Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2009-477
r TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20090477 Date Issued: Tuesday, December 08, 2009 This is to certify that work requested to be done as shown by Permit Number P20090477 has been completed. Location: 1048 STATE ROUTE 9 Tax Map NN, umber. 523400-296-009-0001-012-000-0000 Owner. GAM OF THE ADIRONDACKS, LLC Applicant: JOHN MILLER This structure maybe occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the f owner of the responsibility for compliance with Site Plan, property P P Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY (2t 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090477 Application Number. A20090477 Tax Map No: 523400-296-009-0001-012-000-0000 Permission is hereby granted to: JOHN MILLER For property located at: 1048 STATE ROUTE 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: 1048 STATE ROUTE 9, LLC 1066 STATE ROUTE 9 Commercial Alteration $50,000.00 QUEENSBURY,NY 12804-0000 Total value $50,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications '.009-477 350 sq ft commercial alteration 722.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday,October 05, 2010 er period is required,an application for an extension must be made to the code Enforcement Officer m of Queensbury before the expiration date.) $e ;n oftitiQuee ur �tday,October 05, 2009 ' for the Town of Queensbury. Director of Building&Code Enforcement .. /)- 9 (- ---.---- OFFICE USE ONLY -------------------------E TAX MAP NO. PERMIT NO.o FEES: PERMII� RECREATION ENGINEERING a '7'7 j = (if applicable) ............. ..r-.�-__.____...__......... _. .. - _._.. PRINCIPAL STRUCTURE..-—— APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A ALID P MI F R , STRU TI N, APPLICANT/BUILDER: JUtClV IL, OWN 1V volt UL&Q- ADDRESS: ((298 � �J� a2�� ADDRESS: 4�11)1-L 9A:j PHONE NOS. S( �C 3�0— ^7�Q �Y( (jib PHONE NOS. (Q���' -70,� CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: LOCATION OF PROPERTY: �(J J O � a)4-Plt�4uYZ,�{ ICU HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? ❑ YES NO IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z — � APPLY TO YOUR z 1 LL PROJECT 0 � J 0 I- w o w l LL w L = Q CCL ) Q z ! Q Q d NU) 0LL F- LL CLM06 r- SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO. of UNITS ) j TOWNHOUSE B� USiNESS OFFICE � I + RETAIL- --'— I MERCANTILE rj(J FACTORY OR �INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL 4R INDUSTRIAL-NAME OF BUSINESS: t'' LJ L�� 4nieno10.i�� �� ESTIMATED CONSTRUCTION COST: 5(2 6,-10 � FUEL TYPE: N A�rt_�A-t � HEAT TYPE h;v1nA 1-L rA,- *HOW MANY FIREPLACE(S):j AND / OR WOODSTOVES(S): __ B 3-LGL 11-05 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? t"� ARE THERE EASEMENTS ON PROPERTY? I)o I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete state me nt/d escri ptio n of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to e. Signed r Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) _______% ;...._..__....._______._._.___------.___._._...____ 01 11 Permission is hereby granted to the above o This application / proposed action describedo Applicant to erect or alter the building ; herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. ; o Application: o o BUILDING & C E PROVAL ; ZONING APPROVAL , , o DAT + DATE o ...................... QUESTIONS? CALL 761-8256 OR EMAIL codes(ibmueensbury.net Office Use Only VISIT OUR WEBSITE FOR MORE INFrIMAA '^" Rough Plumbing / Insulation lnspectio Report Office No. (518) 761-8256 Date In pection e ed• Queensbury Building &Code Enforcement Arrive: a e 742 Bay Road, Queensbury, NY 12804 Inspector's Initia s: . NAME: r le PERt�6 #: / LOCATION: INSPECT ON: E OF STRUCTURE: Y N NIA Now umbin N en in Lace 1 Z rn minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test vI Drain/Vent ✓ -'Air dead P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test G Water �Supply Piping 50 P.S.1 for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If Tguired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: , Rough Plumbing Insulation Report.revised Nov 17 2003, revised Febnvary 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date inspection req Queensbury Building &Code Enforcement Arrive: .-a a� 742 Bay Road, Queensbury, NY 12804 Inspector's Initrai t NAME: D O Y, AJD10 MIT#: q _ -71 LOCATION: gy h �AT� © TE I PECT ON: i TYPE OF STRUCTURE: Framing Y N HLA COMMENTS: Attic Access 2T x W minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly IT O.C. Headroom 6 ft. 8 in. Stairwells 36 in, or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes I Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge $ 18D naAs each side Draft stopping 1,000 sq. fL floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wail Fire separation 1, 2, 3 hour re wail 2, 3, 4 hour �— Firestopping k Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 518 inch Type X Garage side 5/8 inch Type X Ceilinalwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-OLMufiding&CodesUrispec ion FonysTra rr ing FFnosbpping Inspowon Papoft.doc Revised Jonval 7,2008 2 - /V AI&MeS 4Wol- Commercial Final Inspection ReP014 Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart�m/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: k A J PERMIT#: LOCATIO Xe DATE: COMMENTS: Y N NA Chimne /"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. S acin Platform/Decks Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Re lator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure I hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%> 1000 s .ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" �... Smoke Vents Or Fan,if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Buildin or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C L:\Building&Codes Forms\Building& Codes\Inspection Forms\Comore ial F' al Inspection Report.doc Inspection for Permit to Oc py Fire Marshal's Office Request Rec'd Permit No. �- Town of Queensbury Qu Bay Road /f `�/�,s Queensbury,NY 12804 Scheduled Inspection Date: /'�JCO Cs / Time: k 0 , gjl�k- Phone: (518)761-8206 Business Nam . Fax: (518)745-4437 Location: Type of Inspection N/A Yes No EXITS: Exit Access Exit Enclosure All COMMENTS Exit Discharge AISLES: Main Aisle Width ✓' Secondary Aisle Width EXIT SIGNAGE Sign-normal y" Sign-battery EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: / /1J Hun Inspection of extinguisher FIRE ALARM SYSTEM Fan Shutdown Fire Sprinkler System (FDC) y Fire Suppression-kitchen t/ Fire Suppression-Gas Islan ✓ Generator Hood Installation Elevator Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical O�+ Electric Wiring Enclosed/Labeled Combustible Waste Vehicle Impact Protection Knox Box Z.� L9sGy ?{ -' iLLtt G F.D.Si na e-Utility Rooms No Smoking Signs Maximum Occupancy Sign Emergency Evacuation Plan ❑ Approved (it no other approvals apply,the B&C Office will issue the Certificate of Occupancy) 'Denied / call for Recheck Inspected'ev-�. ler, `_ L:\FireMarshal\FM Forms Masters\permitto occupyform.doc Commercial Final Inspection Report Office No.: (518)761-8256 Date Inspection re s iv Queensbury Building&Code Enforcement Arrive: = a epart: am/ 742 Bay Road,Queensbury,NY 12804 Inspector's Initia s. ` NAME: ►r�, rr r 1 �i ec�E T `-' —Z 7 LOCATIdN: DAT . COMMENTS: Chimney/"B"Vent/Direct Vent Location Plumbing Vent Throug4 Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks _ Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s .ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if re wired Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'h doors > 10%> 1000 s .ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire StoppinE,3,000 s . ft. Wood Frame Attic Access 30"x 20" 0"(h),Crawl Space Access 18"x 24" �` � Smoke Vents O a e uired Elevator O eration and Si a e/Shaft Sealed Af L� + Handicapped Bat om Grab Bars/Sinks/Toilets Handicappe at king Lot Si na e Public Toile om Handicapped Accessible L Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Drive—way Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Tem . or Permanent C/O Okay To Issue C/C L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc 2 -/77/ �� Commercial Final Inspectio epprt Office No.: (518) 761-8256 Date InsLN- ra equ r e Queensbury Building&Code Enforcement Arrive: Depart:742 Bay Road,Queensbury,NY 12804 Inspectors nitials. NAME: --Rt(�e r M 1e 1� PERMIT07 LOCATION: 7 DATE: COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads I1" Vestibules For Exit doors>3000 s .ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Re lator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'h doors > 10%> 1000 s . ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation ano Si a e/Shaft Sealed HandicappedJasThkoofn Grab Bars/Sinks/Toilets Handicappe Battjarking Lot Si na e Public Toilet 9andica ed Accessible Handica ed Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certifica# ' As-built Septic System Layout Required or On File 1, Building Number or Tenant Address on Building or D Water Fountain or Cooler Building Access All Side urface 20'wide Okay To Issue Tem . rmanent C/O Okay To Issue C/C L:\Building&Codes Forms\Building&CodesUnspection FormslCommercial Final Inspection Report.doc �-Zl Inspection for Permit to Occupy Fire Marshal's Office Request Rec'd Permit No. 07-//77 Town of Queensbury Bay Road Qu Time: 'ram Queensbury,NY 12804 Scheduled inspection Date: Phone: (518)761-8206 Business Name: !� l t'� ��� A Fax: (518) 745-4437 Location: Type of Inspection N/A Yes No EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width AC Secondary Aisle Width EXIT SIGNAGE Sign-normal Sign-battery EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: Hun Inspection of extinguisher FIRE ALARM SYSTEM Fan Shutdown Fire Sprinkler System FDC Fire Suppression-kitchen Fire Suppression-Gas Islan Generator Hood Installation Elevator Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical Electric Wiring Enclosed/Labeled Combustible Waste Vehicle Impact Protection Knox Box F.D.Si na e-Utility Rooms ] �. Smoking Signs M Maximumum Occupancy Sin f/ Emergency Evacuation Plan ul' Approved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) � v) ❑ Denied / call for Recheck Inspe ted By. - L:\FireMarshal\FM Forms Masters\permitto occupyform.doc FIRE MARSHAL'S OFFICE Tmun of Queensbunj 742 Bay Road, Queensbury, NY 12804 " Nonce of Natural Beauty ... A Good Place to Live " PLAN REVIEW Adirondack Audio 09-477 10/16/2009 I have reviewed the current submitted drawings for the above project, and offer the following comments. 1) Fire ext locations to be determined 2) FM and DFM toured site with GC. Locations for exit signs, EL's and combos identified and marked up on drawings. 3) Confirmed with GC no stove in kitchen area Fire Marshal Michael J Palmer 742 Bay Road Queensbury NY 12804 518 761 8206 firemarshal@queensbury.net Fi r e M a r s h a l 's Off i c c - P h o n e: 518-761-8206 - F a t: 518-745-4437 fireurarslial@giteeiislniinLEet - z ymv.queensbuUme MAI Al t V � I J o�� /rIr11 HANDICAPP TOILET ROOM DOTES: — ALL TOILET ROOM ACCESSORIES INCLUDING -IXTURES,DISPENSERS, GRAB BARS. ETC. SHALL BE INSTALLED ACCORDING TO ALL GOVERNING CODES. — PROVIDE HANDICAPPED ACCESSIBLE CONTRO S ON ONE LAVATORY IN 1 / E e r u Tnir ET ROOM — THE TOILET RIM IS TO BE A MAXIMUINA OF 1 -HE SINK ;ailA S �0 B A MAXIMUM OF 34' AFF — PROVIDE FABRIC SAFETY COVERS ON WATE SUPPLY AND DRAIN PIPES UNDER LAVATORY. — PROVIDE SOLID BLOCKING WITHIN STUD WA-I S FOR ATTACHMENT OF GRAB BARS. 8,_�„ 30 HANDICAP i ! �— I 5)—O,p r 6 36 8'-1" 18" 5'-1" 18" CD rl HANDICAP HANDICAP LAVATO Diff x T , A1l AT�► 1 HANDICAP MINIMUM FIXTURE CLEARANCES 8'-10" 8'-10�� I I r 2f-61) I co 42" 63' i c c I 1 7"MAX rn z o s� i i HANDICAP HANDICAP LAVATORY LAVATORY