inspection slips Commercial Final Inspection Report ) -// I/
L
Office No.: (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/prl�1�'�-/ Depart: am/pm
^
742 Bay Road, Queensbury,NY 12804 Inspector's Initials: -�
NAME: PERMIT#: _ 0.40 . — i f
LOCATION: y L vZ (- rJ 4 DATE: -- i,i �_�
ei‘ ostsi COMMENT'
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete i
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w/Lever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'A doors
> 10%> 1000 sq. ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required ,
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond
Active Listening S t m a Si e Asse bly Space
`). Final Electrical c/5 ? Ci Site Plan/Variance req ed
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20'wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building 8s Codes\Commercial Final Inspection Report.doc
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection re' d:
Queensbury Building& Code Enforcement Arrive: • re pm %i I part: ,1- a /pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initi. j�
NAME: \J�ti PERMIT#: • 1 (09
LOCATION: r:
al{� L UZS?�Y'fl_Q_ �� INSPECT OIL. . --_ —r�
TYPE OF STRUCTURE: S}TGO �, 1
s \
Y N N/A COMMENTS
V-aming
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side % inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
3-, Cam( v
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection req st received: V-2,
Queensbury Building &Code Enforcement Arrive: am/ Depart: / 30m/pm,;
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: [
NAME: L C I' l �'''� S PERMIT#: vy - Q
LOCATION: yU Lv z - .c' Q (2 ) INSPECT ON:
TYPE OF STRUCTURE:
Comment•
Y N N/A
ootings
P'ers
Monolithic Slab
Reinforcement in Place •i
The contractor is responsible
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/ Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHerningway\Building.Codes.Inspcction.FORMS\Foundation Inspection Repott.doc January 28,2003
NACE ENGINEERING, P.C.
169 Haviland Road, Queensbury,NY 12804
Phone-518-745-4400 Fax -518-792-8511
June 8, 2005
Mr. David Hatin
Town of Queensbury Bldg. & Codes Dept.
742 Bay Road
Queensbury, NY 12804
Re: Clute—Luzerne Road Storage Buildings
Dear Dave:
This is to inform you that Larry Clute has retained me to make structural inspections of the storage
buildings he is building for mini-storage on Luzerne Road. Since all of the structural components
of the buildings are accessible, I will be performing my inspections when the building(s) are
completed. I will forward my final inspections to you for your files.
Please call me if you have any questions regarding this matter.
Sin erely,
Thomas W. Nace, P.E.
cc: Larry Clute
c a, 5 5 '0>5
10x1G
6.
( IOx20 10x20
x
Ize4 5X5 a - - IDx't0 I —_
10x5
RC.JF SO.FT = 2.70.?.36. LOOR SOFT = 2,700
to 5x5 1 - 10x5
4 I IOx!0 i
0
al10x20 + I0x23
uin i
z
Fx i •
-o lOxli] 1
a,c'' 5X5 :0x5
I I I
t I I
In5X5 I
0 tox10 I 10x10 toxIo ! lOx3G
in I !
u� _ 10x20 (Dx20 . i
1
_ix 10x3G 1
10xID ICx10
�c 1
^' 5X5 !
•
in 5X5 1Cx5
!
p 10x!C IOx10 I 10x10 10,110 IOx,O 1040 •
I
z.
AX
•
010 iox10 lOxle Iox'D I IOx'O I lOxle
gin" Ox
c„ 5X5 IQx5 j
,n ! 5x5
t
0 t
in
10x20 10x20
ON
z0
Jx . , ' 1
a4^' 5X5