Loading...
2009-283 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE (.3""U" OCCUPANCY Permit Number. P20090283 Date Issued: Monday, November 30, 2009 This is to certify that work requested to be done as shown by Permit Number P20090283 has been completed. Location: 22 HONEYSUCKLE Ln Tax Map Number. 523400-226-019-0002-023-000-0000 Owner. ROBERT & SUZANNE SUPPLY Applicant: ROBERT & SUZANNE SUPPLY This structure maybe occupied as a: Garage Detached By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Entorcernent Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090283 Application Number. A20090283 Tax Map No: 523400-226-019-0002-023-000-0000 Permission is hereby granted to: ROBERT& SUZANNE SUPPLY For property located at: 22 HONEYSUCKLE Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ROBERT & SUZANNE SUPPLY Garage Detached $10,000.00 22 HONEYSUCKLE Ln LAKE GEORGE,NY 12845-0000 Total value $10,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-283 768 sq ft garage (Original garage will be closed in) $76.80 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday,July 06,2010 (If a longer period is requited,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T eerry �opday,July 06, 2009 SIGNED BY d for the Town of Queensbury. Director of Building Code nforcement ^2 FFICE USE ONLY D .QI �j TAX MqF NO. PERMIT NO. 0 JUN 2 4 209g FEE PAID BLDG.&CODES APPROVAL , OWN OF QUEENSBURY _____________________________________________ ,.. __eulLUNG&CONS""', ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER: �) L INSTALLER/BUILDER: ADDRESS: ZG ffND 94 Ile A. ADDRESS: PHONE NOS. Y�� ` b( M31 PHONE NOS. LOCATION OF PROPERTY: SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: 34in t, AS ,d ooe HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? ❑YES ❑ NO IF SO,INDICATE APPLICATION NO.AND DATE OF APPROVAL: ESTIMATED COST OF CONSTRUCTION: ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? /I/D IF YES,PLEASE LIST: 7� CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: sr ND PROPOSED PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT SQ.FT. SQ.FT. SQ.FT. FT.&IN. OPEN PORCH DECK 3 SEASON,COVERED OR ENCLOSED PORCH* BOATHOUSE BOATHOUSE WITHSUNDECK ' ) ' f �17 6,4&4:7p IL DOCK C� r / SHED J POLE BARN t DETACHED GARAGE(NO.OF CARS:) OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO] REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested i Queensbury Building & Code Enforcement - Residential F' al Inspection Offi No. (518)761-8256 Arrive: Z-3D a am/pm Date Inspection request received: inspector's Initial . NAME: MIT#: �yC LOCATION: ATE: TYPE OF STRUCTURE: Comments: N A 4' Building Number Address visible from road Chimney,Height I'B'Vent/Direct Vent Location / Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches ®V , Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs decks atlas more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off 2posed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight §Lfej glazft/Window in stairwells saMty glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Baftery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 .ft.--I50 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve s installed/Heat Tra Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A'Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fire roofi /%hour fire door/door closer Duct work Sealed pmporly Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer De . Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Oka to issue C/C or C 10 Tem ra /Permanent E WPV Wdl �1 �tr rJL:1Building&Codes FormtslBuilding&Codes\lnspecion FormsWesidenbal Final Inspection Formcoc;Revised flX January 7,2008;Revised 6/26/08 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE ELECTRICAL APPROVAL Permit No...(ff...—:—L 771 2 11223Cut-in Card No..................................... ...... ...... .... Owner.................R........ iopCert. .... .............................................................................. .. ...... ... 5"e- 4,4=- Z-A/. .............. Installation Consisting -6 .................. .................V.......................... .....................j...................................................................... .................................................................................................................................................................................... InstalledBy.......5]44.-M.�.........................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shallke promptly made for inspection. k. Inspectors of this Company shall have the privilege of-ma irv- ujspec_t ions at any time, and if its rules are violated,the Company shall have the right to r this I fii�ate .......................... Date...//�3.70.1............... INSPECTOR............. ..... ............................................. Menber N.F.P.A.,I.A.E.I. /�-5 nsbu Buildin & Code Enfor en - e ' enti I al ection Quee ry g Office No. (518) 761-8256 Arrive: p rt: ?2f /pm Date Inspection request received: Inspector's Initia NAME: ✓V P IT#: LOCATION: E: ' TYPE OF STRUCTURE: Comments: 4° Building Number Address visible from road '- le Y-1 t;�i Chimney Height/°B°Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches \43L Roof Co late/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above rade g' Guard at stairwell at 34 inches or more Guard at deck porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches of Deck Bracing/Handicapp2d Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off ex sed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Saglazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Bpttn backup, Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access i sq.ft:150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%'Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer ` Duct worts Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if r Okay to issue C/C ® ra /P anent Vol LABuilding&Codes Forms\Buiiding&Codes\Inspection FonnsWesidential Final Inspection Forrn_revise0_100405.doc;Revised January 7,2008;Revised 6/26/08 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date In Queensbury Building &Code Enforcement Arrive: r 742 Bay Road, Queensbury, NY 12804 Inspector's Ini Pt- NAME: PERMIT LOCATION: j INSPECT ON: 3 a TYPE OF STRUCTURE: Y N A COMMENTS: Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jadc Posts/Main Beams Exterior sheeting nailed properly 12'O.C. Headroom 6 ft. 8 in. Stairweft 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each we Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on enter Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour _ Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forrns-OWSulding&CodesUnspedion FoonslFcaning Fang inspection Report.doc Revised January 7,2000 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date In equest received: Queensbury Building &Code Enforcement Arrive: _ am/pm De rt: am/pm 742 Bay Road, Queensbury, NY 12804 lnspecto s I NAME: v L� PERMIT#: `2� LOCATION: L INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 18 gagge 8 16D nails each side stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. W 5.7 sf above/below grade 5.0 sf grade LABuilci ft&codes Forms-OLD\BuildbV&CodesUnspecxion FomisTrarnina FiresMppiny inspection ReporLdoc Revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date"tion request received: Queensbury Building&Code Enforcement Arrive: UJI,6, am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: L/ NAME: PERMIT#: LOCATION: INSPECT ON: 7-2 2-0 `3 TYPE OF STRUCTURE: Comment Y N NA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement O nC Materi or this on site. Foundation/Wallpour ace Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Bullding&Codes Fonms\Buiiding&Codesunspectlon Fonns\Foundation Inspectlon Report.doc Last printed 12/20/2005 9:24:00 AM %��- Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: _am/ m Depart: _ 1 ' am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials NAME: PERMIT#: ---� {� LOCATION: ,INSPECT ON: TYPE OF STRUCTURE: Comm n Y N N/A Footings Monolithic Sl gircanifnt in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofmg Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. y L:\Building&Codes Forms\Building&Codes\lnspectlon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM