Loading...
2009-522 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 uE RTIFI .A►TE 01-1'r C0MPL1-A-N' %'1..,E Permit Number. P20090522 Date Issued: Monday, December 06, 2010 This is to certify that work requested to be done as shown by Permit Number P20090522 has been completed. Tax Map Number: 523400-297-017-0001-035-000-0000 Location: 79 MEADOW Dr Owner. AMY MC LAUGHLIN Applicant: AMY MC LAUGHLIN This structure maybe occupied as a: Demolition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Uire� r of Building& of ement Planning Board or Zoning Board of Appeals, TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090522 Application Number. A20090522 Tax Map No: 523400-297-017-0001-035-000-0000 Permission is hereby granted to: AMY MC LAUGHLIN For property located at: 79 MEADOW Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: AMY MC LAUGHLIN 79 MEADOW Dr Demolition QUEENSBURY,NY 12804-0000 Total value Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-522 DEMOLITION OF GARAGE $20.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday, October 26, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the(T'o(TO NM Que band , October 26,2009 SIGNED BY for the Town of ensb Que ury. Director of Building&Code Enforcement r 7 -, ! y J OFFICE USE ONL ` + o TAR MAP NO PERMIT NO, �F` AID ° Permission is hereby granted to the above named Applicant to demolish the building s described herein as set forth in the Application below. nrT f Director of Building&Codes Date T DOWN"0'E SLaR APPLICATION FOR DEMOLITION PERMIT: Fill in applicable spaces and submit two(2) plot plans, drawn to scale,showing lot boundaries with dimensions and adjacent roads/streets. Show all existing structures on the property and indicate which are to be demolished. Indicate on the plot plan the location of all utilities. APPLICANT/BUILDER�A,A1 rl O I G e rS OWNER: A►�? y Qi Gke/S®n ADDRESS: 7 111Ae c-,4 d w V✓Y v e 7 ADDRESS: 7 Ct d r,'vc PHONE NOS. S( W - 9"36- 'I`t44 PHONE: 56 6 Q 3- O / 3 1 PERSON RESPONSIBLE FOR WORK: r5e, l i ok.arSon PHONE: S l Y -6 3 6- I V y C LOCATION OF DEMOLITION: 7 `t /1A e-ex J d— /9,- G%e e»f S%e;, /(/ Y WHERE WILL DEMOLITION MATERIAL BE DISPOSED? R d/1 0 Ft" ASBESTOS INFORMATION: ✓ Is there any asbestos within the building to be demolished? YES NO ✓ If YES, our office needs the following information: o Name of firm removing the asbestos: o License number of firm: o Indicate where the asbestos material will be disposed: NOTE:A copy of Asbestos Removal Report must be filed with our office before demolition begins. STRUCTURE INFORMATION: ✓ Indicate which structure(s)will be demolished: RESIDENCE GARAGE BUSINESS STORAGE BLDG. OTHER ✓ Size of structure: 2 � X 2 ✓ Number of stories: ✓ Foundation type: FULL CELLAR CRAWL SPACE SLAB x ✓ Foundation: WILL BE REPLACED X WILL NOT BE REPLACED ✓ Structures(s): WILL BE REPLACED_ WILL NOT BE REPLACED UTILITIES INFORMATION: ✓ Indicate utilities for this structure: GAS ELECTRIC X PROPANE PUBLIC WATER ONSITE WELL-WATER PUMP PUBLIC SEWER Have you notified the Town Water Dept. for public water and public sewer disconnect? YES NO_ZC Have all utilities been disconnected: YES NO X =? CALL1-8256 OR EMAIL sbury.notSIGNAT E OF APPLICANT ORE INFORMATION 6 ) bury.net Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 RE CENED 100 OF QUEENSBURY P€c It PAO P oI,(C 0 AAW1 Ex6J'7f N6r / X/6 d o G, vti /Y-,# 06-c/<- 4774' c&W 70 X7 air, 3 AM" % e E pNtd AA/L iv iTi& .t P/JU�4 tii; � s j tj o o our lirm'Z ;r,?inat;vn, complia .e,rrith of r commzmts shall not a Fc,tru€r' a ing the pl s and spe;66 ons gK<Ull c mpliar with the Ui epf z ew York State. I IV r" -,,c4 Queensbury Building & Code Enforcement - R Idential Final Inspection Office No. (518) 761-8256 Arrive: am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUC URE: ! �'7 Cginments: _ N A 40 Building Number Address visible from road Chimney Height/"B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbina Vent through roof minimum 6 inches Roof Co late/Exterior Finish Com ete Platform at all exterior doors Handrail 4 or more risers - - - -�---- Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handica Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to silt plate Gas Valve shut-off a osed/regulator 18 inches above grade Interior priM/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safetv glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic seem 30 inches x 22 inches x 30 inches he! ht in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft,vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft sto ng finished basement 1,000 s ,ft. Emergengy egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/"Gypsum Basement stairs closed rise>4 inches Gara a Floor Pitched Garage fireproofingI%hour fire door/door closer Duct worts Sealed proDerly Gas Logo in Sealed or Glass Enclosure Final Electrical _ Final Survey Plot Plan Are Fault Breaker in Bedrooms �1 a t Flex Gas Pipe Bondin As Built Septic System/Sewer Dept. Inspection Sticker t Site Plan /Variance required Flood Plain Certification,it re aired Okay to issue C I C or C 10 1 Tem rary/Permanent LABuilding&Codes Forms\Building A Codesllnspection ForrnsWesidential Final Inspection Form revised_100405.doc;Revised January 7,2008;Revised e/26/08 Queensbury Building & Code Enforcement - ft i ential Final Ins ection p ce No. (518)761-8256 Arrive: am/pm rt: am/pm Date Inspection request received: Inspector's Initials: NAME: Ak4LPERMIT#: DeDa 6 c � LOCATION: -, ' , DATE: TYPE OF STRUCTURE: ' c% Comments: 4" Building Number Address visible from road Chimney,Height/°B'Vent/Direct Vent Location Fresh Air Intake _2 3 inch PlumbingVent through roof minimum 6 inches / �' ! Roof Co /Exterior Finish Com ete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks ios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck aches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Brach /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off /regulator 18 inches above grade Interior /trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety /Window in stairwells Mfet y glaft Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: B@Ley backup: Attic access 30 inches x 22 inches x 30 inches(height)in acoessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents Bathroom Fans if no window Plumbina fixtures Foundation insulation/Insulation Certification Floor truss draft stopping finished basement 1,000 sq.ft. Ememew earess below grade Gas Furnace shut off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater ograting Low water shut-off boiler Relief Vakre s installed/Heat T Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garape Floor Pitched Garep tweproofing/%hour fire door/door.closer Duct work Sealed Gas Low in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc fault Breaker in Bedrooms Flex Gas PIp2 Boriding As Built Septic System/Sewer Dept. Ins on Sticker Site Plan /Variance required Flood Plain Certification if required Okay to issue C/C or C 10 Temporary/Permanent LABuilding&Codes Form"uilding&CodeMinspec tlon FormsiResidenb Inspection Form revised_100405.doc;Revised January 7,2008;Revised 6/2601