed Comments 1 ½ inch minimum Drain Size NO Shower liner test (2" of water)NO Washing Machine Drain 2 inch minimum NO Washing Machine Trap: 18"-24" discharge NO Pressure Test NO 3/1/19 Plumbing Under Slab Approved - 10' pressure head Test Drain Vent NO Air Head NO 3/1/19 Plumbing Under Slab Approved - 10' pressure head Test 5 psi or 10 ft. above highest conn. for 15 minutes NO Pressure Test NO Water Supply Piping NO Air Head NO 50 P.S.I for 15 minutes NO Air Test Gas Piping 10 psi for 10 Minutes NO All Return Air Hard Duct Work NO Duct Insulation - if required in unheated spaces NO Mar 01, 2019 Page (2) INSPECTION WORKSHEET (RPLUM-001215-2019) Checklist Item Passed Comments Duct Testing Outside Conditioned Space NO Duct work sealed properly NO Mar 01, 2019 Page (3) O'Brien, John (Inspector) COMcheck Software Version Interior Lighting Compliance Certificate o vi IIIco CO (V t0 CV- I . O Project Information 9 O Energy Code: 2015 IECC FILE COPY o cn Project Title: Old Navy-Outlets at Lake George p Project Type: Alteration O) N CD .4..', a Construction Site: Owner/Agent: Designer/Contractor: Ir 1424 State Route 9 GAP Inc M-Engineering CD (13 Suite 100 (West Building) Store Development 750 Brooksedge Blvd M > 'V Lake George, NY 12845 2 Folsom St Westerville, OH 43081 N > 16 San Francisco, CA 94105 614.839.4639 ' tC (I) E REVIEWED FOR Ahatfield@mengineering.us.com � Z Lo CO — E ENERGY CODE COMPLIANCE NON- 0 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Sales(Retail:Sales Area) 9329 1.59 14833 Allowance: Furniture,clothing,cosmetics highlighting/Fix. ID: D9W 9329(a) 1.40 13061 (b) 2-Storage(Common Space Types:Storage>=1000 sq.ft.) 1638 0.63 1032 3-Fitting Rooms(Retail:Dressing/Fitting Room) 632 0.71 449 4-Corridor(Common Space Types.Corridor/Transition<8 ft wide) 147 0.66 97 5-Restrooms(Common Space Types:Restrooms) 158 0.98 155 6-Office(Common Space Types:Office-Enclosed) 102 1.11 113 7-Water Heater Room(Common Space Types:Electrical/Mechanical) 57 0.95 54 Supplemental Allowed Watts(null)= 500 Total Allowed Watts= 30294 (a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified. (b)Allowance is(B x C)or the actual wattage of the fixtures given in Proposed Power section,whichever is less. (c) Supplemental watts must be associated with retail merchandise highlighting fixtures. Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Sales( Retail:Sales Area 9329 sq.ft.) Track lighting 1: D9W:Current Limiting Panel: Wattage based on circuit breaker capacity(126 0 0 15120 15120 amps x 120 volts) Linear Fluorescent 1: F1-8U: Fluorescent:48"T8 32W(Super T8):Electronic: 2 51 57 2907 Linear Fluorescent 1 copy 1:F1-4U:Fluorescent:48"T8 32W(Super T8): Electronic: 1 22 37 814 Linear Fluorescent 1 copy 1:F18ASY: Fluorescent:48"T8 32W(Super T8). Electronic: 2 35 57 1995 LED 1: P18:Pendant:LED PAR 10W: 1 15 10 150 Linear Fluorescent 4: L-EM: Fluorescent:48"T8 HO 44W:Electronic: 1 16 44 704 Storage(Common Space Types:Storage >=1000 sq.ft. 1638 sq.ft.) Linear Fluorescent 1 copy 1:F2-8W: Fluorescent:48"T8 32W(Super T8): Electronic: 4 19 111 2109 Linear Fluorescent 1 copy 2:F2-4W: Fluorescent:48"T8 32W(Super T8): Electronic: 4 3 111 333 LED 1 copy 1: P17:Pendant: LED PAR 10W: 1 15 10 150 Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance - Elec (2015 IECC).cck Page 1 of 6 A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Fitting Rooms(Retail:Dressing/Fitting Room 632 sq.ft.. LED 1 copy 2:P18:Pendant: LED PAR 10W: 1 4 10 40 Linear Fluorescent 1 copy 1:F1-8U: Fluorescent:48"T8 32W(Super T8): Electronic: 2 7 57 399 Linear Fluorescent 1 copy 2:F1A-4: Fluorescent:48"T8 32W(Super T8): Electronic: 1 14 37 518 Corridor(Common Space Types:Corridor/Transition<8 ft wide 147 sq.ft.) LED 4: R9: Recessed:Other: 1 5 29 145 Restrooms(Common Space Types:Restrooms 158 sq.ft.) LED 4 copy 1:R9: Recessed:Other: 1 4 29 116 LED 1 copy 3:P17:Sconce: LED PAR lOW: 1 4 10 40 Office(Common Space Types:Office-Enclosed 102 sa.ft.) Linear Fluorescent 4 copy 1:F5: Fluorescent:48"T8 HO 44W: Electronic: 1 2 44 88 Water Heater Room (Common Space Types:Electrical/Mechanical 57 sa.ft.) Incandescent 1: S2:Surface Mounted:Other: 1 1 660 660 Total Proposed Watts= 26288 Interior Li tin PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Adam Hatfield - Designer � - 2018-12-07 Name -Title Signature Date of Ne t Q; <' 1 }r e,Q,•k ; /444 j ;!• ( eP tI► I,, : , Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance - Elec (2015 IECC).cck Page 2 of 6 • COMcheck Software Version 4.0.8.1 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be Location on plans/spec: E13-0/E13-1 determined for the interior lighting ['Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: 1 ;High Impact(Tier 1) 12 jMedium Impact(Tier 2) 3 Low Impact(Tier 3) . Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance- Elec (2015 IECC).cck Page 3 of 6 Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID - C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met. [EL15]1 reduce the lighting load by at least ❑Does Not 50%. Location on plans/spec: E1-1 ONot Observable ONot Applicable C405.2.1 :Occupancy sensors installed in DComplies Requirement will be met. [EL18]1 'required spaces. ❑Does Not ONot Observable Location on plans/spec: E1-1 O Not Applicable C405.2.1, Independent lighting controls installed DComplies Requirement will be met. C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and. Location on plans/spec: E1-1 [EL23]2 visible to occupants. Not Observable ONot Applicable C405.2.2. Automatic controls to shut off all DComplies :Requirement will be met. 1 building lighting installed in all ❑Does Not [EL22]2 buildings. ONot Observable Location on plans/spec: E9-3 O Not Applicable C405.2.3 Daylight zones provided with DComplies :Exception: Requirement does not apply. [EL16]2 individual controls that control the ❑Does Not lights independent of general area lighting. Not Observable ONot Applicable C405.2.3, ;Primary sidelighted areas are DComplies Exception: Requirement does not apply. C405.2.3. equipped with required lighting ❑Does Not 1, controls, ONot Observable C405.2.3. 2 ONot Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area DComplies Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors ❑Does Not 1, :are equipped with required lighting C405.2.3. :controls. ONot Observable 3 ONot Applicable [EL21]1 C405.2.4 Separate lighting control devices for DComplies Requirement will be met. [EL4]1 specific uses installed per approved ❑Does Not lighting plans. Location on plans/spec: E1-1 ONot Observable ONot Applicable C405.2.4 Additional interior lighting power OComplies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is Location on plans/spec: E1-1 automatically controlled and ❑Not Observable :separated from general lighting. ONot Applicable C405.3 !Exit signs do not exceed 5 watts per .DComplies Requirement will be met. [EL6]1 face. DDoes Not ONot Observable'Location on plans/spec: E4-0 ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance-Elec (2015 IECC).cck Page 4 of 6 Section Final Inspection Complies? Comments/Assumptions & Req.ID • C303.3, Furnished O&M instructions for ❑Complies Requirement will be met. C408.2.5. systems and equipment to the ElDoes Not 2 building owner or designated [F117]3 representative. ❑Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts ❑Not Observable are less than or equal to allowed ❑Not Applicable watts. C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met. 1 electric power systems within 90 days ElDoes Not [F116]3 of system acceptance. ['Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [FI33]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) ( 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance - Elec (2015 IECC).cck Page 5 of 6 y • M-Engineering RE: Old Navy Outlets of Lake George#100 1415 State Route 9 Queensbury, NY To: John O'Brien JohnO@queensbury.net Code Enforcement Officer Town of Queensbury Ph 518-761-8255 December 11, 2018 Dr. Mr. O'Brien, Please see below in response to your comments dated December 6, 2018 1. Submit a COMcheck Compliance Report for Mechanicals & Lighting based on the 2015 IECC for Queensbury, NY Climate Zone 6. a. Response: Please see updated E0-2 and 8 1/2"x11" sheets with 2015 IECC COMcheck energy code for lighting. RTU unit is existing to remain from 2014 2. Revise mechanical drawings M4-0 & M4-1 design load calculations for Queensbury NY Climate Zone 6. The drawings show Albany NY which is in a different climate zone. a. Response: Please see updated M4-1 sheet with design load calculations for Queensbury NY, RTU is existing to remain. 3. Submit the name of the company who will be performing and submitting the HVAC Balancing Report. a. Melink shall be performing the TAB at the end of HVAC installation. Please let us know if you have any additional questions or concerns. Regards, Rachael Dorothy, PE rdorothy@mengineering.us.com 614-423.3954 direct 614-839-4639 x 3257 Structural • Mechanical • Electrical • Technology 750 Brooksedge Boulevard, Westerville, Ohio 43081 • 614-839-4639 614-839-2222 Fax • www.mengineering.us.com CC .r S R E SAGENTI December 13, 2018 To: Gary K Stillman I Deputy Fire Marshal From: Sargenti Architects—Kristen Lombardo RE: Old Navy—Outlets at Lake George Response to Fire Comments received 12/07/18 Mr. Stillman, Confirming receipt of your fire comments received on 12/07/18. Once a GC is awarded for this project, we will ensure they receive the information and provide you with fire alarm drawings prior to completing any fire alarm work. Should you have any questions, please do not hesitate to contact me directly. Sincerely, Kristen Lombardo Sr. Project manager Page 1 of 1 T.973.253.9393 461 From Road,Second Floor,Paramus,NJ 07652 www.sargarch.com FIRE MARSHAL'S OFFICE eat Town of Queensbury 111 742 Bay Road, Queensbury, Q eensbury, NY 12804 4111111. " Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Old Navy #482 1415 State Route 9, #100 CC-0768-2018 12/07/2018 The following comments are based on review of the submitted plans: 1) Fire Extinguisher locations per plan to be verified, signage will be required. 2) Locks / latches shall comply with the 2015 International Fire Code. 3) Carbon monoxide detection will be required Per NYS part 1228- 4) Exit/Emergency lights appear adequate; all breakers shall be properly labeled noting emergency light circuits. A function test will be required prior to CO. 5) Provide NFPA 13 letter from sprinkler contractor. 6) Provide Fire Alarm plans/specs from Fire Alarm contractor, same contractor to provide NFPA 72 Inspection & Completion report. A function test will be required prior to CO. 7) Provide a new key for the Plaza Knox Box. Deputy Fire Marshal Gary K. Stillman 742 Bay Road Queensbury NY 12804 518 761 8205 garys@queensbury.net Fire Marshal 's Office • Phone: 518-761-8206 • Fax: 518-745-4437 fireniarshal@queensbury.net • www.queensbury.net e COMc1 eck Software Version 4.0.8.1 rift co Y Interior Lighting Compliance Certificate NLO vi 00 CN FILE COPY o 0 Project Information RECIEll \VE DEC 1 1 2O18I ! V � w Energy Code: 2015 IECC L ____I V N C Project Title: Old Navy-Outlets at Lake George i OWN o � � +-, O F Project Type: Alteration BUILDING& CODES Cn 0 Construction Site: Owner/Agent: Designer/Contractor: _ 1424 State Route 9 GAP Inc M-Engineering N ,R1 CI +-i U Suite 100(West Building) Store Development 750 Brooksedge Blvd Lake George, NY 12845 2 Folsom St Westerville, OH 43081 hA ? a) San Francisco,CA 94105 614.839.4639 V"' Z co U) Ahatfield@mengineering.us.com LC) E REVIEWED FOR COO 0 Allowed Interior Lighting Power ENERGY CODE COMPLIANCE A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Sales(Retail:Sales Area) 9329 1.59 14833 Allowance:Furniture,clothing,cosmetics highlighting/Fix.ID:D9W 9329(a) 1.40 13061 (b) 2-Storage(Common Space Types:Storage>=1000 sq.ft.) 1638 0.63 1032 3-Fitting Rooms(Retail:Dressing/Fitting Room) 632 0.71 449 4-Corridor(Common Space Types:Corridor/Transition<8 ft wide) 147 0.66 97 5-Restrooms(Common Space Types:Restrooms) 158 0.98 155 6-Office(Common Space Types:Office-Endosed) 102 1.11 113 7-Water Heater Room(Common Space Types:Electrical/Mechanical) 57 0.95 54 Supplemental Allowed Watts(null)= 500 Total Allowed Watts= 30294 (a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified. (b)Allowance is(B x C)or the actual wattage of the fixtures given in Proposed Power section,whichever is less. (c)Supplemental watts must be associated with retail merchandise highlighting fixtures. Proposed Interior Lighting Power A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Sales(Retail:Sales Area 9329 sq.ft.) Track lighting 1:D9W:Current Limiting Panel: Wattage based on circuit breaker capacity(126 0 0 15120 15120 amps x 120 volts) Linear Fluorescent 1:F1-8U:Fluorescent:48"T8 32W(Super T8):Electronic: 2 51 57 2907 Linear Fluorescent 1 copy 1:F1-4U:Fluorescent:48"T8 32W(Super T8):Electronic: 1 22 37 814 Linear Fluorescent 1 copy 1:F18ASY:Fluorescent:48"T8 32W(Super T8):Electronic: 2 35 57 1995 LED 1:P18:Pendant:LED PAR 10W: 1 15 10 150 Linear Fluorescent 4:L-EM:Fluorescent:48"T8 HO 44W:Electronic: 1 16 44 704 Storage(Common Space Types:Storage>=1000 sq.ft. 1638 sq.ft.) Linear Fluorescent 1 copy 1:F2-8W:Fluorescent:48"T8 32W(Super T8):Electronic: 4 19 111 2109 Linear Fluorescent 1 copy 2:F2-4W:Fluorescent:48"T8 32W(Super T8):Electronic: 4 3 111 333 LED 1 copy 1:P17:Pendant:LED PAR 10W: 1 15 10 150 Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance-Elec (2015 IECC).cck Page 1 of 6 A B C D E Fixture ID: Description 1 Lamp 1 Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Fitting Rooms(Retail:Dressing/Fitting Room 632 sq.ft.) LED 1 copy 2:P18:Pendant:LED PAR 10W: 1 4 10 40 Linear Fluorescent 1 copy 1:F1-8U:Fluorescent:48"T8 32W(Super T8):Electronic: 2 7 57 399 Linear Fluorescent 1 copy 2:F1A-4:Fluorescent:48"T8 32W(Super T8):Electronic: 1 14 37 518 Corridor(Common Space Types:Corridor/Transition<8 ft wide 147 sq.ft.) LED 4:R9:Recessed:Other: 1 5 29 145 Restrooms(Common Space Types:Restrooms 158 sq.ft.) LED 4 copy 1:R9:Recessed:Other: 1 4 29 116 LED 1 copy 3:P17:Sconce:LED PAR 10W: 1 4 10 40 Office(Common Space Types:Office-Enclosed 102 sq.ft.) Linear Fluorescent 4 copy 1:F5:Fluorescent:48"T8 HO 44W:Electronic: 1 2 44 88 Water Heater Room(Common Space Types:Electrical/Mechanical 57 sq.ft.) Incandescent 1:S2:Surface Mounted:Other: 1 1 660 660 Total Proposed Watts= 26288 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Adam Hatfield - Designer --- 2018-12-07 Name-Title Signature Date Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance-Elec(2015 IECC).cck Page 2 of 6 CONicheck Software Version 4.0.8.1 Inspection Checklist ,(1111,1f1 Energy Code: 2015 1ECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section " I * Plan Review Complies? i Crents/Ass+ ptions &Req-ID t I, C103.2 Plans,specifications, and/or ❑Complies Requirement will be met. [PRO calculations provide all information ODoes Not i with which compliance can be Location on plans/spec: E13-0/E13-1 y determined for the interior lighting [Not Observable ( and electrical systems and equipment Not Applicable i and document where exceptions to the standard are claimed. Information provided should include interior , lighting power calculations,wattage of ; bulbs and ballasts,transformers and II control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 1IMedium Impact(Tier 2) 13 ILow Impact(Tier 3) Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance- Elec (2015 IECC).cck Page 3 of 6 Section , # s Rough-In Electrical Inspection Complies? Comments/Assumptions &Req.ID C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met. (EL1511 reduce the lighting load by at least ❑Does Not 50%. Location on plans/spec: E1-i ['Not Observable ❑Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies Requirement will be met. [EL18]1 required spaces. ❑Does Not ENot Observable Location on plans/spec: E1-1 ❑Not Applicable C405,2.1, Independent lighting controls installed ❑Complies Requirement will be met. IC405.2.2. per approved lighting plans and all ❑Does Not k3 manual controls readily accessible and Location on plans/spec: E1-i {[EL23]2 visible to occupants. ❑Not Observable ❑Not Applicable C405,2.2. Automatic controls to shut off all ❑Complies Requirement will be met. 1 building lighting installed in all EDoes Not [EL22]2 buildings. Location on plans/spec: E9-3 ❑Not Observable d ❑Not Applicable C405,2.3 Daylight zones provided with ❑Complies Exception: Requirement does not apply. ?[EL16]2 individual controls that control the ❑Does Not lights independent of general area ❑Not Observable t lighting. ❑Not Applicable C405.2.3, Primary sidelighted areas are ❑Complies Exception: Requirement does not apply. C405.2.3. equipped with required lighting ❑Does Not 1, controls. [Not Observable ,C405.2.3.4 5.2.3. 2 ❑Not Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area ❑Complies Exception:Requirement does not apply. C405.2.3. under skylights and rooftop monitors ❑Does Not 11, are equipped with required lighting [Not Observable C405.2.3. controls. 13 ['Not Applicable I[EL21]1 I C405.2.4 Separate lighting control devices for ❑Complies Requirement will be met. t[EL4)1 specific uses installed per approved ❑Does Not lighting plans. Location on plans/spec: El-1 ❑Not Observable ❑Not Applicable 'C405.2.4 Additional interior lighting power ❑Complies Requirement will be met. i[EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is Location on plans/spec: E1-i automatically controlled and ❑Not Observable separated from general lighting. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met. j 'IEL6]1 face. ❑Does Not h Location on plans/spec: E4-0 1 ❑Not Observable u ❑Not Applicable Additional Comments/Assumptions: 1'High Impact(Tier 1) 2 (,Medium Impact(Tier 2) 3 !!Low Impact(Tier 3) Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance-Elec (2015 IECC).cck Page 4 of 6 Section # Final Inspection Complies? Comments/Assumptions &Req-ID C303.3, Furnished O&M instructions for ❑Complies Requirement will be met. C408.2.5. systems and equipment to the ElDoes Not 2 building owner or designated '[F117]3 representative. ❑Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting ❑Not Observable plans, demonstrating proposed watts e are less than or equal to allowed ❑Not Applicable watts. C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met. ,1 electric power systems within 90 days ❑Does Not a[FI16]3 of system acceptance. ❑Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [FI33]1 ensure proper calibration,adjustment, ❑Does Not programming, and operation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 iHigh Impact(Tier 1) ji 2 jlMedium Impact(Tier 2) 1; 3 !!,Low Impact(Tier 3) 11 Project Title: Old Navy-Outlets at Lake George Report date: 12/07/18 Data filename: P:\1842xxx\1842064\06Design\09 Energy Code\Energy Compliance-Elec(2015 IECC).cck Page 5 of 6 Northeastern Air Quality, Inc. P.O. Box 3271 Albany, New York 12203 (518) 857-3641 of HVAC SYSTEMS TESTING: Air Balance Report [ Et mum 'a Project: Old Navy Outlets at Lake George Location: Lake George, New York Architect: Sargenti Architects Paramus, New Jersey Engineer: M-Engineering New York, LLC Westerville, nhio Piping: Sheet Metal: Glens Falls Metal Fabricators, Inc. Fort Edward, New York Date: May 7, 2019 Prepared by: R. Kelley RKelley(NortheasternAirQuality.com i 't x~�����U0oC ATx0"N PROJECT old umvy Outlets at Lake George ADDRESS: Lake George, New York THE DATA PRESENTED |N THIS REPORT |SAN EXACT RECORD DFSYSTEM PERFORMANCE AND WAS OBTAINED |N ACCORDANCE WITH NEBBSTANDARD PROCEDURES.ANY VARIANCES FROM DESIGNED QUANTITIES WHICH EXCEEDS NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE |N ACCORDANCE WITH NE8B "PROCEDURAL STANDARDS FOR TESTING AND BALANCING C}F ENVIRONMENTAL SYSTEM"AND THE PROJECT SPECIFICATIONS. TESTING AND BALANCING FIRM- Northeastern Air Quality, Inc. #3159 CERTIFIED BY: Robert V. Kelley DATE: _ 5/7/2018 SIGNATURE: ^ ' Page 2 -^ BBR=VI A T1nNS Northeastern Air Quality,Inc. e i-- " rs v v P.O.Box 3271,Albany.NY 12203-0271 (518)857-3641 PROJECT: Old Navy Outlets at Lake George THE FOLLOWING IS A LIST OF STANDARD ABBREVIATIONS WHICH MAY APPEAR IN THIS REPORT: ABBREVIATION MEANING ABBREVIATION MEANING A AMPS or AMPERAGE NL NOT LISTED ACH AIR CHANGES PER HOUR NOM NOMINAL AD ACCESS DOOR NOM EFFY NOMINAL EFFICIENCY ADJ ADJUSTABLE NR NOT REQUIRED Ak KINETIC(EFFECTIVE FREE)AREA NS NOT SPECIFIED BG BLAST GATE OBD OPPOSED BLADE DAMPER BHP BRAKE HORSEPOWER OED OPEN END DUCT CALC CALCULATED PF POWER FACTOR CALIBR CALIBRATION or CALIBRATED PH PHASE CD CEILING DIFFUSER Ps STATIC PRESSURE CF CUBIC FEET Pt TOTAL PRESSURE CFM CUBIC FEET PER MINUTE Pv VELOCITY PRESSURE cL CENTERLINE RG RETURN GRILLE CLG CEILING RPM REVOLUTIONS PER MINUTE CR CEILING REGISTER RR RETURN REGISTER CS CIRCUIT SETTER SBD SINGLE BLADE DAMPER CSD CEILING SUPPLY DIFFUSER SD SMOKE CONTROL DAMPER DD DIRECT DRIVE SF SERVICE FACTOR DDC DIRECT DIGITAL CONTROL SMC SHEET METAL CONTRACTOR DISC DISCONNECT SWITCH SPS STATIC PRESSURE SENSOR DISCH DISCHARGE SR SUPPLY REGISTER DPR DAMPER TC TEMPERATURE CONTROL AP PRESSURE DIFFERENTIAL TCC TEMPERATURE CONTROL CONTRACTOR EC END CAP TCD TEMPERATURE CONTROL DAMPER ER EXHAUST REGISTER TP THERMALLY PROTECTED FL BHP BRAKE HORSEPOWER @ FULL LOAD AMPS TRAV DUCT TRAVERSE FLA FULL LOAD AMPS V VOLTS or VOLTAGE FIR FINNED TUBE RADIATION VAR VARIABLE GPM GALLONS PER MINUTE VBD V-BELT DRIVE HP HORSEPOWER VD VOLUME DAMPER LD LINEAR DIFFUSER VEL VELOCITY LF LINEAR FEET(NOMINAL) W WATTS or WATTAGE NA NOT ACCESSIBLE WG WALL GRILLE ND NO DAMPER WMS WIRE MESH SCREEN NDRG NON-DUCTED RETURN GRILLE WR WALL REGISTER NG NO GAUGE ZD ZONE DAMPER NI NOT INSTALLED NIC NOT IN CONTRACT I I Page 3 Northeastern Air Quality,Inc. AIR MOVEMENT EQUIPMENT TEST SHEET P.O.Box 3271,Albany,NY 12203-0271 (518)857-3641 PROJECT: Old Navy Outlets at Lake George TESTED BY: N. Mally DATE: 5a/2019 SYSTEM: RTU- LOCATION: Roof SERVICE: Store MANUFACTURER: Trane MODEL: YCD480B4LL1 B3MHAAB00000HHB0000R SERIAL NUMBER: C14G04312 DATE TESTED: 5/7/2019 MANUFACTURER Baldor MOTOR STYLE FRAME - 254T NAME- HP RPM 15 1765 PLATE VOLTS PHASE HERTZ 460 3 60 DATA FL AMPS S.F. 17.7 1.15 P.F. NOM EFFY 86.0% 93.0% CALCULATED(RE.x NOM EFFY)* 0.80 STARTER HEATER ELEMENTS - MOTOR SHEAVE 2B5V50 x B1 5/8" FAN SHEAVE 2B5V136 x B1 11/16 BELTS 2BX97 SHEAVE cL DISTANCE 34 3/4" TEST DATA DESIGN ACTUAL DESIGN ACTUAL FAN RPM - 586 TOTAL CFM-FAN 13,155 12,448 TOTAL CFM-OUTLETS 13,155 12,448 RETURN AIR CFM - 10,069 OUTSIDE AIR CFM - 2,379 EXT. DISCHARGE NL 1.08 STATIC INLET NL -0.01 PRESSURE TOTAL - 1.09 VOLTS T1-T2 460 498 T2-T3(3 Ph only) 492 T1-T3(3 Ph only) 499 AMPS T1 17.7 10.4 T2 (3 Ph only) 11.8 T3(3Phonly) I i1.1 BHP(calc.) F.L.A. ACTUAL 10.22 REMARKS: I 1 *NOTE: If P.F.or NOM EFFY are NL, (P.F.x NOM EFFY)=746Hp/(VAX), where X=1 if 1 Ph,and 1.73 if 3 Ph I I Page 4 Northeastern Air Quality,Inc. FAN TEST REPORT P.O.Box 3271,Albany,NY 1 22 03-02 71 (518)857-3641 PROJECT: Old Navy Outlets at Lake George TESTED BY: N. Mailly DATE: 5/7/19 FAN NUMBER: EF-1 LOCATION: Roof SERVICE: Bathrooms MANUFACTURER: Greenheck MODEL: GB-071-4-X SERIAL NUMBER: 15802746 f DATE TESTED: I 5/7/2019 I I I I MAKE: I Greenheck I I MOTOR STYI E/FRAMF; 48Y I 9 I NAME- HP/RPM: 1/4 1725 I I PLATE VOLTS: 115 DATA PHASE/HERTZ: 1 60 FL AMPS/SF: 4.6 1.35 P.F./NOM EFFY NL NL calc(P.F.x NOM EFFY) * 0.72 MOTOR SHEAVE: - FAN SHEAVE: - BELTS: - 1 SHEAVE cL DISTANCE: I - J TEST DATA DES ACT DES ACT DES ACT DES ACT TOTAL CFM-FAN - - TOTAL CFM-OUTLETS 290 277 FAN RPM - 1,483 EXT. DISCHARGE NL - NL NL I NL STATIC INLET NL - NL NL NL PRESS. TOTAL - VOLTS T1-T2 115 122 T2-T3(3 Ph only) T3-T1 (3 Ph only) AMPS T1 4.6 4.5 T2(3 Ph only) T3(3 Ph only) BHP(calc) F.L./ACTUAL 0.53 1 REMARKS: I I ; i *NOTE: If P.F.or NOM EFFY are NL, (P.F.x NOM EFFY)=746Hp/(VAX), where X=1 if 1 Ph,and 1.73 if 3 Ph p I 1 1 Page 5 Northeastern Air Quality,Inc. AIR TERMINAL BOX CALIBRATION REPORT P.O.Box 3271,Albany,NY 12203-0271 PROJECT: Old Navy Outlets at Lake George (518)857-3641 TESTED BY: N. Mailly Date: 5/7/2019 REMARKS: UNIT UNIT UNIT DESIGN DDC MEAS'D CALIBR FINAL % SYSTEM NUMBER LOCATION TYPE SIZE MAX MIN CFM CFM FACTOR MAX MIN DES MAX DATE REMARKS RTU-1 FPB 2 1 Sales FPB 14 2,405 900 2,366 .2,365 1 2,365 885 98% 5/7/2019 FPB 3 4 2 Sales FPB 14 _ 2,700 900 _ 2,721 2,381 0.88 2,678 893 99% 5/7/2019 FPB 5 3 Stock/Toilet FPB 14 1,850 900 1,389 1,626 1.16 1,626 791 88% 5/7/2019 VAV 6 4 Manager's Office VAV 6 _ 500 106 _ 492 522 1.22 538 114 108% 5/7/2019_ FPB 4 5 Sales FPB 14 2,700 900 2,414 2,781 1.16 2,781 927 103% 5/7/2019 FPB 1 6 _ Front FPB 14 3,000 1,000 _ 2,443 2,462 0.5 2,461 820 82% 5/7/2019 TOTAL 13,155 E 12,448 95% 5/7/2019 Page 6 Northeastern Air Quality,Inc. GRILLE, REGISTER&DIFFUSER REPORT P.O Box 3271,Albany,NY 12203-0271 PROJECT: Old Navy Outlets at Lake George (518)857-3641 TESTED BY: N. Willy DATE: 5/7/2019 REMARKS: FPB and VAV flow sensors were calibrated by measuring CFM by traversing inlet duct. FPB blowers were adjusted to be slightly negative across filter at design CFM. DESIGN INITIAL INTERMEDIATE FINAL % NO. LOCATION SIZE MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS RTU-1 _ FPB-2 1 Sales Area 4"x 16" 0.25 1,231 310 — See Traverse Page _ 2 Sales Area 4"x 16" 0.25 _894 225 _ 3 BOH 8"x 24" 1.02 591 600 4 BOH 8"x 12" 0.47 422 200 _ _ 5 Sales Area 8"x 12" 0.47 654 310 _ _ 6 Sales Area 8"x 12" 0.47 _475 225 _ _ 7 Sales Area 8"x 12" 0.47 475 225 . _ 8 Sales Area 8"x 12" 0.47 _654 310 Y _ Total _ 2,405 2,365 98% 5/7/19_ _ — FPB 3 _ 9 Sales Area 6"x 16" 0.45 993 450 See Traverse Page 10 Sales Area 6"x 16" 0.45 993 450 _ _ 11 Sales Area 8"x 24" 1.02 443 450 _ _ _ _ 12 Sales Area 8"x 24" 1.02 443 450 _ 13 Cash Wrap 8"x 24" 1.02 443 450 _ 14 y Cash Wrap 8"x 24" 1.02 443 450 _ Total 2,700 2,678 99% 5/7/19 FPB 5 _ 16 Women's Toilet 24"x 24" _ 50 Hood 54 _ 108% 5/7/19 __ 17 Toilet Room Corridor 12"x 12" 100 Hood 96 _ 96% 5/7/19 18 Men's Toilet Room 24"x 24" 50 Hood 53 106% 5/7/19 19 Stock Processing Area 4"x 16" 0.25 1,192 300 See Traverse Page _ 20 Stock Processing Area 4"x 16" 0.25 1,192 300 _ 21 Stock Processing Area 8"x 12" 0.47 633 300 22 Fitting Rooms 8"x 14" 0.56 585 330 _ Page 7 Northeastern Air Quality,Inc. GRILLE, REGISTER&DIFFUSER REPORT P.O.Box 3271,Albany,NY 12203-0271 PROJECT: Old Navy Outlets at Lake George (518)857-3641 TESTED BY: N. Madly DATE:— 5/7/2019 _moo. REMARKS: FPB and VAV flow sensors were calibrated by measuring CFM by traversing inlet duct. FPB blowers were adjusted to be slightly negative across filter at design CFM. DESIGN INITIAL INTERMEDIATE FINAL %OF NO. LOCATION SIZE MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS 23 Fitting Rooms 6"x 12" 0.33 640 210 — — 24 Fitting Rooms 6"x 12" 0.33 640 210 — Total 1,850 1,626 88% 5/7/19 VAV-6 25 Manager's Office 24"x 24" 500 Hood 538 Hood 538 108% 5/7/19 FPB 4 26 Sales Area 6"x 16" 0.45 993 450 — See Traverse PaQ 27 Sales Area 6"x 16" 0.45 993 450 _ 28 Sales Area 8"x 24" 1.02 443 450 29 Sales Area 8"x 24" 1.02 443 450 _ 30 Sales Area 8"x 24" 1.02 443 450 31 Sales Area 8"x 24" 1.02 443 450 Total 2,700 2,7'81 103% 5/7/19 FPB-132 Front 8"x 24" 1.02 197 200 See Traverse Page 33 Front 8"x 24" 1.02 197 200 34 Front 8"x 24" 1.02 542 550 35 Front 8"x 24" 1.02 542 550 36 Front 8"x 24" 1.02 542 550 —_ 37 Front 4"x 16" 0.25 2,185 550 _ 38 Front 4"x 16" 0.25 1,589 400 Total 3,000 2,461 82% 517119 Total 13,155 12,448 95% 5/7/19 Page 8 Northeastern Air Quality,Inc. GRILLE, REGISTER&DIFFUSER REPORT P.O Box 3271,Albany,NY 12203-0271 PROJECT: Old Navy Outlets at Lake George (518)857-3641 TESTED BY: N. Mailly DATE: 5/7/2019 REMARKS: FPB and VAV flow sensors were calibrated by measuring CFM by traversing inlet duct. FPB blowers were adjusted to be slightly negative across fillter at design CFM. DESIGN INITIAL INTERMEDIATE FINAL %OF NO. LOCATION SIZE MODEL Ak _VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS Return 39 Cash Wrap 16"x 60" 7.33 679 4,979 713 5,229 713 5,229 105% 5/7/19 39.5 Cash Wrap 16"x 60" 7.33 679 4,979 660 4,840 _ 660 4,840 97% 5/7/19 Total _ 9,958 — 10,069 101% 5/7119 Women's Toilet 40 Women's Toilet 12"x 12" 120 Hood 114 Hood 114 95% 5/7/19 41 Janitor's 12"x 12" 50 Hood 55 Hood 55 110% 5/7/19 42 Men's Toilet 12"x 12" _ 120 Hood 108 Hood 108 90% 5/7/19 Total 290 277 277 96% 5/7/19 Page 9 Northeastern Air Quality,Inc. Duct Traverse Totals P.O. Box 3271, Albany. NY 12203-0271 PROJECT: Old Navy Outlets at Lake George (518) 857-3641 DATE: 5/7/2019 - AMIN .., System Area DESIGN REQUIRMENT INITIAL FINAL %OF NO. Zone or Branch Duct Size Sq. Ft. VEL CFM VEL CFM SP VEL CFM SP DES DATE ...... .... ... s. T-1 FPB 2 14" Rnd '1.07 2,251 2,405 2,213 2,365 0.50 2,213 2,365 0.50 98% 5/7/19 T-2 FPB 3 14" Rnd 1.07 2,527 2,700 2,228 2,381 0.65 2,506 2,678 0.41 99% 5/7/19 T-3 FPB 5 12" Rnd 0.79 2,357 1,850 :2,071 1,626 0.21 2,071 1,626 0.21 88% 5/7/19 T-4 VA V 6 8" Rnd 0.35 1,433 500 1,496 522 0.49 1,543 538 0.58 108% 5/7/19 T-5 FPB 4 14" Rnd 1.07 2,527 2,700 2,603 2,781 0.19 2,603 2,781 0.19 103% 5/7/19 T-6 FPB 1 14" Rnd '1.07 2,808 3,000 911 973 1.02 2,303 2,461 0.23 82% 5/7/19 TOTAL 13,155 10,647 12,448 95% 5/7/19 t s IN-Engineering May 8, 2019 To: Town of Queensbury Department of Buildings 742 Bay Road Queensbury, NY 12809 518-761-8246 From: M-Engineering— Rachael Dorothy RE: Old Navy—Outlets at Lake George 1424 State Route 9 Suite 100 (West Building) Lake George, NY 12845 MEP Certification of Compliance: Please note that as of May 8, 2019 the Old Navy Outlet Store is in compliance with standard building practices and was built in accordance with the plans and specifications provided by our office. Sincerely, � t- t.`.;•='P `z. L 5 1 qy Y �� 4 - i3 7fi� t;�� G� 19. f 4 q7.:;- L.--i_ 7 \-44,,,, ..,, ,,,;,,f.„ ..,,,, -.,-,-,,,,-„,,,„,4,1` -",+.:$7 Mark Huffnagle, PE Uy NY#85671 Structural . Mechanical 9 Electrical 9 Technology 750 Brooksedge Boulevard, Westerville, Ohio 43081 0 614-839-4639 614-839-2222 Fax 0 www.rnengineerino.us.corn -I. ..r SARGENT May 2, 2019 TO: Town of Queensbury Department of Buildings 742 Bay Road Queensbury, NY 12809 518-761-8256 FROM: Sargentii Architects - Kristen Lombardo RE: OLD NAVY-Outlets at Lake George 1424 State Route 9 Suite 100 (West Building) Lake George, NY 12845 Architectural Certification of Compliance: Please note that as of May 2, 2019, the Old Navy Outlet Store is in compliance and was built in accordance with the plans provided by our office. Sincerely, ,,rr? f �, , SARG, Robert Sargentr;' ,-� N,r '% �'� Principal 'J. .Cr r _,... ' y . „ _ * / 1✓f �i �'`?q �26235 �� � W p'N! .,` Page 1 of 1 T.973.253.9393 461 From Road,Second Floor,Paramus,NJ 07652 www.sargarch.com P.007 RX DatelTime 05109/2019 12:1315182731202 No. 8553 P. 7/7 �, Cry�{j�c%.v:���.'•i'•�*•r i� ^May, 9. 2 019 11 :53 'M ��.:,��..'_-`=�, ��:..��,zr4 v%�,�.�. 0*Wf.,t g;�w,:,--;w':.•-,,:ist e;,.,.,,-., �`� MIDDLE DEPARTMENT INSPECTION AGENCY, INC. s � � that the electrical wiring to the electrical equipment listed below has been examined and is approved as 5:5 i< being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date ; '1(41 noted below and is issued subject to the following conditions. Chi Owner: S%:4 Old Navy „y Date: 05/02/2019 $;)i �� Occupant: Comm. Locatio << l �i415 Route 9 • Occupancy- Queensbury, Co. NY C�� F'0) Non-Residential ry' rft �j Applicant: C� ,A Burbank Elec. Contr,Inc. j 3 Van Buren Rd- C Glenville NY 12302 • 1,1 O I4, r� Joseph A.Holmes. .. C��� g No. . 140377109389EL.. • ��� Equipment: CGS -Z • 0 1 -225 Amp Panel; 1 -125 Amp Panel;-1 -75 KVA Transformer, 1 -60 Amp MOP: 1--Hand Dryer; 2 -40 Amp HVAC S Units; 3-25 Amp FPBs; 1 -30 Amp F.P.B; 1 -25 Amp HVAC Unit; 600-Amp. Service Equipment; 2-500 MCM• S� Service Conductors; 8 -Switches; 62-Receptacles; 242- Fixtures; 11 - Exit Lights "� • • " . • • . .. ._.: . • ... -.1 ' DIE C E 0 V E 0 l k TOWN OF OUEENSPURY (=S BUILDING&CODES rc �e�j (0 �� This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy antl0(( �(:,•) above and the installation inspected as of the above noted date based on a visual ownership as indicates herein. Upon a change in the use.occupancy or ownership ifA) inspection. No warranty is expressed or implied as to the mechanical safety,effl- of the property indicated above,this Certificate shall be immediately null and void. f(�� era ciency or fitness of me equipment for any particular purpose. This certificate shall In the event that this certificate becomes Invalid based Upon the above conditions. << be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department S>`. l7t) system to which this certificate applies be altered in any way.including but not limit. Inspection Agency,Inc. An application for Inspection must be submitted to Middle ed to.the introduction of additional electrical equipment and/or the replacement of Department inspection Agency, Inc. tp initiate the Inspection and revalidation r any of the components installed as of the above noted date,this certificate shall be process. A fee will be charged for this service. 'VI Cr.Y:�r'. c*'r�9%ri.• i` i rn Y�i`.�r; %i.;% t rJ 1•r�y �i 1��:�r ; :4r ��y 'Yr;;:r.,rI' ti ;c;>:.y .;i�� >.�,.c r �N•.r C C> ,.ijf' >r ifi�f r v •rS�>e ; {l46 i�. i 1ZIR r } S,�.rxv:r 1.i:.}t ...\-.u, r. l.;`'_%,r �lr'?4,, L+.`'�� :� ti.�=��:�G J i ,.�lG'J y S•�•i.,� =ti�:�✓. <� •.�•..t ti.v•�•.��<v' �;�-%�✓ *✓,.3.ti .�•.�� Gti 3 L v%V' t � 14 0 r M-Engineering _ . _m__a_-_.__._-_ _ _ ____ May 9, 2019 ECEEOWEE [rill To: Town of Queensbury MAY 202019 Department of Buildings 742 Bay Road TOWN OF QUEENSBURY Queensbury, NY 12809 L. BUILDING& CODES 518-761-8246 QC,''01'1,0 5 - 1A1 From: M-Engineering— Rachael Dorothy RE: Old Navy—Outlets at Lake George 1424 State Route 9 Suite 100 (West Building) Lake George, NY 12845 MEP Certification of Compliance: Please note that as of May 9, 2019 the project, Old Navy Outlet, has been completed in accordance with the approved plans and the COMcheck for Electrical and Mechanical based on the 2015 IECC, Sincerely, `o ,' ‘" --9„.4-91 444* i' � i l ,�1 ,' i V Y h °A;' -85 6 ji\ 4: Mark Huffnagle, PE .-ESSIO NY#85671 Structural • Mechanical • Electrical • Technology 750 Brooksedge Boulevard, Westerville, Ohio 43081 • 614-839-4639 614-839-2222 Fax • www.mengineering.us.com INSPECTION WORKSHEET (BINS-002507-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0768-2018 Case Module:Permit Inspection Date:Thu May 9, 2019 Inspection Status:Passed Inspector:John O'Brien Inspection Type:Commercial Final Inspection Job Address:Parcel Number:1415 State Rte 9 Lake George, NY 12845 288.-1-53 Contact Type Company Name Name Architect Sargenti Architects Contractor Desco Professional Builders Inc Primary Owner Gap Inc Granted Permission Desco Professional Builders Inc Applicant Expedite Permit Property Owner Northway Outlets, LLC Checklist Item Passed Comments Firewalls, 2 Hr, 3 Hr / Fire Dampers / Fire Doors YES - Complete sealing vacant space side of fire rated tenant separation wall. Universal Symbol of Access displayed - on all H/C signs YES - Install handicapped signage for restroom and fitting room. Final Electrical / Flex Gas Piping Bonded YES - Obtain Final Electrical Inspection Bldg Num or Tenant Address on Bld or Drive YES - Install Suite Number at main entrance door. Minimum 4" high numbers or letters. May 09, 2019 Page (1) INSPECTION WORKSHEET (BINS-002507-2019) Checklist Item Passed Comments Engineer or Architect Approval YES - Provide the final approval letter from the Architect/Engineer stating that the project has been completed in accordance with the approved plans and the COMcheck for Electrical & Mechanical based on the 2015 IECC. Special Inspections YES - Provide HVAC Balancing Report OK to Issue C/O YES 5/2/19 Final Inspection Not Approved Remaining Items: - Complete sealing vacant space side of fire rated tenant separation wall. - Install handicapped signage for restroom and fitting room. - Obtain Final Electrical Inspection - Install Suite Number at main entrance door. Minimum 4" high numbers or letters. - Provide the final approval letter from the Architect/Engineer stating that the project has been completed in accordance with the approved plans and the COMcheck for Electrical & Mechanical based on the 2015 IECC. - Provide HVAC Balancing Report - Complete Fire Marshal's Items 5/9/19 Final Inspection Approved - Ok to Issue CO! May 09, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (BINS-002385-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0768-2018 Case Module:Permit Inspection Date:Thu May 2, 2019 Inspection Status:Failed Inspector:John O'Brien Inspection Type:Commercial Final Inspection Job Address:Parcel Number:1415 State Rte 9 Lake George, NY 12845 288.-1-53 Contact Type Company Name Name Granted Permission Desco Professional Builders Inc Architect Sargenti Architects Primary Owner Gap Inc Contractor Desco Professional Builders Inc Property Owner Northway Outlets, LLC Applicant Expedite Permit Checklist Item Passed Comments Firewalls, 2 Hr, 3 Hr / Fire Dampers / Fire Doors NO - Complete sealing vacant space side of fire rated tenant separation wall. Handicapped Bath/Parking Lot Signage NO Universal Symbol of Access displayed - on all H/C signs NO - Install handicapped signage for restroom and fitting room. Final Electrical / Flex Gas Piping Bonded NO - Obtain Final Electrical Inspection Public Sewer Sign-Off NO May 02, 2019 Page (1) INSPECTION WORKSHEET (BINS-002385-2019) Checklist Item Passed Comments Bldg Num or Tenant Address on Bld or Drive NO - Install Suite Number at main entrance door. Minimum 4" high numbers or letters. Engineer or Architect Approval NO - Provide the final approval letter from the Architect/Engineer stating that the project has been completed in accordance with the approved plans and the COMcheck for Electrical & Mechanical based on the 2015 IECC. Special Inspections NO - Provide HVAC Balancing Report OK to Issue Temporary C/O NO OK to Issue C/O NO 5/2/19 Final Inspection Not Approved Remaining Items: - Complete sealing vacant space side of fire rated tenant separation wall. - Install handicapped signage for restroom and fitting room. - Obtain Final Electrical Inspection - Install Suite Number at main entrance door. Minimum 4" high numbers or letters. - Provide the final approval letter from the Architect/Engineer stating that the project has been completed in accordance with the approved plans and the COMcheck for Electrical & Mechanical based on the 2015 IECC. - Provide HVAC Balancing Report - Complete Fire Marshal's Items May 02, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (FIST-002160-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0768-2018 Case Module:Permit Inspection Date:Wed Apr 24, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Firestopping Job Address:Parcel Number:1415 State Rte 9 Lake George, NY 12845 288.-1-53 Contact Type Company Name Name Contractor Desco Professional Builders Inc Property Owner Northway Outlets, LLC Applicant Expedite Permit Granted Permission Desco Professional Builders Inc Architect Sargenti Architects Primary Owner Gap Inc Checklist Item Passed Comments Building Inspector Notes NO 3/18/19 Fire Separation Partial Approval - Tenant Fire Separation Wall - Area of fire separation wall behind soffit in northwest corner of Old Navy space. 4/4/19 Fire Separation Not Approved - Old Navy side still lacking fire caulk at penetrations and at top of wall. Will recheck at inspection of opposite side of fire separation wall. 4/24/19 Fire Separation Partial Approval - Old Navy side of tenant separation wall ok to paint. Remaining Item: - Vacant space side of tenant separation wall needs penetrations sealed with fire caulk. Apr 24, 2019 Page (1) INSPECTION WORKSHEET (FIST-002160-2019) Checklist Item Passed Comments Fire separation 1, 2, 3 hour NO 3/18/19 Fire Separation Partial Approval - Tenant Fire Separation Wall - Area of fire separation wall behind soffit in northwest corner of Old Navy space. 4/4/19 Fire Separation Not Approved - Old Navy side still lacking fire caulk at penetrations and at top of wall. Will recheck at inspection of opposite side of fire separation wall. 4/24/19 Fire Separation Partial Approval - Old Navy side of tenant separation wall ok to paint. Remaining Item: - Vacant space side of tenant separation wall needs penetrations sealed with fire caulk. Penetration sealed NO 4/24/19 Fire Separation Partial Approval - Old Navy side of tenant separation wall ok to paint. Remaining Item: - Vacant space side of tenant separation wall needs penetrations sealed with fire caulk. Apr 24, 2019 Page (2) O'Brien, John (Inspector)