Loading...
special inspections 10 NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-8511 June 8, 2005 Mr. David Hatin Town of Queensbury Bldg. &Codes Dept. 742 Bay Road Queensbury,NY 12804 Re: Clute— Luzerne Road Storage Buildings Dear Dave: This is to inform you that Larry Clute has retained me to make structural inspections of the storage buildings he is building for mini-storage on Luzerne Road. Since all of the structural components of the buildings are accessible, I will be performing my inspections when the building(s) are completed. I will forward my final inspections to you for your files. Please call me if you have any questions regarding this matter. Sin erely, Thomas W. Nace, P.E. cc: Larry Clute ,JUN-13-05 MON 08:48 AM E & T O'CONNOR INC, FAX NO, 5187924194 P. 02/03 r CONSTRUCTION TECHNOLOGY INSPECTION& TESTING DIVISION, P.D.&T.S., INC. 4 William Street, Ballston Lake,New York 12019 Phone: (518)399-1848 Fax: (518)399-1913 CLIENT: O'CONNOR CONSTRUCTION,INC. REPORT NUMBER: 2.PAGE#. 1 POST OFFICE BOX 377 INSPECTION DATE: 06/01/05 GLENS FALLS,NEW YORK 12801 OUR FILE NUMBER: 866.005 FIELD INSPECTOR: DAVE CASAW ATT'N: MR. BRIAN O'CONNOR PROJECT:WESTSIDE STORAGE FACILITY,GLENS FALLS,NEW YORK SOIL COMPACTION VERIFICATION REPORT ::: INPLACE SOIL DENSITY MATERIALS LABORATORY DATA CODE MOISTURE MAX DENSITY PCF MATERIAL DESCRIPTION MATERIAL SOURCE 7144 5.3 138.8 SAND,medium;and fine Gravel;little Silt/Clay BORROW FIELD COMPACTION TEST RESULTS LOCATION OF TESTING: SLAB ON GRADE SUBGRADE ELEVATION REFERENCE: F.G.=FINISH GRADE=TOP OF SLAB SUBGRADE COMPACTION TEST METHOD ASTM D-2922 ICO-ORDINATE REFERENCE: PER LOCATION COMPACTION REQUIREMENTS 95% TEST EST SOIL SOIL DEPTH OR f MOISTURE INPLACE DRY PERCENT NO. BEARING CODE ELEVATION LOCATION OF TEST CONTENT DENSITY(PCO— COMPACT 1 7144 FINISH GRADE PAD#2,NORTH END 2.6% 136.E 98.4 2 � 7144 FINISH GRADE i PAD#2,CENTER 2.9% 134.5 87.1 % 3 7144 FINISH GRADE PAD#2,SOUTH END _ 3.0% 133.0 95.8% 4 7144 FINISH GRADE PAD#1,NORTH END 2.5% 135.3 __ 97.5 5 7144 FINISH GRADE PAD#1,CENTER 2.7% 136.6 98.4% 6 7144 FINISH GRADE PAD#1,SOUTH END , 2.8% 132.4 95.4% T- J REPORT DISTRIBUTION GENERAL NOTES: RESPECTFULLY SUBMITTED, 1 FILE 1.D-1556=SAND CONE METHOD OF TEST CONSTRUCTION TECHNOLOGY . 2. 2. D-2922=NUCLEAR GAUGE METHOD OF TEST A 3 3. FF ^FINISHFLOOR 4: 4. FG =FINISH GRADE 5: 5. TOM JOSLIN.S,E.T. (NICET) 6: 6. MANAGER TECHNICAL SERVICES ,.JUN-13-05 MON 08:49 AM E & T O'CONNOR INC. FAX NO, 5187924194 P. 03/03 CONSTRUCTION TECHNOLOGY INSPECTION& TESTING DIVISION, P.U.&T.S., INC. 4 William Street,Ballston Lake,New York 12019 Phone:(518)399-1848 Fax:(518)399-1913 CLIENT: O'CONNOR CONSTRUCTION, INC. REPORT NUMBER: 1. PAGE#: 1 POST OFFICE BOX 377 INSPECTION DATE: 06/01/05 GLENS FALLS,NEW YORK 12801 OUR FILE NUMBER: 866.005 FIELD INSPECTOR: DAVE CASAW ATT'N: MR.BRIAN O'CONNOR PROJECT:WESTSIDE STORAGE FACILITY,GLENS FALLS,NEW YORK SOIL COMPACTION VERIFICATION ON REPORT ::: INPLACE SOIL DENSITY MATERIALS LABORATORY DATA CODE MOISTURE MAX DENSITY PCF MATERIAL DESCRIPTION MATERIAL SOURCE 1 7144 , 6.3 - 138.8 SAND,medium:and fine Gravel;little Silt/Clay BORROW M FIELD COMPACTION TEST RESULTS LOCATION OF TESTING' SLAB ON GRADE SUBGRADE ELEVATION REFERENCE: F.G.=FINISH GRADE=TOP OF SLAB SUBGRADE COMPACTION TEST METHOD ASTM D-2922 CO-ORDINATE REFERENCE: PER LOCATION COMPACTION REQUIREMENTS 95% TEST SOIL SOIL DEPTH OR MOISTURE INPLACE DRY PERCENT NO- BEARING CODE ELEVATION LOCATION OF TEST CONTENT_DENSITY(PCF) COMPACT 1 7144 FINISH GRADE PAD#5.NORTH END _-. 2.8% 134.9 97.2 2 7144 FINISH GRADE PAD#5,CENTER 2.4% 134.1 96.6% 3 � 3.1 % 135.9 97.9%7144 FINISH GRADE PAD#5,SOUTH END _ --- • 4 7144 I FINISH GRADE PAD#4,NORTH END 2.3% 134.5 96.9% 5 7144 FINISH GRADE PAD#4,CENTER 2.4% 134.6 97.0% .6 _ 7144 FINISH GRADE PAD#4,SOUTH END 2.7% 135.2 j 97.4 7 7144 FINISH GRADE PAD 1t3,NORTH END 2.5% 136.2 98.1 °/_j_ _.---- 8 7144 FINISH GRADE PAD#3,CENTER 3.0% 135.2 97.4%� g 7144 FINISH GRADE PAD#3.SOUTH END - • 2.8% 133.2 96-0% 1 J REPORT DISTRIBUTION: GENERAL NOTES: • RESPECTFULLY SUBMITTED, 1'FILE 1. D-1556=SAND CONE METHOD OF TEST CONSTRUCTION TECHNOLOGY 2: 2. D-2922=NUCLEAR GAUGE METHOD OF TEST 3 3. FF =FINISH FLOOR 4: 4. FG =FINISH GRADE 6 5 TOM JOSLIN.S.E,T,(NICET) 6: 6 MANAGER TECHNICAL SERVICES 1 4N-21-2005 12 : 19 AM CONSTRUCTION TECH. 518 399 1913 P. 02 I CONSTRUCTION TECHNOLOGY INSPECTION & TESTING DIVISION, P.D.&T.S., INC. 4 William Street,Ballston Lake,New York 12019 Phone:(518)399-1848 Fax: (518)399-1913 June 21, 2005 TOWN OF QUEENSBURY BUILDING DEPARTMENT 742 Bay Road Queensbury,New York 12804 Att'n: Mr, David Hatin Re: LUZERNE ROAD SELF-STORAGE,QUEENSBURY,NEW YORK Construction Materials Inspection and Testing Services Dear Mr. Hatin, Per the request of Mr. Brian O'Connor, O'Connor Construction, Inc.,we are pleased to inform you that CONSTRUCTION TECHNOLOGY has been retained to provide the construction materials inspection and testing services required of the upcoming referenced project. As such, we would like a moment to introduce our organization. CONSTRUCTION TECHNOLOGY is the construction materials inspection division of Product Development & Technical Services, Inc. Since our 1984 incorporation in New York State,we have been devoted to providing the highest standards of on time field inspection, testing and laboratory support to the construction industry. Our desire is a QC/QA involvement with projects committed to timely completion while satisfying the quality controls and assurances necessary to support today's strict design criteria. All to often materials inspections are viewed as a necessary evil or a requirement to be overlooked. Many times the laboratory brings this attitude on itself because of less than fully qualified personnel,tardy response time or uncompromising attitudes of technicians. Given the opportunity, we are confident we can provide the services that reflect our strong desire to be an asset to the construction process. Our facility and field technical force is supported by state of the art test equipment, including nuclear soil/asphalt density test equipment,automatic soil moisture/density (Proctor) apparatus, temperature/humidity controlled curing environments for concrete specimens, and all other necessary equipment to satisfy the requirements of the American Society for Testing and Materials(ASTM) standards C-1077 and E-329 as they relate to a commercial inspection agency. CONSTRUCTION TECHNOLOGY has submitted to outside auditing by having our personnel, equipment, facility and quality assurance plan evaluated by the Cement and Concrete Reference Laboratory (CCRL) of the National Standards Institute. A copy of the CCRL/NSI audit and finding is available upon request. 40N-21-2005 12 :20 AM CONSTRUCTION TECH. 518 399 1913 P. 03 June 21, 2005 TOWN OF QUEENSBURY BUILDING DEPARTMENT Re: LUZERNE ROAD SELF-STORAGE,QUEENSBURY,NEW YORK Construction Materials Inspection and Testing Services Our staff ranges from consultant Professional Engineers, hydrologists and geologists to field technicians and materials inspectors with technical backgrounds of educational degrees and/or substantiated experience in a construction oriented discipline. Field inspectors also possess a combination of the following certifications: * Certification at various levels (AET-I through SET-IV)by the National Institute for Certification in the Engineering Technologies (NICET). * American Concrete Institute (ACI) Grade I Concrete Inspector. * American Concrete Institute (ACI)Certified Concrete Construction Special Inspector. * Troxler Nuclear Gauge Training Program for Radiation Safety Officers and Field Operators. * J&L Testing,Inc. Certification Program for Sanitary Landfill Inspectors. * J&L Testing,Inc. Certification Program for Quality Control and Inspection of Geosynthetic Systems for Use in Solid and Hazardous Waste Disposal Facilities. In addition to particular qualifications, field inspectors are familiar with all phases of construction materials testing and inspection including soils, concrete, reinforcement,masonry, structural steel, fireproofing and roof installation. This generally alleviates the need and expense of employing more than one inspector on a particular project. CONSTRUCTION TECHNOLOGY currently has the capabilities to provide inspection and testing services relating to many construction concerns including but not limited to: subsurface drilling and investigation, soils placement and compaction, foundation design recommendations,portland cement concrete,unit masonry, mortars, grouts, bituminous concrete, structural steel and fireproofing, as well as all associated laboratory services. In general,all forms of materials testing and inspection services, as they relate to the construction industry, may be obtained through CONSTRUCTION TECHNOLOGY. We appreciate your interest in our firm and our line of work. We look forward to serving the construction materials inspection,testing and laboratory requirements of the LUZERNE ROAD SELF-STORAGE. If there are any questions, or when we may be of assistance, please contact this office immediately. Respectfully, CONSTRUCTION TECHNOLOGY Tom Joslin, S.E.T., (NICET) Manager Technical Services CONSTRUCTION TECHNOLOGY INSPECTION&TESTING DIVISION, P.D.&T.S., INC. ZE70��—kA"1(9 4 William Street, Ballston Lake,New York 12019 Phone: (518)399-1848 Fax: (518)399-1913 CLIENT: O'CONNOR CONSTRUCTION,INC. REPORT NUMBER: 4 :PAGE#: 1 POST OFFICE BOX 377 PREPARATION DATE: 07/06/05 GLENS FALLS,NEW YORK 12801 OUR FILE NUMBER: 866.005 INSPECTOR&TEST SET: SCOTT ROBBINS #17 ATT'N: MR.BRIAN O'CONNOR AMBIENT WEATHER: 70's:CLOUDY PROJEC WESTSIDE STORAGE FACILITY,GLENS FALLS, NEW YORK OUR FILE LOCATION: 55674 CONCRETE FIELD INSPECTION & COMPRESSION TEST RESULTS PLACEMENT LOCATION OF LOAD# 1 : SLA B ON GRADE:UNIT#4 DELIVERED LOAD NUMBER 1 TRUCK NUMBER/TICKET NUMBER: NA/ 736901 YARDAGE DELIVERED/SUBTOTAL: 11.00/ 11.00 TIME CONC. BATCHED/ARRIVED: 6.20/ 6.48 TIME PLACEMENT BEGAN/ENDED: 6.50/ 7.15 CONCRETE AGE(HOURS) (SPEC: MAX: 1.50) 0.92 SLUMP ON ARRIVAL (INCHES): 7.00 WATER ADDED ONSITE(GALLONS): WATER ADDED AT DISCRETION OF: SLUMP OF CONCRETE INTO PUMP: IF APPLICABLE: PLACEMENT SLUMP(INCH) (SPEC: - 5.00) 7.00 1 ENTRAINED AIR (%VOL) (SPEC: 4.00 - 7.00) 5.70 UNIT WEIGHT (PCF) (SPEC: - ) 144.10 CONCRETE TEMP. (F) (SPEC: 45 - 85) 80 NUMBER OF TEST SPECIMEN CAST: 6 LAB CYLINDER CONTROL NUMBERS 55674- 55679 REMARKS: 1: CNTRACTOR NOTIFIED:SLUMP UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 CONCRETE SUPPLIER: JOINTA-GALUSHA CONCRETE CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM:C39 CONCRETE DESIGN STRENGTH: 4000 P.S.I.@ 28 DAYS UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: 07/07/05 SUPPLIERS MIX FORMULA: PER SUBMITTAL: CEMENT: LBS. CYLINDER TEST TEST AGE ULTIMATE LOAD UNIT CEMENT: LBS. NUMBER DATE DAYS & BREAK TYPE P.S.I. WATER: GAL. COARSE AGGREGATE#1: LBS. 55674 07/13/05 7 82,150 C 2910 COARSE AGGREGATE#2: LBS. 55675 07/13/05 7 80,800 C 2860 COARSE AGGREGATE#3: LBS. 55676 08/03/05 28 FINE AGGREGATE: LBS. 55677 08/03/05 28 ADMIXTURE#1: OZS. 55678 08/03/05 28 ADMIXTURE#2: OZS. 55679 SPARE ADMIXTURE#3: OZS. AIR ENTRAINING AGENT: OZS. REPORT DISTRIBUTION: 1:FILE 5: 2:SUPPLIER 6: 3: 7: 4: 8: RESPECTFULLY SUBMITTED, CO TECHNOLOGY TOM JOSLIN,S.E.T. (NICET) MANAGER TECHNICAL SVCS. � ..— —.. ----- .—.--- I 0 5x5 10x5 / lOxIG (� 6_ 10x20 10x20 can I i 1 2 (,Ail `x ,a IDx!0 m�' i Sx5 _. 10x5 C•3F SOFT = 2.702.3a :LCO7R SO.FT = 2,700 1 , n 5k51 I 10x5 ,� 10x10 I 0 10x20 10x23 N 0 Zr _i x So 10x10 i w' 5x5 t I :0x5 in (5X5 I i I 1 p 10x10 10x10 10x10 I• 10K30 inI u,n { 10x20 L3x2.0 . { zen I _j x 10x3G So IOxID 10x10 i ! .`�' 5k5 I — 1 ,n sxs { Icxs 1 8/00) 4L q a 10x10 IOx10 . 10x10 10x10 10xi0 IOxlD • c• f z el Qx • 5. iDx10 i0x10 toxic IOxIO IOxi0 10x10 "'", sxs I0x5 In sxs 0 10x20 10x20 in uin zel ^xS. I smi^' 5x5