Loading...
2009-285 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF COMPLIMN- CE Permit Number. P20090285 Date Issued: Wednesday, August 05, 2009 This is to certify that work requested to be done as shown by Permit Number P20090285 has.been completed. Tax Map Number. 523400-308-008-0001-004-000-0000 Location: 7 BURNT HILLS Dr Owner. CHRISTIAN BERNARD Applicant: RICHARD ANDERSON This structure may be occupied as a: Porch By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090285 Application Number. A20090285 Tax Map No: 523400-308-008-0001-004-000-0000 Permission is hereby granted to: RICHARD ANDERSON For property located at: 7 BURNT HILLS Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RICHARD ANDERSON Porch $14,500.00 DENISE W. ANDERSON Total value 7 BURNT HILLS Dr $14,500.00 QUEENSBURY,NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-285 209 sq ft porch $40.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday,July 02, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of ensb T " r ay,July 02,2009 W SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement I--------------- <<<-- ---------------------------------- ,.rlF, G / 07 Z /, OFFICE USE ONLY , DJ-�- E 0 W E, TAX MAP NO, L�/ PERMIT NO. �� ; JUN 2 9 2009 FEE PAID 7 ' 6 BLDG. &CODES APPROVAL , , 0 --------a------------ ------ -----------------a-:------------:--- 0-a TOb1lh]-OF R'� ACCESSORY STRUCTURE BUILDING PERMIT A ODES Use this application for any structure other than the Principal Structure(house)to include, but not limited to: garage, shed, greenhouse,dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.NO PECTIONS WILL E MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER: Lbd AJ INSTALLER/BUILDER::'y{76 e L !ra c,L'�//l o—z a ADDRESS: ,/ v ' ,oyADDRESS: W�ei y/L f_I��(°�7(s S�c PHONE NOS. ISM `f 311 PHONE NOS. "JA a — '79 s Z-- LOCATION OF PROPERTY: ( I/G/ si�.��SG .�( Y SUBDIVISION NAME: 'ej r- LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: vS ESTIMATED COST OF CONSTRUCTION: $I 7° ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? 6 IF YES,PLEASE LIST: Gj � CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: !� PHONE: l _ q,3d sr ND PROPOSED PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT SQ.FT. SQ.FT. SQ.FT. FT &IN OPEN PORCH DECK 3 SEASON,COVERED OR ENCLOSED PORCH* Z® p r BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS:_) OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO]REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge,the statements contained in the application,together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes,the Zoning Ordinance,and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As-Built Survey by a licensed surveyor,drawn to scale, QUESTIONS? CALL 761-8256 OR EMAIL showing actual location of all new construction. codes(cDaueensburV.net I have read and a ee t the above. VISIT OUR WEBSITE FOR MORE INFORMATION www.gueensbury.net Signed Lam" Dated: Z� O Namerritle(Printed) Etc.` o ����w Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 ' Queensbury Building.& Code Enforcement - sidential Final Inspection Office No. (518) 761-8256 Arrive: v - m Lnm Depart- ______amipm Date Inspection request received: Inspector's ini ials: �� NAME: PERMIT#: fJ LOCATION: DATE: TYPE OF STRI UK15- N /A 4' Building Number Address visible from road Chimney Height/'B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairweli at 34 inches or more Guam at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracin /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill late Gas Valve shut-off ex Red I regulator 18 inches above grade Interior privacy I trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety lazin /Window in stairwells safeglazing interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic socess 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 2g.ft.-150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation i insulation Certification Fkxor truss,draft stopping finished basement 1,000 sq.ft. Emernency earess below arade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve R installed/Heat Ira Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Gars e fireproofing/%hour fire door/door closer Dud work Sealedproperly Gas Logo in Sealed or GlAss EFiko—sure Final Electrical Final Sum Plot Pia Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C I C or C 10 Temporary/Permanent L:1Building&Codes FormslBuilding&CodeMinspection FormslResidenbal Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 Rough Plumbing / Insulation 1 pection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: �am/pm rt: am/pm 742 Bay Road, Queensbury, NY 12804 inspector's Initials: 1 NAME: PERMIT #: LOCATION: . - INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.1 for 15 minutes Insulation/Residential Check/Commercial Check Tyyek or Similar Exterior Sealant it Door/Window Sealed ft Insulation g Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing l Insulation Inspection Report Office No. (518) 761-8256 Date Inspectign request received: -7 Ldo I Queensbury Building &Code Enforcement Arrive:I i S am/prn Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: Q% NAME: r � PERMIT##: a"� -C 6 LOCATION: ( INSPECT ON: 0 TYPE OF STRUCTURE: Y N NIA Rough Plumbing/Nail Plates Plumbing Vent i Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head for 15 minutes sidential Check/Commercial Check C'h� ` Similar Exterior Sealant �� Proper Vent, Attic Vent Door/Window Sealed No Insulation Dud/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly I No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing / Insulation I ction Report Office No. (518) 761-8256 Date Inspection requ ece' Queensbury Building &Code Enforcement Arrive:��' a 742 Bay Road, Queensbury, NY 12804 Ins al NAME: PE IT #: LOCATION: INSPECT ON: - TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test n 1� Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping r�— -`b 5 P.S.I r 15 minutesE� T Insulation/ esidential Check i Commercial Check T e imilar Exterior Sealant � T Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly I No duct tape COMMENTS: Rough Plumbing insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008 lu—IL IAL)(_ e Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspectio request received: Queensbury Building &Code Enforcement Arrive:�am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT#: _ LOCATION: INSPECT ON: C> TYPE OF STRUCTURE: Y Framing N I NIA COMMENTS ccess 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D naiis each side Draft stopping 1,000 sq. ft floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping ✓ 4101— leG-1 / Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuiid ng&Codes Forms-01-Muildirg;&CodesYrapedion FomisTrarning F Inspection Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report r� Office No. (518)761-8256 Date I request received: Queensbury Building &Code Enforcement Arrive: % 01amlMm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspect- s Initials._� NAME: 4 a PERMIT LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N NIA COMMENTS: Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nags each side Draft stopping 1,000 sq. ft floor trusses ft. or less on center Ice and water shiel 4 inches from wall 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. W 5.7 sf above/below grade 5.0 sf grade LASuikimg&Codes Fomis-=\Suildirg&CodesYnspedion FonsTramirg F"uestappag Inspection Reportdoc Revised January 7,2006 Foundation Inspection Report Office No.(518)761-8256 Date In on request received: Queensbury Building&Code Enforcement Arrive:l. am/pm� Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector' Initials: NAME: 1 h C�� PERMIT#: 1' / — . LOCATION: ►� INSPECT ON: TYPE OF STRU TURF: Comment Y N N/A Footin Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Fortes\Building&Codes\Inspection Forms\Foundation Inspecction Report.doc Last printed 12/20/2005 9:24:00 AM \U - \ z Framing / Firestopping Inspection Report V-' 0 �� Office No. (518)761-8256 Date Inspection F5�1 Queensbury Building &Code Enforcement Arrive: a rt: 742 Bay Road, Queensbury, NY 12&M Inspector's In NAME: R Lj 0 F—i�C,I. ERMIT#: LOCATION: -7 Rt-', ._.Li i LA, INSPECT ON: �r�j_ TYPE OF STRUCTURE: Y N WA COMMENTS Framing Attic Access 220 x 31Y minimum Jack Studs/Headers Bracing/Bridging )-(Joist hangers XJack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/ w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavq min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. CM 5.7 sf above/below grade 5.0 sf grade L:1Buildmg&Codes Foms-01- Building&CodesUnspection FomsTraming Rostopping Inspection Report.doe Revised January 7,2008 Foundation Inspection Report (�- Office No.(518)761-8256 Date Inspection ue 7 v Queensbury Building&Code Enforcement Arrive: iO m Depart: H t Ip 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: /�� � PERMIT#: „ 2 LOCATION: 01 INSPECT ON: TYPE OF STRUCTURE: Comments Y N NA ootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM s TO SHERMAN ' AVENUE I Ilet Ala y�r lT �rU.�'� � 1 f _Neve of aP St �1lt2 � I Jit3lz 1WHE f I f LANDS OF I MAP REFERENCES EDWARD 4L DURKIN 1. BURNT HILLS SUBDIVISION, DKC HALD/NGS, INC VAN DUSEN & STEVES� LLC I L. 1261 P. 277 LANDS OF LLS, DATED XLY 23, 2001, LAST REVISED JAN. 17, 2002 GEO GE MAW 2. AMENDED SUBDIVISION OF LANDS NOW OR FORMERLY OF GLENS FALLS HOM& I L. 993 P. 83 INC, BY DAVID F. BARRASS L.LS, DATED 2/17/95. J. WARREN COUNTY, TOM OF QUEENSBURY, TAX MAP NO. 308.06, BLOCK 1, � PARCEL NO. 4, L. 3537 P. 132 I jjj F r.; OUNO /R aC \ 52 ON P/P: O 1 J2 — • lfzpIG. o VN-AC IR� ��� f ' UN/T❑oVA I SIDE SETBACK _ 20.00 :-:•_-_-:2 STORY'-: PROPOSED 4211 - -FRAM....... ENCLOSED a -- HOUSE•,-.- PARCH WALK :'.':.'-- - - - 4&0' __ _ o __ REAR SETBACK--..] p I� f :.':.:.:_':::.:.� :.:' LANDS OF Q .ST(Sl�'Y:._. 1 STORY J 8. O.. SO f A� k ��7 f MACADAM I JUTREY & JOAN LEE DRIVE GARAGE.':........HOUSE: TO BENG SHED MOVED I L. 1171 P. 69 O 20.5' � PROPOSED ' MACADAM OR/ICE SHED (13 _ B E SIDE SETBACK BASK et ❑ o HOOP 18ALL — 20.5' 0) x0 CEDAR ROW 20• FOUND CAPPED IRON P r � I /PE I ` LANDS OF RUSSEI.L & DARUWE P"ER f L. 1379 P. 116 I .� I"P of SUR VEY OF LANDS OF LEGEND: RICHARD & DENISE ANDERSON N • FOUND IRON MARKER I J. O SET IRON ROD WITH CAP f TOWN OF CNJEENSBURY, WARREN COUNTY,11; NEW YORK o • Q POI WER LINE ® * * SCALE.• )". = 20' DA 7E: MAY 8, 2009 —STONE WALL UPDATED .NNE 15, 2009 TO ADD PROPOSED r —= -FENCE PORCHES ON THE REAR. ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY I LINO • MARKED WTH AN ORIGINAL OF THE LAND SURVEYOR'S EMBOSSED SEAL OR INKED STAMP SHALL BE W. J. ROURKE, ASSOCIATES CONSIDERED TO BE VALID 1RUE COPIES � O Licensed Land Surve)vrs • Unauthorized Alteration to this map is a 1554--- Saratoga Road, P.O. Box 1434 09-37 violation of Section 7209, Subdivision 2 South Glens Falls, N.Y. 12803 of the New York State Education Law. WILUAM J. RDUR LIC SED LAND SURVEYOR NO. 49098 JOB NO.