Loading...
RC-0155-2019 TOWN OF QUEENSBURY 742 Bay Road, Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0155-2019 Tax Map No: 309.17-1-2.1 Permission is hereby granted to: Michael Altare For property located at: 92 EAGAN RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Michael Altare Single Family-Addition $261000.00 Owner Address: 92 Eagan RD Total Value $261000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Honey-Do Man LLC 442 CORINTH RD Queensbury,NY 12804 Plans& Specifications Residential Addition 480 s.f. (bedroom) $250.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,April 13, 2020 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Friday,April 12, 2019 SIGNED BY. for the Town of Queensbury. Director of Building&Code Enforcement .l , 4 Office Use Only >' : ADDITION/ALTERATION PERMIT Permit#: fZC ` O f S 5 ` ?ol ci -- APPLICATION Pem,i� e S U_ Cw To4cn of(Zuecnsbun �/ it .� _C 742 Bay Road,Queensbury,NY 12804 E C rnvoicc tik: >0 P:518-761-8256 www.queensbury.net MAR 2 7 2019 Project Location: CID CV04) TOWNOFG&CODES ENSBURY Tax Map ID #: 5ja , rk - r — 2.., , 4 ,, ame: CONTACT INFORMATION: • Applicant: Name(s): tkIle-t 4- -k.(1 gtic eZ.t_. Mailing Address, C/S/Z: ak1i,A Ny IZ$01-1 Ga EcxcI&A Q.d Cell Phone: ( 551B ) 1Ci1 -33'-iis Land Line: ( ) 4 E m a i I: 9 tAkalkk,iite caw.. • Primary Owners): Name(s): 14 aLSl.. Mailing Address, C/S/Z: a E un ea Q o 1JY 12, aq Cell Phone: (5lP ) lql - 3,�WQ, Land Line: ( ) i Email: 9Gwt0.k @ tar). ❑ Check if all work will be performed by homeowner only • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): gOi\at- co ian Contractor Trade: 0.04\413i.c\10(1 Mailing Address, C/S/Z: t-(t.U... Cx t, -`1 2_ 8 gSIan 1\1\( I2f )`-{ Cell Phone: ( `J1$ ) 2_(90 - yS16 Land Line: ( ) Email: hp -& �nr\ e\,,,„,,,,,A lo+,, **List alradditional contractors on the back of this form • Architect(s)/Engineer(s): Business Name: AKCti\Sv_x tko` t Contact Name(s): )caN AkoAk Mailing Address, C/S/Z: 11y"b,,y AvL (k rvs '\\3 MN/ )ZSto1 Cell Phone: ( ) +-iIA Land Line: ( SIg ) -7q / -62(0�, Email: e,Pl>a.�1 e t1yCoP .('('. Contact Person for Building & Code Compliance: 1(EV1u /tv`( & Cell Phone: (5 t8 ) 21,1,6 - -I'3 Land Line: ( ) �t�i4 Email: Y1 o r�l,k) .do ,�c&n e h4.„a,l .Co,N• Addition/Alteration Application Revised February 2019 • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: Addition/Alteration Application Revised February 2019 r it t PROJECT INFORMATION: TYPE: Commercial )c Residential WORK CLASS: XSingle-Family Two-Family Multi-Family (# of units Townhouse Business Office Retail Industrial/Warehouse Garage (# of cars ) Other (describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: W 1st floor: 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement (habitable space):Ipp �,, Basement (habitable space): Total square feet: `'1W Total square feet: ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ au )(5730 2. If Commercial project, what is the proposed use: 13. Source of Heat (circle one): Gas Oil Propane Solar Other hl Fireplaces need a separate Fuel Burning Appliances & Chimney Application 4. Are there any structures not shown on the plot plan? YES NO Explain: 5. Are there any easements on the property? YES NO�; 6. SITE INFORMATION: vt a. What is the dimensions or acreage of the rcel? _off . b. Is this a corner lot? YES NO c. Will the grade be changed as a result of the construction? YES NO, d. What is the water source? PUBLIC PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? AkC.r Addition/Alteration Application Revised February 2019 - DECLARATION: 1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: CL -/ -7e4 SIGNATURE: /�� '/ DATE: ]\2___(Ji \q Addition/Alteration Application Revised February 2019 4 Highland Ave, a P a:n 90 Queensbury, NY 12804 Phone: 518-798-0793 Fax: 5 i$-798-48b2 Precisfi®w l www.lapansprecision.com EXECUTIVE DIVISION -) ;. CA April 11, 2019 APR122019 of ow RE: 92 Eagan Road, Queensbury BUILDING& To Whom It May Concern: The Burnham oil boiler model V-73 with net I=B=R rating of 105 MBH will adequately heat existing home and new addition. Providing the new addition is equipped with its own zone and thermostat control. Sincerely, Kevin Sumner BHL Enterprises, LLC dba LaPan's Precision Page 1 of 1 [ � tEDlI , 0 REScheck Software Version 4.6.3 MAR 2 9 2019 Compliance Certificate TOWN OF QUEENSBURY BUILDING&CODES REVIEWED FOR Project Residential Addition ENERGY CODE COMPLIANC Energy Code: 2015 IECC Location: Glens Falls, New York Construction Type: Single-family FILE COPY Project Type: Addition Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 92 Eagan Road Michael Altare Ethan Peter Hall Queensbury, NY 12804 92 Eagan Road Rucinski Hall Architecture Queensbury, NY 12804 134 Dix Ave Glens Falls, NY 12801 518-741-0268 ephall@nycap.rr.com Compliance: Passes using UA trade-off Compliance: 3.4%u Better Than Code Maximum UA: 88 Your UA: 85 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling 1: Raised or Energy Truss 480 49.0 0.0 0.020 10 Wall 1: Wood Frame, 16" o.c. 216 21.0 3.6 0.046 9 Window 1: Wood Frame:Double Pane with Low-E 14 0.290 4 Wall 2: Wood Frame, 16" o.c. 180 21.0 3.6 0.046 7 Window 2: Wood Frame:Double Pane with Low-E 28 0.290 8 Wall 3: Wood Frame, 16" o.c. 216 21.0 3.6 0.046 8 Window 3: Wood Frame:Double Pane with Low-E 14 0.290 4 Door 1: Solid 20 0.300 6 Basement Wall 1: Solid Concrete or Masonry 190 0.0 15.0 0.051 10 Wall height: 7.9' Depth below grade: 6.0' Insulation depth: 7.5' Basement Wall 2: Solid Concrete or Masonry 158 0.0 15.0 0.051 8 Wall height: 7.9' Depth below grade: 6.0' Insulation depth: 7.5' Basement Wall 3: Solid Concrete or Masonry 190 0.0 15.0 0.051 9 Wall height: 7.9' Depth below grade: 6.0' Insulation depth: 7.5' Window 4: Vinyl/Fiberglass Frame:Double Pane with Low-E 6 0.290 2 Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence - Eagan Road\Altare.rck Page 1 of10 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.3 and to comply with the mandatory requiremen isted in t RES ck Inspection Checklist.Ethan Peter Hall-Architect •C 0 g4g. !�/�,, (J Name-Title Signa ure,;_ , Date ,, f Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence-Eagan Road\Altare.rck Page 2 of10 , 0 REScheck Software Version 4.6.3 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section ; Plans Verified Field Verified & Re ID Pre-Inspection/Plan Review Value i Value Complies? Comments/Assumptions q . 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the Location on plans/spec:A- building envelope.Thermal ❑Not Observable 1 envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ElComplies Requirement will be met. 103.2, documentation demonstrate ❑Does Not I403.7 energy code compliance for Location on plans/spec:A- [PR3]1 lighting and mechanical systems. [Not Observable 1 Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]z on loads calculated per ACCA Cooling: Cooling: Location on plans/spec: A- Manual] or other methods Btu/hr Btu/hr [Not Observable 1 approved by the code official. ❑Not Applicable Additional Comments/Assumptions: I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence - Eagan Road\Altare.rck Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 1 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R- R- ❑ table for values. insulation is used, verification Does Not may need to occur during ENot Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies Requirement will be met. [FO5]1 insulation installed per ❑Does Not manufacturer's instructions. Location on plans/spec: A- " 'Not Observable 1 ENot Applicable 402.2.9 Conditioned basement wall ft ft ElComplies See the Envelope Assemblies [FO611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. [Not Observable ❑Not Applicable 303.2.1 A protective covering is installed UComplies Exception: Requirement is [F01l]2 to protect exposed exterior ❑Does Not not applicable. I insulation and extends a minimum of 6 in. below grade. ENot Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is [FO1212 controls installed. ❑Does Not not applicable. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence- Eagan Road\Altare.rck Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.lD i _ 402.1.1, Door U-factor. U- U- EComplies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ['Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- EComplies See the Envelope Assemblies ! 402.3.1, average). ❑Does Not table for values. 402.3.3, ' 402.3.6, ['Not Observable i 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products EComplies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ['Not Observable Location on plans/spec: A- taken from the default table. 1 ENot Applicable — 402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. Location on plans/spec:A- ❑Not Observable 1 ENot Applicable 402.4.3 Fenestration that is not site built EComplies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ENot Observable 400 that do not exceed code ENot Applicable limits. i 1402.4.5 IC-rated recessed lighting fixtures EComplies Exception: Requirement is '[FR16]z sealed at housing/interior finish ❑Does Not not applicable. and labeled to indicate <_2.0 cfm leakage at 75 Pa. ENot Observable ENot Applicable 403.2.1 Supply and return ducts in attics EComplies Exception: Ducts located [FR12]1 insulated >= R-8 where duct is EDoes Not completely inside the >= 3 inches in diameter and >= building envelope. R-6 where < 3 inches.Supply and Not Observable return ducts in other portions of ENot Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as EComplies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not ENot Observable Location on plans/spec: A- ❑Not Applicable 1 i 403.4 HVAC piping conveying fluids R- R- EComplies Exception: Requirement is [FR17]z above 105°F or chilled fluids ❑Does Not not applicable. below 55°F are insulated to?._R- ['Not Observable 3. ENot Applicable 403.4.1 Protection of insulation on HVAC EComplies Exception: Requirement is [FR24]1 piping. ❑Does Not not applicable. =_ ENot Observable ENot Applicable 403.5.3 Hot water pipes are insulated to R- R- ElComplies Exception: Requirement is [FR18]2 >_R-3. ❑Does Not not applicable. [Not Observable ENot Applicable ___ 403.6 Automatic or gravity dampers are EComplies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. Location on plans/spec: A- ❑Not Observable 1 ENot Applicable I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence- Eagan Road\Altare.rck Page 5 of10 • Additional Comments/Assumptions: 1 L High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence - Eagan Road\Altare.rck Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value ! Value Complies? Comments/Assumptions & Req.ID i 303.1 All installed insulation is labeled ❑Complies Requirement will be met. [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable l ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.E wall insulation on the wall [IN3]1 exterior,the exterior insulation ❑ Mass ❑ Mass ❑Not Observable requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies Requirement will be met. [IN4]1 manufacturer's instructions. ❑Does Not Location on plans/spec: A- ❑Not Observable 1 ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence - Eagan Road\Altare.rck Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 1 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ENot Observable 402.2.6 [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every ['Not Observable Location on plans/spec: A- 300 ft2. 1 ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies Requirement will be met. [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that Location on plans/spec:A- extends over insulation. ❑Not Observable 1 ❑Not Applicable 402.2.4 Attic access hatch and door R- R- EComplies Requirement will be met. [F13]1 insulation __R-value of the ❑Does Not adjacent assembly. Location on plans/spec: A- ❑Not Observable 1 ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies Requirement will be met. [F117]1 ach in Climate Zones 1-2, and EDoes Not <=3 ach in Climate Zones 3-8. ❑Not Observable Location on plans/spec: A- 1 ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies Exception: All ducts and air [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not handlers are located within <=3 cfm/100 ft2 without air [Not Observable conditioned space. handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 EComplies Exception: All ducts and air [F127]1 determine air leakage with ft2 ft2 ❑Does Not handlers are located within either: Rough-in test:Total conditioned space. leakage measured with a ['Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of • test. Postconstruction test:Total leakage measured with a i pressure differential of 0.1 inch I w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies Exception: Requirement is [F124]1 by manufacturer at<=2%of ❑Does Not not applicable. design air flow. ❑Not Observable ❑Not Applicable ..I 403.1.1 Programmable thermostats EComplies Requirement will be met. [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and Location on plans/spec: A- initially set by manufacturer to 1 code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed EComplies Exception: Requirement is [FI10]2 on heat pumps. ❑Does Not not applicable. ['Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies Exception: Requirement is i[FI11]2 systems have automatic or ❑Does Not not applicable. accessible manual controls. 1 ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) j 3 Low Impact(Tier 3) Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence- Eagan Road\Altare.rck Page 8 of10 Section I I Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies Exception: Requirement is 1[FI25]2 fans not part of tested and listed ❑Does Not not applicable. HVAC equipment meet efficacy and air flow limits. ['Not Observable ENot Applicable 403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is [F126]2 through one-or two-pipe heating ❑Does Not not applicable. systems have outdoor setback control to lower boiler water [Not Observable temperature based on outdoor ENot Applicable temperature. 403.5.1.1 Heated water circulation systems EComplies Exception: Requirement is [F128]2 have a circulation pump.The ❑Does Not not applicable. system return pipe is a dedicated return pipe or a cold water supply ENot Observable pipe. Gravity and thermos- ENot Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is 1[F129]2 comply with IEEE 515.1 or UL ❑Does Not not applicable. 515. Controls automatically adjust the energy input to the ENot Observable heat tracing to maintain the ENot Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies Exception: Requirement is [FI30]2 have recirculation pumps that ❑Does Not not applicable. pump water from a heated water supply pipe back to the heated ['Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies Requirement will be met. [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side [Not Observable Location on plans/spec: A- pressure loss of drain water heat 1 recovery units< 3 psi for ENot Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies Requirement will be met. [F16]' fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. ['Not Observable Location on plans/spec: A- Does not apply to low-voltage 1 lighting. ENot Applicable 1404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met. 1 [F123]3 no continuous pilot light. ❑Does Not ENot Observable Location on plans/spec:A- 1 ENot Applicable l 1 lHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence - Eagan Road\Altare.rck Page 9 of10 Section Plans Verified Field Verified Final Inspection Provisions i Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. ❑Complies Requirement will be met. [F17]2 ❑Does Not ['Not Observable ❑Not Applicable 303.3 Manufacturer manuals for EComplies Requirement will be met. [F11813 mechanical and water heating ❑Does Not systems have been provided. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: Residential Addition Report date: 03/29/19 Data filename: Y:\Honey-Do Man\Altare Residence- Eagan Road\Altare.rck Page 10 of10 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 24.60 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.30 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments