Loading...
2009-543 I I SEPTIC SYSTEM GENERAL NOTES: APPROXIMATE LOCATION OF EXISTING FAILED1. SEWAGE SEWAGE DISPOSAL SYSTEMS SHALL NOT BE INSTALLED IN WET OR FROZEN SOIL. SEPTIC TANK-PUMP 2. THERE SHALL BE NO VEHICULAR TRAFFIC OVER THE SEWAGE DISPOSAL SYSTEM. PRIOR TO CONSTRUCTION, AND REMOVE IN ITS I ` `" - ' -"�- THE AREA OF THE SYSTEM SHALL BE STAKED OUT AND FENCED OFF. ENTIRETY i, ! f _ - E _ __.� r�- 3. THE SANITARY DISPOSAL SYSTEM HAS BEEN DESIGNED IN GENERAL CONFORMANCE OF"APPENDIX 75-A, WASTE TREATMENT-INDIVIDUAL HOUSEHOLD SYSTEMS, NEW YORK STATE SANITARY CODE". L5 `� 45° BEND WITH 4. CELLAR, ROOF,AND FOOTING DRAINS SHALL NOT BE DISCHARGED INTO THE SEPTIC SYSTEM OR IN THE D VICINITY OF THE ABSORPTION FIELD. 009 CLEANOUT(TYP) O 5. THE SEWAGE DISPOSAL SYSTEM HAS NOT BEEN DESIGNED TO ACCOMMODATE GARBAGE GRINDERS OR NOV 0 3 2 UNVERIFIED EXISTING ! ! ! !, i 1 f 1 I 1000 GAL. SEPTIC TANK- i d� ` . 4" INV. IN =379.50't FAILED SEPTIC FIELD TO If+ I i I �. I.•� WATER SOFTENER BACKWASH. I + I ! l i ! s I ! 6. HOUSE SEWERS ARE LAID ON FIRM FOUNDATION AT A MINIMUM GRADE OF ONE-QUARTER INCH PER FOOT Tp OF QUEENSBURY 4" INV. OUT=379.25't BE REMOVED IN ITS , It ! I! i tl ���'! Ij W PREFERABLY WITHOUT BENDS. AT LEAST ONE CLEANOUT WITH A PROPERLY FITTED PLUG IS TO BE BUILDING&CODES FERNCO TO EXISTING ENTIRETY l�t ' '. i I�''' '� I Ili W PROVIDED. THE HOUSE SEWER SHALL ALLOW FOR VENTING OF GASES FROM THE SEWAGE SYSTEM. HOUSE SEWER,WYE, 4"PVC f�l I�i t i I i ICI sl I I ,. 7. HOUSE SEWER CONSTRUCTION INCLUDING MATERIALS SHALL COMPLY WITH THE APPLICABLE REQUIREMENT EXISTING FENCE AND VERTICAL Ip� ! -- - CLEANOUT TO GRADE SCHED ° I{ I II II !! !� I ! j � rn OF THE PLUMBING CODE OF NEW YORK STATE. � b 40 @ 2/o 4 SDR 35 1/o .1 L--- - 'ti INVERT 380', � t- _ ,-- i I ! `- 8. A MINIMUM HORIZONTAL SEPARATION OF 10 FEET SHOULD EXIST BETWEEN THE HOUSE SEWER AND ANY c� �, ( , , ! - -- - R 0 WATER LINE. WHERE LINES MUST CROSS,THE WATER SERVICE LINE SHALL BE AT LEAST 18 INCHES ABOVE APPROX. GRADE AT 106't r` - _ m_P ` --. - _ -- ' 1�_ ', ' ! ' I I�-I 6 THE HOUSE SEWER. IF A WATER LINE MUST PASS BELOW THE HOUSE SEWER,THE VERTICAL SEPARATION EXISTING TREELINE ELEVATION 382't) �P i '- I I II ; `; s 1 W �. MUST BE AT LEAST 18 INCHES. I 10, + i ' I ' I i ; y 9. SUCTION WATERLINES SHALL NEVER CROSS UNDER HOUSE SEWERS OR ANY OTHER COMPONENT OF THE W • . , , . • s I �..,� + : , ; ! I � 'ate SEWAGE SYSTEM. ! + I I I ' ! ; J 10. ANY CHANGE IN DIRECTION OF HOUSE SEWER PIPE WILL REQUIRE A CLEANOUT. OH ELECTRIC LINE- ' ' ' 10' ELJEN IN DRAIN SYSTEM ! i + ', it N N 11. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY 12'FROM GRADE ' ' O 1 7 UNITS/TOTAL 28-FEET I 'I ' °i ii ! ' p ENGINEER OF ANY DISCREPANCIES. 1 ", 1 I ', °,o _ !' �' w PROJECT _ _ ! 12. CONTRACTOR TO FIELD LOCATE ALL EXISTING SEPTIC SYSTEM COMPONENTS PRIOR TO CONSTRUCTION FOR K1` COORDINATION WITH NEW SYSTEM SPECIFIED. CONTACTOR TO REMOVE AND PROPERLY DISPOSE OF ALL :•.. I EXISTING BUSH i - o SITE I I_ EXISTING SEWAGE COMPONENTS NOT INDICATED TO REMAIN. j TO BE REMOVED 13. IT IS CONTRACTOR'S RESPONSIBILITY TO COORDINATE AND VERIFY ACCESS REQUIRED TO COMPLETE WORK �( 1 } o DRIVEWA TH#1 f ! i i 1 I W SPECIFIED WITH OWNER PRIOR TO CONSTRUCTION. �• , 14. ALL DISTURBED AREAS TO BE TOPSOILED, SEEDED,AND MULCHED AFTER BACKFILLING AND RE-GRADING. ,. ..' .'. .. :: " BUSH f BUSH !W 111 t I s 3 V 15. CONTRACTOR TO LAY OUT ENTIRE SYSTEM TO VERIFY DEPTHS, INVERT ELEVATIONS, BOUNDARY LINES AND W Ii SETBACKS IN ACCORDANCE WITH PLANS PRIOR TO CONSTRUCTION. WHERE LOT LINES ARE NOT KNOWN OR j iy ', °I ? I ', ', CANNOT BE VERIFIED FROM SURVEY FIELD MARKERS, CONTRACTOR SHALL EMPLOY SURVEYOR FOR FIELD �� TOTAL AREA !` I !! li IF ' -� ! I W , c VERIFICATION OF PROPERTY LINE LOCATIONS PRIOR TO CONSTRUCTION. 1 �� IL 0 16. CONTRACTOR SHALL NOTIFY LOCAL JURISDICTION AND ENGINEER FOR FIELD OBSERVATION OF SYSTEM , 0. 14 + Ac. PT 1 i EXISTING FIREPLACE 1 i LU INSTALLATION PRIOR TO BACKFILLING. m TO BE REMOVED 17. CONTRACTOR TO OBTAIN ALL NECESSARY PERMITS PRIOR TO START OF WORK. ' � . W w 22' 18. CONSTRUCTION OF THE SANITARY DISPOSAL SYSTEM SHALL BE PERFORMED UNDER THE GUIDANCE OF A W `-` � NEW YORK STATE LICENSED PROFESSIONAL ENGINEER. CERTIFICATION THAT THE INSTALLATION WAS MADE N IN ACCORDANCE WITH THE APPROVED PLANS AND APPENDIX 75-A WASTEWATER TREATMENT STANDARDS ul I 10 32 OHIO AVENUE, QUEENSBURY,N.Y. Uj CD EXISTING FOR INDIVIDUAL HOUSEHOLD SYSTEMS SHALL BE MADE TO THE NEW YORK STATE DEPARTMENT OF HEALTH W PORCH 2 BEDROOM HOUSE t EXISTING TAX I.D. NUMBER 309.13-1-20 0 AND THE LOCAL CODE ENFORCEMENT OFFICER. o �� ,ad STING WOODEN ( ) z o N � 5.3 FENCELINE CN SEPTIC TANK NOTES: t e-AS1DEWA"` SITE LOCATION MAP } rn CD - NOT TO SCALE O 4) z CV Q i N 1. THE MINIMUM DISTANCE BETWEEN THE INLET AND OUTLET SHALL BE SIX FEET. I : vi 00 � C'1 2. TANKS MUST BE WATERTIGHT, CONSTRUCTED OF DURABLE MATERIAL NOT SUBJECT TO CORROSION, DECAY, FROST cn ' L CO LL DAMAGE, OR CRACKING. AFTER INSTALLATION,ALL SEPTIC TANKS SHALL BE ABLE TO SUPPORT AT LEAST 300 POUNDS PER O 7 L LO SQUARE FOOT(PSF). ' • .. G: :. GE d yo" ... '. .. � �3. TANKS WITH A LfQUID DEPTH OF 48 INCHES OR MORE SHALL HAVE A TOP OPENING WITH A MINIMUM OF 20 INCHES. ' T ;:GASMETER GARA y O.�.c •..:. ELECTRICAL �p' c ... METER coLi 4. TANKS SHALL HAVE INLET AND OUTLET BAFFLES, SANITARY TEES OR OTHER DEVICES TO PREVENT THE PASSAGE OF _ �: . :•:` SEPTIC SYSTEM DESIGN INFORMATION FLOATING SOLIDS AND TO MINIMIZE DISTURBANCE OF SETTLED SLUDGE AND FLOATING SCUM BY SEWAGE ENTERING AND c `y : LEAVING THE TANK. DRIVEWAY . . :•.`.....:.:.. '. SOIL TEST DATA: ALL FEDERAL,STATE,AND LOCAL CODES AND 5. THERE SHALL BE A MINIMUM OF ONE INCH CLEARANCE BETWEEN THE UNDERSIDE OF THE TOP OF THE TANK AND THE TOP O ' .' REGULATIONS SHALL BE CONSIDERED TO BE PART OF ALL BAFFLES, PARTITION AND/OR TEES. - ..� � . . � .• ' ' .' ' .� OF THE BUILDING DETAILS AND SPECIFICATIONS PERCOLATION TEST: HEREIN.IF DISCREPANCIES BETWEEN THE CODES 6. TANKS SHALL BE PLACED ON AT LEAST A SIX INCH BED OF SAND OR PEA GRAVEL. W • '' '''' ��"�� AND REGULATIONS AND THE INFORMATION 7. THERE SHALL BE A MINIMUM DROP IN ELEVATION OF TWO INCHES BETWEEN THE INVERTS OF THE INLET AND OUTLET PIPES. �' �� CONTAINED ON THESE PLANS EXIST,THE MORE OE• �,�� PT# 1 TRIAL 1: 1:05 PER INCH STRINGENT SHALL APPLY UNLESS THE INFORMATION 8. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 POUNDS PER SQUARE INCH(PSI)AT 28 DAYS SET. I ;': '' t TRIAL 2: 1:08 PER INCH SHOWN,DESCRIBED,APPLY IMPLIED IS A VIOLATION 9. WALL THICKNESS SHALL BE A MINIMUM OF THREE INCHES UNLESS THE DESIGN HAS BEEN CERTIFIED BY A NEW YORK W 105 OF THE CODE,IN WHICH CASE THE CODE OR LICENSED PROFESSIONAL ENGINEER AS COMPLYING WITH ALL APPROPRIATE REQUIREMENTS FOR THIN-WALL � �� EXISTING WOODEN TRIAL 3: 1:10 PER INCH REGULATION SHALL TAKE PREFERENCE OVER PLANS. CONSTRUCTION. ALL WALLS, BOTTOM AND TOP SHALL CONTAIN REINFORCING TO ASSURE SUPPORT FOR 300 PSF. / �� FENCELINE w evidence of, TRIAL 4: 1:12 PER INCH 10. ALL JOINTS SHALL BE SEALED SUCH THAT THE TANK IS WATERTIGHT.JOINTS BELOW THE LIQUID LEVEL MUST BE TESTED ` lJ� 8'3" FROM GRADEOH ELECTRIC "I have seen or observed,Or ���$V8`�encess, etc. TRIAL 5: 1:12 PER INCH DIG SAFELY BEFORE YOU DIG such as houses,wells,trees, WAIT THE REQUIRED TIME FOR WATERTIGHTNESS PRIOR TO BACKFILLING. all objectsresent that i have „ COMPLETED ON: SEPTEMBER 9,2009 BY: VISION ENGINEERING, LLC CONFIRM UTILITY RESPONSE 11. TANK SIZED FOR 2-BEDROOM HOUSE WITH NO GARBAGE GRINDER shown on this document. I also rep di dram. RESPECT THE MARKERS efSOnallY easured the dista t;5 Set fcrth on t Q DEEP TEST HOLES: -DIG WITH CARE p SAFE DIGGING IS EVERYONES RESPONSIBILITY! AT[ DEPTH: TYPE: PLEASE CALL 1-800-962-7962 BEFORE YOU DIG. 8'-8-1/2° ATE VISIT www.digsafeynewyork.com FOR ADDITIONAL SIGN TH#1 0-12" TOPSOIL INFORMATION. 10 0 5 1 40 12-42" ORANGE BROWN LOAMY FINE SAND IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 7" PROPOSED SITE PLAN 42-60" BROWN MED SAND 2 OF THE NEW YORK STATE EDUCATION LAW _______________________ 1 INCH = 10 FEET FOR ANY PERSON,UNLESS ACTING UNDER THE NO BEDROCK OR MOTTLING OBSERVED IN FEET DIRECTION OF A LICENSED PROFESSIONAL ( ) ENGINEER,TO ALTER THIS DOCUMENT IN ANY 1 INCH = 10 FT. WAY.IF AN ITEM BEARING THE SEAL OF AN COMPLETED ON: 9/17/09 BY: VISION ENGINEERING, LLC ENGINEER IS ALTERED,THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE 20"DIA. OR SQUARE COVER I A NOTATION"ALTERED BY"FOLLOWED BY HIS SIGNATURE,THE DATE OF SUCH ALTERATION, SEPTIC SYSTEM DATA: AND A SPECIFIC DESCRIPTION OF THE ALTERATION. FINISHED GRADE _ _ _ III-III-III-III-III-III-III= NO. OF BEDROOMS: 2 BEDROOMS / -III=� -� I-I I=I I=I I=� I=I I I=III=III=III=III=III=III-' TYPE OF SYSTEM: ELJEN GEOTEXTILE SAND FILTER 6-1/2"INLET END I I _ 1I I '! I OUTLET END III III III- III I III-i � �-III=1 I I=1 I I-� � �-' ' NO. GALS. PER BEDROOM: 130 GAL/BEDROOM 20" DIA. OR SQUARE COVER `� �� MAP REFERENCES: DESIGN FLOW RATE: 260 GPD 4 RISER AS REQUIRED MINIMUM SEPTIC TANK CAPACITY: 1000 GAL. ( ( 1. WARREN COUNTY TAX MAPPING AND GIS DATA 2. FIELD MEASUREMENTS CONDUCTED BY DESIGN PERCOLATION RATE: 1-5 MINAN. "HIGH DENSITY POLYETHYLENE I 45o BEND VISION ENGINEERING , LLC GSF APPLICATION RATE: (ELJEN) 1.72 GPD/SQ. FT. PIPE SEALS AT ALL CONNECTIONS I LEACHING SQFT REQUIRED: 151 SQ. FT. EFFECTIVE LEACHING AREA PER LIN FT: 6 SQ. FT./LF L _______________________J 4��wYE THIS PL[P , `:-� SIN NUMBER ELJEN MODULES REQUIRED: 6.3 UNITS ENGINEERS S MP: TO SEPTIC TANK FROM HOUSE PRO - SITE T NUMBER ELJEN UNITS PROPOSED: 7 UNITS Nk t (DIMENSIONS SHOWN BASED ON FORT MILLER TANK) �L T95 �� o EL W R 4yop TOP VIEW TOWN OF QUEENSBURY BUL�INQ DEPARTMENT THE aO OF r.' NOTE: INSTALL EXTERIOR CLEANOUT AT ALL BENDS IN HOUSE SEWER TO SEPTIC TANK IF THE ST IG DI�AWIN TIN BLUE Based Based on Our limited examination, INK,THIS UMENTS Y ILLEGAL C !° COPY OR A E OF GINAL UMENTS `;( a, „ Compliance With our comments Shall NOT CONTAINI IGNA LD NOT BE .CLEAN-OUT DETAIL not be construed as indicating the - USED TO IL DIN UCTION. laps and � P Specifications are In full �' Compliance with the Bullding Codes of / NOT TO SCALE GROUND SURFACE LOCATION MARKER New York State. _ =I _ _ _ _ __= I I=I II II ELJEN IN-DRAIN SYSTEM NOTES: 1 El�I=I�1=111:I I I I11,1 ,;,I I I": I„I�I I�I I�I I�I I�I,;,I�1=1 I I_ I I I,� 1 lf:tl�1f:1�I„]I I„I I�1I�i I I I�I I�1=1 I�� 1. A MINIMUM OF FOUR FEET OF USEABLE SOIL SHALL EXIST ABOVE BEDROCK AND GROUNDWATER WITH A -II�I�II�I=III III_ Z J 12 t COVER !I I 4"DIA. PERFORATED PIPE 5'-O" MINIMUM SEPARATION OF TWO FEET TO THE LOWEST PART OF THE SYSTEM. DANIEL W.RYAN,P.E.-LICENSE#NYS 079060 COVER U 4"TOPSOIL, SEED,AND MULCH 2. ABSORPTION SYSTEM SHALL NOT BE BUILT UNDER DRIVEWAYS, PARTS OF BUILDINGS OR UNDER . • �. '• . .... . 4'-0" FIELD AND ALL SURROUNDING ABOVE-GROUND SWIMMING POOLS OR OTHER AREAS SUBJECT TO HEAVY LOADING. SURFACE WATERS SHALL REVISIONS •' ,, e GEOTEXTILE FABRIC COVER DISTURBED AREAS IMMEDIATELY BE DIVERTED FROM THE VICINITY OF THE SYSTEM. 6 4"SDR-35 INLET • Z 3. ADJACENT PIPES OR LATERALS SHALL BE SEPARATED BY AT LEAST 5 FEET. INDIVIDUAL PIPES SHALL BE (SLOPE 1/4"PER FT.) 4"SDR-35 OUTLET ELJEN MODULE SLOPE SLOPE INSTALLED PARALLEL TO THE GROUND CONTOURS WITH SYSTEM BOTTOM AS NEAR LEVEL AS POSSIBLE. 5 _______ LIQ_U_1_D________ �' 4. PERFORATED DISTRIBUTOR PIPE SHALL BE USED. SOLID(NON-PERFORATED)PIPE SHALL BE USED BETWEEN --- - CLEAN GRANULAR BACKFILL LEVEL - _ _- - _ -= THE DISTRIBUTION BOX AND THE SYSTEM. PERFORATED PIPE SHALL BE MADE OF RIGID OR CORRUGATED 4 z ' (SLOPE 1/8"PER FT. DEVOID OF ROCKS LARGER - - - - - INV. OF INLET ) - - = PLASTIC AND BE LABELED AS FULLY MEETING ASTM STANDARDS FOR USE IN SEPTIC SYSTEMS. CORRUGATED 3 1 THAN 3 INCHES - - - PLASTIC PIPE DELIVERED IN COILS IS NOT PERMITTED. w 2"MIN.ABOVE _ - _P - _= Z INV. OF OUTLET a - __ _ - = III- - _= 5. THE SYSTEM LOCATION AND DEPTH SHOULD BE MARKED BY STAKES BEFORE EXCAVATED. THE SYSTEM DEPTH 2 SANITARY TEE w EFFLUENT FILTER - _ - - -I - _ - SHALL BE AS SHALLOW AS POSSIBLE, BUT NOT LESS THAN 13 INCHES. AT LEAST SIX INCHES OF SAND IS PLACED W _ BELOW THE ELJEN IN-DRAIN. THE EARTH COVER OVER THE SAND SHOULD NOT EXCEED 12 INCHES IN ORDER TO 1 Z o TO BE INSTALLEDo ZABEL OR EQUAL 7�� _ ':: ;: I IL ENHANCE NATURAL AERATION AND NITROGEN UPTAKE BY PLANT LIFE. THE SYSTEM SHALL BE EXCAVATED T > ., :. 0 5-2 � ...�• ; 4'-9" d I I s•.:' - DESIGN DEPTH WITH BOTTOM PRACTICALLY LEVEL. HEAVY EQUIPMENT SHALL BE KEPT AWAY FROM THE FIELD SCALE: AS NOTED DIVERT RUNOFF FROM V _ WASHED CONCRETE SAND BECAUSE THE WEIGHT MAY PERMANENTLY ALTER SOIL CHARACTERISTICS DUE TO COMPACTION CAUSE W 0 2'BAFFLES MAY BE UP SLOPE DRAINAGE _ _ _ _ _ =r =I ASTM C33<10%PASSING#100 SIEVE SIDEWALL CAVE-INS,AND/OR MISALIGN AND BREAK PIPE. DATE: 9/21/09 z v AREAS EACH SIDE I I III III=III=III-) I (-III III- AND<3/o PASSING#200 SIEVE. Z USED INSTEAD OF 6. THE SYSTEM BOTTOM SHALL BE RAKED AND IMMEDIATELY COVERED WITH AT LEAST SIX INCHES OF SAND. ANY ° SANITARY TEE PRECAST SEPTIC SMEARED SURFACES ON THE TRENCH SIDEWALLS ARE TO BE RAKED. DRAWN BY: VISION W TANK 7. THE PIPE SHALL BE CAREFULLY SLOPED AT BETWEEN 1/16 INCH AND 1/32 INCH PER FOOT. 8. GEOTEXTILE FABRIC IS TO BE INSTALLED OVER ENTIRE SYSTEM AREA. PROJECT: 9. PREPARE THE SITE ACCORDING TO STATE AND LOCAL REGULATIONS. DO NOT INSTALL SYSTEM ON FROZEN OR w 2'-0" MIN.ABOVE GROUNDWATER OR SATURATED GROUND. °x w GROUNDWATER OR IMPERVIOUS JOHN CENTER IMPERVIOUS 10. SCARIFY RECEIVING LAYER TO ELIMINATE SMEARING. F 3'-0" 11. ADD 6"LAYER OF WASHED SAND,WITH NO MORETHAN 5% PASSING A#200 SIEVE AND 10% PASSING A#100 SIEVE. 32 OHIO AVENUE ° _w� 12. AVOIDING FOOTPRINTS, PLACE IN-DRAINS WITH PAINTED STRIPE FACING UP, END-TO-END ON SAND IN TRENCH. o 13. CENTER 4"PERFORATED DISTRIBUTION PIPE LENGTHWISE OVER IN-DRAINS. USE SOLID PIPE OVER COMPACTED DRAWING TITLE � a _-_-_- - SAND FROM DISTRIBUTION BOX TO IN-DRAINS. w PE TO N-DRAIN UNIT, USING ONE ELJEN WIRE CLAMP PER IN-DRAIN UNIT. ci GRAVEL BED COMPACTED - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14 STRAIGHT. SECURE IDOWNITHOUGH CORE, FORCING THROUGH FABRIC INTO UNDERLYING SAND PUSH CLAMP ENDS REPLACEMENT SEPTIC o (NOT REQ'D. IN SANDY WELL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15. SPREAD ELJEN COVER FABRIC LENGTHWISE OVER PIPE AND DRAPE OVER SIDES OF IN-DRAINS. SECURE IN PLAN w r a o, SECTION VIEW DRAINED SOILS) PLACE WITH HAND-SHOVELED SAND USING CAU110N TO AVOID BLOCKING HOLES IN PERFORATED PIPE v W 16. PLACE MEDIUM TO COARSE SAND 6'(MINIMUM)Ar THE SIDES IN TRENCH (12" IN BED CONFIGURATION). m o 17. COMPLETE BACKFILL AND LOAM TO 12'(MINIMUM OVER PIPE. FILL SHOULD BE CLEAN, POROUS,AND DEVOID OF DRAWING NO. z LARGE ROCKS 1000 GALLON SEPTIC TANK DETAIL ELJEN IN-DRAIN STANDARD ABSORPTION SYSTEM 18 DIVERT RUNOFF. FINISH GRADE TO PREVENT SURFACE PONDING. SEED LOAM,AND PROTECT FROM N o CIA NOT TO SCALE DWG C=1 co Z 0 NOT TO SCALE g= 1 6y C o_� O f 1 w oa F U