2009-559 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
(zt Community Development- Building &Codes (518) 761.8256
I F 1 4.'TE OF 0CCUP- -AZ-T(]Y
Penn it Number. P20090559 Late Issued: Monday, March 01, 2010
This is to certify that work requested to be done as shown by Permit Number P20090559
has been completed.
Location. 34 TWICWOOD Ln
Tax Map Number. 523400-296-009-0001-033-000-0000
Owner. JAMES & LESLEY CONWAY
I
Applicant: 3AMES & LESLEY CONWAY
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DUES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20090559 Application Number. A20090559
Tax Map No: 523400-296-009-0001-033-000-0000
Permission is hereby granted to: ,TAMES &LESLEY CONWAY
For property located at: 34 TWICWOOD Ln
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JAMES &LESLEY CONWAY Residential Addition $35,000.00
34 TWICWOOD Ln Total Value $35,000.00
QUEENSBURY,NY 12804
Contractor or Builders Name/Address Electrical Inspection Agency
Plans &Specifications
2009-559
520 sq ft resideintial addition
PERMIT FEE PAID- THIS PERMIT EXPIRES:
Saturday,December 04,201V
(If a7onger period is required,an application for an extension must be metre to the code Enforcement Officer
of die Town of Queensbury before the expiration date.)
Dated at the T Queers urt, F ,December 04,2009
s!y
SIGNED BY w n for the Town of Queensbury.
Director of Building&Code Enforcement
_ c)rrlcr tlsrc,Nl v
J
TAX MAP 1 3 TAX NO
2009
FEES PERMIL---- 10-CP1 AI1()r,J 1 rd1 IrN 1 !'IIlr'• l (1 1 ry `"
(If a1+I)IIrrih1n)
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUA CE++OF A VAAt.I,D PERMIT FOR CONSTRUCTIO-�N..' Q _
APPLICANT/BUILDER: tA1I t Wfl t�idy) OWNER:11 I h1 L� ���e L-C7rl W4.
ADDRESS:5+ �Q� 1`dCi !'+F ADDRESS � 1 i c oxod /�..&h el �•I'S
PHONE NOS. [ g'033 F --P�H-�ONE NOS. /61 V 7�a
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 1 0VK 1 rgC-kf-PHONE:OZoZ�I' 0p 7
LOCATION OF PROPERTY: `t _71A) I CW O0 k-a h
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMFNTS AS REQUIRED BELOW
CHECK ALL THAT z
APPLY TO YOUR z p C3 Ct w r;
PROJECT p 00 1= a o z z
w �„ LLLL u1 Q v.p
U
Q Ill o -" c1 z c7 1_ o1 w
z <[ Q U) N O LL I LL a 2 of
SINGLE FAMILY X I LO O rl O �6
TWO-FAMILY p�
MULTI-FAMILY(NO.�
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
jf1t1'11 f�� `)NlV'ltti111J1"1/ l 1111111111111/IJ I rl't'1'1r''•11N'II/ r )'�/r i' 1 ;n/ r 11, 1 11lr'r'r; J,711I/
' ! „rfl
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST:V5/ D D D FUEL TYPE.
HEAT TYPE? h 0+IJ 44'eF>HOW MANY FIREPLACE(S) AND/OR,WOODSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE? nn
PROPOSED USE OF BUILDING OR ADDITION: r6LMI l 1 y IOo M }s Poo r, W6LIkin C/ose.f- 2'na( Float
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?
ARE THERE EASEMENTS ON PROPERTY?
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
1 acknowledge no construction activities shall be commenced prior to issuance of a valid permit. i
certify that the application, plans, and supporting materials are a true and complete
statement/description of the work proposed, that all work will be performed in accordance with the
NY State Building Codes, local building laws and ordinances, and in conformance with local zoning
regulations. I acknowledge that prior to occupying the facilities proposed, i or my agents will obtain
a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by
a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of
occupancy.
I have read a,q agree to the above.
Signed
("
Director of Building & Codes. 761-8256 (for questions QUESTIONS? CALL 761-8256 OR EMAIL
regarding Building Permits, construr,lion code-, or septic_. /' code_s treenshurv.net
systems) t
VISIT OUR WESSITE FOR MORE INFORMATION
Zoning Administrator: 761 821£3 (for questions regarding www.c#ueensbu,ry.net
required permits, the permit process, application requiremenl^ r)l I()
schedule an appointment)
.____- . . . . . . ;
This application/proposed action described Permission is hereby granted to the above
herein is found to be in accordance with the ; Applicant to erect or alter the building described
zoning Laws of the Town of Queensbury. herein in accordance with said Application:
ZONING APPROVAL DATE - BUILDING &CODES APPROVAL DATE
1,011,11 of l< I(rclfSlrifI if - ( (1111nof111111 I !rr•r•/0/MJ4'11l f !f(h I I`oit l , ,rrl 1I11T)r .l1111 y
OP T l
CONSTRUC JOB_(soint j u /
A Div.Of O'V CO SHEET NO. 3!j 7Lw e-LA)Oo d L N OF
/7lGrecFtt Management Corp. CALCULATED BY--#6 A DATE
51 CROWLEY ROAD/HUDSON FALLS,NY 12839
(518)798-0338 FAX:(518)798-0338 CHECKED BY DATE
SCALE -- Z0t
r"OKWO A$a-w evidence of,
1°a�s;cells;:gees, fences,etc.,
1p
I �
- � o
f
i�1 �
47
1101
+ i c w o o-D R
� 20 � i
Queensbury Building & Code Enforcement - Residenti;�ii W Inspection
"�frtce
No. (518)761-8256 Arrive: am/pmDepart: /pme Inspection request received: inspector's initials:
NAME: PERMIT#:
LOCATION: DATE: Z—
TYPE OF STRUCTURE: -
Comments:
N a
4' Building Number Address visible from road
Chimney Height/"B'Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors _
Handrail 4 or more risers
Guards at stairs decks tios more than 30 inches above Weds
Guard at stairwell at 34 inches or more
Guard at deck pqLches 36 inches or more
Handrail Termination at Newell Post or Wall
interior/Extedor Railin s 34 inches to 38 inches
Deck Bracing I Handicapped Ramp Compliant
Grade TM from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off gg2sed/re ulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety lain /Window in stairwells 9jeA glazing
Interior Smoke Detectors/Qarbon Mo oxide Detectors
Every levee: EveryBedroom:
Outside every bedroom area:
Inter Connected: Battey backup: .�
Attic access 30 inches x 22 inches x 30 inches(Wight)in accessible area
Crawl Spaces 18 inch x 24 inch access 1 scl.ft:150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/insulation Certification `
Floor truss,draft stopping finished basement 1,000 N.ft. ,
------------
Emtrgency egress below grade
Gas Fumace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler '
Relief Valves installed/Heat Ira Water Temp 110
Enclosed Stairs Sheetroc k Underside minimum W Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing I%hour fire door/door closer
Duct work Seated
Gas Loge in Seated or Glass Enclosure
Final Electrical
Final Survey Plot Plan �
Are Fault Breaker in Bedrooms
Flex Gas P'De Bonding
As Built S is System/Sewer Dept. Inspection Sticker
L@ood—Plain
Plan i Variance_.required
Certification,if re aired �,.,^to issue C/C or C 10 Tem ora /Parma nent
L:tBuilding&Codes FormslSuilding&CodeMinspection FonnsWesidential Final Inspection Form revised 1
January 7,2008;Revised 6/26/OS06.do Rgyig�
^` _A,
144 Queensbury Building & Code Enforcement - Resl enti final inspection
Qffte No. 518 761-8256 Arrive: am/pm, part.: --�m/pm
Date Inspection request received: Inspector's Initials:
NAME: PERMIT#: _
LOCATION: J 7 DATE:
TYPE OF STRUCTURE:
Comments:
Y N /
,V Building Number Address visible from road
Chimney Height/"B°Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbina Vent through roof minimum 6 inches
Roof Co fete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs decks ios more than 30 inches above grade
Guard at staiiwelf at 34 inches or more
Guard at deck,p2rches 36 Inches or more
Handrail Termination at Newell Post or Wall
interior/Exterior Railings 34 inches to 38 inches
Deck Bradn /Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/r ulator 18 inches above grade
Interior priM i trim/doors/main entrance 36 inches
Bathroom I Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches hei ht in accessible area
Crawl Spaces 18 inch x 24 inch access 1 N.ft.-150 .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft eta ing finished basement 1,000 sq.ft.
Emerg9M egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap!Water Temp 110
Enclosed Stairs Sheetrodk Underside minimum W Gypsum
Basement stairs dosed rise>4 inches
Gar a Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct worts Sealed properly
Gas Logo in Seated or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gie-Ape Bonding
As Built Seoic,system/Sewer-Dept,Inspection Sticker
Site Plan /Variance re wired
Flood Plain Certification,if re uired
Oka to issue C I C or C 10 1 Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\lnspectian Fam Wesidential Final Inspection Fom� revised 9 dos;Revised
January 7,2008;Revised 6/2&W 00�,
-3
Rough Plumbing / tneuiatio Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart:Aamipm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT #:
LOCATION: INSPECT ON: ~' —
TYPE OF STRUCTURE: 7
Y N NIA
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 %inch minimum Drain Size
Washi Machine Drain 2 inch minimum
Cleanout every 100 feet/chan a of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Wa ly Piping
Head
0 .S.I for 5 minutes
Insulation! idential Check/Commercial Check
jyvek or ilar Exterior Sealant
r ent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated Eppaces
Combustion Air Su for Furnace
uct work sealed pr ed I No duct to
NTS.
r
faougn Numbing rnsu&m0"Repr�'Crrevmd Akw 172003, jvvaJd 155�200,
�'' Y tea'�tar�►1��
Framing / Firestopping Inspection Report
ice No. (518)761-8256 Date inspection request received:
lueensbury Building&Code Enforcement Arrive:am/pm . rt: I am/pm
42 Bay Road, Queensbury, NY 12804 Inspector's lnitial
DAME: r0K LA I PERMIT#:
_OCATION: O INSPECT ON:
TYPE OF STRUCTURE:
Y ,f A COMMENTS:
Framing
Attic s 22" x 30" minimum _
Jack Studs/Headers ` �-
Bracing/Bridging +✓ _ <- ,r
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly
127 O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nags each side
Draft stopping 1,000 sq. ft floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in 2@vq min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceilingtwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
L:13uHdbV&Codes Foffns.=iBui hV&Codesunapection FOM'Ftarrdrp FkssWppkV Inspection R"NUac R,ybW JO"70 2008
Framing / Firestopping lns Report
Mice No. (518)761-8256 Date inspection request received:
tusenstwry Building&Code Enforcement Arrive: amlpm Depart:/j am/pm
'42 Bay Road, Queensbury, NY 12804 Inspector's initials:
VAME: PERMIT#:
LOCATION: INSPECT ON: Z-
TYPE OF STRUCTURE: f A4)f
Framing Y N NtA CQMMENTS,.
Attic Access 22'x 3W minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed property
12'O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %Uw 16 gauge 8 16D naffs each We
Draft stopping 1,000 sq. ft, floor trusses
Bolts ft. or less on center
lee and water s ield 24 inches from wall
` e se n 1, 2,3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 Inch insulation in ca &min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
C!!9 It
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf greds
L:113ugdbv&Codes Forms-oLD\w ft&codesu apec&m Fomi0WMVft Fkastoppft ln$WxUon Repa da,V �.
�rRON (TUE)NOV 10 ZOOS 8:UO/ST. 8:ISOZM .760000OZ88 P 1
REScheck Software Version 4.2.2
Compliance Certificate
Energy Code: 2007 New York Energy Conservation
Construction Code
Location: Warren County,New York
Construction Type: Detached 1 or 2 Family
Heating Type: Non-Electric
Glazing Area Percentage: 7%
Heating Degree Days: 7635
Construction Site: Owner/Agent: DesignedContractor:
Compliance:19.6%Better Than Code Ma)dmum UA:92 Your UA:74
Gros- C_Ivity cont Glazing UA
Ceiling 1:Flat Ceiling or Scissor Truss 368 38.0 0.0 1 f
Wait 1:Wood Frame, 16'o.c. 5" 21.0 010 30
Window 1:Wood Frame:Double Pane with Low-E 39 0.310 12
Door 1:Solid 20 0.180 4
Floor 1:All-Wood JoisftT'russ:Over Unconditioned Space 368 19.0 0.0 17
Furnace 1:Forced Hot Air 78 AFUE
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted
with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction
Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her
knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code.
ifEyrw HAKE rs &Av
Name-Name-Titles Signature Date
�{{+ l.� `•to ;�«� t =a
06
Project Title: Report date: 11/06/09
Data filename:CAProgram FIeakCheddRESchecktconway.rck Page 1 of 4
fFROM (TUS>NOV 10 2008 8:SOfST. 9:UOZHo.71500000298 P 2
REScheck Software Version 4.2.2
Inspection Checklist
Ceilings:
❑Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame,16"o.c..R-21.0 cavity insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.319
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes_No
Comments:
Doors:
❑ Door 1:SoNd,U-factor:0.180
Comments:
Floors:
❑ Floor 1:All-Wood JoistJTruss:Over Unconditioned Space,R-19.0 cavity insulation
Comments:
Heating and Cooling Equipment:
❑ Furnace 1:Forced Hot Air:78 AFUE or higher
Make and Model Number.
Air Leakage:
Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials.If non-IC rated,fixtures are installed with a 3"clearance from Insulation.
Vapor Retarder:
❑ Installed on the warm-In-winter side of all non-vented framed ceilings,walls,and floors,
Materials Identification and Installation:
❑ Materials and equipment are installed in accordance with the manufadurWs installation instructions.
Materials and equipment are identified so that oompliarwe can be determined.
❑ Manufacturer manuals for all Installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications.
Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner
that achieves the rated R-value without compressing the insulation.
Duct Insulation:
Duds In unconditioned spaces or outside the building are insulated to at least R-8.
Duds in floor trusses above unconditioned spaces or above the outdoors are Insulated to at least R-6.
Duct Construction:
AN joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or
tapes.Tapes and mastics are rated UL 181 A or UL 181 B.
Exceptions:
Project Tile: Report date: 11/06/09
Data filename:C:Wrogram FileMChecklRESchecklconway.rck Page 2 of 4
FROM fTUe>MOM 10 2000 8:50/ST. 8:00/Mo.7600000288 P 3
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
D The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone.
Electric Systems:
0 Separate electric meters exist for each dwelling unit.
Fireplaces:
I] Fireplaces are installed with tight filling non-combustible fireplace doors.
• Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Budding Code of New York
State,the Residential Code of New York State or the New York City Btdiding Code,as applicable.
Service Water Heating:
❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
Is part of a circulating system.
0 Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Not Water Systems:
Circulating hot water pipes are insulated to the levels in Table 1.
Heating and Cooling Piping Insulation:
Q HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Swimming Pools:
• AN heated swimming pools have an onioff heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time dock.
w
Project Title: Report date: 11/06/09
Data fileneme:C:Trogram FlleslChecklRESchecklconway.rck Page 3 of 4
-vFROM (TUE)NOV 10 2008 0:51/ST. S.50fNo.7500000295 P 4
Table 1:Minimum Insulation Thickness for Circulating Not Water Pipes
Insulation Thickness In inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
Temperature("F)
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2.Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. Insulation Thickness In Inches by Pipe Sizes
Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Coating Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Project Title: Report date: 11M/09
Data filename:C:1Program FileMCheck1REScheckloonway.rck Page 4 of 4