inspectionsINSPECTION WORKSHEET (001690-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0041-2019 Case Module:Permit Inspection Date:Thu Mar 28, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Residential Final Inspection Job Address:Parcel Number:5 LADY SLIPPER DR Queensbury, NY 12804 301.14-1-75 Contact Type Company Name Name Applicant Collette Construction Inc. Granted Permission Cohen, Vance Contractor Collette Construction Inc. Primary Owner Cohen, Vance Checklist Item Passed Comments General Comments NO 3/28/19 New septic tank to handle the additional bedrooms must be installed before C/O can be issued . Grade away from foundation: 6" down, 10' out YES Winter conditions Emergency egress below grade YES Two egress windows in basement and bilco door installed Final Survey Plot Plan NO Arc Fault Breaker Habitable Spaces YES Existing panel As Built Septic System NO New septic tank must be installed before C/O can be issued OK to Issue C/O NO New septic tank must be installed before C/O can be issued Mar 28, 2019 Page (1) Smith, Mark (Inspector) INSPECTION WORKSHEET (SEP-001854-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0041-2019 Case Module:Permit Inspection Date:Thu Apr 4, 2019 Inspection Status:Passed Inspector:Mark Smith Inspection Type:Septic Job Address:Parcel Number:5 LADY SLIPPER DR Queensbury, NY 12804 301.14-1-75 Contact Type Company Name Name Granted Permission Cohen, Vance Applicant Collette Construction Inc. Contractor Collette Construction Inc. Primary Owner Cohen, Vance Checklist Item Passed Comments Building Inspector Notes YES Tank is at 8.5 feet from foundation, 10' set back is required. 4/4/19 septic system approved .1500 gallon tank installed for the additional bedrooms added in basement. Public Sewer Sign-Off NO Soil Type: Loam NO Soil Type: Clay NO Type of Water: Municipal / Well Water NO Waterline separation distance NO Well separation distance NO Apr 04, 2019 Page (1) INSPECTION WORKSHEET (SEP-001854-2019) Checklist Item Passed Comments Well Casing Lengt: 50ft +/-NO Absorbtion Fields: Total Length YES Existing Septic tanks & pump station anchored in flood zone NO Length of Each Trench NO Depth of Trenches NO Size of Stone NO Seepage Pits: Number NO Size:NO Stone Size:NO Building to Tank NO Tank to Distribution Box NO Distribution box to Field / Pit NO Opening Sealed:NO End Cap NO InletOutlet Pipes & Baffles NO Apr 04, 2019 Page (2) INSPECTION WORKSHEET (SEP-001854-2019) Checklist Item Passed Comments Manholes 12 or less below grade NO [Provide extension collar if Yes]NO Locations / Separations NO Foundation to Tank YES 10' Foundation to Absorption NO Existing Separation of Pits NO Conforms as per Plot Plan NO Engineer Report and As-Built NO ETU Maintenance Contract provided NO Location of system on property NO Front yard System Use Status YES Ok Apr 04, 2019 Page (3) Smith, Mark (Inspector) INSPECTION WORKSHEET (001662-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0041-2019 Case Module:Permit Inspection Date:Thu Mar 28, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Residential Final Inspection Job Address:Parcel Number:5 LADY SLIPPER DR Queensbury, NY 12804 301.14-1-75 Contact Type Company Name Name Contractor Collette Construction Inc. Granted Permission Cohen, Vance Primary Owner Cohen, Vance Applicant Collette Construction Inc. Checklist Item Passed Comments General Comments NO 3/28/19 New septic tank to handle the additional bedrooms must be installed before C/O can be issued . Grade away from foundation: 6" down, 10' out YES Winter conditions Emergency egress below grade YES Two egress windows in basement and bilco door installed Final Survey Plot Plan NO Arc Fault Breaker Habitable Spaces YES Existing panel As Built Septic System NO New septic tank must be installed before C/O can be issued OK to Issue Temporary C/O NO Mar 28, 2019 Page (1) INSPECTION WORKSHEET (001662-2019) Checklist Item Passed Comments OK to Issue C/O NO New septic tank must be installed before C/O can be issued Mar 28, 2019 Page (2) Smith, Mark (Inspector)