ResCheck a ryi REScheck Software Version 4.6.4
u) cnmN
Compliance Certificate o " o al
o �
� 3 = I"
70, N N
Ul
Project FoothillsBuilders Inc - m § CO
o�ec es D IEJUN
� No. m11]
0Energy Code: 2015 IECC VJLocation: Glens Falls, New York 2 20,19 a a. l
Construction Type: Single-family _ N I"' n
Project Type: New Construction rw` 0 n
Conditioned Floor Area: 2,346 ft2 TOWN OF QUEENSBURY O
Glazing Area 12% BUILDING&CODES f W
Climate Zone: 6 (7635 HDD) t0
Permit Date: 0
1,4
Permit Number: . 0
N N
Construction Site: Owner/Agent: Designer/Contractor: i'' t0
John Clendon Drive Daniel W. Ryan P.E.
Lot#7 206 Glen Street
Queensbury, NY 12804 Ste 30
Glens Falls, NY 12801
518-792-9264
ompliance: Passes using UA trade-off
Compliance: 0.0%Better Than Code Maximum UA: 307 Your UA: 307
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling 1: Raised or Energy Truss 1,072 49.0 0.0 0.020 21
Ceiling 2: Cathedral Ceiling 209 21.0 0.0 0.048 10
Wall 1: Wood Frame, 16" o.c. 1,287 21.0 0.0 0.057 62
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 113 0.290 33
Door 1: Solid 20 0.240 5
Door 2: Solid 18 0.140 3
Door 3: Glass 40 0.290 12
Wall 2: Wood Frame, 16" o.c. 1,262 21.0 0.0 0.057 64
Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 142 0.290 41
Floor 1: All-Wood Joist/Truss:Over Outside Air 24 30.0 0.0 0.033 1
Floor 2: All-Wood Joist/Truss:Over Unconditioned Space 317 30.0 0.0 0.033 10
Basement Wall 1: Solid Concrete or Masonry 1,076 0.0 19.0 0.038 40
Wall height: 7.8'
Depth below grade: 7.0'
Insulation depth: 7.8'
Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 1 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
t
,
Compli•nc• Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calc atio s submitted with the permit application.The proposed . ' .ing has been designed to meet the 2015 IECC re irements in
RE ,chec Version 4.6.4 and to co • with the mandatory re. ' nts listed in the REScheck Inspection Checkli .
"'me U • - •re — a
- cam
{
77
RO\z 1`e,;, to
,.......
FESSIOP\-'
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 2 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
REScheck Software Version 4.6.4
4 i"
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
kt building envelope.Thermal [Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR311 lighting and mechanical systems. ❑Not Observable
- Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR212 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods ❑Not Observable
Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 !High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 3 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
Section Plans Verified Field Verified
Foundation Inspection value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
(F04]1 insulation R-value. Where interior R_ R- ❑Does Not table for values.
insulation is used,verification ❑Not Observable
may need to occur during
Insulation Inspection. Not ENot Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ElDoes Not
manufacturer's instructions. ['Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[F06]1 insulation depth of burial or ❑Does Not table for values.
, distance from top of wall. ❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[F011]2 to protect exposed exterior ❑Does Not
insulation and extends a
❑Not Observable
minimum of 6 in. below grade.
ONot Applicable
403.9 Snow-and ice-melting system ElComplies
[F012]2 controls installed. ❑Does Not
4s ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) i 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 4 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
•Section Plans Verified Field Verified
# Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U- U- ElComplies See the Envelope Assemblies
402.3.4 EDoes Not table for values.
[FR1]1 ENot Observable
ENot Applicable
402.1.1, Glazing U-factor(area-weighted U- , U- ElComplies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, ❑Not Observable
402.5 ENot Applicable
[FR2]'
303.1.3 U-factors of fenestration products ElComplies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. ['Not Observable
ENot Applicable
402.4.1.1 Air barrier and thermal barrier ElComplies
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
[Not Observable
ENot Applicable
402.4.3 Fenestration that is not site built ElComplies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/1.5.2/A440
or has infiltration rates per NFRC [Not Observable
400 that do not exceed code ENot Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ElComplies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate 52.0 cfm
leakage at 75 Pa. ENot Observable
❑Nat Applicable
403.2.1 Supply and return ducts in attics ElComplies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >= ❑Not Observable
R-6 where < 3 inches. Supply and
return ducts in other portions of ENot Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ElComplies
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
ENot Applicable
403.4 HVAC piping conveying fluids R- R- ElComplies
[FR17]2 above 105 °F or chilled fluids ❑Does Not
below 55 °F are insulated to >R-
J ['Not Observable
3.
ENot Applicable
403.4.1 Protection of insulation on HVAC ElComplies
[FR24]i piping. ❑Does Not
x [Not Observable
ENot Applicable
403.5.3 Hot water pipes are insulated to R- R ❑Complies
[FR18]2 >_R-3. ElDoes Not
ENot Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 5 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
Additional Comments/Assumptions: '
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 6 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
•
Section Plans Verified Field Verified
Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled EComplies
[IN13]2 or the installed R-values ❑Does Not
provided. ENot Observable
ENot Applicable
402.1.1, Floor insulation R-value. R- R- EComplies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 ❑ Steel ❑ Steel ENot Observable
ENot Applicable
303.2, Floor insulation installed per EComplies
402.2.7 manufacturer's instructions and EDoes Not
[IN2]1 in substantial contact with the
underside of the subfloor, or floor ['Not Observable
framing cavity insulation is in ENot Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). Steel ❑ Steel ENot Applicable
303.2 Wall insulation is installed per EComplies
[IN4]1 manufacturer's instructions. ❑Does Not
ENot Observable
❑Not Applicable
Additional Comments/Assumptions:
1 i High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 7 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
Section Plans Verified Field Verified •
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ['Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel [Not Observable
402.2.6
[FI1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F121' Blown insulation marked every
300 ft2. ['Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ElComplies
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[F13]1 insulation ?R-value of the ❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
['Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[F14]1 cfm/100 ft2 across the system or ft2 ft2 DDoes Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ❑Not Observable
tests, verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F127]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
['Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[F19)2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications. [hot Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI10J2 on heat pumps. ❑Does Not
['Not Observable
ENot Applicable
403.5.1 Circulating service hot water EComplies
[FI11J2 systems have automatic or ❑Does Not
accessible manual controls.
[Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 8 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
•
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system ❑Complies
(1125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. [Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[F12612 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water [Not Observable
temperature based on outdoor ENot Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
(1128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[F12912 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ENot Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
[F130]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F. •
403.5.4 Drain water heat recovery units ❑Complies
[FI3112 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat [Not Observable
recovery units < 3 psi for ENot Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers. _
404.1 75%of lamps in permanent ❑Complies
[F16]' fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ENot Observable
lighting. ENot Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. Oboes Not
4.3, ENot Observable
❑Not Applicable
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 9 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. ❑Complies
[F17]2 EDoes Not
['Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[F11813 mechanical and water heating ❑Does Not
systems have been provided.
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Foothills Builders Inc Report date: 06/07/19
Data filename: C:\Users\DWR Desktop\Dropbox\DWRPE Engineering\Active Projects\1443 - DES - FHB Page 10 of10
Lot 7 John Clendon Dr\1443 ResCheck.rck
A .
i CI 20 I
Efficie15ncyCG Energy Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 19.00
Floor 30.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.29
Door 0.29
Heating& Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments