Loading...
inspection slips Commercial Final Inspection Report ) -// I/ L Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/prl�1�'�-/ Depart: am/pm ^ 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: -� NAME: PERMIT#: _ 0.40 . — i f LOCATION: y L vZ (- rJ 4 DATE: -- i,i �_� ei‘ ostsi COMMENT' Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete i Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.w/Lever Handles/Panic Hardware, if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'A doors > 10%> 1000 sq. ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required , Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond Active Listening S t m a Si e Asse bly Space `). Final Electrical c/5 ? Ci Site Plan/Variance req ed Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building 8s Codes\Commercial Final Inspection Report.doc Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection re' d: Queensbury Building& Code Enforcement Arrive: • re pm %i I part: ,1- a /pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initi. j� NAME: \J�ti PERMIT#: • 1 (09 LOCATION: r: al{� L UZS?�Y'fl_Q_ �� INSPECT OIL. . --_ —r� TYPE OF STRUCTURE: S}TGO �, 1 s \ Y N N/A COMMENTS V-aming Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 3-, Cam( v Foundation Inspection Report Office No. (518) 761-8256 Date Inspection req st received: V-2, Queensbury Building &Code Enforcement Arrive: am/ Depart: / 30m/pm,; 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: [ NAME: L C I' l �'''� S PERMIT#: vy - Q LOCATION: yU Lv z - .c' Q (2 ) INSPECT ON: TYPE OF STRUCTURE: Comment• Y N N/A ootings P'ers Monolithic Slab Reinforcement in Place •i The contractor is responsible providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHerningway\Building.Codes.Inspcction.FORMS\Foundation Inspection Repott.doc January 28,2003 NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-8511 June 8, 2005 Mr. David Hatin Town of Queensbury Bldg. & Codes Dept. 742 Bay Road Queensbury, NY 12804 Re: Clute—Luzerne Road Storage Buildings Dear Dave: This is to inform you that Larry Clute has retained me to make structural inspections of the storage buildings he is building for mini-storage on Luzerne Road. Since all of the structural components of the buildings are accessible, I will be performing my inspections when the building(s) are completed. I will forward my final inspections to you for your files. Please call me if you have any questions regarding this matter. Sin erely, Thomas W. Nace, P.E. cc: Larry Clute c a, 5 5 '0>5 10x1G 6. ( IOx20 10x20 x Ize4 5X5 a - - IDx't0 I —_ 10x5 RC.JF SO.FT = 2.70.?.36. LOOR SOFT = 2,700 to 5x5 1 - 10x5 4 I IOx!0 i 0 al10x20 + I0x23 uin i z Fx i • -o lOxli] 1 a,c'' 5X5 :0x5 I I I t I I In5X5 I 0 tox10 I 10x10 toxIo ! lOx3G in I ! u� _ 10x20 (Dx20 . i 1 _ix 10x3G 1 10xID ICx10 �c 1 ^' 5X5 ! • in 5X5 1Cx5 ! p 10x!C IOx10 I 10x10 10,110 IOx,O 1040 • I z. AX • 010 iox10 lOxle Iox'D I IOx'O I lOxle gin" Ox c„ 5X5 IQx5 j ,n ! 5x5 t 0 t in 10x20 10x20 ON z0 Jx . , ' 1 a4^' 5X5