Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ventilator
_s. mot, 100 ECM HEAT RECOVERY VENTILATOR y of ENGINEERING DATA LIFEBRERTH THERMALLY CONDUCTIVE,PATENTED DEFROST I ALUMINUM CORE Recirculating damper defrost system. The counter-flow heat recovery core transfers heat between the two airstreams.It is easily removed for cleaning or service. CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance.Insulated to MOTORS AND BLOWERS prevent exterior condensation.Drain connections 2-1/2 in.(12 mm)OD.Balancing ports High efficiency electronic commutate ECM motor,for maximum energy savings.Each are located on door. airstream has one centrifugal blower,with multiple fanspeed operations driven by one double shaft motor. ELECTRONICS The DXPL02 control included with the unit can be wall mounted in a central location of FILTERS the home.3 wire 20 gauge(min.)100 ft length(max.). Washable antimicrobial MERV 6 air filters in exhaust and supply airstreams. MOUNTING, WARRANTY Four threaded inserts at corners of the cabinet designed to accept the"s"hooks and Units carry a lifetime warranty on the HRV core and a 5 year hanging straps supplied with the unit replacement parts warranty. OPTIONAL ACCESSORIES: Weather Hood 9.EArflle E 99- Wireless 20/40/60 99-185 G4 Terminator 99-18699-EAGS Fitting Min Timer 99-187 99-EAG6 99-TM4 99 OET02 ®!' 99-EAG8 99-TMS `! 99-TM6la ' .- LIFEBREATH CONTROL OPTIONS TIMER OPTIONS FEATURES 99-DXPLO2 99-BCO2 99-BCO3 99-BC04 99 DETOl-Lifebreath 20/40/60 Minute Timer Initiates high speed Ventilation for 20.40 or 60 ✓ minutes.3 wire connection. 5 speed fan operation on each mode ✓ ✓ 99-DET02 2 speed fan operation(Low/High) Wireless Lifebreath 20/40/60 Minute Timer Continuous low speed fan operation ✓ Initiates high speed Ventilation for 20.40 or 60 minutes.Wirelessly connects to main control for Humidity control through adjustable Dehumidistat ✓ ✓ ✓ ease of installation.40'approximate range. Excusive to Lifebreath. Large digital LCD screen I 99-RX02-Wireless Lifebreath Repeater LED status indicator lights ✓ ✓ ✓ Extends range of 99-OET02 Wireless Timers.Plugs into 120V power outlet.Wirelessly connects to Continuous Ventilation ✓ ✓ main control and 99-0ET02.Install at halfway ✓ ✓ point between timer and main wall control if timer Continuous Recirculation is out of range. 20 0N/40 OFF ✓ \®, lea'10 ON/50 OFF ✓ " E' 20 0N/40 Recirculation ✓ ✓ ✓ r ' o ias}cis}>a a l. � , 20/40/60 min.High speed override button ✓ 99 DXPL02 99-DET02 Compatible with 99-DET02 Wireless Timer ✓ ✓ ✓ ✓ tag 3 wire connection ✓ ✓ ✓ ✓ LIFE Er 8 Indoor Air Systems 100ECM(9-11-18) www.lifebreath.com 100 ECM ,_ Y li -, HEAT RECOVERY VENTILATOR i i PERFORMANCE(HVI CERTIFIED) LIFEBaiRETITH' 0.1(25) 0.2(50) 0.3(75) 0.4(100) 0.5(125) 0.6(150) ELECTRICAL SPECIFICATIONS IN,W.G.(PA) CFM(Us) CFM(Us) CFM(Us) CFM(Lis) CFM(Us) CFM(Us) VAC @ 6014z 120 Net Supply Airflow 161(76) 143(68) 129(61) 114(54) 97(46) 18(37) Watts/Low Speed 40 Gross Supply Airflow 165(78) 147(69) 131(62) 117(55) 102(48) 81(38) Watts/High Speed 115 Gross Exhaust Airflow 229(108) 215(101) 210(99) 203(96) 184(87) 142(67) Amp Rating 1.75 Sensible Effectiveness(ASE) 180 WEIGHT: @ 64 CFM(30 Us) 32°F(D°C) 18/a 160 71 LBS(32 KG) Sensible Efficiency(SRE) 32°F(0°C) it°le 140 SHIPPING WEIGHT: @ 64 CFM(30 Us) E 120 73 LBS(33 KG) u Sensible Efficiency(SRE) 32°F(0°C) 69°l0 3 WO @ 95 CFM(45 Us) o so NOTE: Sensible Efficiency(SRE) a @ 68 CFM(32 Us) 13°F(25°C) 64% 60 Front clearance of 25 in.(635 mm)is 40 recommended for servicing unit.MI ducts zo use 6 in.(152 mm)round collars.Balancing �S� dampers are located in all air streams. FAN V`N z,00�, A o.l 0.z 0.3 0.4 o1 o.6 " 8 c us HUI 9001 .�'" r Static Pressure(in w.g.) m� CERTIFIED REGISTERED DIMENSIONS FRONT VIEW SIDE VIEW Filter ' 14 3/41n.(375 mm) Recirculating mum _ Defrost !"! ,EmillIMME Damper Removable ,W9p11.111111111N 1 ; lilt Blower Heat II!J R Heat !doter E Stale air to outside Care ■L, co 14i Fresh air from outside Stale air from inside 4,111 iiik fillil '♦ m Fresh air to inside iii 6Roun in.(d152Colla mmrs) I' 33 5/8 in.(854 mm) I • Date: WARRANTY Tag: Contractor: Units carry a lifetime warranty on the HRV core and a S year replacement parts warranty. Project' Qty: Supplier: Engineer: Quote#: All units conform to CSA and UL standards •/ Control: Submitted By: LIr:EEIRERTH.. ®! Indoor Air Systems Timer: Timer City: TOOECM(9-ll-18) www.lifebreath.com Specification Sheet - Packaged Electric Make-Up Air Heater STANDARD EQUIPMENT • Integrated powered inlet damper • Listed for horizontal or vertical installation • WarmFlo digital proportional temperature control • Unique design allows for simplified installation • Variable CFM,auto adjust based on CT input(208/240V models only) • Hi-limits,automatic and manual reset • Included CT detects L0/MED/HI exhaust fan levels(208/240V models only) • Multiple interfacing options to external controls • Full element modulation • Aluminum mesh permanent washable filter • Inlet and supply air temperature sensors • Thermostat end switch connection point • Three CT inputs available for multiple fan applications(208/240V models only) • Includes chain for suspended installations • LCD display: ■ Can be easily wall-hung -Convenient CFM exhaust fan calibration • 20-year finned rod element warranty -Real time estimated CFM • 2-year parts warranty -Desired target temperature • Made in the USA -Incoming and supply temperature TEMPERATURE RISE & CFM CHART- Selecting the best model for your application: 1 Choose your desired temperature rise(this is the difference between the coldest design day temperature and desired duct air temperature). 2 Move across the chart from your desired temperature rise to the CFM required(you may have to select a model with a higher CFM and adjust down to your required CFM at installation). Example: In an application where your coldest day averages 0°F and you require 50°F duct air,choose 50°F temperature rise. If you require 400 CFM you would select the MA10. SINGLE PHASE MODELS 3-PHASE MODELS Model- MA01 MA02 MA05 MA10 MA15 MA20 MA14 MA22 CFM CFM CFM CFM CFM CFM CFM CFM 80°F 39 71 197 395 604 790 553 869 rx 70°F 45 81 225 451 677 903 632 993 g 60°F 53 95 260 526 790 1053 737 1160 F' v 50°F 63 114 316 632 948 1264 885 N/A 5 40°F 79 158 N/A N/A 1185 N/A N/A N/A a' . 30°F 105 168 N/A N/A N/A N/A N/A N/A SPECIFICATIONS Internal Motor Motor CFM Max Fuse/ Duct Shipping Model kW Btu/h Amps CB FLA Phase Voltage Max Static II aiCR Connection Weight EM-MA01-120-1-06* 1 3,410 8.3 li/A 0.5 1/16 1-50/60 120 150 0.03" 15 6" 39 EM-MA02-120-146* 1.6. 5,460 13.3 N/A 0.5 1/16. 1-50/60 120 150 0.03" 20 6" 41 EM-MA05-240-1-08 5 17,070 20.8 N/A 0.4 1/10 1-50/60 240 350 0.40" 30 8" 59 EM-MA10-240-1-10 10 34,150 41.6 N/A 0.8 1/5 1-50/60 240 600 0.40" 60 10" 65 EM-MA15-240-1-14 15 51,220 62.4 60+30 1.7 1/4 1-50/60 240 1050 0.50" 90 14" 117 EM-MA20-240-1-14 20 68,300 83.2 60+60 2.5 1/2 1-50/60 240 1200 0.50" 120 14" 130 EM-MAl4-208-3-14 14.4 49,170 40.0 50 1.7 1/4 3-50/60 208 900 0.50" 50 14" 117 EM-MA22-208-3-14 21.6 73,760 60.0 50+30 2.5 1/2 3-50/60 208 1250 0.50" 80 14" 130 *Variable Speed:Medium and Low input are NOT available on 120V single phase models. °fj1►us ELECTRO Intertek 1 F INDUSTRIES Specifications subject to change without notice, Monticello,Minnesota all rights reserved. 800.92 www.electromn.com EL912 08/22/201 7 Installation Specifications (Reference Installation&Operating Instructions,E1906) This product is designed for zero clearance,but use the following mounting and spacing criteria: 1. Unit can be installed vertically or horizontally. When vertical,inlet must face down. 2. When using CT doughnut,use Class ll low voltage wiring methods to connect CT to Make-Up Air unit. 3. Make mounting provisions for a 1"air space at the top. 4. The sides,any location,can be in direct contact with wood framing materials. 5. No materials shall be in contact with the cabinet housing which has a flame point less than wood,300°F(150°C). 6. Product shall be installed in a conditioned space only. 7. Heating elements are locked out when entering air temperature is>55°F(12.8°C). ' MAKE-UP AIR II `, HOOK-UP .�� �� 1;1 k.‘‘‘.'"•-•-.,,.,....._,,,,,-*.- :P WW H k I ( 0 r----i 0 I ') ' ,, j "B" © /! MALE DUCT = t •o. • i • \ 01.125 X 0.875 t l - - DOUBLE KNOCKOUT f • le - I 0"D„ MALE DUCT MODEL DIM"A" DIM"B" DIM"C" DIM"D" DIM"E" DIM"F" DIM"G" 1kW-2kW 12 5/8" 10 1/2" 29 3/8" 6 21" 20 5/8" 8 3/4" 5kW 14 3/8" 13 1/2" 39 7/8" 8 31 1/2" 31 1/8" 11 3/4" ART-408-00 FF e�EC2RO�eousrR Es rvc. 10kW 14 3!8" 13 1/2" 39 7/8" 10 31 1/2" 31 1/8" 11 3/4" Rev.H 3/24/2015' i ��0 ICE,�o,nw 53az Sheet 1 of 1 14kW-22kW_____ 223/8" 191/2"____465/8"_ __-_14______381/4" 377/8"_ 173/4"___