Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2009-364
0111111IIIK TOWN OF QUEENSBURY 742 Ba Road ueensbu NY 12804-5902 518 761-8201 _ Y ,Q rY> � ) Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20090364 Date Issued: Thursday, October 31, 2013 This is to certify that work requested to be done as shown by Permit Number P20090364 has been completed. Location: 25 SMOKE RIDGE Rd Tax Map Number: 523400-308-008-0001-021-031-0000 Owner: JMC PROPERTIES Applicant: JMC PROPERTIES This structure may be occupied as a: Fireplace By Order of Town Board Garage Attached TOWN OF QUEENSBURY Townhouse '_.p / Issuance of this Certificate of Occupancy DOES NOT relieve the property � ' .n owner of the responsibility for compliance with Site Plan, Variance, or V/ other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY EiT742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090364 Application Number. A20090364 Tax Map No: 523400-308-008-0001-021-031-0000 Permission is hereby granted to: JMC PROPERTIES For property located at: 25 SMOKE RIDGE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JMC PROPERTIES P.O.BOX 684 Fireplace GLENS FALLS,NY 12801-0000 Garage Attached Townhouse $75,000.00 Total Value $75,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-364 1564 SQ FT TOWNHOUSE WITH 576 SQ FT GARAGE & 1 FIREPLACE $276.56 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday,August 24, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To Queensb on I,•y,August 24, 2009 SIGNED BY for the Town of Queensbury. Director of Building&Z e nforcement ,"- � [.... yP\J�E//oF/`jiCE USE ONLY i5CEOVIE °nV TAX MAP NO PERMIT NO (ii---(_,)6,;N : _______4_ FEES: PERMIT RECREATION ENGINEERING i JUL 3 0 2009 ' 1 (If applicable) ;' ,, , TOWN OF QUEENSBURY PRINCIPAL STRUCTURE: BUILDINGCODES APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: L,�1 iY0'''''' ..t_ (, r l (...i7,1:Yr,C,OWNER: c.) r, Pc 0 „. k., 4 ADDRESS: .�k�p..,.),.: m G L( 1 . c 'C,� C' 3 \/ ADDRESS: P O, r. ;' , PHONE NOS t, ,; t .-. PHONE NOS.\t d '� It , ""0? .. ,4' CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: " lt .. PHONE3 1.' ?,0 LOCATION OF PROPERTY6" , A ; ' g,T < :;; .- . ; . - A ‘, SUBDIVISION NAME: ,''; rf 0 11,C `, . ; ..,:1.,°1.7 71 Y 'CI U , ..‘ °_,.1,', t c N, PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR O cc ci o F PROJECT z Q xO 0 t4 " w f- w OLL gLL w .i 02= w 0 _a o I Q OYz Z C! ►-� OF= CCw- Z Q < cn N cn O u- I—LL a 2 625 SINGLE FAMILY TWO-FAMILY MULTI-FAMILY(NO. ) TOWNHOUSE ,, _ , t BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED „? GARAGE(1,2,3) V I OTHER 10T.011 Of Qllreusbu7v- C0PPI'iili'f?7€t1/ 1LC'Z'e€`C'=Muni Cyfice 74 "'Lay -Ali ' C # Qi .e('llt t ,', ,t iL8,Ji� o tt, IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: I/1 ESTIMATED CONSTRUCTION COST: i t` FUEL TYPE: t c HEAT TYPE r ` '` ,' ' "HOW MANY FIREPLACE(S) 1 AND I OR WOODSTOVES(S): i. ZONING CATEGORY: (SP.. 1 A ARE THERE WETLANDS ON THIS SITE? N 0 IS THIS A HISTORIC SITE? Ni moo. o PROPOSED USE OF BUILDING OR ADDITION: :t,'AA ....-- t`r ° TO t^,. )tt o k..'° ` ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? N to ARE THERE EASEMENTS ON PROPERTY? IN 0 *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the abo e. 1,1 Signed ( t t �"1. .._ : 1 Director of Building & Codes: 7 1 2 3 (for questions Qf UESTIONS? CALL 761-8256 OR EMAIL regarding Building Permits, construction codes or septic codes queen burv.nat systems) N VISIT OUR WEBSITE FOR MORE INFORMATION www.queensburv.net __,--- Zoning Administrator: 761-8 218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) This application/proposed action described Permission is hereby granted to the above herein is found to be in accordance with the Applicant to erect or alter the building described zoning Laws of the Town of Queensbury. herein in accordance with said Application: F � , '7),/'- '°\?_:9 F F F F t f F t �i ii ZONING APPROVAL DATE B LDING&CODES APPROVAL AT w.=s.-m_ > s,-n.r+-v o s_ n r,. r n_A s_ ✓.+r s a r_x n ._n . n__ r r._ n e a .v...-r r«_c 9 r . _r n r.-...m_ m.... _n n r r 7 1 C r �C�, d E Comp aF�?u� E_ r .._��'�9t2C. - ;. .cd, c.51 1a 1g, Y 12804 Town of Oueenshuri. Michael F. Travis Highway Highway Superintendent Home. (518) 798-0413 Department 742 Bay Road Queensbury, NY 12804 Thomas R. Varmess f` ry Deputy Superintendent Office Phone: (518) 761-8211 711 t I©;��e (�18) ?4� 09?9 Fax: (518) 745-4466 DRIVEWAY PER IT DATE: APPLICANT NAME: C i TELEPHONE NO.: i ci ADDRESS TO BE INSPECTED: ),,S -940 ke dAr RETURN ADDRESS: Po box (541 NN Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary Approval NEED: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( )12„ ( )15" ( )18" ( )24„ ( )36„ Preliminary inspection completed by: Date: Approval by Highway Supt: Deputy Supt:. Upon completion, please resubmit this approved permit for a final approval STEP 2. ( ) Final Approval ) Rejected Date: Michael f: Travis, Highway Superintendent -- Thomas as R. Van Ness, Deputy Highway Superintendent For an EPA homeowner's guide: hffp://www.epa.gov/nodes/pubs/homeowner guide long customize.pdf OFFICE USE ONLY TAX MAP NO. PERMIT NO. PERMIT FEE APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: JMC Properties INSTALLER: Cifone Construction Co. Inc. ADDRESS: P.O. Box 684,Glens Falls, NY, 12801 ADDRESS: P.O. Box 684,Glens Falls, NY 12801 PHONE NOS. 518 615-0066 PHONE NOS. 518 792-9242 LOCATION OF INSTALLATION:.25' Smoke Ridge Road,Queensbury, NY 12804 NO.OF RESIDENCE YEAR BUILT BEDROOMS X COMPUTATION= = TOTAL DAILY FLOW INFORMATION: 1980 or older X 150 gallon per bedroom = 0 GARBAGE GRINDER INSTALLED? 1981-1991 X 130 gallon per bedroom = 0 1992-present 2 X 110 gallon per bedroom = 220 SPA OR HOT TUB INSTALLED? PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING ✓ STEEP SLOPE SLOPE ✓ SOIL NATURE: SAND ✓ LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? 51" BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL ✓ WELL (If well:water supply from any septic system absorption is:( ft) ✓ PERCOLATION TEST: RATE IS 1" PER MIINUTE PER INCH(TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: 1000 GALLON(MIN.SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: ❑ABSORPTION FIELD(WITH NO.2 STONE) Total length ( ft. Each trench X 2. B ❑SEEPAGE PIT(S)(WITH NO. 3 STONE) How many? Size? Q�ALTERNATIVE SYSTEM Bed or other type? ❑HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOSE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree QUESTIONS? CALL 761-8256 OR EMAIL to abide by these and all requirements of the Town of Queensbury codes(7a,queensbury.net Sanitary Sewage Disposal Ordinance. VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net 2 2--7 09' i_nature of Person l ponsiblc D e i' Town of Queensbury n Community Development Office © 742 Bay Road, Queensbury, NY 12804 „ raps . . _.as Fire Marshal's Office Town of Oaaeeiashaary - 742 Bay Road a Ouecr!sbur?J, New York -12804 i a Michael I. Palmer, Fire Marshal. Gary Stillman, Deputy Fire Marshal o a o a r r a>>s-r a,e a a v s_a=v a a APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS Application is hereby made to the Building &Codes Office for the issuance of a Building & Use Permit pursuant to the New York State Fire Prevention &Building Code. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations,and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED. OWNER: L► c c r . 0.4ACe L iac.. INSTALLER/BUILDER: Ci eat Ccr 1 C ADDRESS: ` '� 7bON Ca'iSel en 1 4 ADDRESS: ?0 BOX (.e).4 a 9 PHONE NOS. 19 l a. .eir p� PHONE NOS. 9 rk- LOCATION OF PROPERTY: R.Ay za SUBDIVISION NAME: t 11 LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION. _ Y1ry® �%r41 F . CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:CNn PHONE: e�61” O(r ✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL INFORMATION STOVE FIREPLACE INSERT FIREPLACE,FACTORY BUILT* jy6 FIREPLACE,MASONRY FURNACE (GARAGE ONLY) *IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: pC MODEL NO.CWS % O V''5 A414 LISTED BY: L1--. NUMBER: QUESTIONS? CALL 761-8205 or 761-8206 CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL: firemarshai(queensI ury.net MASONRY** CHECK ONE ✓ VISIT OUR WEBSITE TILE STEEL SIZE IN FOR MORE INFORMATION INCHES queensbEwry.net FLUE CHECK ONE V. DOUBLE CHIMNEY TRIPLE WALL INSULATED DIRECT VENT WALL LINER CHIMNEY MATERIAL CHECK ONE ✓ **IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME:` ° ;Ii4. IT MODEL NO. "I 121\E311kS ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION& BUILDING CODE AND/OR MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. 3 IN 6A LA Queensbury Building & Code Enforcement - Residential Final Inspection, 1\-\� Office No. (518) 761-8256 Arrive: am/pm De•art/ ) am/pm Date Inspection request received: Inspector's Initials: ; NAME: PERMIT#: 0 I _) ( ,4(/ LOCATION: te. : Vl, DATE: t \'-4:)` \ TYPE OF STRUCTURE: Comments: _Yes No N/A 4" Building Number Address visible from road C. ;. ' L. Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 'l 1 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors ? Every level: Every Bedroom: Outside every bedroom area: ��� �..7� Inter Connected: _ Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler _Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum' "Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent]. L:\Building&Codes Forms1Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08; Revised 12/22/10,Revised 04/13/11 > �L_ -\N Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart: /�• /1 am/pm Date Inspection request received: 1� � 'i��'p q � Inspector's Initials: NAME: 0rt):( . C i " . PERMIT#: 36,4 LOCATION: ., S ok-e lore frL�- DATE: �n ', )o :? l3 TYPE OF STRUCTURE: ' .�t.krr� / t""- Comments: Yes,.No N/A 4" Building Number Address visible from road f- c� Chimney Height/"B"Vent/Direct Vent Location l ��r'� Fresh Air IntakeclA_, .-`� -� �, [4 � 3 inch Plumbing Vent through roof minimum 18 inches ✓ C-(�, C1 a-S Roof Complete/Exterior Finish Complete Y 1� �C_ 0 Platform at all exterior doors 13 Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more V Guard at deck,porches 36 inches or more A Handrail Termination at Newell Post or Wail 47KGi 1 l C V1 Interior/Exterior Railings 34 inches to 38 inches Y Deck Bracing/Handicapped Ramp Compliant V (.L Grade away from foundation 6 inches with 10 feet /:„, 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade ! Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Win w in stairwells safety gla g Interior Smoke De ors I Carbon onoxid etectors Every level: Eve / CD Bedr om: /every bedroom ea: v Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area / `5 41 Crawl Spaces 18 inch x 24 inch access,1 sq.ft:150 sq.ft.vents / t 1 V�.� Bathroom Fans,if no window `/ , 1�,t-1➢ `�Z _Plumbin fixtures / Foundation insulation to floor I Sticker on Panel V-C-- VC 2.3-V (g...-- -121-t, ,- Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. / Emergency egress below grade z V Z.. ''-(Is,3 � � Gas Furnace shut-off within 30 feet or within line of site ,,/ ,� �- ,,�.�-°,.[-��L)2 Oil Furnace shut-off at entrance to furnace area �Nj�- Furnace/Hot Water Heater operating l C . `" Low water shut-off boiler 1/ (tK)v_5-- Zt ,p�\Relief Valve(s)installed/Heat Trap/Water-Temp 110 e° �iEnclosed Stairs Sheetrock Underside minimum'/Z"Gypsumtf "-- Basement stairs closed rise>4 inches A,,/ c::; ;1::$ �) &c Garage Floor Pitched ��h Garage fireproofing/3/hour fire door/door closer V Z C)1) [,.- e J•• v` Gas Logs_in_Sealed or Glass Enclosure Vaal Electrical nergy Saving Light Bulbs 50% i Final Survey Plot Plan r'`"fZ—_ Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding 16.N., -V 6z- % �t�/"�--d 4A '' As Built Septic System/Sewer Dept. Inspection Sticker N Site Plan /Variance required — Flood Plain Certification, if required d(...� Okay to issue C/C or C I 0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-8511 October 24, 2013 Project#47345 Mr. Craig Brown Zoning Administrator, Code Compliance Officer Town of Queensbury 745 Bay Road Queensbury,NY 12804 Re: Cifone Construction—25 Smoke Ridge Road—Stormwater Management Dear Mr. Brown: We have inspected the site work for 25 Smoke Ridge Road and find that all associated sitework for stormwater management has been completed for this lot as per the approved site plan drawings with the latest revision date of 8-22-12. Please feel free to contact me if you have any questions. Sincerely, Thomas R. Center Jr., P.E. cc: John Cifone — Cifone Construction Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart:<= t am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: � ,_;_:� c NAME: C�1"tM'E PERMIT NO.: -'�7 " LOCATION: 72-c____ 1-4.4-'7r 17.-.i)C, INSPECT ON: RECHECK: -� Comments and/or diagram Soil Type: an Loam/Clay Type of Water: Municipal/ Well Water Waterline separation distance __ ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y N N/A [150'to well required if NO] _ rk 5 Absorption Field: Total length ft. ����� �� � Length of each trench ft. Depth of trenches - ft. a Size of Stone _ _ _ Seepage Pits: Number �'`� Size: Stone Size: tDir Piping Size Type Building to tank '`' AtO Tank to Distribution Box i 1614 3 "--. J Distribution Box to Field/ Pit t 44; Opening Sealed: y_ N End Cap Y T N Inlet/Outlet Pipes&Baffles t�N Manholes 12"or less below grade _Y_ N [provide extension collar if Yes] Y_ N P Location/ Separations Foundation to tank 10 ft. ')� �� (� Foundation to absorption �.c ft. f"' V " Separation of Pits /J//eft. k Conforms as per Plot Plan _ Engineer Report and As-Built _Y /If -Cr ETU Maintenance Contract _Y— N � r provided I eJ la Location of System o Property: �� Front Rear Left Side Right Side Middle Front Middle Rear S stem Use Status: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report_03 29 10.doc RX Date/Time 04►04IZ013 11:33 b1 is c/.1 r cuc r .....�, .—/TAp r. 4. 2013 11 33 v ' No. 9170 P. 4/5�� AM' MD IA, Water liet, NY' ��`, 0MIDDLE DEPARTMENT INSPECTION AGENCY, INC. k`c as <<%� ceer' .that the electrical wiring to the electrical equipment listed below has been examined and is approved `P 6 ) beingin accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date ; s (ca) 4,) noted below and is issued subject to the following conditions. P7 1.tk Owner we iry:) JMC Properties Date: 03/27/2013 Occupant: Same Location: � 4 t� 25 Smoke Ridge Road try' �`�) ,,y) Occupancy: Queensbury,Warren Co. NY 74 <<?) Single Family Dwg- �<j Applicant.. :y Cifone Construction f>:.:F:,;:;. :.,::':, ,.... trePz lee�) PO Box 684 :;: , "<'> fk.`- ; '= -;$" ..,' ,i ` Glens Falls, NY 12$Q1°�'p,:;,, '•., "• 4 Jose h A.l-'iolmes f,:s::,'.'• '''�Y. -'�"'`.r�t.1/0,c1- .`.X;:`•.i;4-.;,.;; `r5�.,,�i.;....>. '\. NI. 440055 1J �.y'}` y,` "= k.f, i .. .. .. ���� <?) Equipment: :t x:_::; �: ' ;::.. �r'7:,:rt_;` ',.>;; 6:<:;. 6 • 0) `; ::...::, A`>,:<,.' _,.-. '' Water Heater; 1 Air 150 -Amp. Service Equipment 2/0;'31 v-Switches; 39 f eceptacles:46 Fixtures; 1•-::Range;q<1 0,1 Conditioner; 1 - Burner, Wiring &Controls Gas; 1 - Dishwasher; 1 -Dryer; 1 -20 Amp: Receptacle Washer; 2-Vent I/•'>)gs. Fans; 5-Smoke Detectors ,, ... :.,.. C/t -+ •is .., •Y,. \U : :. :3 }. ' .:. s ' CCU) .. 0 lb (s This certificate applies to the electrical wiring to the electrical equipment listed Immediately null and void. This certificate applies only to the use,occupancy and .r�%� Is0 above and tha Installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership (try) inspection. No warranty is expressed or implied as to the mechanical safely,elf.- of the property indicated above,this certificate shall be immediately null and void. (0)) Clc ciency or Illness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, tti` ` ,, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department �n. 1w') system to which this certificate applies be altered In any way,Including but not limit- Inspection Agency,inc. An application for inspection must be submitted to Middle 't�) 64 ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc. to initiate the Inspection and revalidation `I� .,) any of the components installed as of the above noted date,this certificate shall be process. A fee will foe charged for this service. �.,�� gc� :v vpi 1ii� :r•--Y:�::�-. Fy•'. r'. irs7i rivii, eiogis zw.4 1,ii",y,ti:sii Si,2',N- ,:.,; } yx,; —;:—�7�'�ii�?si;ViFiY, » G':�':L.•=L:L✓c�.��.�!�!:`.?��:.;.<:!.••..v �`.•4.✓,ti✓,-✓wg✓.r✓.`�v,��=�!<L!ti=�<:r%%L=`!Lc�•s>,:•:v';`:•>c.:'a::S:�r��4.3.`e?t`v_v',.:1y=tiaLti✓.%vwi-=_r'�� APR 0 4 2013 � ids L -1 Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart:. am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:ett NAME: „ PERMIT #: 09-.3 l 0 I LOCATION: L s ;,rr{C INSPECT ON: Agq TYPE OF STRUCTURE: . - s.— Y N N/A I Rough Plumbing / Nail Plates Plumbing Vent I Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping r- \\ Air/Head 50 P.S.I for 15 minutes f t\insulation /Residential Check/Commercial Check --) 1Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent , Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: `, `1) -f- I, tNE)& Via-- c el A-)-i\AkAi\f? e___ I-Ltc--,$ uketkit•-- -- Rough Plumbing Insulation Repart.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ •: Queensbury Building &Code Enforcement Arrive -C C a if• o - • . /pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials T _ NAME: C t rQ — P IT ##: C c'.- 2 LOCATION: 5 S m v e INSPECT ON: TYPE OF STRUCTURE: i c Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above hi k hest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes.S/ Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant _ Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape — COMMENTS: Ff\Vev_ t �� . EEpIj -VO c 6�i\VL_E ) To FEE TR-05 Rough Plumbing Insulation Report.revised Nov 17 2003, revisedFebruary 15,2+14, _ January 7,2008 17")/AsotaK g - ID Framing / Firestopping Inspection Repo Office No. (518)761-8256 Date Inspection request received: 5 t Queensbury Building &Code Enforcement Arrive: am/pm Depa m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:• NAME: L.. PERMIT#: 69 3 la q LOCATION: a 5 S -0 R uct` �' INSPECT ON: S`- c.-id TYPE OF STRUCTURE: 1- etumNr\eu4¢- Y N NIA COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/Headers — Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fi 4 hour Firestopping enetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'/ inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Fo OLD\Building&Codes\inspection Fomts\Framing Firestopping Inspection Report.doc Revised January 7,2008 Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart:/ ( ` am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:/! it-AC) l NAME: C '.co(N e PERMIT #: b 9 LOCATION: 158 INSPECT ON: 6-- I0-/4. TYPE OF STRUCTURE: b. t� Y N N/A ough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction ..... . . ... . Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation / Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent _ Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 uz-r- Framing / Firestopping Inspection R`port Office No. (518)761-8256 Date lns pection : Queensbury Building&Code Enforcement Arrive: ` -4 a rn rt:it,141.a nr-r _,,,,,,,?„„/ 742 Bay Road, Queensbury, NY 12804 Inspector's lnitia NAME: �`�-- PERMIT#: LOCATION: )i ::,re- _ INSPECT ON: TYPE OF STRUCTURE: Y NCOMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs I Headers Bracing/Bridging Joist hangers l �� t. 6,- ®�# Jack Posts/Main Beams Exterior sheeting nailed properly �,�- 12"O.C. l 7�� \ L� Headroom 6 ft. 8 in. Stairwells 36 in. or more --�—� ty Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/a(w) 16 gauge(8) 16D nails each side Draft stopping1,000 sq. ft. floor trusses .Anchor Bolts 6 ft. or`less on center Ice and water shield 24 inches from wall 'Fire-separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:Building&Codes Fornns-0i.i)U uiiding&CodesUnspection FommssFramin g Firestopping inspection Report.doc Revised January 7,2008 FramingFirestopping/ Inspection Report Office No. (518)761-8256 Date Inspection request received: 1 l Queensbury Building&Code Enforcement Arrive: am/pm Depart: \ , a /pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:("i!.'(X) NAME: (vim uv. S•tY PERMIT#: O i -304 LOCATION: 7.—S (LA INSPECT ON: .�. TYPE OF STRUCTURE: `c '',3 raming L ` Y N WA COMMENTS: Ci e Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging 11/47 Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches I Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour / Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 16 inch or 5/8 inch Type X Garage side 5/8 inch Type X Cell%g/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Forms-OLO Building&Codeslnspedion FonnsVraming Firestopping Inspection Repott.doc Revised January,7,2008 Framing / Firestopping Inspection Report ± �- Office No. (518)761-8256 Date Inspection request received: L VI q 1 i ( 2 V Queensbury Building&Code Enforcement Arrive: am/pm Depart:` ' m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:6 ,: AL")� � NAME: C v•-•C- r,..,C -N1 v=--s(( c"—. PERMIT#: 3 LOCATION: g-c �: oVim. fa- �'Z.t 65,e._ kA;� INSPECT ON: 11 (5 /f TYPE OF STRUCTURE: SA, Y A NIA COMMENTS: °� raming Attic Access 22" x 30" minimum IIIIIIIII -?____. - Jack Studs/Headers Bracing/Bridging Joist hangers{���C Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing �— —� � +�'e Headroom 6 ft. 8 in. • Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side 9 ug 1 ;. Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center *We and water shield 24 inches from wall , Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping 11 lir Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (VV) 5.7 sf above/below grade 5.0 sf !rade L:1Building&Codes Forms-OLb1Buiidinq&Codes Inspection Fons*Framing Firestopping Inspection Report.doc Revised January 7,2008 inspection /�e Framing / Firestopping Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart:1 C am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ririg.„-- � PERMIT#:LOCATION: � �,� � INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS: Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Va(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft. floor trusses o ft. or less on center r Ice and water s eld 24 inches from wall • s ' n 1, 2, 3 hour ¶Z' Fire wall 2, 3, 4 hour Firestopping A--- -® Penetration sealed Z44.4..}L, 16 inch insulation in cavity min. Garage Fire Separation House side%Inch or 5/8 inch Type X U�� � Garage side 5/8 inch Type X it Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Buiiding&Codes Forms OLDUBuiiding&CodesUnapection FormssFnmdng Firestopping Inspection Report.doc Revised January 7,2008 gaming / Firestopping Inspection Report 7- Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm rt: am/pm 742 Bay Road, Queensbury, NY 12804 Insp ector's Initials: NAME:___43 l r r' r' PERMIT#: ��f LOCATION: 3/1A0 Pr2 at INSPECT ON: TYPE OF STRUCTURE: Framing Y N Id/A COMMENTS: Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. ' Notches I Holes/Bearing Walls J Metal Strapping for Notches Top Plate 1 Va(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses :r • ' :. 6 ft. or less on center ce and water iekl 24 inches from wall `' se• r- •n 1, 2, 3 hour (:255 Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation v House side 16 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Buiiding&Codes Form-0L0IE3uiiding&CodesUnspection Fonnecn►ming Firestopping Inspection Repot,doc Rem January 7,2008 c ( 7' GC'G Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm 9._part:///I am/pm 742 Bay Road, Cueensbury, NY 12804 Inspector's Initials: ; all c NAME: 6 r-o h-,Q._ PERMIT#: LOCATION: (1 c - Y INSPECT ON: /7) TYPE OF STRUCTURE: Framing ' �`�� COMMENTS: ss 22"x 30" minimum Jack Studs/Headers 2 _ to Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'ox(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (VV) 5.7 sf above/below grade 5.0 sf grade L:1Buiiding&Codes Forms-0LO\uilding&Code linspadbn Fonns*Framing Firestopping Inspection Reportdoc Revised January 7,2008 i 0 ,--(2.e--- Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: 51 1 1"( / U Queensbury Building&Code Enforcement Arrive: am/pm (19epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: r. 0 -3 1/7 q NAME: PERMIT##: LOCATION: '' S';/).-‘ c t. ft d, C INSPECT ON: ''/) 2 /0 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour ,, Reinforcement in Place _ i-L/ f� ]\Footing Dowels or Keyway in place /LJ\ Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:OBuilding&Codes Forms\Buiiding&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 7/ fV/ -f • Foundation Inspection RepOA Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial • NAME: '. PERMIT#: ¢ tFy LOCATION: 25 14. ,`� c INSPECT ON: 2' TYPE OF STRUCTURE: Comments _ Y 1! NlA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement i of the con Mate ' s r this e on site. 1/ Foundat on/Wallpour � �, ' f Reinforcemen in 1' ace ✓ Footing Dowels or Keyway in place Foundation Dampprooflug Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:OBuiiding&Codes Forms\Building&Codes`Inspection Forms\Foundation Inspection Reportdoc Last printed 12/20/2005 9:24:00 AM / -/2- Foundation Inspection Report Office No.(518)761-8256 Date Inspection request r Queensbury Building&Code Enforcement Arrive: ann/pm , ��eparr! am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: 0?` 3 0 LOCATION: 9 5— S yo INSPECT ON: -2/() TYPE OF STRUCTURE: Comments N N/A Footings Gar"., l �! Monolithic Slab / Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wailpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Farms\Building&Codes\Inspectlon Forms`Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Ap.4,Fs • Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: 'am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: 367/ LOCATION: ,-, Q INSPECT ON: /(7 TYPE OF STRUCTURE: -�t�, Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width above footing 6 mil pol for wet areas under slab Y Backfill App val \\.( lamb" nder Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Repo Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Departf J am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: C.A4) NAME: __� � PERMIT#: 0 7 3 C 4/. LOCATION: INSPECT ON: -2 6-to TYPE OF STRUCTURE: Comments Y N N/A Footings Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour N,\..74/7 Reinforce ent in Place 40,9, Fo tmg Dowels or Keyway in place Foundation Dampproofmg \5 L.J.-(5-12_172. — Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 1- Lk4ScAj Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm ( part: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: // NAME: PERMIT#: (4-3g/ LOCATION: _, rt. ' 07-e INSPECT ON: -2/ :/O TYPE OF STRUCTURE: c/ Comments Y N NA Footings Piers o h'c Reinforce�t entSlab in Place The ntractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date In do 0 av est received: Queensbury Building&Code Enforcement Arrive:j' - : r pm\ part: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspe•W Initials: -_ NAME: /���lC`" PERMIT#: jQa LOCATION: � i /,C6� a INSPECT ON: `7 c? TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm r `Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 inspector's Initials: NAME: C- t PERMIT#: CC C1 "L/ LOCATION: INSPECT ON: 7 /o q / C� TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this ( ease on site. Foundation/Wailpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM /— )71® bikr) Foundation Inspection Report /- /Z) Office No.(518)761-8256 Date Ins.ectio s • st received: Queensbury Building&Code Enforcement Arrive:- " ;• ^^ p D am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's In r als: NAME: J _C a PERMIT#: LOCATION: 2 ;2 .f.e INSPECT ON: — r/D TYPE OF STRUCTURE: Comments �®- N /A Footings Monolithic Slab 7"" /e64-4 Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 0 .- 317-1/' ' Recheck Software Version 4.2.2 Compliance Certificate c ..„ 4,06 ,„ ,,. Project Title: JMC Properties -Townhouse II ,,,,o r � � � Energy Code: 2007 New York Energy Conservation v, +�-4 Construction Code Location: Warren County,New York 1, ; 02633° �6- Construction Type: Detached 1 or 2 Family ®F NO Heating Type: Non-Electric Glazing Area Percentage: 14% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: Smoke Ridge Road Joseph A Paone Queensbury,NY Paone Architecture,PC 547 Route 9P Saratoga Springs,NY 12866 518-580-0017 ,ttzra YN:._..�� *. , ` Oa. Y-�3;F�'�" „'��'�2'.t'_t�. `�.d..S�:� `.7 ,. .x_EVRMVtaN .s"i*Itg€,-M z'��`„� ��'`a.`�. ".�M Compliance:2.1%Better Than Code Maximum UA:382 Your UA:374 Gross Cavity Cont. Glazing UA Assembly - Area or R-Value R-Value or Door Perimeter U-Factor Ceiling:Flat Ceiling or Scissor Truss 1627 38.0 0.0 49 Wall:Wood Frame,16"o.c. 1872 21.0 0.0 90 Window A:Vinyl Frame:Double Pane 14 0.460 6 Window A:Vinyl Frame:Double Pane 14 0.460 6 Window A:Vinyl Frame:Double Pane 14 0.460 6 Window B:Vinyl Frame:Double Pane 9 0.460 4 Window C:Vinyl Frame:Double Pane 34 0.460 16 Window C:Vinyl Frame:Double Pane 34 0.460 16 Window C:Vinyl Frame:Double Pane 34 0.460 16 Window D:Vinyl Frame:Double Pane 38 0.460 17 Window E:Vinyl Frame:Double Pane 18 0.460 8 Door-Dl:Vinyl Frame:Double Pane 40 0.460 18 Door-Front:Solid 20 0.350 7 Door-Garage:Solid 20 0.350 7 Basement Wall:Solid Concrete or Masonry 1764 13.0 0.0 102 Wall height:8.3' Depth below grade:7.4' Insulation depth:8.3' Window F:Vinyl Frame:Double Pane 3 0.550 2 Window F:Vinyl Frame:Double Pane 3 0.550 2 . Window F:Vinyl Frame:Double Pane 3 0.550 2 The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowled ,belief,and professional judgment,such plans or specifications Te•" ompliance with this Code. V4t,leve r it e (I- __ 6 `fS Name-Title Signature Date Project Title:JMC Properties-Townhouse II Report date:06/10/09 Data filename:P:\PAProjects\JMC\JMC-Il.rck Page 1 of 5 REScheck Software Version 4.2.2 Inspection Checklist Ceilings: ❑ Ceiling:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall:Wood Frame,16"o.c.,R-21.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall:Solid Concrete or Masonry,8.3'ht I 7.4'bg/8.3'insul,R-13.0 cavity insulation Comments: Windows: ❑ Window A:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window A:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window A:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window B:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window C:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window C:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window C:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window D:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Project Title:JMC Properties-Townhouse II Report date: 06/10/09 Data filename: P:\PAProjects\JMC\JMC-II.rck Page 2 of 5 Comments: ❑ Window E:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?_ Yes No Comments: ❑ Door-D1:Vinyl Frame:Double Pane,U-factor:0.460 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window F:Vinyl Frame:Double Pane,U-factor:0.550 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window F:Vinyl Frame:Double Pane,U-factor:0.550 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑Window F:Vinyl Frame:Double Pane,U-factor:0.550 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door-Front:Solid,U-factor:0.350 Comments: ❑ Door-Garage:Solid,U-factor:0.350 Comments: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: ❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification and Installation: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Ducts in unconditioned spaces or outside the building are insulated to at least R-8. ❑ Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to at least R-6. Duct Construction: ❑ All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or tapes.Tapes and mastics are rated UL 181A or UL 181B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: Project Title:JMC Properties-Townhouse II Report date:06/10/09 Data filename: P:\PAProjects\JMC\JMC-ll.rck Page 3 of 5 © Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: u Separate electric meters exist for each dwelling unit. Fireplaces: • Fireplaces are installed with tight fitting non-combustible fireplace doors. • Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: D Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. • Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: • Circulating hot water pipes are insulated to the levels in Table 1. Heating and Cooling Piping Insulation: • HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Swimming Pools: • All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Project Title:JMC Properties-Townhouse II Report date:06/10/09 Data filename: P:\PAProjects\JMC\JMC-Il.rck Page 4 of 5 rt Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" Temperature(°F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Insulation Thickness in Inches by Pipe Sizes Fluid Temp. Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Project Title:JMC Properties-Townhouse II Report date:06/10/09 Data filename: P:\PAProjects\JMC\JMC-Il.rck Page 5 of 5