2009-453 �- TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building &Codes (318) 761-8256
( E I TIFICATE OF OCCUP-A-N- CY
Pernut Number. P20090453 Date Issued: Tuesday, April 13, 2010
This is to certify that work requested to be done as shown by Permit Number P20090453
has been completed.
Location. 4 PLEASANT Ln
Tax Map Number: 523400-302-017-0003-013-000-0000
Owner. BARBARA STEVES
Applicant: BARBARA STEVES
This structure may be occupied as a:
Fireplace
By Order of Town Board
Residential Addition TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the /
property owner of the responsibility for compliance with Site Plan, r )avp
Variance, or other issues and conditions as a result of approvals by the Director of Building&ODde El@orcernent
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20090453 Application Number. A20090453
Tax Map No: 523400-302-017-0003-013-000-0000
Permission is hereby granted to: BARBARA STEVES
For property located at: 4 PLEASANT Ln
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: BARBARA STEVES
4 PLEASANT Ln Fireplace
QUEENSBURY,NY 12804-0000 Residential Addition $19,000.00
Total Value $19,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans &Specifications
2009-453
507 sq ft residential addition with 1 fireplace
$75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday, September 23, 2010
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at thrown/fir Quby; / e sday, September 23, 2009
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
` i----_-ry--------------------"OFFICE USE ONLY --------...-------------• ' ±........-..........
00
TAX{P N/ s3 _/� PERMIT NO. J + 00
' � 00
0
FEES: PERMIT RECREATION ENGINEERING ;
-------------f- 1 L ---------------------- (It applicable}--- - -,' ---
--- '
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: / iU tJ OWNER: ',/G�i�it
ADDRESS: ?y• d X ADDRESS:/
PHONE NOS. ?9z /Z PHONE NOS. ::Z 98—C-12--*"Z
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE/'I4 i7��'„4i,JL• PHONE /— G
LOCATION OF PROPERTY.-
SUBDIVISION NAME: , ��'�] �/, L G S
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT Z
APPLY TO YOUR
PROJECT p Q p O com W LL W
w OJLL O�LL w Q 0-
OU
Z Q Q �C0 LL
N (A OLL 0LL dxo�y
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY(NO. )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
Toum of Queenslncry• Community Development Office • 742 Bay Road, Queenslniry, NY 12804
,1
f
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST-q �"-f_U G FUEL TYPE:_/(f,4 i'-
HEAT TYPE. ±.'5- y' *HOW MANY FIREPLACE(S) AND/OR WOODSTOVES(S):
ZONING CATEGORY: I ARE THERE WETLANDS ON THIS SITE? IV4f:)
IS THIS A HISTORIC SITE? AJO
PROPOSED USE OF BUILDING OR ADDITION: 4�/-I/"' 2rj- ,64
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? /V C)
ARE THERE EASEMENTS ON PROPERTY? /\j c0
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I
certify that the application, plans, and supporting materials are a true and complete
statement/description of the work proposed, that all work will be performed in accordance with the
NY State Building Codes, local building laws and ordinances, and in conformance with local zoning
regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain
a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by
a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of
occupancy.
I have read and agree to the abo
Signed
Director of Building &Codes: 761-8256 (for questions QUESTIONS? CALL 761-8256 OR EMAIL
regarding Building Permits, construction codes or septic codes(M-clueensburv.net
systems)
VISIT OUR WEBSITE FOR MORE INFORMATION
Zoning Administrator: 761-8218 (for questions regarding wWw.QU nsburv.net
required permits, the permit process, application requirements or to
schedule an appointment)
----
This application/proposed action described ; Permission is hereby granted to the above
herein is found to be in accordance with the ; Applicant to erect or alter the building described
zoning Laws of the Town of Queensbury. herein in accordance with said Application:
,
ZONING APPROVAL DATE BUILDING&CODES APPROVAL DATE
; 0 ,
10
-------------- ----------------------.----------------------
Toum of Qiieenslniry• Community Development Office • 742 Bay Road, Qiieensbury, NY 12804
Community Development Office
awry of Queensbury• 742 Bay Roach• Queeusbury, New York•12804
i
9 �
1
t
WTNDOWSGHEDULE '_____________________
JOB SITE/ADDRESS: �4=J Z Zdt, DATE: -/7-c:)<9
OWNER APPLICATION NO.:
WINDOW-
UNIT OR CLEAR CLEAR
WINDOW STOCK ROUGH ROUGH SFT. OPENING
NO,OR WINDOW STOCK O OPENING SPECIAL HARDWARE OR
MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT
LETTER NAME MODEUTYPE CALL WIDTH HEIGHT VENT OPENING ' WIDTH IN IN INSTRUCTIONS
ON PLAN SIZE INCHES INCHES
r r
2�1
7 ,� A 7� /4 l :- «�? ;� f�;I 22-710,16 sue '• ,-
B 26-LTR 11-05
-------------
aCoinniiinity Development Office
xown of Queensbury- 742 Bay Road■ Queensbury, New York -12804
---------------------
BUILDING PERMIT CALCULATION SHEET:
NATURAL LIGHT VENTILATION AND EMERGENCY EGRESS REQUIREMENTS
REa6IREB ACTUAL LIGHT REQUIRED SQUARE FOOT
HABITABLE ROOM AREA OF ROOM IN LIGHT SQUARE VENTILATION4% VENTILATION OPENING FOR REMARKS
SQUARE FEET 8%OF ROOM FOOTAGE OF ROOM AREA SQUARE EGRESS
AREA FOOTAGE
C-,4h,f!r e*W
QUESTIONS? CALL 761-8266 OR EMAIL
codes@gueensbury.net
VISIT OUR WESSITE FOR MORE INFORMATION
www.auensbury.net
B 10-LTR 11-20
Qzrearshal`sM Office
Town of Queensbury ■ 742 Bay Road - Queensbury, New York -12804
Michael J. Palmer,Fire Marshal-Gary Stillman,Deputy Fire Marshal i
--------------
APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS
Application is hereby made to the Building & Codes Office for the issuance of a Building & Use Permit
pursuant to the New York State Fire Prevention & Building Code. The applicant or owner agrees to comply
with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and
also will allow all inspectors to enter premises to perform required inspections.
IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED.
OWNER:Tx't2"*_'t"9 INSTALLER/BUILDER: ILI"'
ADDRESS: Ix ADDRESS: �D'_j r�� X
PHONE NOS. PHONE NOS. Z^���r/ �,
LOCATION OF PROPERTY: SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION:
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: ,add '% �i1�J�� PHONE:
✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL
INFORMATION
STOVE
FIREPLACE INSERT
FIREPLACE, FACTORY BUILT*
FIREPLACE,MASONRY
FURNACE(GARAGE ONLY)
*IF FACTORY BUILT, PLEASE PROVIDE: MANUFACTURER NAME: �i9�"�s s Y'C. MODEL NO.Z1z"Co
LISTED BY: NUMBER: QUESTIONS ?
CALL 761-8205 OT 761-8206
CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL:
firemarshal0gueensbury.net
MASONRY" CHECK ONE ✓ VIS(T OUR WEBSITE
SIZE IN FOR MORE INFORMATION
TILE STEEL INCHES www.aueensbury.net
FLUE CHECKONE ✓
DOUBLE TRIPLE WALL INSULATED DIRECT VENT CHIMNEY
WALL LINER
CHIMNEY MATERIAL CHECKONE ✓
**IF NON-MASONRY, PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO.
ADDMONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR
MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED
INSPECTIONS.
L/ ( '— 93-
Q�T007711
ity Development Office
aeensbury• 742 Bay Road• Queensbury, New York •128.04
Electrical Inspectors
THE FOLLOWING ELECTRICAL INSPECTION AGENCIES ARE CERTIFIED BY THE TOWN
OF QUEENSBURY TO PERFORM ELECTRICAL INSPECTIONS:
N Ss O INSPECTOR CONTACT NUMBER(S)
Commonwealth Electrical Inspection Services D aid Loveland Local Office:1-800-562-9934
176 Doe Run Road on Mumblo Ron: 518-798-0905
Manheim, PA 17545
Main Office: 1-800-873-6432
miciale epartment Local Office: 1-800-479-4504
143 Troy Schenectady Road Ray Novak 518-273-0861
Watervliet, NY 12189 (Office Hours: 7:00—9:00 AM)
Ray:369-6614
The Inspector, LLC Richard Moon Main Office- 1-800-487-0535
4755 McConchie Rd. Douglas R. Hull Local Office: (518)882-6140
Galway, NY 12074 Brian D. Sweet
David J. Irwin
New York Board of Fire Underwriters
40 Fulton Street-e Street Walter Sonntag Local Office: (518)373-7003
New York, New York 10038
PLEASE NOTE: WE CANNOT RECOMMEND AN INSPECTOR, HOWEVER, PLEASE ASK
YOUR CONTRACTOR WHO HE PREFERS TO INSPECT HIS WORK.
3/28/07
Framing / Firestopping Inspection Re
Office No. (518) 761-8256 Date inspection request received:
Queensbury Building &Code Enforcement Arrive: am/0M - t � am/pm
742 Bay Road, Queensbury, NY 12804 Ins _
Inspector's Initials:
NAME: PERMIT#:
LOCATION; INSPECT ON:
TYPE OF STRUCTURE:
Y Framing N WA C OMMEM:
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
xtedor Deck Bracing
•leadroom 6 ft. 8 in.
Votches/Holes/Bearing Wails
Natal Strapping for Notches Top Plate
1 %W 16 gauge 8 16D nails each side
)raft stopping 1,000 sq. ft. floor trusses
or less on center L`
ce and water sh 24 inches from wall ``7
on 1, 2, 3 hour
'ire wall 2, 3, 4 hour
irestoppin9 _-
'enetration sealed ✓?� s :�.'�_ i " - ��,:g
16 inch insulation in cav' min.
31ar3ige Fire Separation
House side%inch or 5/8 inch Type X _. ..w_.....
Garage side 5/8 inch Type X
-Ceilingfwall
Vindows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
:\Building&Codes Forms-OWeu9ding&Codesftpswon Fom AFramirq Fvestoppi#g irspec um RApgt.doc Revised Jw#nfy 7,20W
Framing / Firestopping Inspection Report -L' P
Office No. (518)761-8256 Date Ins=gpec request received:
tw ' , ' 1 (aG+o
Queensry Building 8 Code Enforcement Arrive: f�//vv arnt, arn/pm
742 Bay Road, Queensbury, NY 12&M ►ns is Initials;
NAME: U�L 1 �`i � � PERMIT A ', J
LOCATION: l INSPECT ON: t v U
TYPE OF STRUCTURE: jti
Y N A COMMENTS:
Framing
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Dedc Bracing
Headroom 6 ft. 8 in.
Notches/Holes I Bearing Walls
Metal Strapping for Notches Top Plate
1 i4 w 16 gouge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
An 6 ft. or less on center
ail ;2,4 inches from wall .
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
3arage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilinghyall
Mndows Habitable Space J Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above I below grade
5.0 sf grade
.:\BuNdhg&Codes FoM*-0i.D\8uNding&CodaVr4pedion Forrns\Frawft Fvwtoppft Irra Ubw Reporl.d=Revised January 7,2008
/I
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date l ' n request received:
Queensbury Building &Code Enibrmnent Arrive: Arnt rt: am/pm
742 Bay Road, Queensbury, NY 12MM lnspe s Initials:
NAME: �J► ` `�S PERMIT# ' 3
LOCATION: INSPECT ON: 1
TYPE OF STRUCTURE:
Y WA COMMENTS:
raming
Attic Access 22'x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12'O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'h w 16 gauge 8 16D nags each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on enter
Ice and water shield 24 inches from wail
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
9restopping
aenetration sealed
16 inch insulation in cavity min.
garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Cellingfwall
Nindows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
ABulk"&Codes Fomss-0L. SUVdWV&Codes4rapedion FomWFrwmr#9 FVedOPPOV Inspetlion RoportAoc RwiiuW Jmwfy 7,2008
M,,'T'
�hA2ts
Tom of Qaeessbsry RM Marshal
742 Bay Bead
QueemAwy,NY 12884
761-gM/7614M
fax 7454437
Factory Built Gas fte hce/Stove Inspection Report
stice:New York State rerprins that all LPL Laded,buttory built appiiasoes be iwaded a000rdisd to the kwbwdOm asd
is the butagadm Masoal uaootpasyisd the Wiia:oe.No deviation frmn the ssaardacasrer's
j mess or specifications is allowed.
r # 'I3 Schedule iims _LLI 1-1> "nine l 3d po aaythme Ldpcctor QK S
me �e UPS Ek ,Sf L Ing v�Fisat
iplia.oe Ari Fscarer . TL-44
Model# 40 13
rect Vent Fa6ory Belt Cbinsey I�C nmc S=e__bL Donble Wad Trifle Wad (asked
Yes No N/A Cs
oor Protection
earances to Consbostrbks(all sides)
restop(s) Vea dcai Chase
Walt Pametiradas—ig'
at Clearances to Combustibles Y
a t/Cbbaney Termination
io mey most be 3 feet above root'
ne ratios;2 fed above any combostible
abucam war Ile feed
n S6at-Off Valve
imbestion Air
nrth Ezteosion(if any)
�n 5`�j(je� ��TAY
mtel 2 W -,4 L
W above Op
fitness Operation
nk Placement Of LP)
Oe-BWIAw DepIL
_ZHERMAL INSULATiON
CELLULOSE THERMAL IMLATION 1.6 DENSffY*
Evaluation report G C,M,C No 09:3'L
As per standards CAN !i 160 kl�v�
LOOSE FILL CELLULOSE
COVERAGE CHART (0
II
PNEUMATIC APPLICATION 0
(D
IMPERIAL SYSTEM METRIC SYSTEM
SETTLED LbS 1 Ft.` Ft-'per 'RSI' As m-per
f 1 K. ba
APPLIED I SETTLED gr
FACTOR (INCH) FACTOR APPLIED imm) 11.3
(frun)
----------
R-10 (2.9) 2.7 0.36 69.44 RSI-1..O (44) 1 40 1.00 1 11.3 0
R-12 (D
0.43 58.14 RSI-2.0 (87) 79 1.99 5.68
R-20 (5.9) 5.4 0.72 34.75 RSI-3.01 (131) 119 3.04 3.72 0
R-28 (8.3) 7.5 1.00 25-00 RSI-4.0 (174) 158 4.06 2.78
to
-7 (8.9) 8.1 1.08 3.15 RSI-5.0 (218) '198 5.07 2.23 R-30
...........
R-32 (9.5) 1 8.6 1.14 21.92 RSI-6.0 1 (262) 1 238 i 6.09 -11.86
-3 9.4 1.25 20.00 7.09 1.60
(10.4) RSI-7.0 (305) 277 0
317 RSI-8.0 (349)_�1.9) 101 1.44 1 1736 8.10��R-405 .40
R-50 (14.9) 13.5 1_ 1.80 13.88 RSI-9.0 (3931) 357 9.12 1.24 Go
Cn
R-60 1 (17.8) 16.2 1 2.16 11-58 RSI-10.81. (472) 428 1 10.94 1.03
_- ----____I_J
*SETTLED DENSITY:1.6 lb.PER CUBIC FOOT/25.6 kg,
Cn The thermal iestslane and settled National Research Council Of Canada 00
dwst�f.Berio-therm fnsuWion nas BuHdft Research Institute .14
been tested Lv REPORT CIR 6021.1 00
I + MEM13ER (D w 0
The minimum density for injection in cavity is 3.0 tbs.per V r�a C
Increase coverage due to structural space rCWAC#� N) M
(example.add 10%coverage when blo!!t!x,&) N.) "D CO
M
MAIM'HAYS •
ENERGY GUARD INSf_.f11_Nr!01A
NAME OF APPLICATOR; 4449 RT 9N, 0
P 0 RT C 0 R N E P S, N Y Xl U)
C ADDRESS: fa r C=
-
ts Z >
4 MeA 0 ;-1
GFW" CD 0
DATE OF APPLICATION:day /month /year Z010 CL 0 U 0 z
cn
Z
THICKNESS INSTALLED If ce MANUFACTURED BY- rn
0 Attte-Piope-3 111111MMER 1.1101 w 0
SIGNATURE ;:m-. -0 > >
1111111110M WNW 0
1451 Nobel n PI
Ste-Julie,Qu6bec 0 0
J3E 1Z4 3
ch cn
IEV.01-96)
Rough Plumbing / Insulation 1nSpeC Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Cade Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
a i
NAME: ��� PERMIT#: 7- 4Y3
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing / Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washi2q Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
ad
50 P.S.1 or 15 minutes =y
Insulation 6 Residential Check/Commercial Check 8
jyvek or imilar Exterior Sealant V
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
7// -r✓��/
Queensbury Building & Code Enforcement - Re ' ential Final Inspection
k -._.-
Office No. (618)761-8256 Arrive: am/pm Depart: 9 am/pm
Date Inspection request received: Inspector's Initials: KA
NAME: PERMIT#:
LOCATION: DATE:
TYPE OF STRUCTURE:
._.� Comments:
Y
,V Building Number Address visible from road
Chimney,Height/"B"Vent/Direct Vent Location
Fresh Air intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs decks floc more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade awav from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safe glazing
Interior Smoke Detectors Carbon Monoxide Detectors
Every level: Eery Bedroom:
Outside every bedroo area:
Inter Connected: Bp
tte backup:
Attic access 30 inches x 22 inches x 30 inches W ht in accessible area
Crawl Spaces 18 inch x 24 inch access 1 sq.ft.-150 sq.ft.vents
Bathroom Fans if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to fumace area
Fumace/Hot Water Heater op2rating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%*G sum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed pSnrly
Gas Loge in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Are Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built SWic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection FornsWesidential Final Inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08
REScheck Software Version 4.3.0
Compliance Certificate
Project Title: Addition over garage
Energy Code: 2007 New York Energy Conservation
Construction Code
Location: Warren County, New York
Construction Type: Detached 1 or 2 Family
Heating Type: Non-Electric
Glazing Area Percentage: 13%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Contractor:
4 Pleasant Lane Matt&Barbara Steves Matt Cifone
Queensbury,NY 12804 4 Pleasant Lane Cifone Construction Co.Inc.
Queensbury,NY 12804 PO Box 684
518-792-8474 Glens Falls,NY 12801
mtt@1-survey.com 518-792-9242
mcifone@cifone.com
Compliance:
Compliance: Maximum UA:127 Your UA:93
Gross Cavity Cont. Glazing UA
Assembly Area or R-Value R-Value or D..
Perimeter U-Factor
Ceiling 1:Fiat Ceiling or Scissor Truss 441 38.0 0.0 13
Wall 1:Wood Frame,16"o.c. 680 21.0 0.0 34
Window 1:Wood Frame:Double Pane with Low-E 15 0.300 5
Window 2:Wood Frame:Double Pane with tow-E 15 0.300 5
Window 3:Wood Frame:Double Pane with Low-E 13 0,300 4
Window 4:Wood Frame:Double Pane with Low-E 13 0.300 4
Window 5:Wood Frame:Double Pane with Low-E 15 0.300 5
Window 6:Wood Frame:Double Pane with Low-E 9 0.300 3
Window 7:Wood Frame:Double Pane with Low-E 9 0.300 3
Floor 1:All-Wood Joist(Truss:Over Unconditioned Space 441 25.0 OD 17
Fumace 1:Forced Hot Air 90 AFUE
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted
with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction
Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her
knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code.
Name-Title Signature) *De
Project Title:Addition over garage Report date:09/17/09
Data filename:Untitied.rck Page 1 of 4
REScheck Software Version 4.3.0
Inspection Checklist
Ceilings:
❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.300
For windows without labeled Ufactors,describe features:
#Panes Frame Type Themnai Break? Yes No
Comments:
❑ Window 2:Wood Frame:Double Pane with Low-E,U-factor.0.300
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑Window 3:Wood Frame:Double Pane with Low-E,U-factor.0.300
For windows without labeled 1.!-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑Window 4:Wood Frame:Double Pane with Low-E,U-factor.0.300
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑Window 5:Wood Frame:Double Pane with Low-E,U-factor:0.300
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?—Yes No
Comments:
❑Window 6:Wood Frame:Double Pane with tow-E,U-factor.0.300
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 7:Wood Frame:Double Pane with Low-E,U-factor.0.300
For windows without labeled U factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Floors:
❑ Floor 1:All-Wood Soist/Truss:Over Unconditioned Space,R-25.0 cavity insulation
Comments:
Heating and Cooling Equipment:
❑ Furnace 1:Forced Hot Air.90 AFUE or higher
Make and Model Number.
Project Title:Addition over garage Report date: 09/17/09
Data filename:Untitled.rck Page 2 of 4
Air Leakage:
Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation.
Vapor Retarder:
Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification and Installation:
Materials and equipment are installed in accordance with the manufacturer's installation instructions.
Insulation is installed in substantial contact with the surface being insulated and in a manner that achieves the rated R value.
Materials and equipment are identified so that compliance can be determined.
Manufacturer manuals for all installed heating and doling equipment and service water heating equipment have been provided.
Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
Duct Insulation:
Supply ducts in unconditioned attics or outside the building are insulated to at least R-11.
Return ducts in unconditioned attics or outside the building are insulated to at least R-6.
Supply ducts in unconditioned spaces are insulated to at least R-11.
Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements.
Duct Construction:
All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic plus-embedded-fabric,or
tapes.Tapes and mastics are rated UL 181A or UL 181 B.
Exceptions:
Continuously welded and locking-type longitudinal joints and warns on ducts operating at less than 2 in.w.g.(500 Pa).
The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone.
Electric Systems:
0 Separate electric meters exist for each dwelling unit.
Fireplaces:
Fireplaces are installed with tight fitting run-combustible fireplace doors.
Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York
State,the Residential Code of New York State or the New York City Building Code,as applicable.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is part of a circulating system.
Circulating Hot Water Systems:
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Swimming Pools:
All heated swimming pools have an onloff heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Project Title:Addition over garage Report date: 09/17/09
Data filename: Untitled.rck Page 3 of 4
Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Saes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Temperature("F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range("F) 2"Runouts 1"and Less 125"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIEF:(Building Department Use Only)
Project Title:Addition over garage Report date:09117/09
Data filename: Untitled.rck Page 4 of 4