2019-07-24 Final Envelope Testing Report Fairfield Inn27 Cohoes Road Watervliet, New York 12189 | 518.874.1604 | Fax 212.731.0372| www.thepakatargroup.com
July 24, 2019
Dick White
Bette & Cring Construction Group
22 Century Hill Drive, Suite 201
Latham, NY 12110
RE: Energy Code Compliance Testing Verification
PROECT: Fairfield Inn 21 Big Boom Road, Queensbury, NY
PERMIT #: NA
Dear Dick,
As per your request we have conducted the following Energy Code Compliance Inspections and/or tests.
☐Thermal Bypass Inspection, prior to insulation installation
☐Duct Tightness Testing when applicable
☒Infiltration and Air Leakage Testing (Blower Door Test)
The purpose of our testing/inspections are to provide independent verification of as built conditions as
they specifically relate to the applicable version of the adopted energy code. We are not in any way
responsible for the means, methods, materials or equipment used in constructing this Commercial
Building and make no warranty as to their suitability for such.
Our testing and/or inspections are in accordance with the applicable version of the International Energy
Conservation Code, ASTM Testing Protocols, Building Performance Institute Standards, and Resnet
Standards for these tests/inspections.
Equipment used for this report includes:
✓Retrotec Blower Door, Model # 5000 (2 used)
✓Retrotec Blower Door, Model #1000
✓Flir Infrared Imager Model C2
All equipment used for these testing/inspections have current and valid calibrations as specified by the
manufacturer.
All technicians completing this work hold current and valid certifications as noted on the report
documents.
The following data was obtained during testing on July 24, 2019:
Envelope Properties:
Floors: 520 SF
Walls: 21,618 SF
Roof: 14,352 SF
Total: 36,490 SF
Allowed Infiltration: 0.40cfm/sf or 14,596cfm at 75 PA
Confirmed Actual Infiltration: 0.38cfm/sf or 13919cfm at 75 PA
Based on our confirmed testing your commercial building is in compliance with 2016 Energy
Conservation Construction Code, Section C402.5 Air Leakage- thermal envelope.
Thank you for choosing The Pakatar Group, LLC for your energy consulting needs.
Respectfully submitted,
The Pakatar Group, LLC
By:
Alexander Pakatar, NEBB BET Professional