2004-117 0111104, TOWN OF QUEENSBURY
742 BayRoad, ueensbu NY 12804-5902 (518) 761-8201
dab.
Q rY,
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20040117 Date Issued: Tuesday, March 17, 2009
This is to certify that work requested to be done as shown by Permit Number P20040117
has been completed.
Location: 22 CEDARWOOD Dr
Tax Map Number: 523400-296-009-0002-011-000-0000
Owner: PATRICK & CHRISTINE DEE
Applicant: PATRICK & CHRISTINE DEE
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve therTht v
property owner of the responsibility for compliance with Site Plan, ,� -
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code nforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
Feilb 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
? iy
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20040117 Application Number: A20040117
Tax Map No: 523400-296-009-0002-011-000-0000
Permission is hereby granted to: PATRTCK & CHRISTINE DF,F,
For property located at: 22 CEDARWOOD Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: PATR.ICK& CHRISTINE DEE
22 CEDARWOOD Dr Residential Addition $75,000.00
Total Value $75,000.00
QUEENSBURY, NY 12804
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2004-117
832 SQ FT RESIDENTIAL ADDITION
$99.84 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, March 31, 2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at ; n of Q ensbury; , Wednesday, March 31, 2004
i
SIGNED BY c,.. for the Town of Queensbury.
Director of Building& "ode Enforcement
Building Permit Application
Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761.8256
A permit must be obtained before beginning construction. Permit File No. IA 't
No inspection will be made until applicant has received a Fee Paid
valid building permit. All applicants' spaces on this Rec.Fee Paid/$ ` 1
application must be completed and must appear on the
Reviewed
application form. y:
Applicant: ? lcti. p` Owner:
Address: 2-2 t ` 1t crD 0°�-1VE Address:
) at! 12-6 0(-
Phone#( ) - i a t 3 Phone#( ) REtEIVED
Property Location: Lot Number: '2 , / House Number 2-74 Ce19/ L..) 7 D VP4?. 2 J 2004
Subdivision Name: 'i W r(4 0 0 Tax Map Number: .. s USURY
BUILDING AND CODE
❑ New Building: residence /commercial Estimated Market Value of Construction: $ 7 5j 00 0
Addition: residence/ commercial
O Alteration: residence/ commercial If an Addition,what will use of new addition be?
� C lC PL,°3�
Q No change to exterior size: residence/com'l
l
❑ Other work(describe )
Check Occupancylnformation 1"Floor 2"Floor Other floor Total
Below sq.ft. sq.ft. sq.ft. Square Feet
Single fhmmily dwelling ?, , g 3 7„_
o TwofAmity dwelling
a Townhouse
O Multifamily dwelling
#of its
a Office
O Mercantile
O Manufacturing
O 1 oar detached garage
a 2 car detached garage
0 3 car detached garage
O 1 car attached garage
0 2 car attached garage
>a, 3 car attached garage e 7 E'r 3
❑ Storage building-
commercial
O Storage building-
residential •
o Other
What is the proposed height of the structure 2-6 feet .4- inches
Will any second-hand or ungraded lumber be used? If so,for what? N l G �s
Type of Heating System: electric/ oil / gas/wood /forced hot air/aseboar /other: k�.
Number of,Firer.'taces to be installed C) _ Number of Woodstoves to be installed 0
List below the person(s)responsible for supervision of work as regards to building codes:
Name Address Phone Number
Builder PA-1.1 Da L 6 J 1LE `1 '5T- 14 I Z6 3'i '744 -3 57 0
Plumber ez kt‘. L L-i I nl,i r&u ii- or,J`) r
Mason
Electrician
Declaration: please sign below after you have carefully read the statement
To the best of my lrnowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on.the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administrator or Director of. uilding and Codes,an 4s,built Survey by a licensed surveyor;drawn to scale,showing actual
location of all n , onstruc n.
Signature: owner,o er s ag t,architect,contractor
I? ►1 `-`CR 3 3G( -��t
A
a 7
,�l
Pe INum r
7
REScheck Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release lc
Data filename: C:\Documents and Settings\Dan Ryan\My Documents\Temp Files\Dees\rescheck.rck
1'Il'LE:Pat Dee Addition
COUNTY: Warren
STATE:New York \1 .
HDD: 7635 g Li 4--
CONSTRUCTION TYPE:Detached 1 or 2 Family �� '1Z 20)4
HEATING TYPE:Non-Electric
��SBURY C
DATE: 03/23/04 10 U`� G _? ----
DATE OF PLANS: 3/23/04 B
PROJECT INFORMATION:
22 Cedarwood Drive
Twicwood Subdivision
COMPLIANCE:Passes
Maximum UA= 147
Your Home UA= 126
14.3%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 832 38.0 0.0 25
Wall 1: Wood Frame, 16"o.c. 752 19.0 0.0 39
Window 1:Wood Frame:Double Pane with Low-E 60 0.350 21
Window 2: Wood Frame:Double Pane with Low-E 45 0.310 14
Floor I:All-Wood Joist/Truss:Over Unconditioned Space 832 30.0 0.0 27
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and
signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or
specifications are in compliance 'th this Code.
_.(4/____
Builder/Designer 4 • �1.4 _ e t�
`\I,� c' v,4 y (7
® , ,, ,
3�!o. 0 -.06� <�
R�FE S S O�P
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release lc
DATE:03/23/04
TITLE:Pat Dee Addition
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
Above-Grade Walls:
[ ] 1. Wall 1:Wood Frame, 16°'o.c.,R-19.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Wood Frame:Double Pane with Low-E,U-factor: 0.350
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 2. Window 2: Wood Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes [ ]No
Comments:
Floors:
[ ] 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation
Comments:
Air Leakage:
[ I Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
3"clearance from insulation.
Vapor Retarder:
j ] Required on the warm-in-winter side of all non vented framed ceilings,walls,and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
Duct Insulation:
[ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
[ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] Supply ducts in unconditioned spaces must be insulated to R-11.
[ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
s
Duct Construction:
[ ] All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
[ ] Separate electric meters are required for each dwelling unit.
Fireplaces:
[ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State,the Residential Code of New York State or
the New York City Building Code,as applicable.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
I ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
I ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MU ICIPAL CERTIFICATE ELECTRICAL APPROVAL
Permit No. f/ 7 Cert. Nil 7 0 5 4 Cut-in Card No.
Dwner Gam( pzt ul
Location . .. C:c.K2..c./PA-?.fir'.gz..i0Yr P—I
Installation Consisting of A I .t2.i.1.'17" (A I(1.I n Cr— `,2 -7 (2-
Installed By 0, .c:.(.-.S.I. Lie.No.
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making inspections at any time, and if its
rules are violated,the Company shall have the right to revoke this certificate.
Date ) _ 1 `® 1 INSPECTOR
Member N.F.P.A.,I.A.E.I.
Final Inspection
Date Inspection requ 7streceived. Inspector's Initials:
NAME: PERMIT
LOCATION: DATE:
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 8inches
Roof Complete/Exterior Finish Complete
Platform at all -
Handrail 4- -- -above grade
Guards�o��gm� pa
tios �mn �munm�e amu�g�de
Guard at stairwell at34 inches ormore
Guard at deck,porches 36 inches or more
.....~....Termination-�Newell Post or .._ll
Interior/Exterior Railings 34 inches to3Ginches
Deck Bracing/Handicapped Ramp Compliant _
Grade away from foundation D inches with 1Dfeet
, G inch clearance ho sill plate
| 18 inchesb grade
Interior' 'privacy/thm exposed
ntnanoa_36inchea |
, Bathroom/Kitchen watertight
Safety glazing/Window in stairwells s�faty glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every|avm' Every Bedroom:
Outside every bedroom area:
Inter Connected: Battary_�aqkup:
Attic access 30inches x 22 area
SpacesCrawl 18--x 24 inch accessj__.ft.-150 sq.
Bathroom Fans,ifnowindn�/
Plumbing fixtures
Foundation insulation/Insulation Certifinetion
Floor truss,draft stopping finished basement 1.00]sq.ft. .
Emergency egress below grade _
Gas Furnace shut-off within 3O feet or within line mfsite
Oil Furnace shut-off at entrance to furnace area
Fummne/Hcd Water Heater operating
Low water shut-off boiler ----
Relief Valva(w)installed/Heat Trap/Water Temp 11Q
Enclosed Stairs Sheetrock Undersideminimum 1/2'Gypsum
Basement stairs closed ho--4inches
Garage Floor Pitched
Y
- fireproofing/Y4h fired /d closer
ct work Sealed properly
as Logs in Sealed
� '__-_ _l
Final Survey Plot Plan
Arc Fault Breaker inBedrooms -
Flex Gas Pipe Bonding_
Am Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required _
Flood Plain Oe�fi�tion �re�uin�d
'
O��boiooue�/�or�/�[��mpmrory/Pa�amant]
L:\8ui|ding&Codes Fwnne\Bui|dinQ&CmdmsUnopecfionFummoQResidenUo|Final Inspection Fwmrk_rmvimmd_100N}5.dpo;Revised
January 7.2[00; Revised 082GXJ8
Queensbury Building & Code Enforcement - Reside Inspection
Office No. (518) 761-8256 Arrive: :Z_LL.' m/pryrAD p5,ara t: am/pm
Date Inspection request received: Inspect° Initials: S, JP
NAME: hee PERMIT#: / ,
LOCATION: 0 vd. PI „ DATE:
TYPE OF STRUCTURE: _ A /
Comments:
Yes No N/A
4" Building Number Address visible from road Exp 34 daS--
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches 3-771 7-us
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers -- ,
Guards at stairs,decks,patios more than 30 inches above grade r G5 Li /
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
1
/0/6 Ogf764 )(.
Inter Connected: Battery backup: /Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents /1 t/
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum IA"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical V Ake
Final Survey Plot Plan ,
Arc Fault Breaker in Bedrooms C;•1/ /
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C I C or C 10 r Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08
, 1 Queensbury Building & Code Enforcement - Residential Final Inspection
Office No.(518)761-8256 Arrive: am/i6nVetart: mDate Inspection requ received: Inspector's Initials: p
NAME: 11, ;j x ' 1 C`W —i(PLI 3 PERMIT#: c7 =//
LOCATION: AaC i ��� DATE: --
TYPE OF STRUCTURE: - `-
_ Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
i __,3
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6" a,//
Roof Complete/Exterior Finish Complete v
Guard 30 in.or more(a)stairs,decks,patios v
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Zr-
Platform at all exterior doors v
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum %z"
Gypsum
Grade away from foundation 6 in.with 10 ft. .,/
Handrail Termination at Newell Post or Wall ,�``
6 inch clearance to sill plate /1/
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
•
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in. a./;
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing j
Interior Smoke Detectors:
1.///
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup:
Carbon Monoxide Detector //
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched% / Co KCA P (', , /' �t� �j
Garage fireproofing/ hour fire door/door closer ( (� `'J'
Duct work Sealed properly / (✓9 A- �/ I f i, ,hQ K.
Gas Logs in Sealed or Glass Enclosure �
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 sq. ft.-150 sq. ft. vents
Building No./Address visible from road / -�
Final Electrical 1� ° n/14--� �
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C/0 [Temporary/Permanent]
L:\ParnW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: -
Queensbury Building&Code Enforcement Arrive: am/pni Depart:
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT PERMIT#: I
LOCATION: C-eit,NO4scitat> - INSPECT ON: / 0(4
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R-4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
Head or Air Supply Test
Drain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes
Water Supply Piping
Copper Commercial
vi Copper, CPVC,Pex One &Two Family
Insulation/Residential Check/Commercial Check
Proper Vent, Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
LASueHemingway\J3uilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003
-7111--( -3 ._)t)
)9N
Rough Plumbing / Insulation Inspection Report
Office No. 518( ) 761-8256 Date Inspecrion request received:
Queensbury Building&Code Enforcement Arrive: am/ z epart: am/pm 1-)2
742 Bay Road, Queensbury,NY 12804 Inspector's Initials
NAME: C� � PERMIT #:
LOCATION: ("‘ INSPECT ON: '�
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1, R-2,R-3,R-4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 '/ inch min.Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes W' L5 (g
Cleanout every 100 feet/change of direction
Water Supply Piping it)G t)6.0
Co i s er Commercial
oper, CPVC,Pex One and Two-Family
i sulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Fe_ . yes . 160X
OR io S hi RK . .
L:\SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
iq'
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received: A, •
Queensbury Building&Code Enforcement Arrive: am/ epart: 'F am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:
NAME: 9 C-C PERMIT#: -ff
LOCATION: Cc-1jA&ie-ii cre!Tj r2'2 , INSPECT ON: a HO Q
TYPE OF STRUCTURE:
Y N N/A COMMENTS
Framing
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
F're wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Framing /Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: a m part/ `V. am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials
NAME: (\ a, PERMIT#: _--- f 1 I
LOCATION: C., ( � ��U .)0 O INSPECT ON:
TYPE OF STRUCTURE:
Y Nt7 N/A COMMENTS
i,. Framing IJ ��L,t p
Jack Studs/Headers ,J A'-'- SPA- t/Sc'
Bracing/Bridging
Joist hangers Cakyce6t�j /JR� /2Jack Posts/Main Beamsl�
Exterior sheeting nailed properly )�,L., �N6
12"O.C. /t/
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center •
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
/re wall 2, 3,4 hour
Firestopping /e6 Web ve" .1 Ft(I t,s L L
Penetration sealed - /A9Z / 4R ?
16 inch insulation in cavity min.
Garage Fire Separation
4/Critee--House side 3/2inch or 5/8 inch TYPe X ly0/1 p,
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
•
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
A
04/71k
Foundation Inspection Report '7,--
Office No.No. (518)761-8256 Date Inspection request received: z
Queensbury Building&Code Enforcement Arrive: am/prri (1.4,1)..epart/P i am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: (Ni
c -4
..ut?_ '
I
NAME: 0 _.1 , rill rq,te _,6,/ PERMIT#: 01-1 ---8 7
LOCATION: CD'• Cc--.'2f4.1COa-1 C4S.,, INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
,
,
Reinforcement in Place
, Foundation Dampproofing
j
//i/
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 ' ch width
inches above footing
- 6 mil poly for wet 4as under slab
Backfill Approval AtIkkir
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- . _.
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\F3uilding.Codes.inspection.FORMS\Foundation Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:3 Z.. am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: Jt
NAME: - < �Y- PERMIT#: V"4
LOCATION: 10,0 , INSPECT ON: `/j .6/
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Re. orcement in Place
oundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
•
L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection -ques re - szi i l
Queensbury Building&Code Enforcement Arrive: am/p ' Depart: V . •
742 Bay Rd., Queensbury,NY 12804 Inspector's Initia .
NAME: RMIT#: 1.'// 7
LOCATION: c - , INSPECT ON: (e2>ti 4//e -ecaC/
TYPE OF STRUCTURE: S 401' e
e4-4r 850.L) e-,C)—0W 7
Comments
,/e/ 4-7
Y N N/A
(Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
•
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
•
Foundation Dampproofing -�
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.