2009-432 TOWN OF QUEENSBURY
742 Bay Road,Queensbiuy,NY 12804-5902 (518)7b1-8241
Community Development- Building &Codes (518) 761.8236
ER.1'T'IFI .ATE OF OCCUPANCV
Pernut Number: P20090432 Date Issued: Thursday, August 05, 2010
This is to certify that work requested to be done as shown by Permit Number P20090432
has been completed.
Location: 4 HOWARD St
Tax Map Number. 523400-308-008-0002-067-000-0000
Owner. DAVID A. & DIANNE M. HOWARD CONSTRUCT
Applicant: DAVID &DIANE HOWARD
This structure maybe occupied as a:
Garage Attached By Order of Town Board
Single Family Dwelling TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the r 'P
)4�
property owner of the responsibility for compliance with Site Plan, r v
Variance,or other issues and conditions as a result of approvals by the Directorof Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20090432 Application Number. A20090432
Tax Map No: 523400-308-008-0002-067-000-0000
Permission is hereby granted to: DAVID &DIANE HOWARD
For properly located at: SHERMAN Ave
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the QueensburyZoning
Ordinance. Type of Construction Value
Owner Address: JACQUELINE LIAPES
8303 E DEVONSHIRE Garage Attached
SCOTTSDALE,AZ 85251 Single Family Dwelling $70,000.00
Total Value $70,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans &Specifications
2009-432
1487 SQ FT SINGLE FAMILY DWELLING &426 SQ FT GARAGE
$221.04 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,September 22, 2010
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the rw / ee ury� , September 22,2009
SIGNED BY i'' for the Town of Queensbury.
Director of Building&Code Enforcement
-----<-----------------------------,
OFFICE USE ONLY ;
PROJECT NAME: _D.-,d ;2.-. 0a
0 STAFF INITIALS:
BUILDING PERMIT SUBMISSION DATE: ,
CHECKLIST FOR: 10
------------
SINGLE FAMILY DWELLING
1. Building Permit Application Completed? ES NO N /A
_....._..._..._ - ..........__....._..._...................--.....
2 Energy Form or CheckMate Energy Code Compliance
Forms Complete? (2-copies
3
Energy Code Inspector's Report from Checkmate
Program? (2-copies)
4 1 Septic application completely filled out?
(if applicable)
_ ... -- - ... __......- ---- .-... -----------._..._..._................._.._.._............_.....-..:...._._......._.............._......_ ...........__.
5. Electrical Inspection Form complete?
- - :................_.. -- .... ._._.._.
_ ........... - -
6. Two (2) sets of the plans each of the following: YE NO N /A
-- -- -- ......._................-- - ...._..... ...
a. Floor plans (s)?
— ...............---- --- --- -- --- ------- ---... ........................ . _----- - - ........_.......------ ..........._._ -
b. Foundation plan?
C. Cross sections (s)?
_...._____ _..__.____._-.__.__.-...._._...._____.._...................
_....._..._.. ..._..__..._..---___--------....._..-_....__.__..__.....___.__.._.....__.... _._.
d. Elevations?
e. Window and door schedule?
f. Natural Light, Ventilation and Emergency Egress
Requirements?
j g. Plans signed and sealed by registered architect or I
I......... .....1..._engineer? I
Two (2) site plans showing location of the structure to be
7. built, location of well or water lines, location of septic
system or sewer line?
....._........................- --- .................._.....-......._
F
I 8. Setbacks from property lines to new structure?
i
8 ' Setbacks to neighboring wells and septic systems,
including onsite well and septic systems (if applicable)?
...............
9. Driveway Permit?
�= Town of Queensbury • Community Development Office. • 742 Bay Road, Q.ceensbui-y, NY 12804
B 12-LTR 11-05
i
Check Residential Plan Review: One & Two Family Dwellings
Y/N/N
(2)Full sets of plans
Over 1,500 sq. ft.—Stamped
Design Loads On Plans: 90 Wind Floor Loads 40 psf
50 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
Above/Below grade, 5.7 sq. ft.
Grade,5.0 sq. ft.
J 24"(h)x 20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofing/Waterproofing Materials On Plans
Foundation Drainage On Plans, if required
6"Drop in 10' Exterior Grade
Framing Cross SFr Each Roof Line, F topping Every,10'
Ice and Snow shield 24"Ins- xterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
Stairway Headroom 6' 8' All Stairs 36"Width X
Stair Run and Rise
Winder Run and Rise
Spiral Not.Allowed From 2ndStory
Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance F
�L
Hall Width,36"min. _ k t► =t
Handrails More Than Four Risers On Open Sides47
Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas
tarage Fire Separation
Garage Floor Sloped
Attic Access _
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Outside Lowest Sleeping Area,On Every Level&
erconnected
oil Test Results, if required
Septic To Well Or Water Line Separation
All Paperwork Signed
............. ... ........
r
e r
s r
Comrnunity Development Office
T0,1011 OfQueensbury - 742 Bay Road • Quconsbury, New YorJ, -12804 ;
,
r
r ,
f +
'.......................�
BUILDING PERMIT CALCULATION SHEET: / -
1?W c c � � tilt r't�.*t
NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS
ACTUAL LIGHT REQUIRED A,TSQUARE FOOT
AREA OF ROOM IN LIGHT VENTILATION
HABITABLE ROOM SQUARE FEET &%a OF ROAM SQUARE VENTILATION-4% SQUARE OPENING FOR REMARKS
AREA FOOTAGE OF ROOM AREA FOOTAGE EGRESS
QUESTIONS? CALL 761-8266 OR EMAIL
codes{r_aueensbury,net
VISIT OUR WEBSITE FOR MORE INFORMATION
www.auensbunt.net
8 10-LTR 11•24
��- �- a
Community Development Office
742 Bay Road, Queensbury, NY 12804-5902
Electrical Inspectors
THE FOLLOWING ELECTRICAL INSPECTION AGENCIES ARE CERTIFIED BY THE TOWN OF
QUEENSBURY TO PERFORM ELECTRICAL INSPECTIONS:
Name/ Address of Business Inspector Contact Number(s)
Commonwealth Electrical Local: 800-562-9934
Inspection Services Ron Mumblo Ron: 518-798-0905
176 Doe Run Road
Manheim, PA 17545
Middle Department Ray Novak Main Office: 800-873-6432
143 Troy Schenectady Road Local Office: 800-479-4504
Watervliet, NY 12189 518-273-0861
Ray: 518-369-6614
The Inspector, LLC Richard Moon Main Office: 800-487-0535
4755 McConchie Road Douglas R. Hull Local Office: 518-882-6140
Galway, NY 12074 Brian D. Sweet
David J. Irwin
PLEASE NOTE: WE CANNOT RECOMMEND AN INSPECTOR
PLEASE ASK YOUR CONTRACTOR WHO HE PREFERS TO INSPECT HIS WORK.
REVISED 7/22/09
"Home of Natural Beauty... A Good Place to Live "
_....................................................
,e
FICE USE ONLY
, �
TAX NA`P N( . ♦ Mom" PERMIT 0- 47 /
FEES: PERMIT RECREATION ENGINEERING M1 :` `Imp°!
(If applicable) {
PRINCIPAL STRUCTURE— -
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: A j A. A a,�;w,. w--Awa,e1 OWNER: ���,�L�
Co.+9 s��ucf.2n C�:��knyLLC
ADDRESS: Y'TD (,� «� �_����/_ u«2��„y ADDRESS:
PHONE NOS. /�=3 �� /'/ PHONE NOS.
36/-3 z.Y 3 36r—��•y
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: � ,,� ,�/G ��,,�PHONE: '3,r/-32�l�
LOCATION OF PROPERTY: nrAcr Z.,L I&f ��«.�.-��..�s �✓�.� 6 #u=,.-..r-..� S cc1
HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? eES ❑ NO
IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: � �� /y Lo!f
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT Z I o t-
APPLY TO YOUR Z 1 � p d a W cn
PROJECT 0 < C) , O f rY O = _
w uu- u_ � = IQ— 0 = Z
F- o j Z_
Z Q Q :- � N � Ou- 0 ~ rlSatS
_75 f' 'r ems
SINGLE FAMILY ✓ rr
�uif 6-fe-O.
TWO-FAMILY i
Y 3?-
MULTI-FAMILY
(NO. of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL- j
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED L
GARAGE(1,23)
OTHER
IF COMMERCIAL OR INDUSTRIAL- NAME OF BUSINESS: f
ESTIMATED CONSTRUCTION COST: �0. '060 FUEL TYPE: �� a-S
B 3-LGL 11-05
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ,
ARE THERE EASEMENTS ON PROPERTY? b_/0
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read=re e.
Signed
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
o
, ,
This application / proposed action described ;
Permission is hereby granted to the above pp p p ,
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Application: ;
10
;
BUILDIN ODES A OVAL ZONING APPROVAL
,
DAT DATE
'..................................................... %........-------------
QUESTIONS? CALL 761-8256 OR EMAIL
codes0aueensbury.net
Office Use Only
OFFICE USE ONLY
TAX MAP NO. PERMIT NO. D '�7r` ERMIT FEE
APPROVALS: ZONING TOWN CLERK
I ; I
APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT:
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID
PERMIT. /
OWNER: 1 k rJC �}�IJi' nn[ rj'! 1�C7�E•r•�C� INSTALLER: gelf'o.o-A i Jxee AeA4,fsT-,;;Ir
fit,,��r.co�Il�a► Ce,fn e�/ L L CI J
ADDRESS: q 4�-'? 0pQ ���-'J�ADDRESS:
d/Y/4"
PHONE NOS. '� c�Z PHONE NOS.
36l 32Y3 ---
LOCATION OF INSTALLATION:
RESIDENCE INFORMATION:
NO.OF
YEAR BUILT X COMPUTATION= = TOTAL DAILY FLOW GARBAGE GRINDER
BEDROOMS _ —
1980 or older X 150 gallon per bedroom = INSTALLED?
1981 -1991 X 130 gallon per bedroom = SPA OR HOT TUB
1992-present X 110 gallon per bedroom = INSTALLED? �_
PARCEL INFORMATION:
✓ TOPOGRAPHY: Flat rolling Steep slope %Slope
✓ SOIL NATURE: Sand V Loam Clay Other
✓ GROUNDWATER: At what depth?
✓ BEDROCK/IMPERVIOUS MATERIAL: At what depth?
✓ DOMESTIC WATER SUPLY: Municipal—z"Well (If well: Water supply from any septic
system absorption is ft.)
✓ PERCOLATION TEST: Rate is minutes per inch [MPI]
(Test to be completed by a licensed professional engineer or architect.)
PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by
a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision).
TANK SIZE: ��( Q_GALLON (MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for
each garbage grinder, spa or whirlpool tub.
SYSTEM TYPE:
❑ ABSORPTION FIELD (WITH NO. 2 STONE) Total length ft. Each trench X
❑ SEEPAGE PIT(S) (WITH NO. 3 STONE) How many? Size?
ALTERNATIVE SYSTEM Bed or other type?
❑ HOLDING TANK SYSTEM Total required capacity? 2 , LG�S e4
Tank size? Number of tanks?
NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN
APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED.
For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any
permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or
failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void.
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection requ ed:
� 0�3
Queensbury Building&Code Enforcement Arrive:; p epart: - ' pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi
NAME: RMIT#: �
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
CommgnM
Y zN N
Footings
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Damppruofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Buiiding&Codes Forms\Building&Codes\lnspeCtion Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection ort
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: /'i
NAME: PERMIT#: / -�32
.#100,V%^J%,LOCATION: ad
INSPECT ON:
TYPE OF STRUCTURE:
Comment_
Y N N/A
Footings
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
\�
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Bullding&Codes Fors\Building&Codes\Inspecdon Fors\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 inspector's Initials:
NAME: #ooanol Y PERMIT#: 7-4/ Z,
LOCATION: INSPECT ON:
TYPE OF STRUC
Conlmenb
Y N NA
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
Aimhas above footing
6 RAfor wet areas under slab
Backfdl App val
der Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 8.
L:\Buliding&Codes Forms\Building&Codes\lnspec Hon Fors\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Framing / Firestopping Inspection Report Z- r
Office No. (518)761-8256 Date Inspection
Queensbury Building &Code Enforcement Arrive:'" a pm part: a pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials.
r
NAME: �`�-�' r PERMIT# l �/3
LOCATION: U ct a ti4t2 0 v INSPECT ON:
TYPE OF STRUCTURE:
Y N N A COMMENTS:
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing I Bridging
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom a ft. 8 in.
Notches/Holes I Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D naAs each side
Draft stopping 1,000 sq. fL floor trusses
Anchor Botts 6 ft. or less on center
-ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cav min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-OI.DiBuiiding&CodesUnspedion Forna'Fron inn Fffedopft Inspection ReporLdoc Revised January 7,2006
Septic Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/p_M Depart: 4D 1 am/pm
742 Bay Rd., Queens ry, NY 1 Inspector's Initials: 6 r
NAME: 2804'/ PERMIT NO.:
LOCATION: INSPECT ON:
RECHECK:
Comments and/or diagram
Soil Type: Loam/ Clay
-Typeof Water: unici Well Water
Waterline separation distance ft.
Well separation distance ft.
Other wells: ft.
Well Casing Length 50' + / - Y N-N/A
Absorption Field:Total length ft.
Length of each trench ft.
Depth of trenches
Size of Stone-
Seepage Pits: Number
Size:
Stone Size:
Piping Size T
Building to tank
Tank to Distribution Box
Distribution Box to Field Pit
0 nin Sealed: N
End Ca N
Inlet/Outlet Pipes &Baffles Y 7 N
Location Separations
Foundation to tank ` ft.
Foundation to absorption
Separation of Pits ft.
Conforms as per Plot Plan V.Y
Engineer Report and As-Built Y N
Location of System on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
'n Use to
Approved
Partial Approved and needs to be re-inspected, please call the Building &Codes Office
Disapproved
Last revised 06/18/07 L:\Building&Codes Forms-OLD\Building&Codes\Inspection Forms\Septic Inspection Report.doc
P - prq
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: d 37 U
Queensbury Building &Code Enforcement Arrive. am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:6-1�
NAME: 3�
PERMIT :
LOCATION: INSPECT ON: ® �
TYPE OF STRUCTURE:
Y N N/A
Rou h Plumbi /Nail Plates
PlumbingNeint/Vents in Place
' ' ch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation ReporLrevised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 inspector's Initials:
NAME: PERMIT#: — �Z
LOCATION: INSPECT ON: `7-0
TYPE OF STRUCTURE:
Y N WA Framing COMMENTS:
Attic A s 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging V
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in. /
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Wails
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft floor trusses
Anchor Bolts 6 ft. or less on center
ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
3, 4 hour
trestoppirtg
Pe sealed
Inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Fortes-OLOSUNding&CodWinsWiion Fom*\FmnhV Fkedopp ft Inspection Repott.doc Revised January 7,20CM
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm De ` am/pm
742 Bay Road, Queensbury, NY 12804 inspector's Initials: "I X_ I
NAME: PERMIT#: C ,.4
Z
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N WA COMMENTS:
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 h w 16 gauge $ 16D nags each we
Draft stopping 1,000 sq. ft floor trusses
Anchor Bolts 6 ft. or less on center
lee and water shield 24 inches from wail
Fire separation 1, 2, 3 hour
6PW�w-a3,4 hourtration sealed
16 inch insulation in cav min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. W
5.7 sf above/below grade
5.0 sf grade
LABuiiding&Codes Forms-OLMBuilding&CodosV ropectfon FomisTraming Firestopping Inspeckion ReporLdoc Revised January 7,2WS
/0 %s .
Rough Plumbing / Insulation Inspeetion Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depa am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: '� PERMIT #:
LOCATION: 4n, c INSPECT ON:
TYPE OF STRUCTURE:
f—6�2-
Y N N/A
Rough Plumbing/ Nail Plates
Plumbing Vent/Vents in Place
1 %inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
-le
50 P. .1 fi 15 minutes
insulation/ esidential Check/Commercial Check
T ek imilar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Seal No insulation
Duct i Hot Water Pipin subati
if required unheated aces
Combustion Air Su for Furnace
Duct work sealed properly/No duct tape
COMMENTS: 'V'�� V'��
Q VA
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, 7,2008
Rough Plumbing / Insulation Inspection SIkeport
Office No. (518) 761-8256 Date Inspection request received: ld 3 o
Queensbury Building &Code Enforcement Arrive: �am/pm art: t am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT : cP'n 7
LOCATION: INSPECT ON: i
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing J Nail Plates
Plumbing Vent/Vents in Place
1 %inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
r 15 minutes
Insu n/ esidential Check/Commercial Check
imilar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properiy/No duct tape
COMMENTS: F-L-
Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7.2008
. 16 " / z11,1-
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/pm rt: a�,�M/Prn
Date inspection request received: �16r
Inspector's Initials:
NAME: U PERMIT#: 01
LOCATION: 1 6 l-� S; DATE:
TYPE OF STRUCTURE:
Comments:
A
,V Building Number Address visible from road L G G V- O�x
ChimneyHeight/"B'Vent/Direct Vent Location
Fresh Air Intake y°
3 inch PlumbingVent through roof minimum 6 inches r_0 / .2 �'1'`
Roof Complete/Exterior Finish Complete
Platform at all exterior doors 9 / b�
Handrail 4 or more risers Y
Guards at stairs decks atios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more ol V,
Handrail Termination at Newell Post or Wall
tnterior/Exterior Railings 34 inches to 38 inches h ,
Deck Bracing/Handica Ramp Compliant Grade away from foundation 6 inches with 10 feet VA S S V" ►_T
6 inch dearance to sill plate
Gas Valve shut-off e /regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen waterfi ht
Sa lain /Winglaw in stairwells safety al4zing
Interior Smoke Dqt6dors/Carbon Mg&xid elect
Every level: Eve fled
Outside every bedroom ea.
Inter Connected: Batts badku :
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch acc:ess, 1 N.ft.-150 sq.ft.vents tt �
Bathroom Fans if no window crime�- 4
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emerawcy egress below grade t d"
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumac e/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110 '�
Enclosed Stairs Sheetnrock Underside minimum'A"Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Gara a fireproofing/%hour fire door/door closer
Duct work Sealed prop2rly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan ,
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bon din
As Built Septic System/Sewer Dept. Ins ion Sticker
She Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O 1 Temporary/Permanent
L:\Buildtng&Codes Forms\Building&Codes\Inspection FomhsWesidential Final Inspection Fomh_revised_100405.doc;Revised
January 7,2008;Revised 6/2601
k"P
Queensbury Building & Code Enforcement - Residential �41ction
1% ice No. (518) 761-8256 Arrive: — am/pm Depart: ,am/pm
Date inspection request received: inspector's Initials: _
NAME: ►� PERMIT#: �n
LOCATION: DATE:
TYPE OF STRUCTUR V x
Comments•
N A
4' Building Number Address visible from road r t7
Chimney Nei ht/"B'Vent/Direct Vent Location r
Fresh Air Intake cS e-
3 inch Plumbing Vent through roof minimum 6 inches �^
Roof Complete/Exterior Finish Complete
C�z i rr
Platform at all exterior doors
Handrail 4 or more risersGuards at at stairs decks tios more than 30 inches above arade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
interlorlExterior Railings 34 inches to 38 inches
Deck Bract /Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed 1 regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen waterti ht
Sa glazing t Win in stairwells safeclodin `" z
Interior Smoke De ors/Carbon lyonoxid Detectors
Every level: E ry Bedroom V
Outside every bedr000rer.: --3z- -- ./ I 0��
Inter Connected: Bafte backup:
Attic access 30 inches x 22 inches x 30 inches(Wight)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 .ft.-150 s .ft.vents
1 0-
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation I Insulation Cert'ffication
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater opprating
Law water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock underside minimum%"G sum w
Basement stairs closed rise'4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly-
Gas Logo in Sealed or Glass Enclosure .10
Final Electrical01
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
0.
Flex Gas Pipe Bonding
As Built Sepfic System/Sewer Dept. Ins on Sticker
Site Plan /VadRq22_Lequired
Flood Plain Certification,if required
Okay to issue C I C or C 10 1 Temporary/Permanent
LABuilding&Codes Forms\Building&CodeMinspection Forms,\Residential Final inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08
Final Survey Inspection
Dept. of Community Development
Town of Queensbury
742 Bay Road
Queensbury,NY 12804
Date received:
NAME: �m
LOCATION: �`-s►'�-�
PERMIT#: n9 '
A:3
Final Survey Plot Plan
Approved Denied
The attached final
survey has been
received by the
Dept.of L/
Community
Development.
Upon review the
survey has been:
CralgArown, Zoning Administrator
Notes:
L:1SueHemingway\Building.Codes.Inspection.FORMS\Final Survey
Zoning Administrator.doc
r, „ ,>. %y .. zRj ° fir+; c. ' •t 4:N-e"1 ,.. p'l
�M1,� +45+iZµlyLhn N 5 + ftl,. to 'I t�,f :Myj ,Sw' 'i"
'11�ur ti `� `� y ``' . +•�7 4 e k� y7 y j rL t�'a `4tiLJ� �ti\s • J'1✓ - '•�•
+s� yr z,�:y:'. � • s W
.,:�•d it +1.� 3yi A t, �,2, i r.,�v.' v i� .. • ' 3 R� °
.-r .rt. r }J q;;;3't= Y_.g�t, a t,, M1_ iF� ,,M1 *fn r;r a' • ='r-:be-r`ti+Yt_'6 yS• '4id"z• iy. Q
•,r, . �vs.`c � �'�+'r�a�'. .x 9. a,�¢. .3 a.'- ;,�'' i. - c a±tis ,C"3' ' .. tt"E1'r S 1..U'? w..rrt„c�:t'�.��... . -•' •••" �`t.�t �t r
.1;: k. �'k"� a c� M .rxt:<' ,,.i • c '_2„ •.4z.r r• ,4tt ll] = 8 F t1r O O
.3 3 e- 1 •s v tr, F
i } " 'y •./4 Y)u5m3 3 >,� . { ;�;: # • ti4 Mj N Ll O Z W F=p U
?c.,�. .t =•t? "`''•G'' „� ; +y;-w i* 1'1'. r�`'' > �,`, z,+3z::b>r'+' l;k ►'y�p� �•:�� #•k.*,-
r,, t • n M , i s c r.x t ..x ,.,_ �• tR _� O O O O m Z p O O
r.
? F» LT i 7 : •; _ '� � , ' H' -`, wt'. _ n �`' o o a r F a b Q
z,.n, ti "�? i'� ,4 v, >' ",a.7',' .K R< .:. �Cz ,�. Y� `• . `i zr t� (.9 Q WO`C p O N 7�= 2 =W (n r�
}a O p; - O rc� a!n W O FO-
. Q Q Y vi
, Ar', ka t ?L' u • � .}c: W a, _ I'F-U J 6~ w Q O J F W 0
• ` e i ;. kr743r ^, " �3 .'ILA;'ee t `�' , s;' a y U W N W.
pp�,j•O y
' .yn� ^x ° tip, ;r.;•�" _ V 3.' F Yt '�?, .'' tiM1 ak%a/ iu.,dM:2- ,t-:� )�•,�". �7� .iir, z 8 V m- F— a J Z V1 �+-p a ,W p
� w 4 .' i' �► w", ` M1 �R' a: .'; °' ¢ F w cnb ° °WQw 0o p7d' zzd' Z
(y O o w O a.0 oN � �v3 z�izU Q
N Q ~�UO Qw FOV' �W woiER �� sq '
l �' ,1 • }' O o 0 W F a 9 rw
�.a,, . • yM � ' 3R z , R • • 'r ,,C: WZ Z Z ���p L)� �� �U
.. • w Z � ]. X vj
O .'��V�� QU ate' �p �� Zp
1 { r d •,� R M •3 r 3 R _ 3 3 �" Z Z Z Z w V
N Y
Q p ��woi o WZo
W �7.
:;. ►, . ;' �C� 'aC �j o Q Q I. 0 0 5 O c L,,. �,.w o
•. ...,,... f'. •.,1x : i�. F S' :3 Rr 3 t V �� m p�Q �W F m WF (n�q OFWN � O .6
•�O ro F �1?'Zc. a !i§. 'o-' L. ey{ .t • � '+ h,_ ,` t ss ..fit zs • 5� v O •+ fn _ J O ( m
.,1;2' Y T, .N'yt• ,s, L ,,,, ,R� b ? -` •+,P t '.tia,�, :,r "fug .�. r't •1".r.•4..`:k Z F a a Q b o o
a ., Ob 3 OZ a� 3 tz E O V w
• • �Z� y„ t ti" t x :iix ,M eh ' .,.F• a ��2'• 3 �l�R .y ' •r , ig )R rR' � _• t3�i'• (" •— 1— C� Q O V F— O R
•� �'I" ':z� � *v: ' :f ; ,� '� °tip` � � •.� "rx �� y �..,� ..�.'ms•�� � W Q Q
r s . , to w} n. Z N sJ 0
se;�.�.�."1@[ •�-Mr<.,1Y ° re �+.?:1 ��3;fiT�i?� .ef' .,s wi. :e •%s`' n'i� 'y F' f-r•.� ). '+'1f�:, :w u�h �h�� ;';aa""• r i�• W Q � �(j��y p — Z
t4 • p 3 J F—F�h•' Q Q O "O 8 O O p W ~I p� C�
,:fir 4{■+ - y Q �i ° R U Q O C�F,�. Z ,l j Z C'1 �'0�'
i lh` 3Yf ��i� iSL,' l i�:e' `�* 'y�.•,' `4" �)_; l..�` s".,*1 J •'.'3 t � •rl•.. W '• Q b /.1". I1. O ' �• r.l
Me
: N C> Z V a U Q V Z G `F�
• 6 F Z O�'NV �. N W Q QCL
! ,t yr. q T.._,..;Y �;r �`„�K 4a 'C.p,e'.: .y 1.�•{'� Y -l >~ !�`i� ti :.,'�`.•4 3 3 tie. w..:. � `w, �_ Z -
-it��.it�n L"'t!, t�' �vtM �� M - M' � L ,•. 'l v+�•''"tt�, � i
Y. ,•Q `Ljte•, T, J .i.t} It 6 •'i d !' /. r, q bcsz
? '. .,. r tip:•..s'. W wQ �y Q mQ ZQ p0 ZWw *O 5W0•�-1wQ
S q
�'' �`. - fit, <. ���° •..� � •2 W �Op � m Z �QW N Om08 o�U Om0 JmU
j n.. �
.�,�;.•„y`,�M1
'+L. ,•z t,M "''ryF-', ,R ;'� z� '�" t.,�� ) R�.: �).MY 4 t= 3 ' r'�+� ':� �,: ^���<��.•;,'"FEv.'*�" * � •� .— �1 .— N M sf' to t0 f�
8 M1 t :.'',,`. .'. �J r 1 M1 V � � �f"x.,g,1 'tn � Pam• � •,`
.vim:E:�x�C�„'� , LF YJ'R `.� R ) }'( I`w'�� - .� •�Y.�
'S. >��{{ aR.�]`; ,Y.�„6 ftr .x L .,ur-,n'...,uM'ac.kr+ � ���i =• _ Km�•I' I..�IIf+`` .- A�'
�' I(,' ) �`Y �M1u 3,� � f�i, • i., "f� tI`3 � •• � •�• DIY '^ �1 V
I ,K2� .,-'cr' �3 r r M' ' L .g- %M'`;r ,nEc C,RiC �- •".� Y'�' , 'C\I't", i�o ,,:i� ` \. \\\\\ � O
�`,o. •{�'e8� �S;, L e •tl.,a. .� '� � M1 .�� Y�-•�,.� � ..� ,.xs', �. a. u., :".`�':_. I �' �\\ \ `'\ 1(� `lxA■
'4cM s 1 ,dM "'� �y _ ro- M� ,R: '���:. ).2 ,r A3'c '�%ir ti �F[¢• u��� M, e�.'e.. 1.� �\ '\�`� ` � O 77
'G...l. Y'{9 „� , �` •'!.�C '`• a, ,1. 'ly -'�R ".,1;�M1- � `!'>. yY'�`2' � � � �..1 \\\\\
�.ti � .'Y l'K f 41 '� � I ,R •.\ i' ` •R'A'r,�CM 'n•L'"'. "'.R�: � •� \ y!� � �•'
-���.1•` 3 L: � t,,,.,, �',\ �rK� =+;�. .)._ e"�' � � �K,ro� � y ='.;r'�'�i,'w`K 3. � .� / 'V '���\\\�� V J� O ►.�
x•:.1 '� ) r j � t I 'r ''+'SCR � �2 �S"' '` ) c{ r�"�� Y�M � � � S
y
t. � {c. A i3�_:: ;w., ...!�..;'.•..I��y *�r.; ,I R'. ',.`".. '4'4j 4. ,.� - � ,'�':::.t�5.,:, •G' e�y ;� � 2. � •�
411
Li
00
N \`\ \` \,\
p p
ZZ �I w
q Bo� "w 0 0
wwu� -
( Yv in o 'C
�j 8agn-a3 �� awe 11 6 $
000Fo�Q oflo .;9'Zi►� �'
�11I�Q
�
�a� x0con: L�
000
�g
cr&y.#OH 3
_Myp r ,
Moo � U II
Myc Myo ^� V
Myo
Myo r�4t
M yp Myo V
60OZ tOLLYI DYN .Cg
� o
C'
� � o
t
Sep 09 09 11:28a Ron Rucinski 518-584-5012 p.1
07
RUCINSKI HALL ARCHITECTURE
Ronald Richard Rucinski
Ethan Peter Hall
627 Maple Avenue �J-
Saratoga Springs NY 12866
Voice 518 580 1905 `s
Fax 518 584 5012 '
Email ronrr@nyeap.rr.com
ephall@nycap.rr.com
Fax - Sheet 1 of 1
To: David Hatin —Code Enforcement Officer—Town of Queensbury
From: Ethan Hall
Date: 9 September, 2009
Re: David Howard—Sherman Ave— New Residence perc test
At the above referenced project location I performed a percolation test for sewage disposal system
design on 4 September 2009. The results of the percolation test and the sewage disposal design
for the proposed residence are included herewith. If there are any questions please give me a call
to discuss.
Soil type—well drained sand with topsoil and some loam.
Percolation test depth at 26" —minor root system to 14" below grade.
Percolation test results:
18t test 0 min. 56 sec.
2nd test 1 min. 02 sec.
3'd test 1 min. 08 sec.
0 test 1 min. 13 sec.
5th test 1 min. 15 sec.
61h test 1 min. 23 sec.
71h test 1 min. 24 sec.
Stabilized percolation rate of 1 to 5 min.
New 3 bedroom single family residence with water saving fixtures at 110 gpd = 330 gpd total
sewage produced. Application rate of 1.2 gpd/sf for 1 to 5 min. percolation rate. 330 gpd divided
by 1.2 gpd/sf= 275 sf of field required. Provide 4 laterals at 35' due to space available on lot = 280
sf of the field. 1,000 gal septic tank min. required. Separation between foundation and septic tank
to be 10'-0" min. Separation between foundation and tile field to be 20'-0" min.
If there are any questions pertaining to this item please give me a call to discuss. As required an
as-built drawing of the sewage disposal system will be provided prior to the issuance of a certificate
of occupancy.
Y:\Howard Apartments\Sherman Ave ResidenceTax 9 Sept 2009.doc 1
/Y ` b179
3v1-)-
RUCINSKI HALL ARCHITECTURE
Ronald Richard Rucinski
Ethan Peter Hall
G�
627 Maple Avenue
Saratoga Springs NY 12866
Voice 518 580 1905
Fax 518 584 5012
Email ronrr@nycap.rr.com
ephall@nycap.rr.com
Transmittal
I
To: John O'Brien—Town of Queensbury— Building Department
From: Ethan Hall
Date: 18 September, 2009
Re: David Howard —Sherman Avenue Spec house
In response to our telephone conversation of 17 September we offer the following responses with
the revised drawings attached as follows;
• Drawing A-1 — Energy Data table has been modified to correspond with the Res-Check
originally provided. Additionally please note the floor framing has been revised to reflect
changes discussed with the builder.
• Drawing A-2 — Floor framing revised to reflect changes discussed with the builder. Access
panel to truss space above garage through walk-in closet in master bedroom.
• Drawing A-4 — Foundation insulation indicated on building section. Also a garage section
has been added to this drawing as requested.
I believe this addresses all the items we discussed. If there are any additional questions please call
to discuss.
Y:\Howard Apardnents\Sherman Ave ResidenceUransmittal 18 Sept 2009.doc 1
Zon�r�g Board of Appeals
4 Final Approved Plans
File No. � " 4.
_. ZBA Meeting Date:
� -
Applrcant Name.
yl LV.
Location.
Corrid�
Applicant(s� 1 David W. Howard _ Area Variance No.: 46-2009
Owner(s): Jacqueline Liapes_ - SEQRA Type: II
- — -
Agent(s)• Kasandra L. Issacson lot size: j-0_19 acres
Location: corner of Howard St. and Sherman Ave. ,- Zoning MDR
Tax Id No.: 308.08-2-67 Section: 179-3-_040
Cross Ref.: None _Warren County Planning:n/a
Public Hearing_ 1 August 19, 2009 - — - - �—Adirondack Park Agency:I n/a _
Project Description: Applicant proposes construction of a 2,280 sq. ft. single-family dwelling with a 418 sq. ft. attache(
__garage._Applicant requests relief from the front and rear setback requirements of the MDR zone.
Craig Brown, Zoning Administrator
3 sets: ZBA File / Bruce Frank / g. Permit
Code Compliance Officer
Zoning Board of Appeals - Record of Resolution
Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8238
FOLLOW- UP RESOLUTION
August 20, 2009
TO: David W. Howard PROJECT FOR: David W. Howard
470 West Mountain Road corner of Howard St.
Queensbury, NY 12804 and Sherman Ave.
Your application, after review and consideration by the Zoning Board of Appeals, was:
_X_ Approved. The variance approval is valid for one (1) year from the date of approval.
You may request an extension of approval before the one (1) year time
frame has expired. See section 179-14-090
A copy of the resolution is attached.
Additional requirements and review for this project shall include:
Zoning Office
_X_ See approval conditions in resolution.
_X_ Submit three (3) copies of the approved plan depicting all changes and
conditions of the approval as adopted by the Zoning Board of Appeals. Please
bring the plans to the Zoning Office for the Zoning Administrator's signature. These
plans will need to be reviewed and approved prior to issuance of a building
permit.
_X_ Please contact Bruce Frank, Code Compliance Officer at 761-8226 within 30 days
of the ZBA approval date for a site inspection before any work is started.
Page 1 of 2
Approval of the application means that the applicant can now apply for a Building Permit unless
your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review
by the Queensbury Planning Board.)
r
Zoning Board of Appeals - Record of Resolution
Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8238
Continued Follow-Up Resoluticn Letter
ZBA Meeting Date: Wednesday, August 19, 2009
Area Variance No. 46-2009, David W. Howard
Building Department
_X_ Application for a Building Permit
Application for a Certificate of Occupancy
Application for necessary Sign permits, if applicable
No further discretionary review is necessary at this time
This office will be performing necessary inspections related to Site issues, not Building Code
issues, throughout the duration of the project. Completion of and continued compliance with
all details and conditions of approval are required in order to receive and maintain approvals.
Since r y,
l IX
Craig Brown
Zoning Administrator
CB/sh
Encl.
cc: Kasandra L. Isaacson
Page 2 of 2
Approval of the application means that the applicant can now apply for a Building Permit unless
your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review
by the Queensbury Planning Board.)
1
Zoning Board of Appeals - Record of Resolution
Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8238
James Underwood, Chairman Roy Urrico, Secretary
TO: David W. Howard PROJECT FOR: David W. Howard
470 West Mountain Road corner of Howard St.
Queensbury, NY 12804 and Sherman Ave.
The Queensbury Zoning Board of Appeals has reviewed the following request at the below
stated meeting and has resolved the following:
Area Variance No. 46-2009 David W. Howard
Meeting Date: Wednesday, August 19, 2009
Approved X
MOTION TO APPROVE AREA VARIANCE NO. 46-2009 DAVID W. HOWARD, Introduced by George
Drellos who moved for its adoption, seconded by Brian Clements:
Corner of Howard St. and Sherman Ave. The applicant proposes construction of a 2,280 square
foot single family dwelling with a 418 square foot attached garage on a 0.16 acre lot. Relief
required. Applicant requests 10.2 feet of front setback relief, 20 feet of rear setback relief per
Section 179-3-040 for the MDR district. In making our determination, whether an undesirable
change will be produced in the character of the neighborhood or a detriment to nearby
properties will be created by granting of this Area Variance. Minor impacts to the
neighborhood are anticipated. If anything, it'll be an improvement to the area. Whether the
benefit sought by the applicant can be achieved by some method feasible for the applicant to
pursue other than an Area Variance. Due to the lot size constraints, there is no other method
that can be achieved. He's made the house to fit the lot, and being only 20 feet wide, that's
the best we can see here. Whether the requested Area Variance is substantial. The request is
moderate at best, but with the size of the lot, it is needed. Whether the proposed variance will
have an adverse effect or impact on the physical or environmental conditions in the
Page 1 of 2
Approval of the application means that the applicant can now apply for a Building Permit unless
your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review
by the Queensbury Planning Board.)
i
Zoning Board of Appeals - Record of Resolution
Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8238
Continued resolution
ZBA Meeting Date: Wednesday, August 19, 2009
Area Variance No. 46-2009, David Howard
neighborhood or district. No impacts are expected. Whether the alleged difficulty was self-
created. I don't think so. I think it's not, being the size of the lot, I think they've done a good job
in making the house fit the lot, so I don't see that it was self-created. So I make a motion that
we approve Area Variance No. 46-2009.
Duly adopted this 19th day of August, 2009, by the following vote:
AYES: Mr. Clements, Mr. Garrand, Mrs. Hunt, Mr. Urrico, Mrs. Jenkin, Mr. Drellos,
Mr. Underwood
NOES: NONE
Sincerely,
James Underwood, Chairman
Queensbury Zoning Board of Appeals
JU/sh
cc: Kasandra L. Isaacson
The variance approval is valid for one (1) year from the date of approval. You may request an
extension of approval before the one (1) year time frame has expired. See section 179-14-090
Final, approved plans in compliance with this variance must be submitted to the Community
Development Department before any further review by the Zoning Administrator or Building &
Codes personnel. Subsequent issuance of further permits, including building permits are
dependent on receipt.
Page 2 of 2
Approval of the application means that the applicant can now apply for a Building Permit unless
your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review
by the Queensbury Planning Board.)
Area Variance Revised June 2009
Site Development Data
Area/Type Pro :used
p �'otaEs�Ad �-
.Tf
A. Building footprint ctitl�tir,s j
B. Detached Garage
C. Accessory Structure(s)
D. Paved, gravel or other hard surfaced area
E. Porches/Decks Lf
F. Other
G. Total Non-Permlrable [Add A-F]
PH. Parcel Area [43,560 sq. ft. /acre]ntage of Impermeable Area of Site [I=G/H]
Setback Requirements
Area 04
X(Sfing
Front [1] =
Front [2]
Sho 3 0
reline
Side Yard [1]
Side Yard [2]
Rear Yard [1] (`
Rear Yard [2) "
Travel Corridor
Height [max]
Permeability
No. of parking spaces
Town of Queensbury•Zoning Office-742 Bay Road•Queensbury, NY 12804-518-761-8238
Area Variance Revised June 2009
Additional Project Information
1. Will the proposal require a Septic Variance from the Town Board of Health? /I/D
2. If the parcel has previous approvals, list application number(s): 4A}
3. Does this project require coverage under the NYS DEC Stormwater Pollution Prevention Program?
/ND
4. Estimated project duration: Start Date End Date
5. Estimated total cost of project: y e d/ . QC/
6. Total area of land disturbance for project: I-LI
Floor Area Ratio Worksheet
FLOOR AREA RATIO (FAR) -- The relationship of building size to lot size, derived by dividing the total building
fl r area by the lot size in square feet, yielding a percentage.
Zon��g trfCtw � -; v ¢
P-
Naterfront Resi ntial WR 0.22
commercial Moderate CM 0,
.'ommercial Intensive Cl 0.3
The combined area of all square foota as measure fro xterior walls of all structures on the property, including all
floors of the structures, garages, base m is and atti with more than five (5) feet of ceiling height and covered
porches. Building square footage does not ' clude• pen deck, docks and that portion of covered docks extending
over water and one storage shed of one hun d twenty (120) square feet or less. Any additional sheds will be
included. (See"FLOOR AREA RATIO").
Commercial or industrial: the total area i square feet a easured from the exterior of the outside walls of a building
or structure, and when applicable, th um total of all floor eas of the principal and accessory buildings or structures
on the project site.
ircel Area ft.
;isting Floor AreX sq. see above definition]
oposed A4ditional Floor Area sq. ft.
epos ' Total Floor Area sq. ft.
t Allowable Floor Area (Area x [see above table
Town of Queensbury•Zoning Office• 742 Bay Road•Queensbury, NY 12804.518-761-8238 3
CREScheck Software Version 4.2.2
NJ( Compliance Certificate
Project Title: New Single Family Residence -4;.Ipy
Energy Code: 2007 New York Energy Conservation d�
Construction Code
Location: Warren County,New York
Construction Type: Detached 1 or 2 Family
Heating Type: Non-Electric
Glazing Area Percentage: 13%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Contractor:
Sherman Ave David Howard Ethan P.Hall
Queensbury,NY 12804 West Mountain Road Rucinski Hall Architecture
Queensbury,NY 12804 627 Maple Ave
Saratoga Springs,NY 12866
518-580-1905
ephali@nycap.rr.com
Compliance:Passes
Compliance:25.1%Better Than Code Maximum UA:394 Your UA:295
Gross Cavity Cont. Glazing UA
Assembly Area or R-Value R-Value or D.•
Perimeter U-Factor
Ceiling 1:Raised or Energy Truss 760 38.0 0.0 19
Wall 1:Wood Frame,16"o.c. 928 21.0 0.0 47
Window 1:Vinyl Frame:bouble Pane with Low-E 110 0.370 41
Wall 2:Wood Frame,16"o.c. 1180 21.0 0.0 57
Window 2:Vinyl Frame:Double Pane with Low-E 122 0.370 45
Door 1:Glass 38 0.350 13
Door 2:Solid 18 0.300 5
Basement Wall 1:Solid Concrete or Masonry 916 0.0 10.0 68
Wall height:7.9'
Depth below grade:6.9'
Insulation depth:5.0'
Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 5 30.0 0.0 0
Furnace 1:Forced Hot Air 93 AFUE
Air Conditioner 1:Electric Central Air 13 SEER
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted
with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction
Code requirements.When a Registered Design Professional has stamped and signed this age,they are attesting that to the best of his/her
knowledge,belief,and professional judgment,such plans or specifica' this Code.
a
Name Title Si , Date
Project Title: New Single Family Residence Report date:09/02/09
Data filename:Y:\Howard Apartments\Sherman Ave Residence\Const.dwg's\Howard-Sherman.rck Page 1 of 4
CREScheck Software Version 4.2.2
NJ( Inspection Checklist
Ceilings:
❑ Ceiling 1:Raised or Energy Truss,R-38.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
Above-Grade Walls:
❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation
Comments:
❑ Wall 2:Wood Frame,16"o.c.,R-21.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1:Solid Concrete or Masonry,7.9'ht/6.9'bg/5.0'insul,R-10.0 continuous insulation
Comments:
Exterior insulation has a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends
at least 6 in.below grade.
Windows:
❑ Window 1:Vinyl Frame:Double Pane with Low-E,U factor:0.370
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 2:Vinyl Frame:Double Pane with Low-E,U factor:0.370
For windows without labeled U-factors,describe features:
Wanes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1:Glass,U-factor:0.350
Comments:
❑ Door 2:Solid,U-factor:0.300
Comments:
Floors:
❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation
Comments:
Heating and Cooling Equipment:
❑ Furnace 1:Forced Hot Air:93 AFUE or higher
Make and Model Number:
❑ Air Conditioner 1:Electric Central Air:13 SEER or higher
Make and Model Number:
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation.
Vapor Retarder:
Project Title: New Single
,.... ... .... ... _..._..._- _-.. _.- _... . ,_
Family Residence Report date:09/02/09
Data filename:Y:\Howard Apartments\Sherman Ave Residence\Const.dwg's\Howard-Sherman.rck Page 2 of 4
' LJInstalled on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification and Installation:
Lj Materials and equipment are installed in accordance with the manufacturer's installation instructions.
Lj Materials and equipment are identified so that compliance can be determined.
Lj Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces or outside the building are insulated to at least R-8.
Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to at least R-6.
Duct Construction:
Lj All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or
tapes.Tapes and mastics are rated UL 181A or UL 181B.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
Lj The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Ll Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone.
Electric Systems:
Ll Separate electric meters exist for each dwelling unit.
Fireplaces:
Fireplaces are installed with tight fitting non-combustible fireplace doors.
LI Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York
State,the Residential Code of New York State or the New York City Building Code,as applicable.
Service Water Heating:
Ll Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is part of a circulating system.
LI Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Project Title: New Single Family Residence Report date: 09/02/09
Data filename:Y:\Howard Apartments\Sherman Ave Residence\Const.dwg's\Howard-Sherman.rck Page 3 of 4
Table I'Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Project Title: New Single Family Residence Report date: 09/02/09