Loading...
1.4 r Y i 1.4 SETPH.VAR\Babcock-Replacement System With Absorption Box and Force Main to Lines and Well and Under Driveway-4-1-19 RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL VARIANCE APPLICATION OF THOMAS AND MARYBETH BABCOCK RESOLUTION NO.: ,2019 INTRODUCED BY: WHO MOVED ITS ADOPTION SECONDED BY: WHEREAS, the Queensbury Town Board serves as the Town's Local Board of Health and is authorized by Town Code Chapter 136 to issue variances from the Town's On-Site Sewage Disposal Ordinance, and WHEREAS, Thomas and Marybeth Babcock (Applicants) have applied to the Local Board of Health for variances from Chapter 136 to install a replacement septic system to replace an existing holding tank system as follows: 1. Absorption field to be 4' from the west property line instead of the required 10' setback; 2. Absorption field to be 2' from the south property line instead of the required 10' setback; 3. Distribution box to be 4' from the south property line instead of the required 10' setback; 4. Force main to be 4' from the south property line instead of the required 10' setback; 5. Absorption field to be 68.4' from the neighboring well line instead of the required 100' setback; and 6. Absorption bed to be located partially under the driveway; on property located at 15 Chestnut Road in the Town of Queensbury, NOW, THEREFORE, BE IT RESOLVED, that the Town of Queensbury's Local Board of Health will hold a public hearing on Monday, April 15th, 2019 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road, Queensbury, to consider Thomas and Marybeth Babcock's sewage disposal variance application concerning property located at 15 Chestnut Road, Queensbury (Tax Map No.: 289.13- 1-12) and at that time all interested persons will be heard, and BE IT FURTHER, RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice to neighbors located within 500' of the applicant's property as required by law. Duly adopted this 1st day of April,2019,by the following vote: AYES : NOES : ABSENT: SEWER\Babcock—Replacement with Absorption Box and Force Main to Lines and Well and Driveway—4-15-19 NOTICE OF PUBLIC HEARING IN ACCORDANCE WITH TOWN OF QUEENSBURY ON-SITE SEWAGE DISPOSAL ORDINANCE CHAPTER 136, NOTICE IS HEREBY GIVEN THAT THE TOWN OF QUEENSBURY LOCAL BOARD OF HEALTH WILL CONDUCT A PUBLIC HEARING ON MONDAY, APRIL 15TH, 2019 AT 7:00 P.M. AT THE QUEENSBURY ACTIVITIES CENTER, 742 BAY ROAD, QUEENSBURY TO CONSIDER AN APPLICATION BY THOMAS AND MARYBETH BABCOCK FOR SEWAGE DISPOSAL VARIANCES TO INSTALL A REPLACEMENT SEPTIC SYSTEM TO REPLACE AN EXISTING HOLDING TANK SYSTEM AS FOLLOWS: 1. ABSORPTION FIELD TO BE 4' FROM THE WEST PROPERTY LINE INSTEAD OF THE REQUIRED 10' SETBACK; 2. ABSORPTION FIELD TO BE 2' FROM THE SOUTH PROPERTY LINE INSTEAD OF THE REQUIRED 10' SETBACK; 3. DISTRIBUTION BOX TO BE 4' FROM THE SOUTH PROPERTY LINE INSTEAD OF THE REQUIRED 10' SETBACK; 4. FORCE MAIN TO BE 4' FROM THE SOUTH PROPERTY LINE INSTEAD OF THE REQUIRED 10' SETBACK; 5. ABSORPTION FIELD TO BE 68.4' FROM THE NEIGHBORING WELL LINE INSTEAD OF THE REQUIRED 100' SETBACK;AND 6. ABSORPTION BED TO BE LOCATED PARTIALLY UNDER THE DRIVEWAY; ON PROPERTY LOCATED AT 15 CHESTNUT ROAD IN THE TOWN OF QUEENSBURY, (TAX MAP NO.: 289.13-1-12). AT THIS PUBLIC HEARING ALL INTERESTED PERSONS WILL BE HEARD. PUBLICATION DATE: APRIL ,2019 CAROLINE H.BARBER TOWN CLERK TOWN OF QUEENSBURY 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering Phone: (518)745-0307 Fax: (518)745-0308 March 27, 2019 2 q Q Q . 6, Town of Queensbury, Local Board of Health 4, 0 742 Bay Road CE D o Queensbury, NY 12804 Re: Residence of Thomas and Marybeth Babcock o i of sos .v 15 Chestnut Road, Queensbury CP V. N1 Tax Map ID #: 298.13-1-12 < # 9 ' t'g? Dear Board Members: Attached please find a plan and application for septic variance to allow a replacement septic system to be installed for owners Thomas and Marybeth Babcock at the above-referenced residence. We are seeking relief from property line setbacks as well as separation to a neighboring drilled well. Proposed treatment system will consist of a Clarus Fusion 450 enhanced treatment system, a pump station and 13' x 24' subsurface absorption bed, to replace the existing holding tank system. Every effort has been made to provide a high-quality enhanced treatment system and minimize requested variances. We respectfully request to be placed on the board schedule for the upcoming April meetings. Please contact me if you have any questions or if you require additional information. Best Regards, G. Thomas Hutchins, P.E. Cc: Thomas and Marybeth Babcock SEPTIC VARIANCE Office Use Only Received: APPLICATION Permit#: O\5 O 15 Town of(Vern a iv Permit Fee: Icpt:3 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.queernsbury.net Invoice#: Approvals: Submittal: I original&8 copies of the completed application package Property Owner(s): Thomas&Marybeth Babcock Owner's Agent: Hutchins Engineering Address: 15 Chestnut Road Address: 169 Haviland Road Queensbury,NY 12804 Queensbury,NY 12804 Phone#: (518)469-7048 Phone#: 518-745-0307 Site Address: 15ChestnutRoad Tax ID#: 298.13-1-12 Directions to Site: Distance from well on property to septic system(if applicable) 101 feet Is it possible to install a conforming septic system on this property? Yes X No If YES,please explain and attach a diagram: Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring properties? Yes X No If NO, please explain: See below Is the proposed system to be installed under a parking area? X Yes No Section of the Sanitary Sewage Ordinance from which you are seeking the variance(i.e.leaching system will be 89 ft. from well in lieu of required 100 ft.): Absorption field will be 4'from the West property line in lieu of required 10' Absorption field will be 2'from the South property line in lieu of required 10' Distribution box will be 4'from the South property line in lieu of required 10' Forcemain will be 4'from the South property line in lieu of required 10' Absorption field will be 68.4'from neighboring well in lieu of required 100' Absorption bed to be located partially under driveway Septic Variance Application February 2018 List the names, parcel addresses, and tax map numbers of all adjoining property owners. You may obtain tax map numbers from the Assessor's Office as well as the names and addresses: North Name Robert Napoli Address 13 Chestnut Road Lake George;NY 12845 Tax Map ID 289-13-1-11 South Name Sean P Corrigan Address 17 Chestnut Road Lake George,NY 12845 Tax Map ID 289.13-143 East Name n/a(Glen Lake) - Address Tax Map ID West Name Peter Dineen Address 22 Chestnut Road Lake George,NY 12845 (across the road) Tax Map ID 289.134-39 OWNER STATEMENT I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: 15 Chestnut Road I/We realize that putting the well,septic tank or leaching system less than the required 100 feet from the well may increase the risk of pollution. IM s�Owner—Print Name: ''lac A � 4� r / a-LDate: I-�Owner—Sign e: � -v-z Date: 2x.) / NEIGHBOR OR TENANT RELEASE STATEMENT(if applicable) I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: 15 Chestnut Road I/We realize that putting the septic tank or leaching system less than the required 100 feet from the well may increase the risk of pollution. ai Neighbor/Tenant—Print Name: -e, 1� ( J�� ) r Date: 3 I - 1 9 Neighbor/Tenant-Signature: --' kr-04 ti Date: — — I t Septic Variance Application February 2018 PLEASE ATTACH THE FOLLOWING TO YOUR APPLICATION: 1. A location map showing the site within the Town of Queensbury 2. A plot plan showing existing and proposed features of the property, including: a. Lot dimensions b. North arrow and scale: 1 inch=40 feet c. Location &dimensions of existing and proposed buildings,showing setback distances and uses d. Parking layout to scale (if applicable) e. Physical features(street, steep'slopes, lakes, wetlands, etc.) f. Location of all wells and septic systems on neighboring properties g. Adjacent ownerships h. All properties within 500 feet A sample plot plan and location are shown below: I x � — l •. � - --34r11p*teca7 kt, 41-N " t rr.K#w,.vt „" I 1 i �` f _1.N al i „.., �� ,-„, �e E----V,/ ,, - .f.:*".'''t ij III:111 d,,, p- I1 _ , � `r ;#0.04000.000,-_,, 4; —I f# .A _i , _ � � j i ��'' 1 i IROZORMARR fur - - "- 'may _- u, _ . 3i Septic Variance Application February 2018 AUTHORIZATION AND SIGNATURE PAGE This page includes the Authorization to Act as Agent form,engineering fee disclosure, authorization for site visits, other permit responsibilities and agreement to provide documentation required. Complete the following if the OWNER is using an Agent: Owner's Name: Thomas or Marybeth Babcock Designates: Hutchins Engineering as agent regarding the Septic Variance for Tax Map#: 289.13-1-12 OWNER'S SIGNATURE: DATE: Engineering Fee Disclosure:Applications may be referred to the Town consulting engineer for review of septic design, storm drainage, etc. as determined by the Town Board of Health. Fees for engineering review services will be charged directly to the applicant. Authorization for Site Visits: By signing this page and submitting the application materials attached herein, the Owner,Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted. Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of Health. It is the applicant's responsibility to obtain any additional permits. Officiatial Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the meetings resulting from the application, and that the minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer,the handwritten minutes shall be deemed the official record. I,the undersigned, have thoroughly read and understand the instructions for submission; agree to the submission requirements and completed checklist: OWNER—PRINT NAME: ' Z/7 -� " "C --- OWNER—SIGNATURE: "' c r DATE: �'� 1 AGENT—PRINT NAME: E tNi AGENT—SIGNATURE: DATE: Septic Variance Application February 2018 S81054'45"E 0 OAK - - � — - - — — — - - 181 + F 150.00, l O Q r } zP IGK WALL G" OAK �Q BRF II / BILCO p k E !! WELL O v s , /• I 1 -e Y- r EXISTING � r-t �3 aj. f + 40 NEIGHBORING 3 AK N (]� a '. • .e RESIDENCE � f w • I 16 HEML K I W ' - r�-y 3' • F.P. o 3 C1�,'r: - �` o / I SITE LOCATION AGE 100 TO / t Q .. ' / GAR NEIGHBORING \ y I " BIRCH 1 LOCATION MAP NEIGHBORING WELL o, ll O Cj N APPROXIMATE / a d LOCATION`OF i ;' / d o 2 HEMLOCK / NEIGHBORING _ a ' - 3E M P�5 SYS 45TONE RETAINING'.WALL F 2 Q S814- 45 E /� _ _ _ + Tfl F- - - _ 24 z OAK 45 4, 1 5 _::-.. .. :'. IRE wau__ WALL i o i i NB O WO RET. d SINE r • OAK 68.4' TO 4' WEST NEIGHBORING PROPERTY ASPHALT SURFACE / A WELL LINE SEI$ACK rCCO "q�r .t l O K PROP. CLARUS FUSION 450 / li�LE /� _ J v a' ENHANCED TREATMENT UNIT OAK K e ^ GO�G� 2a OAK 1O1' TO CONC' u N✓ELL �,• \ F•r L L./ XEWELL •_ AS PGR CLIENT PiNe 3 Q / o�'O y�h \ \ DOCk _ ELEVATION 398.94 � � C NC�E 0. GAS V rEXSSTING 2,000 GALLON 1 HOLDING TANK SYSTEM Q I AREA/ SYSTEM MATERIAL SPECIFICATIONS TO BE REMOVED 7,342± sq f t. / � � ABSORPTION BED AGGREGATE es h 0. 17± 4, 3� QO PROP. 500 GALLON N � I i' � � STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. f POLYETHYLENE_ / oo EFFLUENT SEWER PIPE 2 PUMP STATION � 30 0 8 A 'Al PIPING TO BE 4" SOR-35 OR SCH-40 PVC. INSTALL WITH 1/8" PER �NG�RAGE �RL FOOT MINIMUM SLOPE. PT-1 & 4• \wood FORCEMAIN ° PROP FORCEMAIN l j SEPTIC VARIANCE SUMMARY PIPING TO BE 1-1 2" SOR-11 HOPE, PROVIDE POSITIVE DRAINBACK PT-1 ,-. POST FM FM FM FM FM FM �� �� i �'� 1,1't T PROPERTY LINE TO PUMP STATION PROP. 13Wx24 Lx1 D CRUSHED s / 1. ABSORPTION FIELD TO WEST STONE ABSORPTION BED -.. `' 145. 1 ' o 10' REQUIRED HOUSE SEWER PIPE WALL N82°54'45' W v 3� 4' PROPOSED PIPING TO BE 4" SDR-35 SCHEDULE 40 PVC. INSTALL WITH 1/4" IRS ��, " s O STONE!M ONRY WALL STONE �.� ' 0 PER FOOT MINIMUM SLOPE. BRFSTONE W a O2 ti0 RAF 6 OF REU EQU ALL / ESTED � EF R — EEL STABILIZATTON FABRIC s 2. ABSORPTION FIELD TO SOUTH PROPERTY LINE STABILIZATION FABRIC TO BE WOVEN CEOTEX77LE WITH . • N�' - a poo 10' REQUIRED POLYPROPYLENE YARNS, THRACE LING GTF-300 OR EQUIVALENT. •CON@RETE PROP. DIST. BOX l rt7p WALK .4 e l - 2' PROPOSED TOPSOIL < ADjO1NFRs 000K 8' OF RELIEF REQUESTED PLACE 4" MINIMUM TOPSOIL OVER ENITRE BACKFILL AREA. SEED, 4. / ' MULCH, AND ESTABLISH TURF. 1 3. DISTRIBUTION BOX SETBACK TO SOUTH PROPERTY LINE • 2' SOUTH / ' 10' REQUIRED PROPERTY LINE SETBACK EXISTING 4' PROPOSED WASTEWATER SYSTEM DESIGN APPROXIMATE NEIGHBORING 6' OF REUEF REQUESTED 4-BEDROOM RESIDENCE LOCATION OF / RESIDENCE 91' TO / DESIGN FLOW - 110 GPD/BEDROOM SEPTIC SYSTEM NEIGHBORING LANDS N/F OF 4. FORCEMAIN SETBACK TO SOUTH PROPERTY LINE SYSTEM DESIGN FLOW 440 GPD 1 / WELL / ESTATE OF ALICE CORRIGAN 10' REQUIRED �Pp,GE � POTABLE WATER IS 4' PROPOSED REQUESTED SEPTIC TANK - PROP. CLARUS FUSION 450 ENHANCED TREATMENT SYSTEM 8941306 PUMP STA77ON - PROP. 500 GALLON POLYETHYLENE PUMP TANK / 102 TO / LAKE SUPPLY 6' OF REUEF APPLICATION RATE TO EXISTING SOIL: .95 GPD/SF, BASED ON NEIGHBORING WELL 5. ABSORPTION FIELD SETBACK TO NEIGHBORING WELL 1-5 MIN/1N PERCOLATION RATE 100' REQUIRED 68.4' PROPOSED ABSORPTION BED AREA REQ'D = (440 GPD)/(.95 GPD/SF) 31.6' OF RELIEF REQUESTED = 464 SF 33% REDUCTION IN BED AREA FOR AEROBIC TREATMENT UNIT 1 6. ABSORPTION FIELD TO BE LOCATED PARTIALLY UNDER INSTALL BED AREA ABSORPTION REQUIRED BED 31 SF SF / DRIVEWAY SITE SOILS DATA ABSORPTION BED AREA PROVIDED - 13'x24' - 312 SF TEST PIT — — — — — TP-1 - 10130118 BY TOM HUTCHINS, P.E. POTABLE WATER SUPPLY IS TO BE ON-SITE WELL i SYSTEM INSTALLATION NOTES 0-8" - GRAVELLY TOPSOIL CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF 8-74" - YELLOW-BROWN MEDIUM AND FINE HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED SAND, DRY, UNIFORM TUBING IN SEPTIC TANK LEACH FIELDS. ROOTS ENTIRE DEPTH AFTER EXCAVATION OF 13' WIDE X 24' LONG ABSORPTION BED TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR NO SEASONAL HIGH GROUNDWATER EVIDENCE SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL. WELL PERCOLATION TEST PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE PT-1 - 10130118 BY TOM HUTCHINS, P.E. EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE. STABILIZED PERCOLATION RATE: TAX MAP # 289.13-1-12 2 MINUTES 10 SECONDS PER INCH THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES IMTHOUT SAGS, Ding I Safely. HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS. PIPE SHALL BE LAID WITH HOLES DOWN IN ALL NPrWI/YOhk CASES. ■Call Before You Dig ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE MAP REFERENCE: ■wait The Required Time DISPOSAL FIELD. ■Confirm utility Response 1. BASE MAP INFORMATION FROM 'MAP OF A ■Respect The Marks SURVEY MADE FOR THOMAS J. BABCOCK & ■Dig With Care DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING HAS BEEN INSTALLED. MARYBETH T. BABCOCK," IN THE TOWN OF 800-962.7962 0 ISSUED FOR SEPTIC VARIANCE 3/26/2019 QUEENSBURY, WARREN COUNTY NEW YORK. www.cflgWelyneviyork.com DATED MAY 20, 2010. LAST REVISED APRIL 12, N o. Revisions Date THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA 2012• TUBS OR WATER TREATMENT EQUIPMENT. THE INSTALLATION OF NON-CONSERVING WATER FIXTURES OR EXTREME 2. ADDITIONAL INFORMATION FROM "MAP OF A WgSTEWATER SYSTEM PLAN WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM. SURVEY MADE FOR ROBERT J. & BONNIE M. NAPOLI," IN THE TOWN OF QUEENSBURY, prepared for: WARREN COUNTY, NEW YORK. DATED NOVEMBER ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER 22, 2005. LAST REVISED MARCH 11, 2008. Thomas & Marybeth Babcock SYSTEM. BOTH PREPARED BY. 15 Chestnut Road CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF AROUND ABSORPTION Town Of QueenSbury, Warren County, NY FIELD. `I �n �u S Drawn: JRS Checked:GTH Scale: 1"=10' Date: 712812018 S to V e S 169 Haviland Road SEPTIC TANK, PUMP STATION & ABSORPTION BED MUST BE INSPECTED BY TOWN OF QUEENSBURY BUILDING L8I1C1 SurveOrs y INSPECTOR AND DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING. y ALTERATION OF THIS DOCUMENT EXCEPT BY Queensbur , NY 12804 291342-01 -S 1 169 Hatiland Road QueensI New York 128" A LICENSED PROFESSIONAL ENGINEER IS A (518) 745-0307 Phone (518) 792-8474 New York Lic. No. 50135 VIOLATION of NYS EDUCATION LAW. Hutchins Engineering 518 745-0308 Fax RED AIR BLOWER LINE FUSION CONTROL PANEL POWER 84 3/4 0. CORD AIR LINE OUTLET TO PANEL As ADAPTER M INLET OUTLET _ CONDUIT TO J RED AIR PANEL W BLOWER LINE ' I H TYPICAL RISER CONFIGURATION \ RISER AND LID RUBBER � 3�...,.a ...,....�...... ,........__..�..; ELBOWS o L AIR LINE BLUE AIR 00 TO PANEL LINE NOTES: BLUE AIR LINE `R 1) DIMENSIONS "I" AND "E" ARE TO THE BOTTOM OF THE INLET/OUTLET PIPE. 2) THE OVERALL HEIGHT DIMENSION "H" IS TO THE TOP OF THE NARROW a ADAPTER RING, NOT THE RISER LID. CLEANOUT LO LO 3) A RISER COVER COMES STANDARD. ADDITIONAL RISERS ARE - TO DRAIN FIELD "' PURCHASED SEPERATELY. BUILDING SEWER LINE AIR LINES EXCAVATING DIMENSIONS OPTIONAL DECORATIVE ROCK CONFIGURATION O SYSTEM L W H I E FUSION 450 7'-1" 3'-8" 5'-2" 4'-4" 3'-10" FUSION 450 - DIMENSIONS & EXCAVATION DETAILS NTS FUSION TREATMENT UNIT FUSION 450 - TYPICAL PROFILE FUSION 450 - AIR PUMP DETAILS NTS NTS TYPICAL INTERIOR CONFIGURATION LIMIT OF 13'x24' 4" PERFORATED SDR-26 PVC LATERALS AIR PUMP DETAILS STONE BED INSTALLED NEAR LEVEL IN BED CONFIGURATION PROPOSED NTS �--^ �-- :. ^- --- „—., DISTRIBUTION BOX TRANSITION FORCE 1 1/2" TOP COURSE ASPHALT 5 MAIN TO 4" PVC OUTSIDE OF D-BOX 3.5 - 2" BINDER COURSE ASPHALT 13 � ' 1 _ s C0 00� �00 0 o O o GRANULAR SUBBASE COURSE NYS DOT ' 12" MIN o 0 0 0 C 0 0 0 0 SECT. 304. TYPE 2 OR 4 12 5' oO o O OD �� COMPACTED TO 959 STD. PROCTOR r r 0 0 �', 1 5 , 24' SUBGRADE COMPACTED TO ABSORPTION BED PLAN 909a STANDARD PROCTOR NTS ASPHALT PAVEMENT DETAIL NTS APPROXIMATE ASPHALT DRIVE EXISTING GRADE Doff 13' BED WIDTH n- 2' MIN. USABLE SOIL EXTERIOR WEATHERPROOF JUNCTION BOX IF NECESSARY). BACKF7LL MATERIAL AS NEEDED 13'x24' CRUSHED STONE ( ) TO ESTABLISH GRADES ABSORPTION BED SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN POLYETHYLENE EXTENSION TO POLYETHYLENE EXTENSION HOUSE. ALL ELECTRICAL WORK TO BE INSPECTED BY A GRADE WITH TAMPER TO GRADE WITH TAMPER CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO ABSORPTION BED SECTION RESISTANT ACCESS COVER RESISTANT ACCESS COVER START—UP OF PUMP STATION. NTS (NON—TRAFFIC AREAS) (NON—TRAFFIC AREAS) TRANSITION TO 4" 12" MIN. COVER OUTSIDE OF D—BOX DISTRIBUTION BOX 12" GRAVEL SUBBASE OVER BED 1 4 PER FOOT BALL VALVE ASPHALT DRIVE APPROXIMATE MIN. SLOPE 1/8" PER FOOT BAFFLE ®� AREA, BELOW ASPHALT PAVEMENT OU R MIN. SLOPE 1-1/2" USE SPEED LEVELERS TO 2" MIN. 4 EFFLUENT SEWER FORCEMAIN ASSURE ALL OUTLETS ARE AT �orE 24' BED LENGTH si.o�� EXISTING GRADE EXACTLY THE SAME ELEVATION l " .; ~ ,>Y:f X'L..,'c�c.�k r' . ta ; .;s ... i..P i�, ,£ r c•Llt +� ¢r:`'�s � X 4 4 PVC SDR-35 SOLID HEADER ALARM 3" ABOVE TO ABSORPTION LATERALS, 1/8" r 'PUMP ON' PER FOOT MIN SLOPE PUMP ON 1-1/2" SCH-40 PVC OR GALVANIZED PUMP OFF PIPING INSIDE WET WELL THROUGH WALL 4" SDR-26 PVC PERFORATED ABSORPTION BED PROFILE GEOTEXTILE STABILIZATION "� __ UNION - LOCATE SUCH THAT UNION LATERAL INSTALLED NEAR FABRIC EXTENDING 3' VOLUME OF DOSE TO 6 M �� CAN BE DISCONNECTED AND PUMP LEVEL, IN BED CONFIGURATION NTS BEYOND EDGES OF STONE BE 80t GALLONS REMOVED WITHOUT TANK ENTRY CLARUS FUSION 450 TREATMENT TANK 500 GALLON REDUCING TEE POINTED DOWNWARD WITH (SEE DETAILS) FLOAT SWITCHES — POLYETHYLENE 1" BALL VALVE THROTTLED TO ALLOW INSTALL INSIDE PUMP PIT PUMP STATION TRICKLE DRAIN BACK INTO WETWELL IN LOCATION ACCESSIBLE INSTALL FLOAT SWITCHES TO BALL CHECK WITHOUT PIT ENTRY OPERATE PUMP AND MAINTAIN VALVE LEVELS AS INDICATED GOULDS WE05H PUMP Dig Safely, New/.York Dig CLARUS FUSION 450 TANK & PUMP STATION DETAIL 0 Beforell he R You ®Waft The Required Time NTS ®Confirm speet The�Mark Dose 0 Dig With Care 800-%2-7962 0 ISSUED FOR SEP71C VARIANCE 312612019 www.digsafeiynewyork.com No. Revisions Date WASTEWATER SYSTEM DETAILS prepared for: Thomas & Marybeth Babcock 15 Chestnut Road Town of Queensbury, Warren County, NY Drawn: JRS Checked: GTH Scale: NOTED Date: 712812018 169 Haviland Road ALTERA110N OF THIS DOCUMENT D(CEPT BY Queensbury, NY 12804 291342-01-S2 A UCENSED PROFESSIONAL ENGINEER IS A (518) 745-0307 Phone VIOLATION of NYS EDUCATION LAW. Hutchins Engineering 518 745-0308 Fax