asbestos report
(,) JAN 2 2 2019 I FILE COPY Nix) TOWN OF QUEENSBURY ENVIRONMENTAL SERVICES BUILDING&CODES REPORT OF ASBESTOS INSPECTION (Revised 10/18/2018) Location of Inspection: 26 South Western Avenue Queensbury, New York 12804 Client: Hudson Headwaters Health Network 9 Carey Road Queensbury, New York 12804 Building Owner: Keith and Kathleen Sweet 39 Mallory Avenue Queensbury, New York 12804 Alpine Project#: 18-23084-A TOWN OF QUEENSBURY BUILDING DEPARTMENT Material or Area Inspected: Entire Building Based on our limited examination,compliance with our comments shall not be construed as Asbestos Material Tested or Assumed: indicating the plans and specifications are in roll roofing, flashing tar/cement,.full compliance with the Building Codes of New York State. Non-Asbestos Containing Materials Tested: drywall, joint compound, textured ceiling treatment, block mortar, chimney block mortar, fiberboard, 12" self stick floor tile, linoleum and mastic, mastic on concrete floor, asphalt siding and vapor barrier, window glazing compounds, roof shingle and vapor barrier, vapor barrier under metal roofing, vapor barrier under roll roofing, and flashing caulk, tub surround adhesive, ceramic tile/ grout/mortar. Dates of Inspection: August 22, and October 12, 2018 Date of Report: August 30, 2018 Date of Report Revision: October 18, 2018 TOWN OF QUEENSBURY 309.7-1-54 DEMO-0029-2019 BUILDING & CO T. HHHN Reviewe By: 26 Western Ave S Date: l Demolition of SFD August 22,2018 26 South Western Avenue Queensbury, New York Inspection Performed By: Alpine Environmental Services, Inc. 438 New Karner Road Albany, New York 12205 Phone (518) 250-4047 Inspector(s): Brian Gould AH 95-02582 Michael Balzano NYS Department of Labor Certified Asbestos Inspector(s) 1.0 Asbestos Inspection: 1.1 Scope and Purpose This report is intended to document the pre-demolition asbestos inspection of the residential building located at 26 South Western Avenue in Queensbury, New York. "Asbestos containing materials", as defined by the United States Environmental Protection Agency (EPA), is any material containing more than 1% asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, Polarized Light Microscopy. Bulk samples were collected in accordance with USEPA ASHARA protocols for number and types of samples. Materials easily crushed or pulverized by hand pressure are considered friable. Materials with a bituminous or resinous binder that are not easily crushed or pulverized by hand pressure are considered Non-friable Organically Bound (NOB). Friable and non-friable materials, excluding organically bound materials were analyzed using Polarized Light Microscopy (PLM). Non-Friable Organically Bound samples were analyzed using Transmission Electron Microscopy (TEM). All samples were analyzed by EMSL Analytical (ELAP 11506: Manhattan Lab). 1.2 Description The building inspected for the survey is a single story residential structure of wood frame construction with a partial basement. This building was built in or about 1950. Flooring materials observed include; concrete, carpet, 12" self stick floor tile, and linoleum. Wall materials include drywall with joint compound. Ceiling materials include; drywall, with textured treatment in living room, kitchen, and bedroom. 1.3 Limitation This inspection addresses accessible areas of the above mentioned building. Quantities of asbestos containing materials were estimated and the user must field verify all quantities. Penetrations were made in existing walls to confirm the absence of asbestos containing materials within wall chases. There were penetrations made in the basement block walls to determine whether loose fill vermiculite was present in the voids of the cement blocks. There was no vermiculite observed within the basement block walls. Materials inside the furnace were not inspected. Suspect materials inside the furnace must be assumed to be asbestos containing and treated accordingly. The electrical system within the building was energized at the time of Alpine Environmental Services' site visits. Alpine observed only the newer non-suspect vinyl clad wire insulation in the building. Page 2 438 New Karner Road Albany, New York 12205 Phone: (518)250-4047 August 22,2018 26 South Western Avenue Queensbury,New York Any suspect materials found during demolition/renovation activities that are not listed in this report should be considered asbestos containing materials until tested and determined otherwise. 1.4 Results of Inspection Bulk samples were collected throughout the interior and exterior of the building. Samples were collected as prescribed by US EPA ASHARA protocols for the numbers and types of samples. See the sample results section for all samples collected and the results of analysis. 1.5 Conclusion and Recommendations The following asbestos containing materials were found at the residential building located at 26 South Western Avenue in Queensbury, New York: Table 1: Asbestos Containing Materials Tested or Assumed Homogeneous Location Substrate& Approx. Friability Condition Material Accessibility Quantity Roll Roofing Interior of South Wood Roof 70 sf Non-Friable Damaged (12-01, 12-02) Attic, on Old Roof Deck Flashing Roof at Masonry Masonry, Tar/Cement Chimney, and Roof Asphalt, 2 sf Non-Friable Damaged (13-01, 13-02) Overhang at Door Wood, Metal Please note these quantities are only estimates and the user should field verify all quantities. The following materials were sampled by Alpine Environmental Services and determined not to contain asbestos: Table 2: Non-Asbestos Containing Materials Tested Non-Asbestos Locations Sample#'s Material Drywall and Joint Stair to Basement, Bathroom, 1-01, 1-02, 1A-01, 1A-02 Compound West Room at Stair to Basement Textured Ceiling Kitchen 2-01, 2-02, 2-03 Treatment Block Mortar Garage, at House 3-01, 3-02 Exterior: East Side at Living Room Chimney Block Mortar Roof: Masonry Chimney 3A-01, 3A-02 Fiberboard Garage; East Wall 4-01, 4-02 12" Self Stick Kitchen 5-01, 5-02 Floor Tile Linoleum and Mastic Bathroom 6-01, 6-02, 6M-01, 6M-02 Mastic West Room on Concrete Floor 7-01, 7-02 Asphalt Siding and Garage 8-01, 8-02, 8A-01, 8A-02 Vapor Barrier Window Glazing Basement Window: East Side Compounds East Side at Living Room 9-01, 9-02, 9A-01, 9A-02 South Side at Attic Roof Shingle and Main Roof adj Masonry Chimney 10-01, 10-02, Vapor Barrier 10A-01, 10A-02 Vapor Barrier Under West Roof 11-01, 11-02 Metal Roofing Page 3 438 New Karner Road Albany, New York 12205 Phone: (518)250-4047 August 22,2018 26 South Western Avenue Queensbury,New York Table 2 continued: Non-Asbestos Containing Materials Tested Non-Asbestos Locations Sample Ws Material Roll Roofing Vapor South Attic at Original Roof 12A-01, 12A-02 Barrier Flashing Caulk West Roof:At Metal Chimney 14-01, 14-02 Tub Surround Bathroom 04-01, 04-02 (10/12/2018) Adhesive Ceramic Tile, Grout, Side Room (West) 01-01, 01-02, 02-01, 02-02, and Mortar 03-01, 03-02 (10/12/2018) Any materials not sampled during this inspection should be considered suspect unless sampled and determined to be non-asbestos. All asbestos containing materials must be abated prior to the demolition/renovation of any part of the structure unless performed under a variance issued by the NYS Department of Labor. Disturbance/Abatement of any asbestos containing materials, as well as necessary air monitoring, must be performed by a NYS DOL licensed contractor, in accordance with state and federal regulations (NYS DOL ICR 56 and US EPA 40 CFR). If Alpine Environmental Services can be of further assistance on this matter, please contact Craig Petreikis at either 518) 250-4047 ext. 313 or craiqp(@,alpineenv.com. Sincerely, Alpine Environmental Services, Inc. 7 Brian Gould NYS Dept. of Labor Asbestos Inspector Enclosures: Results, NYSDOL Handling License(s), NYSDOL Handling Certificate(s), NYSDOH ELAP License(s), drawings Page 4 438 New Karner Road Albany, New York 12205 Phone: (518) 250-4047 First Floor 26 South Western Avenue Queensbury, New York 12804 Garage Bath Bed Room Room West Room Kitchen Living Room Asbestos Containing Materials Location Diagram Attic and Roof 26 South Western Avenue Queensbury, New York 12804 OI ASBESTOS CONTAINING MATERIALS: Access to Attic Through Window Asbestos Containing Flashing Tar/Cement. This Location. Asbestos Containing Roll Roofing in Attic. EMSL Analytical, Inc. EMSL Order: 031823166 EMSL 307 West 38th Street New York,NY 10018 Customer ID: ALPI50 Tel/Fax:(212)290-0051/(212)290-0058 Customer PO: http://www.EMSL.com/manhattanlab@emsl.com Project ID: Attention: Alpine Environmental Services Phone: (518)250-4047 438 New Karner Road Fax: Albany, NY 12205 Received Date: 08/23/2018 9:31 AM Analysis Date: 08/25/2018-08/26/2018 Collected Date: 08/22/2018 Project: 18-23084-A/26 SOUTH WESTERN AVE/GLENS FALLS , NY Test Report:Asbestos Analysis of Bulk Material Analyzed Non-Asbestos Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 1-01 Description STAIR TO BSMT-DRYWALL 031823166-0001 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 Brown/White 16.00%Cellulose 55.00% Gypsum None Detected 29.00% Non-fibrous(other) PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 1-02 Description STAIR TO BSMT-DRYWALL 031823166-0002 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 Brown/Gray 10.00%Cellulose 60.00% Gypsum None Detected 30.00% Non-fibrous(other) PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 1A-01 Description BATHROOM-JOINT COMPOUND 031823166-0003 Homogeneity Heterogeneous PLM NYS 198.1 Friable 08/25/2018 White 55.00% Ca Carbonate None Detected 4.00% Mica 41.00% Non-fibrous(other) Inseparable paint/coating layer included in analysis PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 1A-02 Description WEST ROOM AT STAIRS TO BSMT-JOINT COMPOUND 031823166-0004 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 White 60.00% Ca Carbonate None Detected 2.00% Mica 38.00% Non-fibrous(other) PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed ` Initial report from:08/26/2018 04:28:56 J 0009 000r Printed 8/26/2018 9:31:00AM Page 1 of 9 EMSL Analytical, Inc. EMSL Order: 031823166 EMSL 307 West 38th Street New York,NY 10018 Customer ID: ALPI50 Tel/Fax:(212)290-0051/(212)290-0058 Customer PO: http.//www.EMSL.corn/manhattanlab@emsl.com Project ID: Test Report:Asbestos Analysis of Bulk Material Non-Asbestos Analyzed Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 2-01 Description KITCHEN CEILING-TEXTURED CEILING TREATMENT 031823166-0005 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 White 51.00%Ca Carbonate None Detected 8.00% Mica 41.00% Non-fibrous(other) PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 2-02 Description KITCHEN CEILING-TEXTURED CEILING TREATMENT 031823166-0006 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 Tan/White 50.00%Ca Carbonate None Detected 12.00% Mica 38.00% Non-fibrous(other) PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 2-03 Description KITCHEN CEILING-TEXTURED CEILING TREATMENT 031823166-0007 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 White 50.00% Ca Carbonate None Detected 8.00% Mica 42.00% Non-fibrous(other) PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 3-01 Description GARAGE INTERIOR SOUTH SIDE AT HOUSE-BLOCK MORTAR 031823166-0008 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 Gray 2.00%Cellulose 20.00% Ca Carbonate None Detected 48.00% Non-fibrous(other) 30.00% Quartz PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 3-02 Description EXTERIOR EAST SIDE AT LIVINGROOM-BLOCK MORTAR 031823166-0009 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 Gray 4.00%Cellulose 25.00% Ca Carbonate None Detected 41.00% Non-fibrous(other) 30.00% Quartz PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed ' Initial report from:08/26/2018 04:28:56 G5);_7s3x_oG s tx Printed 8/26/2018 9:31:00AM Page 2 of 9 EMSL Analytical, Inc. EMSL Order: 031823166 EMSL 307 West 38th Street New York,NY 10018 Customer ID: ALP150 Tel/Fax:(212)290-0051/(212)290-0058 Customer PO: http.//www.EMSL.com/manhattanlab@emsi.com Project ID: Test Report:Asbestos Analysis of Bulk Material Non-Asbestos Analyzed Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 3A-01 Description ROOF MASONRY CHIMNEY-CHIMNEY BLOCK MOTAR 031823166-0010 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 Gray 20.00% Ca Carbonate None Detected 58.00% Non-fibrous(other) 22.00% Quartz PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 3A-02 Description ROOF MASONRY CHIMNEY-CHIMNEY BLOCK MOTAR 031823166-0011 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 Gray 20.00%Ca Carbonate None Detected 20.00%Gypsum 5.00% Mica 25.00% Non-fibrous(other) 30.00%Quartz PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 4-01 Description GARAGE INTERIOR EAST WALL-FIBERBOARD 031823166-0012 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 Brown 94.00%Cellulose 6.00% Non-fibrous(other) None Detected PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 4-02 Description GARAGE INTERIOR EAST WALL-FIBERBOARD 031823166-0013 Homogeneity Homogeneous PLM NYS 198.1 Friable 08/25/2018 Brown 90.00%Cellulose 10.00% Non-fibrous(other) None Detected PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 5-01 Description KITCHEN-12"SELF STICK FLOOR TILE 031823166-0014 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Black 100.00% Other None Detected Sample ID 5-02 Description KITCHEN-12"SELF STICK FLOOR TILE 031823166-0015 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Black 100.00% Other None Detected ( Initial report from:08/26/2018 04:28:56 ) ASB_198x 0009_00f' Printed 8/26/2018 9:31:00AM Page 3 of 9 EMSL Analytical, Inc. EMSL Order: 031823166 307 West 38th Street New York.NY 10018 Customer ID: ALPI50 Tel/Fax:(212)290-0051/(212)290-0058 Customer PO: http://www.EMSL.com/manhattanlab@emsl.com Project ID: Test Report:Asbestos Analysis of Bulk Material Non-Asbestos Analyzed Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 6M-01 Description BATHROOM-LINOLEUM MATIC 031823166-0016 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Yellow 100.00%Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Yellow 100.00% Other None Detected Sample ID 6M-02 Description BATHROOM-LINOLEUM MATIC 031823166-0017 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Yellow 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Yellow 100.00% Other None Detected Sample ID 6-01 Description BATHROOM-LINOLEUM 031823166-0018 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Beige 100.00% Other Inconclusive:None Detected Final Residue<1%of original subsample TEM NYS 198.4 NOB 08/26/2018 Beige 100.00% Other None Detected Sample ID 6-02 Description BATHROOM-LINOLEUM 031823166-0019 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Beige 100.00% Other Inconclusive:None Detected Final Residue<1%of original subsample TEM NYS 198.4 NOB 08/26/2018 Beige 100.00% Other None Detected Sample ID 7-01 Description WEST ROOM ON CONCRETE FLOOR-MASTIC 031823166-0020 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Yellow 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Yellow 100.00% Other None Detected Sample ID 7-02 Description WEST ROOM ON CONCRETE FLOOR-MASTIC 031823166-0021 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Yellow 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Yellow 100.00% Other None Detected `( Initial report from:08/26/2018 04:28:56 i 98x 0009 000; Printed 8/26/2018 9:31:00AM Page 4 of 9 EMSL Analytical, Inc. EMSL Order: 031823166 Customer ID: ALPI50 ... 307 West 38th Street New York,NY 10018 Customer PO: Tel/Fax:(212)290-0051/(212)290-0058 http.//www.EMSL.com/manhattanlab@emsl.com Project ID: Test Report:Asbestos Analysis of Bulk Material Non-Asbestos Analyzed Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 8-01 Description GARAGE INTERIOR SOUTH WALL-APSHALT SIDING 031823166-0022 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black 1.10%Glass 98.90% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Black 100.00% Other None Detected Sample ID 8-02 Description GARAGE INTERIOR SOUTH WALL-APSHALT SIDING 031823166-0023 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black <1.00%Glass 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Black 100.00%Other None Detected Sample ID 8A-01 Description GARAGE INTERIOR SOUTH WALL-APSHALT SIDING VAPOR BARRIER 031823166-0024 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Brown <1.00%Glass 100,00%Other Inconclusive:None Detected <1.00%Min.Wool TEM NYS 198.4 NOB 08/26/2018 Brown 100.00% Other None Detected Sample ID 8A-02 Description GARAGE INTERIOR SOUTH WALL-APSHALT SIDING VAPOR BARRIER 031823166-0025 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Brown <1,00%Glass 100,00% Other Inconclusive:None Detected <1.00%Min.Wool TEM NYS 198.4 NOB 08/26/2018 Brown 100.00% Other None Detected Sample ID 9-01 Description BSMT-WINDOW GLAZING COMPOUND 031823166-0026 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Gray 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Gray 100.00%Other None Detected Sample ID 9-02 Description BSMT-WINDOW GLAZING COMPOUND 031823166-0027 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Gray 100.00%Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Gray 100.00°A Other None Detected Initial report from:08/26/2018 04:28:56 ASB_198x_0009_000 i Printed 8/26/2018 9:31:00AM Page 5 of 9 EMSL Analytical, Inc. EMSL Order: 031823166 Customer ID: ALPI50 EMSL 307 West 38th Street New York,NY 10018 Tel/Fax:(212)290-0051/(212)290-0058 Customer PO: ... http.i/www.EMSL.com/manhattanlab@emsl.com Project ID: Test Report:Asbestos Analysis of Bulk Material Non-Asbestos Analyzed Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 9A-01 Description EXTERIOR EAST SIDE AT LIVINGROOM-WINDOW GLAZING COMPOUND 031823166-0028 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 White 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 White 100.00% Other None Detected Sample ID 9A-02 Description EXTERIOR EAST SOUTH AT ATTIC-WINDOW GLAZING COMPOUND 031823166-0029 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 White 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 White 100.00% Other None Detected Sample ID 10-01 Description MAIN ROOF-ROOF SHINGLE 031823166-0030 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black 5.50%Glass 94.50% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Black 100.00% Other None Detected Sample ID 10-02 Description MAIN ROOF-ROOF SHINGLE 031823166-0031 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black 4.50%Glass 95.50% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Black 100.00% Other None Detected Sample ID 10A-01 Description MAIN ROOF-ROOF SHINGLE VAPOR BARRIER 031823166-0032 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black None 100.00% Other Inconclusive:<1.00% Chrysotile TEM NYS 198.4 NOB 08/26/2018 Black None 100.00% Other <1.00% Chrysotile Sample ID 10A-02 Description MAIN ROOF-ROOF SHINGLE VAPOR BARRIER 031823166-0033 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Black 100.00% Other None Detected Initial report from:08/26/2018 04:28:56 A b_ibnx_vvCs_Cx Printed 8/26/2018 9:31:00AM Page 6 of 9 EMSL Analytical, Inc. EMSL Order: 031823166 307 West 38th Street New York,NY 10018 Customer ID: ALPI50 Tel/Fax:(212)290-0051/(212)290-0058 Customer PO: http./iwww.EMSL.com/manhattanlab@emsl.com Project ID: Test Report:Asbestos Analysis of Bulk Material Non-Asbestos Analyzed Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 11-01 Description WEST ROOF UNDER METAL-VAPOR BARRIER 031823166-0034 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Black 100.00% Other None Detected Sample ID 11-02 Description WEST ROOF UNDER METAL-VAPOR BARRIER 031823166-0035 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 Black 100.00% Other None Detected Sample ID 12-01 Description SOUTH ATTIC ON ORIGINAL ROOF-ROLL ROOFING 031823166-0036 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black None 96.80% Other 3.20% Chrysotile TEM NYS 198.4 NOB 08/25/2018 Positive Stop(Not Analyzed) Sample ID 12-02 Description SOUTH ATTIC ON ORIGINAL ROOF-ROLL ROOFING VAPOR BARRIER 031823166-0037 Homogeneity PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Positive Stop(Not Analyzed) TEM NYS 198.4 NOB 08/25/2018 Positive Stop(Not Analyzed) Sample ID 12A-01 Description SOUTH ATTIC ON ORIGINAL ROOF-ROLL ROOFING VAPOR BARRIER 031823166-0038 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Brown <1.00%Glass 100.00% Other Inconclusive:<1.00% Chrysotile <1.00%Min.Wool Gravimetric data for the reprep sample not the original sample. TEM NYS 198.4 NOB 08/26/2018 Brown 100.00% Other None Detected Sample ID 12-02 Description SOUTH ATTIC ON ORIGINAL ROOF-ROLL ROOFING VAPOR BARRIER 031823166-0039 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Brown <1.00%Glass 100.00% Other Inconclusive:None Detected <1.00%Min.Wool Final Residue<1%of original subsample TEM NYS 198.4 NOB 08/26/2018 Brown 100.00% Other None Detected N Initial report from:08/26/2018 04:28:56 Printed 8/26/2018 9:31:00AM Page 7 of 9 . EMSL Analytical, Inc. EMSL Order: 031823166 .. 307 West 38th Street New York,NY 10018 Customer ID: ALPI50 Tel/Fax'(212)290-0051/(212)290-0058 Customer PO: ottp.,/www.EMSLcorn%manhattanlab(memsl.com Project ID: Test Report:Asbestos Analysis of Bulk Material Non-Asbestos Analyzed Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 13-01 Description MAIN ROOF AT BLOCK CHIMNEY-FLASHING TAR/CEMENT 031823166-0040 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Black None 98.00% Other 2.00% Chrysotile TEM NYS 198.4 NOB 08/25/2018 Positive Stop(Not Analyzed) Sample ID 13-02 Description SOUTH ROOF OVERHANG AT GABLE WALL-FLASHING TAR/CEMENT 031823166-0041 Homogeneity PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 Positive Stop(Not Analyzed) TEM NYS 198.4 NOB 08/25/2018 Positive Stop(Not Analyzed) Sample ID 14-01 Description WEST ROOF AT METAL CHIMNEY-FLASHING CAULK 031823166-0042 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 White 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 White 100.00% Other None Detected Sample ID 14-02 Description WEST ROOF AT METAL CHIMNEY-FLASHING CAULK 031823166-0043 Homogeneity Homogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 08/25/2018 White 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 08/26/2018 White 100.00% Other None Detected i Initial report from:08/26/2018 04:28:56 • i A54-, a fl=. n''^^ Printed 8/26/2018 9:31:00AM Page 8 of 9 EMSL Analytical, Inc. EMSL Order: 031823166 Customer ID: ALPI50 EMSL 307 West 38th Street New York,NY 10018 Tel/Fax:(212)290-0051/(212)290-0058 Customer PO: http:Nwww.EMSL.com i manhattanlabgemsl.com Project ID: Test Report:Asbestos Analysis of Bulk Material The samples in this report were submitted to EMSL for analysis by Asbestos Analysis of Bulk Materials via NYS ELAP Approved Methods.The reference number for these samples is the EMSL Order ID above. Please use this reference number when calling about these samples. Report Comments: Sample Receipt Date: 8/23/2018 Sample Receipt Time: 9:31 AM Analysis Completed Date: 8/25/2018 Analysis Completed Time: 3:43 PM Analyst(s): fL l vvro ✓1 Jon Williams PLM NYS 198.1 Friable(8) Tiquasha Thompson PLM NYS 198.1 Friable(5) Angelica Aquino PLM NYS 198.6 NOB(28) Miguel Savinon TEM NYS 198.4 NOB(26) Samples reviewed and approved by: ) James Hall,Laboratory Manager or Other Approved Signatory NOB=Non Friable Organically Bound N/A=Not Applicable VCM=Vermiculite Containing Material -In New York State,TEM is currently the only method that can be used to determine if NOB materials can be considered or treated as non-asbestos containing. All samples examined for the presence of vermiculite when analyzed via NYS 198.1. -NYS Guidelines for Vermiculite containing samples are available at http://www.wadsworth.org/labcert/elapcert/forms/VermiculitelnterimGuidance_Rev070913.pdf EMSL maintains liability limited to cost of analysis.This report relates only to the samples reported above and may not be reproduced,except in full,without written approval by EMSL.EMSL bears no responsibility for sample collection activities or analytical method limitations.Interpretation and use of test results are the responsibility of the client. Samples were received in good condition unless otherwise noted. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST,or any agency of the federal government.This report may contain data that is not covered by the NVLAP accreditation. Samples analyzed by EMSL Analytical,Inc.New York,NY NYS ELAP 11506 Initial report from:08/26/2018 04:28:56 Printed 8/26/2018 9:31:00AM Page 9 of 9 8 OrderlD: 031823166 Page 1 Of flipire 09)11 (4,...: ENVIRONMENTAL SERVICES CHAIN OF CUSTODY 31 Client: Alpine Environmental Services,Inc. Project: 26 South Western Avenue 438 New Karncr Road Glens Falls„Nevi, York Albanv.NY 12205 Proixt Number: 18-23084-A Contact Brian Gould Sampled By: Brian Gould E-Mail: BrianG(ii:AlpineEnv.com Late ' Time Collected: 8-22-2018/7:30-9:30 Turnaround Time: 72 hour, Shipper Tracking Number: 7955 4825 8844 (fedex) Ti; Log No. ' sample Sample location Sample Material 1 Analysis Results No. Performed 1-01 Stairs to Basement r Drywall NYS ELAP Protocols 1-02 Stairs to Basement Drywall NYS ELAP/ Protocols t1•/ 1 A-01 Bathroom Joint Compound NYS ELAP Protocols IA-02 West Room Joint Compound NYS El_AP At Stairs to Basement Protocols 2-01 Kitchen-Ceiling Iextared Ceiling NYS i?l AP Stop at Treatment Protocols First Positive • 2-02 Kitchen: Ceiling Textured Ceiling NYS FLAP Treatment Protocols ' 2-03 Kitchen: Ceiling Textured Ceiling NYS ELAP I reatment Protocols i 3-01 Garage Interior: Block Mona' NYS ELAP Stop at South Side at I louse Protocols First Positive 3-02 Exterior: Block Mortar NYS ELAP Last Side at Living Room Protocols A-01 Roof: Masonry Chimney 1 Chimney Block NYS ELAP Stop at I Mortar Protocols First Positive 1A-02 Roof: Mason() Chimney Chinmeti Block NYS ELM' Mortar Protocols 4-01 Garage Interior: East Wall Fiberboard NYS ELAP Stop at ; 1 Protocols First Positive Disposition of Samples: Accept Reject _ . _ Explain I Comments: Relinquished Bs': 4� Received By: Date: rime: -- -' Page 1 of 1_ 438 New Kamer Road • Albany New York 12205• Phone (518)250-4047• Fax (518)250-4353•email craigpigalpineenv.cam AL.,...,,telict > e / 6(1 I 8 OrderID: 031823166 Pace 2 Of „(4). ni . ,..:. colic.22.)(, -: NJIPUNMENI4I SERVICES CHAIN OF CUSTODY = - I Client: Alpine Environmental Services. Inc. Prqiect: 26 South Western Avenue 438 New Karner Road Glens Fails,New Yori, Albany.NY 12205 Projcxt Number: 18-23084-A Contact: Brian Gould Sampled By: Brian'Gould E-Mail: BrianO@IAlpineEnv.com nv'.com _ Date' Time Collected:8-22.201817:30-9:30 Turnaround Time: 72 hours Shipper Tracking Number: 7955 4825 8844 (fedex) Log No. Sample Sample Location Sample Material Analysis 1 Resul!s No. Performed I 4-02 Garage Interior: East Wall Fiberboard NYS FLAP Protocols r 5-01 Kitchen 12" Self Stick NYS ELAP Stop at Floor Tile Protocols First Positive 5-02 Kitchen I_" Self Stick 1 NYS ELAP I Floor Tile Protocols 61v1-01 Bathroom Linoleum Mastic NYS ELAP Stop at Protocols First Positive 6M-02 Bathroom I inolet+m Mastic NYS FLAP Protocols 6-01 Bathroom I inoleum NYS ELAP Stop at `t` Protocols First Positive 6-02 Bathroom Linoleum _ NYS ELAP Protocols 7-01 West Room Mastic NYS ELAP Stop at On Concrete Floor Protocols First Positive 7-02 West Room Mastic NYS FLAP On Concrete I loor Protocols 8-01 Garage Interior: South Wall Asphalt Siding NYS ELAP Stop at. i Protocols First Positive 8-02 Garage Interior: South Wall Asphalt Siding _, NYS ELM' Protocols v 8A-01 Garage Interior: South Wall Asphalt Siding NYS FLAP Stop at Vapor Barrier Protocols First Positive Disposition of Samples: Accept.__ Reject —Explain Comments: + Relinquished 13v: I Received tiy: Date: I ime: '-gil-/-12P-1-7 ,627.t.-.17 ....---- 7/4.-e-. K- <-_-_-_,-) S.a..-- /3 9 '3)41ivl Page 2 of 4 438 New Karner Road •Albany New York 12205• e (518)250-4047•fax. (518)250-4353 a email craigp@alpineenv-com _.- -� -, / 2 k. / h 8 OrderID: 031823166 Page 3 Of WA . lime ENVIRONMENTAL SERVICES CHAIN OF CUSTODY _. - Client: Alpine Environmental Services. Inc. Project: 26 South Western Avenue 438 New Kamer Road Glens Falls,New York Albany,NY 12205 Projoct Number. 18-23084-A Contact: Brian Gould Sampled By: Brian Gould E Mail: BrianUitAlpineEnv.com Date ' lime Collected: 8-22-2018/7:30-9:30 'turnaround Time: 72 hours Shipper Tracking Number: 7955 4825 8844 (fedex) Log N . sample I Sample Location I Sample Material Analysis Results No. Performed 8A-02 Garage Interior. South Wall Asphalt Siding 1 NYS ELAP Vapor Barrier --I Protocols . _ 9-01 Basement Windom (ila/iiii..: , NYS FLAP Stop at Comp;wad -t. Protocols First Positive 9-02 Basement Window Glazing ' 1 NYS ELAP ir Compound 1 Protocols 9A-01 Exterior: Window Glazing I- NYS ELAP Stop at East Side at Living Room Compound 1 Protocols First Positive 9A-02 , Fxterior Window Glazing NYS OAP East South at Attic Compound Protocols 10-01 Main Roof Roof Shingle NYS EI.AP Stop at ...-- Protocols First Positive 10-02 Main Roof Roof Shingle 1 NYS ELAP - Protocols 10A-01 Main Root Root Shingle NYS ELAP Stop at Vapor Barrier ---' Protocols First Positive I 0A-02 Main Roof Roof Shingle NYS ELM Vapor Barrier ' Protocols - wr 11-01 West Roof Vapor Barrier ......_ NYS ELM' Stop at Under Metal Protocols First Positive 11-02 WCSI Roof Vapor Barrier -- NYS ELAP Under Metal Protocols 12-01 South Attic: on Original Roof Roll Rooting --.. NYS ELAP Stop at Protocols First Positive I Disposition of Samples:Accept Reject Explain Comments: Relinquished By: Received By: Date: ' I ime: /r)1 Pli _,/7 Z/ ta '/' f// ----/ ' '-- ' --<- '-• ^ '.-i ' . , 2 , / Page --) of 7 43R New Kamer Road • Albany New York 12205 • hone.(518) -4047.Fax:(518)250-4353 a email c.raigo@atpineenv corn 8 OrderID: 031823166 Page 4 Of 11 . Ipne ENVIRONMENTAL SERVICES _ — CHAIN OF CUSTODY . , . .. -.- - I Chem: Alpine Environmental Services„Inc. Project: 26 South Western Avenue 438 New Kamer Road Glens Falls,NO)*York Albany,NY 12205 -- Projcct Number. 18-23084-A Contact: Brian Gould Sampled By: Brian Gould E-Mail: BrianGla'AlpineEnv.com Date i Time Collected: 8-22-2018 /7:30-9:30 Turnaround Time: 72 hours Shipper Fracking Number: 7955 4825 8844 lfedext Log N . Sample Sample Locution Sample Material Analysis Results No. Performed 12-02 South Attic: on Original Roof Roll Roofing NYS ELAP — Protocols I 12A-01 I South Attic: on Original Roof Roll Roofing NYS ELAP Stop at Vapor Barrier ' Protocols First Positive 12A-02 South Attic:on Original Roof Roll Roofing NYS FLAP Vapor Barrier ---- Protocols 13-01 Main Roof: At Block Chimney Flashing Tar/Cement NYS ELAP Stop at -- Protocols First Positive 13-0? Smith Roof Overhang Flashing Tar/Cement NYS El AP at(iable Wall Protocols 14-01 West Roof: Al Metal Chinine 1 Flashing Caulk NYS ELAP Stop at 1 Protocols First Positive 14-02 West Roof: At Metal Chimney Flashing Caulk — NYS ELAP Protocols . , Disposition of Samples: Accept Reject Explain Commerns: Rr e ' uished By: ' Received B . i vatic ''',4,'401-&11 'I Zk2 g .1, '- -/ / I 7,o' ...• - ,.... -- :5\- ) ( -.' \2 c 1 ,› 344-1-1 Page g of (7 438 New Karner Road •Albany New York 12205 • Phone (518)250-4047• Fax (518)250-4353•email craigp@alpineenv.com _, at rt r•46.o/t (:.:E => —C------ - --I3 i i ' EMSL Analytical, Inc. EMSL Order: 031828618 Customer ID: ALPI50 307 West 38th Street New York,NY 10018 Customer PO: Tel/Fax:(212)290-0051/(212)290-0058 Project ID: nrtr v,vnv EMSL corn'rnanhattanlab@emsl_com Attention: Alpine Environmental Services Phone: (518)250-4047 438 New Karner Road Fax: Albany, NY 12205 Received Date: 10/16/2018 10:31 AM Analysis Date: 10/17/2018 Collected Date: 10/12/2018 Project: 18-23084-A/26 SOUTH WESTERN AVENUE, QUEENSBURY Test Report:Asbestos Analysis of Bulk Material Non-Asbestos Analyzed Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 01-01 Description SIDE ROOM-CERAMIC FLOOR TILE 031628618-0001 Homogeneity Homogeneous PLM NYS 198.1 Friable 10/17/2018 Brown 2.00%Cellulose 30.00% Gypsum None Detected 58.00% Non-fibrous(other) 10.00% Quartz PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 01-02 Description SIDE ROOM-CERAMIC WALL TILE 0318286/8-0002 Homogeneity Homogeneous PLM NYS 198.1 Friable 10/17/2018 Brown/Tan 100.00% Non-fibrous(other) None Detected PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 02-01 Description SIDE ROOM-CERAMIC WALL TILE GROUT 031828618-0003 Homogeneity Homogeneous PLM NYS 198.1 Friable 10/17/2018 Gray 20.00%Gypsum None Detected 65.00% Non-fibrous(other) 15.00%Quartz PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 02-02 Description SIDE ROOM-CERAMIC WALL TILE GROUT 031828618-0004 Homogeneity Homogeneous PLM NYS 198.1 Friable 10/17/2018 Brown 15.00% Ca Carbonate None Detected 40.00% Non-fibrous(other) 45.00% Quartz PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Initial Report From:10/17/2018 21:03:00 ASB 198x 0009 0001 Printed 10/17/2018 9:03:05PM Page 1 of 3 • EMSL Analytical, Inc. EMSL Order: 031828618 307 West 38th Street New York,NY 10018 Customer ID: ALPI50 TeVFax:(212)290-0051/(212)290-0058 Customer PO: http ilwww EMSL.com/manhattanlab©emsl.com Project ID: Test Report:Asbestos Analysis of Bulk Material Non-Asbestos Analyzed Test Date Color Fibrous Non-Fibrous Asbestos Sample ID 03-01 Description SIDE ROOM-CERAMIC WALL TILE MORTAR 031828618-0005 Homogeneity Homogeneous PLM NYS 198.1 Friable 10/17/2018 Gray 20.00% Ca Carbonate None Detected 55.00% Non-fibrous(other) 25.00% Quartz PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 03-02 Description SIDE ROOM-CERAMIC WALL TILE MORTAR 031828618-0006 Homogeneity Homogeneous PLM NYS 198.1 Friable 10/17/2018 Gray 55.00% Non-fibrous(other) None Detected 45.00% Quartz PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB Not Analyzed TEM NYS 198.4 NOB Not Analyzed Sample ID 04-01 Description BATHROOM-SHOWER ADHESIVE 031828618-0007 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 10/17/2018 White 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 10/17/2018 White 100.00% Other None Detected Sample ID 04-02 Description BATHROOM-SHOWER ADHESIVE 031828618-0008 Homogeneity Heterogeneous PLM NYS 198.1 Friable Not Analyzed PLM NYS 198.6 VCM Not Analyzed PLM NYS 198.6 NOB 10/17/2018 White 100.00% Other Inconclusive:None Detected TEM NYS 198.4 NOB 10/17/2018 White 100.00% Other None Detected • ( Initial Report From:10/17/2018 21:03:00 Printed 10/17/2018 9:03:05PM Page 2 of 3 EMSL Analytical, Inc. EMSL Order: 031828618 Customer ID: ALPI50 307 West 38th Street New York,NY 10018 Tel/Fax:(212)290-0051/(212)290-0058 Customer PO: http,,www.EMSL,com i manhattaniab@emsl.corn Project ID: Test Report:Asbestos Analysis of Bulk Material The samples in this report were submitted to EMSL for analysis by Asbestos Analysis of Bulk Materials via NYS ELAP Approved Methods.The reference number for these samples is the EMSL Order ID above. Please use this reference number when calling about these samples. Report Comments: Sample Receipt Date: 10/16/2018 Sample Receipt Time: 10:31 AM Analysis Completed Date: 10/17/2018 Analysis Completed Time: 8:53 PM Analyst(s): k-176-134( Jon Williams PLM NYS 198.1 Friable(3) Krystal Harris PLM NYS 198.1 Friable(3) --X41-/;/<'14124 Yolanda Chow PLM NYS 198.6 NOB(2) Genevieve Trapani TEM NYS 198.4 NOB(2) Samples reviewed and approved by: ��' James Hall,Laboratory Manager or Other Approved Signatory NOB=Non Friable Organically Bound N/A=Not Applicable VCM=Vermiculite Containing Material -In New York State,TEM is currently the only method that can be used to determine if NOB materials can be considered or treated as non-asbestos containing. All samples examined for the presence of vermiculite when analyzed via NYS 198.1. -NYS Guidelines for Vermiculite containing samples are available at http://www.wadsworth.org/labcert/elapcertforms/VermiculitelnterimGuidance_Rev070913.pdf EMSL maintains liability limited to cost of analysis.This report relates only to the samples reported above and may not be reproduced,except in full,without written approval by EMSL.EMSL bears no responsibility for sample collection activities or analytical method limitations.Interpretation and use of test results are the responsibility of the client. Samples were received in good condition unless otherwise noted. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST,or any agency of the federal government.This report may contain data that is not covered by the NVLAP accreditation. Samples analyzed by EMSLAnalytical,Inc.New York,NY NYS ELAP 11506 • Initial Report From:10/17/2018 21:03:00 Printed 10/17/2018 9:03:05PM Page 3 of 3 ordeAlpine°rnvironmental Services, Inc. Phone: (518) 250-4047 438 New Kamer Road 0 3 7- c-" j S Fax: (518) 250-4353 Albany, NY 12205 CHAIN OF CUSTODY Client: Alpine Environmental Services Project: 26 South Western Avenue.Uueensbury Project Number: 18-23084-A Contact: Mike Balzano Sampled By: Michael Balzano Phone/Fax: michaelb''4alpineenv.com Date / Time Collected: 10/1 2/18 Turnaround Time: 24 Hour _ FedEx Tracking Number: 7 9 X ? 2 5 i 2•0 7 Rr> log No. Sample Sample Location Sample Material Analysis Results No. Performed 01-01 Side Room Ceramic Floor Tile NYS Prot . 5ci 01-02 Side Room t eramic \kali Tile NYS Protocol 02-0l Side Room Ceramic Wall Tile NYS Protocol Grout 02-02 Side Room Ceramic Floor Tile NYS Protocol Grout 03-01 Side Room Ceramic Wall Tile NYS Protocol Mortar 03-02 Side Room Ceramic Floor Tile NYS Protocol Mortar 04-01 Bathroom Shower Adhesive NYS Protocol 04-02 Bathroom Shower Adhesive NYS Protocol • . f e. t)isposition of Samples: Accept Reject Explain Comments: Relinquished By Received By: bate: Time: /.1e,( Page, of r 'I l Page 1 Of 1 New York State—Department of Labor Division of Safety and Health License and Certificate Unit State Campus,Building 12 Albany,NY 12240 ASBESTOS HANDLING LICENSE Alpine Environmental Services, Inc. FILE NUMBER: 00-0320 LICENSE NUMBER: 29095 438 New Karner Road LICENSE CLASS: RESTRICTED DATE OF ISSUE: 07/06/2018 Albany, NY 12205 EXPIRATION DATE: 07/31/2019 Duly Authorized Representative—Craig Petreikis: This license has been issued in accordance with applicable provisions of Article 30 of the Labor Law of New York State and of the New York State Codes,Rules and Regulations(12 NYCRR Part 56). It is subject to suspension or revocation for a(1) serious violation of state,federal or local laws with regard to the conduct of an asbestos project,or(2)demonstrated lack of responsibility in the conduct of any job involving asbestos or asbestos material. This license is valid only for the contractor named above and this license or a photocopy must be prominently displayed at the asbestos project worksite. This license verifies that all persons employed by the licensee on an asbestos project in New York State have been issued an Asbestos Certificate,appropriate for the type of work they perform,by the New York State Department of Labor. • Eileen M.Franko, Director SH 432(8/12) For the Commissioner of Labor NEW YORK STATE DEPARTMENT OF HEALTH WADSWORTH CENTER Expires 12:01 AM April 01, 2019 ; - !ssued April 01, 2018 • - • CERTIFICATE OF APPROVAL FOR LABORATORY SERVICE Issued in accordance with and pursuant to section 502 Public Health Law of New York Stale MR. JAMES HALL NY Lab Id No: 11506 EMSL ANALYTICAL, INC 307 WEST 38TH STREET SUITE 901 NEW YORK, NY 10018 is hereby APPROVED as an Environmental Laboratory for the category ENVIRONMENTAL ANALYSES SOLID AND HAZARDOUS WASTE All approved subcategories and/or analytes are listed below: Miscellaneous Asbestos In Friable Material Item 198.1 of Manual EPA 600/M4/82/020 Asbestos in Non-Friable Material-PLM Item 198.6 of Manual(NOB by PLM) Asbestos in Non-Friable Malerial-TEM Ilern 198.4 of Manual Asbestos-Vermiculite-Containing Material !tern 198.8 of Manual Lead in Dust Wipes EPA 7000B Lead in Paint EPA 7000B Sample Preparation Methods EPA 3051A Serial No.: 57819 Property of the New York Stale Department of Health Certificates aro valid only at the address shown,must be conspicuously posted,and aro printed on secure paper. Continued accreditation depends on successful ongoing panicipatlon in the Program. Consumers are urged lo call(518)485-5570 to verify the laboratory's accreditation status. Page 1 of 1 STATE OF NEW YORK-DEPARTMENT OF LABOR ASBESTOS CERTIFICATE BRIAN H GOULD CLASS(EXPIRES) CATEC(01/19) D INSP(01/19) H PM (01/19) I PD (01/19) MUST BE CARRIED ON ASBESTOS PROJECTS 1,1111111M MINIBMf Division of Safety and Health Engineering Services Unit Department of Labor W. Averell Harriman State Office Campus Building 12, Room 154, Albany, NY 12240 www.labor.ny.gov 518-457-1536 November 13, 2018 Alpine Environmental Services 438 New Karner Road Albany, NY 12205 RE: File No. 18-1511 Dear Sir/Madam: STATE OF NEW YORK DEPARTMENT OF LABOR DIVISION OF SAFETY AND HEALTH The attached is a copy of Decision, dated, 11/13/2018, which I have compared with the original filed in this office and which.I DO HEREBY CERTIFY to be a correct transcript of the text of the said original. If you are aggrieved by this decision you may appeal within 60 days from its issuance to the Industrial Board of Appeals as provided by Section 101 of the Labor Law. Your appeal should be addressed to the Industrial Board of Appeals, State Office Building Campus, Building 12, Room 116, Albany, New York, 12240 as prescribed by its Rules and Procedure, a copy of which may be obtained upon request. WITNESS my hand and the seal of the NYS Department of Labor, at the City of Albany, on this day of 11/1.3/2018. .40, 47400/ Edward A. Smith, P.E. Professional Engineer 2 (Industrial) iy-fiEWYORK Department OPPORTU"'" of Labor STATE OF NEW YORK DEPARTMENT OF LABOR STATE OFFICE BUILDING CAMPUS ALBANY, NEW YORK 12240-0100 Variance Petition Of File No. 18- 1511 Alpine Environmental Services, Inc Petitioner's Agent on Behalf of DECISION Case(s) 1 - 6 Hudson Headwaters Health Network Petitioner ICR 56 in re Premises: Vacant 1-Story Structure 26 S Western Avenue Queensbury, NY 12804 Interior Non-friable Roofing Debris Cleanup & Removal Project The Petitioner, pursuant to Section 30 of the Labor Law, having filed Petition No. 18-1511 on November 5, 2018 with the Commissioner of Labor for a variance from the provisions of Industrial Code Rule 56 as hereinafter cited on the grounds that there are practical difficulties or unnecessary hardship in carrying out the provisions of said Rule; and the Commissioner of Labor having reviewed the submission of the petitioner dated October 25, 2018; and Upon considering the merits of the alleged practical difficulties or unnecessary hardship and upon the record herein, the Commissioner of Labor does hereby take the following actions: Page 2 of 3 File Number 18-1511 Case No. 1 ICR 56-4.9 Denied Case No. 2 ICR 56-7.5(d) Case No. 3 ICR 56-7.8 Denied Case No. 4 ICR 56-7.11(c) Case No. 5 ICR 56-8.2(b) Denied Case No. 6 ICR 56-9.1(c,d) VARIANCE GRANTED. The Petitioner's proposal for interior cleanup of non- friable roofing debris, quantities as stated in the attached proposal, at the subject premises in accordance with the attached 2-page stamped copy of the Petitioner's submittal, is accepted; subject to the Conditions noted below: THE CONDITIONS 1. As written with modifications as noted. 2. A minimum of 8 air changes per hour must be observed once the negative air has been established. A minimum four-hour pre-abatement settling period as per 56-8.2(b) shall elapse once the negative air has been established. 3. All non-porous walls, ceilings, fixtures, and movable and fixed objects contaminated with asbestos debris shall be cleaned as part of this abatement project. All porous materials, debris and waste generated shall be disposed of as per applicable legal methods. 4. After removal and cleanings are complete and a minimum drying period has elapsed, an authorized and qualified Project Monitor shall determine if the area is dry, the scope of work complete, and the work area free of visible asbestos debris/residue. If the area is determined to be acceptable and the aggressive clearance air sample results meet 56-4.11 clearance criteria, the final dismantling of the site may begin. 5. Usage of this variance is limited to those asbestos removals identified in this variance or as outlined in the Petitioner's proposal. In addition to the conditions required by the above specific variances, the Petitioner shall also comply with the following general conditions: GENERAL CONDITIONS 1. A copy of this DECISION and the Petitioner's proposals shall be conspicuously displayed at the entrance to the personal decontamination enclosure. Page 3 of 3 File Number 18-1511 2. This DECISION shall apply only to the removal of asbestos-containing materials from the aforementioned areas of the subject premises. 3. The Petitioner shall comply with all other applicable provisions of Industrial Code Rule 56-1 through 56-12. 4. The NYS Department of Labor Engineering Service Unit retains full authority to interpret this variance for compliance herewith and for compliance with Labor Law Article 30. Any deviation to the conditions leading to this variance shall render this variance Null and Void pursuant to 12NYCRR 56-12.2. Any questions regarding the conditions supporting the need for this variance and/or regarding compliance hereto must be directed to the Engineering Services Unit for clarification. 5. This DECISION shall terminate on November 30, 2019. Date: November 13, 2018 ROBERTA L. REARDON COMMISSI NER OF LABOR By w rd A. Smith, P.E. Professional Engineer 2 (Industrial) PREPARED BY: Ravi Pilar, P.E. Professional Engineer 1 (Industrial) REVIEWED BY: Edward A. Smith, P.E. Professional Engineer 2 (Industrial) 181511 VARIANCE PETITION PROCEDURES FOR ALTERNATIVE WORK PRACTICES Site Wide 26 South Western Ave,Queensbury,NY TABLE OF MATERIALS AND APPROXIMATE QUANTITIES Homogeneous Location Substrate & Approx. Friability Condition Material Accessibility Quantity Roll Roofing Interior of South Wood Roof (12-01. 12-02) Attic, on Old Roof Deck 70 sf Non Friable Damaged Flashing Roof at Masonry Masonry, Tar/Cement Chimney, and Roof Asphalt, 2 sf Non-Friable Damaged (13-01, 13-02) Overhang at Door Wood, Metal BACKGROUND/HISTORY This building is to be demolished. Exterior rooting will be removed following 56 11.6. Answers to Questions 9 and 10 There is hardship in complying with the provisions of the New York State Department of Lahor's Industrial Code Rule 56 due to the type of work being performed. Attic roofing and debris. The only access to this area is from a window. We wish to perform this abatement without a negative pressure containment. This variance petition reflects the necessary work changes needed to accommodate these circumstances. We are specifically requesting relief from the following items of the Industrial Code Rule 56. Attic Rooiint;and Debris (t,�>4 „A� ( e�t c Case# I ICR 56-4.9 Air Sampling Since there will be minimal disturbance and material is non friable we request all work be performed k.,. without the use of air sampling. Visual inspections only by Project Monitor. v���V Case#2 ICR 56-7.5(d) Decons,restricted area Where 25 foot restricted area around decons is not achievable due to site conditions,we request that barrier tape be extended around decons/contaitunents/waste containers to the extent achievable. Page 1 181511 <` 26 South Western Ave,Queensbury.NY t..& - .\(1 V\ 1 ` Case#3 ICR 56-7.8 Engineering Controls ,.1).t „ Since all work will be non friable, while the building is vacant, we propose that this abatement work be ,,\`�:-A--' performed without a negative pressure enclosure. Case#4 ICR 56-7.11(0 e) Regulated Abatement Work Area Enclosure Since only non-friable disturbance is expected. we are requesting relief from the requirement to plasticize floors,walls,and ceilings. Asbes os containing materials will be removed using manual wet methods. ' (- 2 C‘,„ j, -� _ Case#5 ICR 56;9 ' Pre-Abatement Settling period N-) '�' ` , / Due to the fact that no negative pressure enclosure is proposed,we request relief from any and all waiting times. We request a no pre-abatement wait time prior to removalcleaning and no post abatement wait. Case#6 ICR 56-9.1 (c),(d) Final Cleanings One thorough final cleaning and a single and no post-abatement settling period due to the absence of a NPE.. PROPOSED PROCEDURES(Answer to Question 11) Part 1-Interior Damaged Rooting in Attic 1-1] The regulated abatement work area(s)shall be established as per the requirements of ICR 56-7.4. Each regulated abatement work area shall remain vacated except for certified workers until satisfactory visual inspection has been obtained. Where 25 foot restricted area around decons/dumpsters is not achievable due to site conditions,we request that barrier tape be extended around decons/containments/waste containers to the extent achievable. 4 i._ ._ iNvc 1-2] Critical barriers only will be established within 25 foot of removal area. 1 'IN\N-3.\\NZ 1-3] A drop cloth will be placed on the floor of the attic after the floor of the attic in the area of roofing is pre-cleaned. Removal will take place using wet methods,and bagged. Fiberglass insulation t within 25 feet of debris will be disposed of as non-friable waste. it..; , ‘c,. `mot. CcrA a„i-.. \\ �3.\ 1-4] Air Sampling will be performed:A remdte small project decon will be used for abatement worker portion of this work. �,,s. v-`,...' ' 1-5] The areas shall be visually c eated by the site project monitor. -114ed:url-clearance shall bet' , ) documented in log book fi�� �1 .\�‘ \,,,, 0^.S ` j J) 438 New Kamer Road•Albany.New York 12205•Phone:(5I8)250-4047 Page 2 of 2