2009-283 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE (.3""U" OCCUPANCY
Permit Number. P20090283 Date Issued: Monday, November 30, 2009
This is to certify that work requested to be done as shown by Permit Number P20090283
has been completed.
Location: 22 HONEYSUCKLE Ln
Tax Map Number. 523400-226-019-0002-023-000-0000
Owner. ROBERT & SUZANNE SUPPLY
Applicant: ROBERT & SUZANNE SUPPLY
This structure maybe occupied as a:
Garage Detached By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Entorcernent
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20090283 Application Number. A20090283
Tax Map No: 523400-226-019-0002-023-000-0000
Permission is hereby granted to: ROBERT& SUZANNE SUPPLY
For property located at: 22 HONEYSUCKLE Ln
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: ROBERT & SUZANNE SUPPLY
Garage Detached $10,000.00
22 HONEYSUCKLE Ln
LAKE GEORGE,NY 12845-0000 Total value $10,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans &Specifications
2009-283
768 sq ft garage
(Original garage will be closed in)
$76.80 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday,July 06,2010
(If a longer period is requited,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T eerry �opday,July 06, 2009
SIGNED BY d for the Town of Queensbury.
Director of Building Code nforcement
^2 FFICE USE ONLY D .QI
�j
TAX MqF NO. PERMIT NO. 0 JUN 2 4 209g
FEE PAID BLDG.&CODES APPROVAL ,
OWN OF QUEENSBURY
_____________________________________________ ,.. __eulLUNG&CONS""',
ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION
Use this application for any structure other than the Principal Structure (house) to include, but not limited to:
garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-
Sheds/Fences.
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE
ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED
A VALID BUILDING PERMIT.
OWNER: �) L INSTALLER/BUILDER:
ADDRESS: ZG ffND 94 Ile A. ADDRESS:
PHONE NOS. Y�� ` b( M31 PHONE NOS.
LOCATION OF PROPERTY: SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: 34in t, AS ,d ooe
HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? ❑YES ❑ NO
IF SO,INDICATE APPLICATION NO.AND DATE OF APPROVAL:
ESTIMATED COST OF CONSTRUCTION: ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? /I/D
IF YES,PLEASE LIST: 7�
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE:
sr ND PROPOSED
PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT
SQ.FT. SQ.FT. SQ.FT. FT.&IN.
OPEN PORCH
DECK
3 SEASON,COVERED OR ENCLOSED PORCH*
BOATHOUSE
BOATHOUSE WITHSUNDECK ' ) '
f �17 6,4&4:7p
IL
DOCK
C� r /
SHED J
POLE BARN t
DETACHED GARAGE(NO.OF CARS:)
OTHER ACCESSORY STRUCTURE:
*CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO] REQUIREMENTS IF THE
STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge, the statements contained in the application, together with the plans
and specifications submitted, are a true and complete statement of all proposed work to be done
on the described premises and that all provisions of the Building Codes, the Zoning Ordinance,
and all other laws pertaining to the proposed work shall be complied with, whether specified or
noted, and that such work is authorized by the owner. Further, it is understood that I/we shall
submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested
i
Queensbury Building & Code Enforcement - Residential F' al Inspection
Offi No. (518)761-8256 Arrive: Z-3D a am/pm
Date Inspection request received: inspector's Initial .
NAME: MIT#: �yC
LOCATION: ATE:
TYPE OF STRUCTURE:
Comments:
N A
4' Building Number Address visible from road
Chimney,Height I'B'Vent/Direct Vent Location /
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches ®V ,
Roof Complete/Exterior Finish Complete
Platform at all exterior doors _
Handrail 4 or more risers
Guards at stairs decks atlas more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off 2posed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
§Lfej glazft/Window in stairwells saMty glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Baftery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access 1 .ft.--I50 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve s installed/Heat Tra Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'A'Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fire roofi /%hour fire door/door closer
Duct work Sealed pmporly
Gas Loge in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Are Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer De . Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Oka to issue C/C or C 10 Tem ra /Permanent E
WPV Wdl
�1 �tr rJL:1Building&Codes FormtslBuilding&Codes\lnspecion FormsWesidenbal Final Inspection Formcoc;Revised flX
January 7,2008;Revised 6/26/08
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE ELECTRICAL APPROVAL
Permit No...(ff...—:—L 771 2 11223Cut-in Card No.....................................
...... ...... ....
Owner.................R........ iopCert.
.... .............................................................................. .. ...... ...
5"e- 4,4=- Z-A/. ..............
Installation Consisting
-6
.................. .................V..........................
.....................j......................................................................
....................................................................................................................................................................................
InstalledBy.......5]44.-M.�.........................................................Lic.No...................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shallke promptly made for inspection.
k.
Inspectors of this Company shall have the privilege of-ma irv- ujspec_t
ions at any time, and if its
rules are violated,the Company shall have the right to r this I fii�ate
..........................
Date...//�3.70.1............... INSPECTOR............. ..... .............................................
Menber N.F.P.A.,I.A.E.I.
/�-5
nsbu Buildin & Code Enfor en - e ' enti I al ection
Quee ry g
Office No. (518) 761-8256 Arrive: p rt: ?2f /pm
Date Inspection request received: Inspector's Initia
NAME: ✓V P IT#:
LOCATION: E: '
TYPE OF STRUCTURE:
Comments:
4° Building Number Address visible from road '- le Y-1 t;�i
Chimney Height/°B°Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches \43L
Roof Co late/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs deckspatios more than 30 inches above rade
g'
Guard at stairwell at 34 inches or more
Guard at deck porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches of
Deck Bracing/Handicapp2d Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off ex sed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Saglazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Bpttn backup,
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access i sq.ft:150 sq.ft.vents
Bathroom Fans if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%'Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer `
Duct worts Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Are Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if r
Okay to issue C/C ® ra /P anent Vol
LABuilding&Codes Forms\Buiiding&Codes\Inspection FonnsWesidential Final Inspection Forrn_revise0_100405.doc;Revised
January 7,2008;Revised 6/26/08
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date In
Queensbury Building &Code Enforcement Arrive: r
742 Bay Road, Queensbury, NY 12804 Inspector's Ini Pt-
NAME: PERMIT
LOCATION: j INSPECT ON: 3
a
TYPE OF STRUCTURE:
Y N A COMMENTS:
Framing
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly
12'O.C.
Headroom 6 ft. 8 in.
Stairweft 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each we
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on enter
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour _
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forrns-OWSulding&CodesUnspedion FoonslFcaning Fang inspection Report.doc Revised January 7,2000
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date In equest received:
Queensbury Building &Code Enforcement Arrive: _ am/pm De rt: am/pm
742 Bay Road, Queensbury, NY 12804 lnspecto s I
NAME: v L� PERMIT#: `2�
LOCATION: L INSPECT ON:
TYPE OF STRUCTURE:
Y N NIA COMMENTS:
Framing
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 18 gagge 8 16D nails each side
stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. W
5.7 sf above/below grade
5.0 sf grade
LABuilci ft&codes Forms-OLD\BuildbV&CodesUnspecxion FomisTrarnina FiresMppiny inspection ReporLdoc Revised January 7,2008
Foundation Inspection Report
Office No.(518)761-8256 Date"tion request received:
Queensbury Building&Code Enforcement Arrive: UJI,6, am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
L/
NAME: PERMIT#:
LOCATION: INSPECT ON: 7-2 2-0
`3
TYPE OF STRUCTURE:
Comment
Y N NA
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
O nC
Materi or this on site.
Foundation/Wallpour
ace
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Bullding&Codes Fonms\Buiiding&Codesunspectlon Fonns\Foundation Inspectlon Report.doc
Last printed 12/20/2005 9:24:00 AM
%��-
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: _am/ m Depart: _ 1 ' am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials
NAME: PERMIT#: ---� {�
LOCATION: ,INSPECT ON:
TYPE OF STRUCTURE:
Comm n
Y N N/A
Footings
Monolithic Sl
gircanifnt in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofmg
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft. y
L:\Building&Codes Forms\Building&Codes\lnspectlon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM