2008-114
_,tigwQUEURY TOWN OFENSB 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20080114 Date Issued: Monday, September 21, 2009 This is to certify that work requested to be done as shown by Permit Number P20080114 has been completed. Location: 31 AMERICAN Way Tax Map Number: 523400-308-011-0001-057-000-0000 Owner: DANIEL HUNT Applicant: DANIEL HUNT This structure may be occupied as a: Fireplace By Order of Town Board Garage Attached TOWN OF QUEENSBURY Single Family Dwelling ,. Issuance of this Certificate of Occupancy DOES NOT relieve the 6�" property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Coddenfortement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY woo 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080114 Application Number: A20080114 Tax Map No: 523400-308-011-0001-057-000-0000 Permission is hereby granted to: DANIEL HUNT For property located at: AMERICAN Way in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: DANIEL HUNT 21 AMERICAN Way FireplaceGarage Attached QUEENSBURY,NY 12804-0000 Single Family Dwelling $80,000.00 Total Value $80,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2008-114 2327 SQ FT SINGLE FAMILY DWELLING (1590 SQ FT 1ST FLOOR, 737 SQ FT 2ND FLOOR) & 900 SQ FT GARAGE W/ 900 SQ FT ATTIC SPACE ABOVE & 2 FIREPLACES $459.24 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, April 10, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To ueens ry4 , : ,April 10, 2008 ir SIGNED BY for the Town of Queensbury. Director of Building& Code Enforcement � 1ice Fire tl�lczrsTrat`s0f OiL1 itnun of Oleensbitry• 742 B t Rot' • Queer/shin-i Ne c `'Or/. •1;804 r Michael I. Palmer, Fire Marshal•Gary Stillman, T)epitty Fire Mar5/uzi P e £ s APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS Application is hereby made to the Building &Codes Office for the issuance of a Building& Use Permit pursuant to the New York State Fire Prevention &Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances,regulations,and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED. OWNER: y � \\U Ak INSTALLER/BUILDER: C)cw. V ADDRESS: do 11. 1/` Gti, ADDRESS: PHONE NOS. ,SCC)!-)--o1 3 j PHONE NOS. � LOCATION OF PROPERTY: r'�a..CA l/� Ali rk SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: k YV\zH`: CL' A 1.3 CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: "/\ u PHONE: 3(p/(3 S/ ✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL INFORMATION STOVE FIREPLACE INSERT FIREPLACE,FACTORY BUILT* FIREPLACE,MASONRY FURNACE(GARAGE ONLY) *IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. LISTED BY: NUMBER: QUESTIONS? — CALL 761-8205 or 761-8206 CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL: firemarshal[aaqueensbury.net MASONRY'* CHECK ONE ✓ VISIT OUR WEBSITE TILE STEEL SIZE IN FOR MORE INFORMATION INCHES www.queensbury.net FLUE CHECK ONE ✓ DOUBLE CHIMNEY WALL TRIPLE WALL INSULATED DIRECT VENT LINER CHIMNEY MATERIAL CHECK ONE ✓ **IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. _________ It_ Fire Marshal's Office eC l own of Qiifensbary• 742 Bay Bore • Queen-411:1-y \ri'f` "orlk .12804 Michael J. Paltrier, Fire Marshal• Gary Chilli-an, Deputy Fire Marshal 4 A , APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS Application is hereby made to the Building&Codes Office for the issuance of a Building & Use Permit pursuant to the New York State Fire Prevention&Building Code. The applicant or owner agrees to comply with all applicable laws,ordinances,regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE RE UIRED OWNER: -DC\A t1 "` INSTALLER/BUILDER: a✓' ADDRESS: 2-1 ADDRESS: PHONE NOS. . (_O I^ 'II PHONE NOS. LOCATION OF PROPERTY: A. z&v, -)) SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: vy..k.>-t( CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: C\tV C'J"rik PHONE: Z 4-<*7 ✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL INFORMATION STOVE FIREPLACE INSERT IREPLACE,FACTORY BUILT* FIREPLACE,MASONRY +� FURNACE(GARAGE ONLY) *IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. LISTED BY: NUMBER: QUESTIONS? CALL 761-8205 or 761-8206 CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL: firemarshalaqueensbury.net MASONRY** CHECK ONE ✓ VISIT OUR WEBSITE TILE STEEL SIZE IN FOR MORE INFORMATION INCHES www.gueensburv.net FLUE CHECK ONE ✓ DOUBLE - CHIMNEY WALL TRIPLE WALL INSULATED DIRECT VENT LINER CHIMNEY MATERIAL CHECK ONE ✓ **IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION a BUILDING CODE AND/OR MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. r OFFICE USE ONLY TAX MAP NO. PERMIT NO. LJV 1 PERMIT FEE APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT; A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: ,.0tN1^ o ✓a" INSTALLER: "4JC.}.IY1... o' ADDRESS: /"F v1' - C +'1^ L* - ADDRESS: Sa PHONE NOS. 62 f'-—C1 <!1 PHONE NOS. 0 LOCATION OF INSTALLATION: A tro i NO.OF YEAR BUILT ' RESIDENCE INFORMATION: BEDROOMS X r COMPUTATION= _ TOTAL DAILY FLOW GARBAGE GRINDER 1980 or older ; X 150 gallon per bedroom i = INSTALLED? /V) 1981 -1991 X a 130 gallon per bedroom i = SPA OR HOT TUB 1 1992-present , X { 110 gallon per bedroom j = i Li 40 INSTALLED? t PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING V/ STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL YELL (IF WELL:WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. ) ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub. ✓ SEPTIC TANK:477So GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH 62,22 FT. ✓ TOTAL SYSTEM LENGTH: 25O FT. SEEPAGE PIT(S): HOW MANY? ✓ SIZE OF EACH FT. X FT. ✓ SIZE OF STONE TO BE USED: # /DEPTH OR THICKNESS FT. ✓ BED SYSTEM SIZE: X ✓ ALTERNATIVE SYSTEM: LENGTH AND/OR SIZE ✓ HOLDING TANK SYSTEM:(If required) NO. OF TANKS: /SIZE OF EACH ✓ GALLONS./TOTAL CAPACITY: GAL. NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN Il APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based unnn nr h nrnrttnrl in rern,,,,n „��� �� • --j--° //—/ OFFICE USE ONLY IE c I a V E il TAX MAP NO. PERMIT NO. , FEES: PERMIT RECREATION ENGINEERING I ' APR 0 4 2008 (If applicable) .Yc,. .N-OP4,1EENSE3.0 M. ' BUILDING & CODES PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: D co& t `.: i\' - OWNER: DCVY\it-)`1\- ADDRESS: ,\ A y Y'� (,.-CA.,V\ (&)CL,I" ADDRESS: 56 )/vo.. PHONE NOS. (42 J ` -w 6i 3/ PHONE NOS. 4_,,,,,rv._e CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: U& ., PHONE: L ..� LOCATION OF PROPERTY: --ii' .. ,,0t,.-y\_ i. CA SUBDIVISION NAME: I PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT 0 ct Ci w I- APPLY TO YOUR ZO ►= 0 O Cl) a u �-w PROJECT O < O = ~ w � � u"J. � w ¢ CI_ O z < < � d ?vCO OL � ►~i a = o6 SINGLE FAMILY V d i f 2 'TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL GARAGE(11,,2,3) - 67(,JL' ePS Err 41:/// q� t OTHER �w��r��l` gOO VOA IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read id agree to the above. Signed I TI!Fes .. Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: BUILDING & CODES APPROVAL ZONING APPROVAL DATE DATE f QUESTIONS? CALL 761-8256 OR EMAIL codesaqueensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION Office Use Only www.queensbury.net Operating Permit Issued: Yes No check Residential Plan Review: One& Two Family Dwellings Y N/N/A (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 50 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq. ft. Grade, 5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK //, Dampproofing/Waterproofing Materials On Plans V Foundation Drainage On Plans,if required 6"Drop in 10' Exterior Grade / Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where p` Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8' All Stairs 36"Width tair Run and Rise Winder Run and Rise Spiral Not Allowed From 2nd Story Smoke Detectors Battery Backup and Proper Location N7z,r Bathroom Fixtures Proper Clearance Hall Width, 36"min. 47;. Handrails More Than Four Risers On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas rA77-V Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Outside Lowest Sleeping Area,On Every Level& Interconnected Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: 7'.44-6 7 NAME: HUI1,21—• LOCATION:3 PERMIT#: (7T-1 Ki Final Survey Plot Plan Approved Denied . The attached final survey has been received by the Dept.of ✓ Community Development. Upon review the surve ' been: ig Brown,Zoning Administrator Notes: L:\SueHemingway\Building.Codes.lnspection.FORMS\Final Survey Zoning Adminishaxordoc 02..=-emu W 1 Queensbury Building & Code Enforcement - Residenti - spection f • p _ Office No. (518)761-8256 Arrive: �aO8 a � >-s-rt: 7 Ca 30a Date Inspection request received: (1/(1/0 inspector's Initials: l,, lest." NAME: Vh l Pie:• #: 7 —// iti LOCATION: 1 b%v i C i j tom.�i/ 7/t77(Y TYPE OF STRUCTURE: mments: I Li2 N/A 4" Building Number Address visible from roadV/ — yJE i7 T© d..t b'k_ Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake \ 5 V �'0;Z_V--\-> 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete _ g c2tiA V� CI)t'l vW Platform at all exterior doors R t Otl- G�> Y IAA Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade J C�S)E . ' ct t ecce Guard at stairwell at 34 inches or more ,J Guard at deck,porches 36 inches or more / ?-eiA,p‘X-:._k (04\L", Vtect 1 Handrail Termination at Newell Post or Wall ✓/ -To ���� Interior/Exterior Railings 34 inches to 38 inches J Deck Bracing!Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet ✓/ 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy!trim/doors/main entrance 36 inches /1/ Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke D9tictors/Carbon Monoxide,Detectors Every level: ✓ Every Bedoomp ,/ Outside every bedroom area: ✓ Inter Connected: ✓ Battery backup: / Attic access 30 inches x 22 inches x 30 inches(height),in accessible area 7 Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents I Bathroom Fans,if no window I�ti, Plumbing fixtures �C.% Foundation insulation/Insulation Certification / ,4 4z-c,a& Floor truss,draft stopping finished basement 1,000 sq,ft. , �/ �( Emergency egress below grade .i/ Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating / Low water shut-off boiler J �/ Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum"/s"Gypsum Basement stairs closed rise>4 inches f Garage Floor Pitched 7' Garage fireproofing 1%hour fire door/door closer 40 , ,,,./0// Duct work Sealed property Gas Logs in Sealed or Glass Enclosure e"t; FEE Final Electrical „/ t�E 1j �p �jE ,,�i' Final Survey Plot Plan � . ‘F Arc Fault Breaker in Bedrooms '✓ J —2' Flex Gas Pipe Bonding As Built ,. 'c S stem/Sewer De+ . In_pection Sticker 4 /1:// Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary I Permanent] L:\Building&Codes Forms\Building&Codes\{nspection Forms1Residential Final inspection Foram revised 100405.doc;Revised January 7,2008;Revised 6/26/08 9/01 Town of Queeasbury Fire Marshal �� ► 742 Bay Road �— iQueensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Wood Burning Fireplace/Stove inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation Iron the manufacturer's instructions or specifications is allowed. 7 Permit# ll Schedule Inspection 9/747 TimeG J) pm ytime Inspector Name Address 3/ >ller%651/0 it7 Rough In Final Y Appliance Manufacturer Model# � i Masonry Chimney Factory Built ChimneyX Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection 1 Clearances to Combustibles(all sides) 1 Safety Strip Installation(fireplaces only) Firestop(s) Vertical Chase / Wall Penetration Chimney Clearances to Combustibles Chimney Termination 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Combustion Air i Hearth Extension V Mantel(height above Up opening) // '44) I►`�/ Fireplace Doors I Screen(required) 617/4(te9 Wilke—BaiNim Dept. YeSew—Comer Pisic—Fire Marsha' Town of Queend my Fire Marshal 4. 742 Bay Road ��- Queeusbury,NY 12804 "W 761-8205/761-8206 fax 745-4437 Factory Built Wood Burning Fireplace I Stove Inspection Report Notice:New York State requires that aft UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. /� Permit# ( -�j Schedule Inspection rtiLeS Time 'Vam anytime Inspector 4,› same 4..)n-t--- Addrest3l Rough In.or Final Appliance Miumfacturer_/ j/4 Model# I %L Masonry Chimney Factory Built Chimney.( Flue Size Double Wall Triple Wall Insulated Yes '' No N/A Comments Floor Protection Clearances to Combustibles(all sides) Safety Strip Installation(fireplaces only) X I'� �� '-cvA y''7<<isoz Firestop(s) Vertical Chase Wait Penetration ' Chimney Clearances to Combustibles Chimney Termination 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Combustion Air ��� �- (IA/ , SZ-I6 � iLv2 SST Hearth Extension � / Mantel(height above f/p opening) Fireplace Doors/Screen(required) White—Dmilding Dept. Ye& —Cattenter Pink—Fire Marshal T / ,,..,, - -4.,/ peettives Queensbury Building & Code Enforcement - Residential F al inspection Office No. (518)761-8256 Arrive: �= i a. , b pert: = Z asC Date Inspection request received: Inspector's !nits: f NAME: f�tom-- % ' IT#: 1 "��� LOCATION: Aver►ri4...� �a ' ATE: _ � L--67 TYPE OF STRUCTURE: ! 7 ` Comments: ,/fs NA FL co-il l-- 4" Building Number Address visible from road / Chimney Height/"B"Vent/Direct Vent Location ,/Fresh Air Intake J. r1 tU f -d- U 3 inch Plumbing Vent through roof minimum 6 inches ✓/ �rRoof Complete/Exterior Finish Complete ©G\Platform at all exterior doors -Jye /-Handrail 4 or more risers J' Guards at stairs,decks,patios more than 30 inches above grade V' Guard at stairwell at 34 inches or more / Guard at deck,porches 36 inches or more Y /. Handrail Termination at Newell Post or Wall v/L i� 'l �.\ Interior/Exterior Railings 34 inches to 38 inches _ Deck Bracing/Handicapped Ramp Compliant ✓ ' -‘ � C c Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate t/ — \V--\ \ Gas Valve shut-off exposed/regulator 18 inches above grade i Interior privacy 1 trim i doors t main entrance 36 inches c,ii.F L) Bathroom/Kitchen watertight V/ ti o ,� i t4' Safety glazing/Win in stairwells safety gl ing .J �l� © --N. Interior Smoke Det ors/Carbon onoxide etectors ��/ Every level: • Eve Bedy ►. c' . Outside everybedroom a: 4 � Inter Connected: Battery backup: V / Attic access 30 inches x 22 inches x 30 inches(height)in accessible area ✓ G. s.,Lf;` Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sg.ft.vents / Bathroom Fans,if no window ��•/ -----� Plumbing fin V �e — to � ���`�� ` Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade y tr-V-l t \2-c.c.L7 Gas Furnace shut-off within 30 feet or within line of site V Oil Furnace shut-off at entrance to furnace area Fumac e/Hot Water Heater operating . k7 Low water shut-off boilers ,i•k o :ct Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'r4"Gypsum ✓4, '\►•)4 Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer ✓,/ t a��iJF t t.. ‘(�H �a�'� Duct work Sealed properly �,4tbtk b ,.•t r ii Gas Logs in Sealed or Glass Enclosure 7/4 ' H -v tQ c,-V�i Final Electrical Final Survey Plot Plan _ I/ k,A i2stx V %, c \___. 51 Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding / As Built Septic System i Sewer Dept. Inspection Sticker 'V Site Plan /Variance required ,7 Flood Plain Certification,if required /✓ Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 Lit*---- ----- Framing 1 Firestopping Inspection Report Office No. (518)761-8256 Date Ins•- M-o =►- - l d' _ f O -(� QueensburyBuilding &Code Enforcement Arrive: f '�- i',Ow" . - . .rt: '..irliV, 742 Bay Road, Queensbury, NY 12804 Inspector's In 0:,; / .c.14 NAME: 'ERMIT#: 0 8 4 LOCATION: NSPECT ON: 7P7 i TYPE OF STRUCTURE: Cilr9 Y N N/A COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing I Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour /.-------- F'CZ-E. L.C) � L Fire wall 2. 3s 4 hour \ k__et\_E! �nrstoppin . r\ Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Yz inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Building&Codes Forms-QLD\Building&Codesllnspedion FamsTranang Firestopping Inspection Repwtdoc Revised January 7,2008 Cc-10 ctev- Rough Plumbing / Insulation Inspection Rep ,rt� Office No. (518) 761-8256 Date Ins ection r ues ' ed: ( a o e Queensbury Building & Code Enforcement Arrive: z 7 => : �1-x" am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initia s: CDC0---+'. NAME: ,A t&N( PE IT #: (I LOCATION: 0,Net- Loci I INSPECT ON: TYPE OF STRUCTURE: Y N N/A J Rough Plumbing /Nail Plates Plumbing Vent 1 Vents in Place 1 'A inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet I change of direction Pressure Test Drain /Vent Air/Head -- 6� 5 P.S.I. or 10 ft. above hhest connection for 15 minutes oV.A 2--tom Pressure Test -kt•A Rt Water Supply Piping � T Air/Head w " ,. r 15 minutest ' t / Residential Check/Commercial Check -t U'Vt-i*13 - or Similar Exterior Sealant .. ��� Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Phi E� Duct/Hot Water Piping Insulation ScPy �Q If required unheated spaces Combustion Air Supply for Furnace aA'� Duct work sealed properly I No duct tape s _fccv V? — rcAL vp CQS COMMENTS: ‘* tcrJ 1 Qtq - pw isJ <i- 1�C si"`7‘i t 0: V ikN tq C-- � i .V%-7) A LL " Rough Plumbing Insulation Report,revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection r-Oil; .- «�' - . Queensbury Building & Code Enforcement Anive:7, a s -rt: 7d-1). at ?742 Bay Road, Queensbury, NY 12804 Inspector's In�al' _ e NAME: t 7J ,;) PE' MI ' #: --' tl LOCATION: IN E�1 ---V-- S CT ON: 6"? --Zfer-C TYPE OF STRUCTURE: 7-. t lad; . k o Y N N/AJ Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 'A inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test 7ter Supply Piping 'r/Head . . 1 u es -- ul� ' " ential Che /Commercial Check i/ Tyvek or t Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: A IV-Z,b-M-VVIv , k\----N)'Zt •E\-- '''''' (-------- Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspe ion quest received: Queensbury Building & Code Enforcement Arrive: am/pT rt: am/pm 742 Bay Road, Queensbury, NY 12804 Inspe or's Initials: V NAME: v PERMIT #. `- \ (4 LOCATION: w-02- C-JrJJ (\ Iyik INSPECT ON: 9---2'— TYPE OF STRUCTURE: Y N N/A 1 Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction /7 P ssure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check _ Proper Vent, Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace ct work sealed properly/ No d Ape I ) 7 4- t g- -€2 ref /,'4,g/ 7/9--(— COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 2 _ L i 7/ J Rough Plumbing l Insulation lnspec n Report Office No. (518) 761-8256 Date Inspcctioji request received: Queensbury Building &Code Enforcement Arrive: - 1'S am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's initials\g--C-" NAME: /i- t,\-ii.,,,) / j PERMIT #: SN' LOCATION: , /44-er i Cam„ 6 SPECT ON: - --- TYPE OF STRUCTURE: Y N NIA ' ough Plumbi /Nail Plates ',Piumbi ent/Vents in Place 1 Y inch minimum Drain Size Washing Machine Drain 2 inch minimum leanout every 100 feet/change of direction Pressure Test -\x 1-_, - v-5 Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes ressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes /Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Ventif Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape rtie‘-iroe ______ __{ ivir ee-A-et COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 /0— / Z (?Thid-0 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection '- • F ' Queensbury Building &Code Enforcement Arrive: , • /f - V !- • - •: \A.: L 742 Bay Road, Queensbury, NY 12804 Inspecto s Initia - ,r NAME: /1Ut / / PERMIT#: S ' LOCATION: '3/ %i r i t&-` 7 ' INSPECT ON: Mi 'r/l` TYPE OF STRUCTURE: ' 4iii igt - iiiiv6:5 Y N NIA COMMENTS: ' ' PR < iAvA =:,-ss 22" x 30" minimum Jack Studs/Headers Bracing I Bridging Joist hangers Jack Posts I Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more ' p '!*a►< ,�. Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls 11 �E'S) � .:- r' Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side �� 'A Draft stopping 1,000 sq. ft. floor trusses rC Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Fortes-OLD\Building&CodesUnspedion Fortns'Framing Firestopping Inspection Repoitdoc Revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inon - -- - •. Queensbury Building &Code Enforcement Arrive: %6 . v � s rt: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. a L NAME: K v - PERMIT#: D "'fit Lk LOCATION: R MEN 1C1c) pd INSPECT ON: TYPE OF STRUCTURE: NIA COMMENTS: Framing Vetti1/441/34d:7 .-___ Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Building&Codes Forms-OLD'Building&CodeslInspection Fom ssFrarning Firestopping Inspection Report.doc Revised January 7,2008 \4 ( - . r. ti ate- Iiii ,i- ) * '.17 th(i o55! 10k / Septic Inspection Report Office No. (518) 761-8256 Date Ins.- ion r=.- • :cei • Queensbury Building &Code Enforcement Arrive: r = Li D, It: =t<s.',►� rr �r( 742 Bay Rd., Queensbury, NY 12804 Inspector's Ini M NAME: fltdikPE' IT NO.: _ LOCATION: Ai,-1,,o ri. Ca L2 , I .•ECT ON: , RECHECK: / Comments and/or diagram Soil Ty. ,•/1°414 . / Clay Type of Wate •� :•�1* Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + / - Y N N/A Absorption Field: Total length _ 1,•013 -ft. Length of each trench LI 4r 5Q ft. Depth of trenches _ 2 ft. Size of Stone tiWtvTd- 17 Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank t 5 Li-}t-te) Tank to Distribution Box Lk" Q'U Distribution Box to Field Pit 18 i J 1 i 103 c--\\,.c p Opening Sealed: _Y N End Cap yiN Inlet/Outlet Pipes &Baffles Y_ N Location/Separations 0. Foundation to tank t \t-ica ft. Foundation to absorption 1 ft. Separation of Pits _ _ft. Conforms as per Plo an �_ N Engineer Report and -Buil ✓Y N Location of System on Property: Front ar Left Side Right Side Middle Front Middle Rear S U s• Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 L:\Building&Codes Forms-OLD\Building&Codes\Inspection Forms\Septic Inspection Report.doc I s — „`0 I e OHw `4, i 01W v W i if Niagara Mohawk Power a 1 OHW _ 0 1 .- Ai. DG °- it ' IRON PIPE?,t (1988) 1 Water supply to proposed residence to be provided from existing municipal waterisystem. — Lands N/F Candy Clark / T pork;, Tax Map No.: 308.11-1-72 / /'� t-ev i•v. N , t�evnovc - '4.4.0 0 z.) '‘,.) r‘a ..-------— ,07--' ' J f r / +�t,9�(} 'r OV r �z �� ' f� (LU ` � � *� Via- O co LOT NO.3 t �l t rJ' Ii `" a a ' Area: 2.053 Acres+ 1 { &K l Lands N/F Richard&Linda Phillips a' le 0 I Tax Map No.: 308.11-1-73 `� l 9 l 1 238.3‘` I RON PIPE .f, 00 a IRON"•• ` 1(1 938) FOUND "':�- RED PINE WITH WIRE FENCE _. 7.. IRON PIPE (1986 t 1 I Framing / Firestopping Inspection R rt Office No. (518)761-8256 Date In- , --yM'• - request received: Queensbury Building &Code Enforcement Arrive:ew am/ part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspect•is Initials: NAME: //UK PERMIT#: _ r 4. LOCATION: L�r i C : . 1.`,�r INSPECT ON: h —© TYPE OF STRUCTURE: Y N N/A COMMENTS: Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses eh' . or less on center P.O.f 14'--' Ice and water shie 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Building&Codes Forms-OLDDBuilding&CodesMnspedion Form&Framing Firestopping Inspection Reportdoc Revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspecti9 equest received: Queensbury Building&Code Enforcement Arrive. 'N a epart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspecto 's Initials: NAME: t� PERMIT#: _8- k I LOCATION: c4.MCA ti' L 41 INSPECT ON: d 8 TYPE OF STRUCTURE: Y N I N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses u or Bolts 6 ft.or less on center �/ ç?c t\ thi Ice and waters shield 24 inches from wall i i .)Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed _ 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade . Framing I Firestopping Inspection Report Office No. (518)761-8256 Date Inspectign request received: Queensbury Building &Code Enforcement Arrive: I fob am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ''- NAME: Hill I PERMIT#: �9-,iI LOCATION: l .t- ?t c q,.) w' x`. INSPECT ON: C A TYPE OF STRUCTURE: Y N N/A COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate (w) 16 gauge (8) 16D nails each side Distopping 1,000 sq. ft. floor trusses Bolts 6 ft. or less on center nd water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Yz inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Building&Codes Forms-OMBuiiding&CodesUnspection Focroscraming Firestopping Inspection Repoitdoc Revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date Inspection requ-- -�j!'. Queensbury Building&Code Enforcement Arrive: 1 a) �� Depart: \� m 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials/ " NAME: l P: � �T#: LOCATION: "Aker/*CA „� �. 1 ' 'ECT ON: TYPE OF STRUC Comments Y N/A a Footings � Piers Monolithic Slab Reinforcement in Place c‘czjyc�--- The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 - footing /./ 6 mil poly for ,-t areas under slab - . . .val Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM p-12_ 6---;d6L7 Foundation Inspection Report Office No.(518)761-8256 Date Ins. 'o 1 Queensbury Building&Code Enforcement Arrive: A1:. glo . i;!/e.• Depart: 742 Bay Rd.,Queensbury,NY 12804 Inspector's In - :, . - NAME: lb RMIT#: 0 r-/ LOCATION: ,..,e t, CC,L`. .. I..J�J INSPECT ON: , 5 =/ -(,,K. TYPE OF STRUC ' -: Comments rz___ k , 4"(let\-- 1 Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foot' e�Te s-er�Ce in place / Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width ari, 6 inches above footing holy . wet areas under slab .,,',t Cyr mb-mg Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspecction Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspectiouest received: Queensbury Building&Code Enforcement Arrive: 2-'•l 5 am/pm,1 Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: 1 NAME: ) PERMIT#: (� t LOCATION: `(Z�jsc INSPECT ON: `S�i /ôô TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump N 0 Footing Drain Stone: 12 inch width Rff `� 6 inches above footing \ 6 mil poly for wet areas under slab ✓ Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Reportdoc Last printed 12/20/2005 9:24:00 AM , .e�Y/ o /0"7 ( Foundation Inspection Report Office No.(518)761-8256 Date Ins 'tion request received: Queensbury Building&Code Enforcement Arrive: ( am/ m 0 Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector s Initials , NAME: / PERMIT#: LOCATION: /Jt'ii %(r c'o , INSPECT ON: ,/� J2 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place �F-So�czweTs or ay in place f Foundation Dampproofing ' C�C� U i Foundation Wa�erjroofing Footing Drain Daylight or Sump C d.2-0&&., Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Queensbury Building & Code Enforcement - Residential F al ,pection Office No. (518) 761-8256 Arrive: t di I Ord:d: am/ Date Inspection request received: Inspector's Initia .,. NAME: c) P t ::> --.\ C -ER 'iT#: (�C11`-1 LOCATION: 3 k f\Nl '.aC—a r.`'> a'"C D' E: 9 —'�I—09 TYPE OF STRUCTURE: Comments: , ii4' Q SA 4' Building Number Address visible from road V Chimney Height I"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Co fete/Exterior Finish Com ete Platform at all exterior doors _ Handrail 4 or more risers i _� t6's17 Guards at stairs,decks,patios more than 30 inches above rade \ ,`.�� Guard at stairwell at 34 inches or more _, V`�V-.5 Guard at deck,porches 36 inches or more ji Handrail Termination at Newell Post or Wall MNI �interior/Exterior Railings34 inches to 38 inches / Deck Bracing i Handicapped Ramp Compliant L1 Grade away from foundation 6 inches with 10 feet -4i 7pitip 8 inch clearance to sill plate y O� �C0 C Gas Valve shut-off exposed/regulator 18 inches above grade ps Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight 'c't e a Safety glazing/Window in stairwells safety gl- 'l J Interior Smoke Detefors I Carbon Monoxide •=tectors Every level: / Every Bedroon/ Outside every bedroom ea: t/ Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(heiehtl in accessible area , , Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents / Bathroom Fans,if no window 1 Plumbing fixtures 44 NI insulation/insulation Certification Floor truss,draft stopping finished basement 1,000 sq ft. Emergency egress below grade //� i Gas Furnace shut-off within 30 feet or within line of site ,/ - / Oil Furnace shut-off at entrance to furnace area �J Fumac e/Hot Water Heater operating Low water shut-off boiler / Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum1/2"Gypsum / Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/3 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure �/ ✓ Final Electrical i-3' Final Survey Plot Plan _ li i ..___ NA Arc Fault Breaker in Bedrooms '`/ ,--6 Flex Gas Pipe Bonding As Built Septic System I Sewer Dept. Inspection Sticker I [4— Site Plan /Variance required _ / (): Flood Plain Certification,if required Okay to issue C I C or C I 0[Tempora /Permanent L:\Building&Codes Forms1Building&Codes\lnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 Foundation Inspection Report Office No.(518)761-8256 Date Ins ti n nest received: Queensbury Building&Code Enforcement Arrive: pft L Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspecto 's tials: , NAME: IJN( PERMIT#: 08—11 /' LOCATION: ,Z►C 141 A/i9'r INSPECT ON: 0/ ` '6 TYPE OF STRUCTURE: ( < Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Fo ion/Wallpour ,\I info me'in Place Footin, Dowe s or Keyway in place Founda,'on D; i.pproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM - 4jeck...e_sda7 Foundation Inspection Report Office No.(518)761-8256 Date Inspect*request received: Queensbury Building&Code Enforcement Arrive: '5t)am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: OC - // LOCATION: ri`C_Lx.v, INSPECT ON: -64F- TYPE OF STRUC . Comments Y N N/A Footings ....) /7: Piers Monolithic Slab Reinforcement in Place (6/ � The contractor is responsible for providing protection from freezing (7g( for 48 hours following the placement ( 04)1( of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM .1111111111111111Mmomm _ 1 ' 1 - 4.1.-. . I a _- :-' 4.1k -..- ........... ,,,,I 1_ .p rib..Fts zali.," 4 0.4. %Ow.i i p i I a-n ce %,,c1t a. 4.,,ate - - Pto-ieui title: HUN i KL.StliLflUL Report Date:03/24/08 Data filename:CAPrograin FileslCheddRESchecicIHIJNT RESIDENCE.rck Eneroy Code: New York State Enemy Conservation Construction Code Construction Type: Detached I or 2 Fam4 Heating Type: Non-Electric Glazing Area P ritage: 1870 Heating Degree Days: 7635 Construction Site: Owner/Merit Designer/Contractor QUEENSBURY,NY 12804 DANIEL AND JAMIE HUNT DRAWINGS UNLIMITED OWNER QUEENSBURY.NY 12804 QUEENSBURY,NY 12804 '1.*-;,:1:'•-----,7,--,,'--- -.--•=4-1----- --.71-C.,;..Z;-;i1.74-7:„,-;; .x,-ter, -,,=•,-,,-----_-----",,,,,-7-4,-*--77ZW..,:-7,1,--.-- .., ---.77.1-7,,-,------7,77-_------,::17.-7, 7,7--7---- -- Maximum OA-.549 Your Home Wt.479=12.8%Better than Code . - CeWina 1:Cathedral Going(no attic) 84 38.0 0.0 2 Ceiling 2:Cathedral Ceiling(no attic) 84 38.0 0.0 2 Ceiling 3:Cathedral Ceiling(no attic) 84 38.0 0.0 2 Ceiling 4:Cathedral Ceiling(no attic) 84 38.0 0.0 2 Ceiling 5:Cathedral Ceiling(no attic) 84 38.0 0.0 2 Ceiling 6:Cathedral Ceiling(no attic) 84 38.0 0.0 2 Ceiling 7:Cathedral Ceibig(no attic) 396 38.0 0.0 11 Ceiling 8:Cathedral Ceiling(no attic) 2160 38.0 0.0 58 Ceiling 9:Flat Ceiling or Scissor Truss 496 38.0 OM 15 Wall 1:Wood name,16"o.c. 400 21.0 0.0 15 Window 1:Wood Frame:Double Pane with Low-E 15 0.340 5 Window 2:Wood Frame:Double Pane with Low-E 15 0.340 5 Window 3:Wood Frame-Double Pane with Low-E 20 0.340 7 Window 4:Wood Frame:Double Pane with Low-E 20 0.340 7 Window 5:Wood Framellnitbirb Pane with Low-E 20 0 340 7 Window 6:Other 8 0.340 3 Door 1:Solid 32 0.240 8 Waft 2:Wood Frame,16 o.c. 240 21.0 0.0 12 Window 7:Wood Frame:Double Pane with Low-E 15 0.340 5 Window ft:Wood Frame:Double Pane will,Low-E 15 0.340 5 Wall 3:Wood Frame,16"o c 400 21.0 0.0 18 Window 9:Wood Franie:Double Pane with Low-E 15 0.340 5 Window 10:Wood Frame:Double Pane with Low-E 15 0.340 5 Window 11:Wood Frame:Double Pane with Low-E 9 0.340 3 Window 12:Wood Frame:Double Pane with Low-E 9 0.340 3 Door 2:Glass 40 0240 /0 ,-- Wa0 4:Wood Frame,lb-o.c. 24 21.0 0.0 Wall 5:Wood Frame.16"o.c. 24 21.0 0.0 1 Window 13:Wood Frame:Double Pane with Low-E 14 0.340 5 Wall 6:Wood Frame,16'o.c. 208 21.0 0.0 10 Window 14:Wood Frame:Double Pane with Low-E 8 0.340 3 HUNT RESIDENCE Page 1 of 8 "r-..t-w 15:Wrv_vf Finntir o ehie Paris with Low-E 8 0.340 3 Window 16:Wood Frame:Double Pane with Low-E 15 0.340 5 Wall 7:Wood Frame.16"o.c. 80 0.0 0.0 19 Window 17:Wood Frame:Double Pane with Low-E 15 0.340 5 Window 18:Wood Frame:Double Pane with Low-E 15 0.340 5 Window 19:Wood Frame:Double Pane with Lower 8 0.340 3 Wall ilt Wood Frs,rre.16"o.c. 64 21.9 0.0 1 Window 20:Wood Frame:Double Pane with Low-E 44 0.340 15 Wall 9:Wood F sine.16"o.c_ 64 9.0 0.0 5 Window 21:Wood Frame:Double Pane with Low-E 44 0.340 15 Wall 10:Wood Frame,16'O.C. 63 21.0 0.0 4 Wall 11:Wood Fame,16'o.c. 63 21.0 0.0 4 Wan 12:Wood Frame.16'o.c. 63 21.0 0.0 4 Wall 13:Wood Frame,16'o.c. 63 21.0 0.0 4 Wall 14:Wood Frame.16"o.c. 63 21.0 0.0 4 Wall 15:Wood Frame,16"o.c. 63 21.0 0.0 4 Wan 16:Wood Frame,16"o.c_ 240 21.0 0.0 14 Wall 17:Wood Frame,16"o.c. 210 21.0 0.0 10 Window 22:Wood Frame:Double Pane with Low-E 15 0.340 5 Window 23:Wood Frame:Double Pane with Low-E 15 0.340 5 Rasernent Waft 1-Solid CCirAehr or Masonry 'n0 7.0 0.0 22 Wan height 7.8' tenth below trade.-7 IT Insulation depth:4.0' Basement Wall 2:Solid Concrete or Masonry 151 7.0 0.0 16 Wall height 7.8' Death below nradr:-7 tP Insulation depth:4.0' Basement Waft 3:Solid Concrete or Masonry 452 7.0 0.0 44 Wall height 7.8' Denth helrrw node-7.0' Insulation depth:4.0' Floor 1:All-Wood Joistrrruss:Over Unconditioned Sume 990 30.0 0.0 33 Furnace 1:Forced Hot Air90 AFUE The Drowsed txrllkltne represented in this document is consistent with the bulldine plans.soecfications.and other calculations submitted with this penal application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Cede reouirements.When a Recited ion Professional has at,a!Led and sinned this pope,they are attc-,ti,io that to the hest et hisl her knowledge,belief,and profiessiOrlai judgment such plans or specifications are in complance with Ibis Code. Name-Tale A , . , . , PI- (11 4)1,06 HUNT RESIDENCE Page 2 of 8 inspection Checklist Date:03r24/08 Ceilings: Ceifing 1:Cathedral Ceding(no attic),R-38.0 cavity insulation Comments Ceiling 2:Cathedral Ceding(no attic),R-38.0 cavity insulation Comments: Ceding 3:Cathedral Ceding(no attic),R-38.0 cavity insulation Comments: U Ceiling 4:Cathedral Ceding(no attic),R-38.0 cavity insulation Comments: 0 Ceiling 5:Cathedral Ceding(no attic),R-38.0 cavity insulation cc''inmates: CI Caring 6:Cathedral Caring(no attic),R-38.0 cavity insulation Comments: 0 Ceding 7:Cathedral Ceiling(no attic),R-38.0 cavity insulation Comments: 0 Ceiling 8:Cathedral Ceding(no attic),R-38.0 cavity insulation Comments: LI Ceiling 9:Flat Cairn%or Scissor Truss,R-38.0 cavity Motion Comments: Above-Grade Walls: 0 Wain:Wood Frame,16"o.c.,R-21.0 cavity insulation Comments: C3 Wall 2:Wood Frame.16-o.c.,R-21.0 cavity insulation Comments: 0 Wad 3:Wood Frame,16"o_c.,R-21.0 cavity insulation Comments: Wad 4:Wood Frame,16'o.c.,R-21.0 cavity insulation Comments: 0 Wall 5:Wood Frame,16'o.c.,R-21.0 cavity insulation Comments: 0 Wall 6:Wood Frame.16"o.c.,R-21.0 cavity insulation Comments: Wall 7:Wood Frame,16"o.c.,R-0(uninsulated) Comments: 0 Wall 8:Wood Frame.16*o.c.,R-21.0 cavity insulation Comments: 0 Wall 9:Wood Frame,16"o.c.,R-0(uninsulated) Comments: HUNT RESIDENCE Page 3 of 8 IIIMMENts • Fl%titan 411-111leenet 1 1:1-14 esno4y-irretkel-stieve* Comments: rr tys.11 4 4 latleartel Fre,enca 4g.ea ea R-94 n rasaifilaa Cornments: Woit 49-laideseaa gem.. 4g.ea ra R-.94 neataihe ineralaa#6-ae. Comments: %Mewl=reaeeaaat Comments: ri%Atoll it-Wrarai lemmaI5 n n ireenfoilinet Comments: n ws# Wnn't lg" R-91 0 Invilv ins.+Ation Comments: in-Wearart R-91 1E11 lifasa4ranea Convnents: ri Watt 17-lAkylvi.Frey...In".,.- 17,-?1 fi fr4u#V Comments: aaSerrient Walls: 0 Basement Waft 1:Solid Concrete or Masonry,7.8'ht 1 7.0'bg I 4.0'instil.R-7.0 cavity insulation Comments: ta Basement Wall Solid Concrete or Masonry,7.6`ht/ bg/4.0'instil,R-7.0 cavity insulation Comments: 0 Basement Waft 3:Solid Concrete or Masonry,7.8-Id f bg I AL&instil,R-7.0 cavity insulation Comments: VirtndowS: 0 Window 1:Wood Frame:Double Pane with low-E.,U-factor 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: CI Window 2:Wood Frame:Double Pane with Low-E,U-factor 0.340 For windows without labeled U-factors,describe features: #Paies Frame Type Thermal Break? Yes No Comm CI Window 3:Wood Frame:Double Pane with Low-E,LI-factor 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: CI Window 4:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: 'Wanes Frame Type Thermal Break? Yes No Comments: CI Window 5:Wood Frame:Double Pane with Low-E,U-factor 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Window 6:Other,U-factor 0..340 For windows without labeled U-factors,deserts:features: *Panes Frame Type Thermal Break? Yes No HUNT RESIDENCE Page 4 of 8 Comments: 0 Window 7:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: Wanes Frame Type Thermal Break? Yes No Comments: Q Window 8:Wood Frame:Double Pane with Low-E,Udactor:0.340 For windows without labeled U-fa,describe features: #Panes Frame Type TLenfal Break? Yes No ' Comments: Q WCndow 9:Wood Frame:Double Pane with Low-E.U-factor:0.340 For windows without labeled U-factors.describe features: #Panes Frame Type Thermal Break? Yes No Commieaits: Q Window 10:Wood Frame:Double Pane with Low-E U.-factor 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Q Window 11:Wood Frame:Double Pane with t.ow-E.U-factor:0.340 For wriwk,w-.without labeled U-factors,describe feahres: #Panes Frame Type Thermal Break? Yes No Comments: Q Wfnhdow 12:Wood Frame:Double Pane wait Low-E,U-fwhx.0.340 For windows without labeled U-factors,describe features: Wanes Frame Type Thermal Break? Yes No Comment ❑Window 13:Wood Frame:Double Pane with Low-E,U-factor.0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Convnents: Q W eidow 14:Wood Frameflouble Pane with Low-E.U-factor 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Cam: Q Window 15:Wood Frame:Double Pane with Low-E,U-factor 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Q Widow 16:Wood Frame:Double Pane with LSE.U-factor 0.340 For windows without labeled U-factors,describe features: Wanes Frame Type Thermal Break? Yes No Commends: Q Window 17:Wood Frame:Double Pane with Low-E,U-factor 0.340 For windows without labeled U-factu,a,describe features: Wanes Frame Type Thermal Break? Yes No Commen Q Widow 18:Wood Frame:Double Pane with Low-E,U-factor 0.340 For windows without labeled U-factors,describe features: Wanes Frame Type Thermal Break? Yes No HUNT RESIDENCE Page 5 of 8 • Comments: Window 19:Wood Frame:Double Pane with Low-E.U-factor 0.340 For windows without labeled 1.1-factors,descnbe features: *Panes Frame Type Thermal Break? Yes No Comments: Ci Wm(lovv 20:Wood Frairw:Double Pane with Low-E.IMactor:0.340 For windows without labeled ti-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 0 Window 21:Wood Frame:Double Pane with Laiv-E,Li-factor 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: CI Window 22:Wood Frame:Double Pane with Low-E,U-factor 0.340 For windows without labeled U-fackirs,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 0 Window 23:Wood Frame:Double Pane with Low-E,U-factor 0.340 For windows without labeled ll-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: CI Door 1:Solid,U-factor 0240 Comments: El Door 2:Glass,U-factor 0.240 Comments: Floors: Cl Floor 1:All-Wood Joist(Truss:Over Unconditioned Space,R-30.0 rawly insulation Coniments• Heating and Cooring Equipment CI Furnace 1:Forced Hot Air 90 AFUE or Wiper Make and Model Number Air Leakage: O Joints,penetrations,and all other such openings in the building envelope that are solaces of air leakage are sealed. ri Recessed fights are 1)Type IC rated,or2)kistaed inside an appropriate air-light assembly with a 0.5*clearance kyr cornbustffile materials.If non-IC rated,echoes are'vistaed with a 3"clearance*OM insulation. Vapor Retarder: a installed on toe warm-in-wkder side of a non-vented framed calkigs,waits,and floors_ Materials Identification: a Matecials and equipment are installed in accordance%Oh the memufacturer's instaation kistructions, D Materials arid equipment are identified so that compliance can be determined. u Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ci Insulation R-values,glazing U-factors,and healing equipment efficiency are clearly marked on the building plans or spedffications. Cl Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner mat achieves Me rated R-value without compressing the insulation. Duct Insulation: O Supply ducts in unconditioned attics or outside the batting are insulated to R-11. HUNT RESIDENCE Page 6018 • . a Return ducts in unconditioned attics or outside the brazing are insulated to R-6. Supply ducts hi unconditioned spaces are insulated to R-11. cr I ft O Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction; O All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric, or tapes.Tapes and mastics are rated UL 181A or UL 1818. Exceptions: Continuously welded and locking-type longitudinal joints and serails on ducts operating at less than 2 in_w.g.(500 Pa). i3 The HVAC system provides a means for balancing air and water systems, Temperature Controls: O Each dwelling unit has at least one thermostat capable at automatically adjusting the space temperature set point of the largest zone. Electric Systems: O Separate electric meters exist for each dwelling unit. Fireplaces: O Fireplaces are installed with tight fitting non-combustible fireplace doors. Fireplaces have a source of combustion air,as requited by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Budding Code,as applicable. Service Water Heating: ci Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap oils part of a circulating system. O Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: 0 Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: O All heated swimming pools have an ordolf heater switch and a cover unless over 20%of the healing energy is from non-clepletable sources_Pool pumps have a time clock. Healing and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chtled*lids below 55 degrees F are insulated to the levels in Table 2. • HUNT RESIDENCE Page 7 c4 8 • Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-CiMulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 125' 1.5'to 2.0' Over 2' Temperature en 170-180 0.5 1.0 1.5 2.0 140-189 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes insulation Thickness in inches by Pipe Sizes Fluid Temp. Piping System Types Range'F3 2'Runouts 1"and Less 1.25'to 2.0' 2.5'to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) My 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) r- HUNT RESIDENCE Page 8 of 8