inspection slips Commercial Final Inspection Repo e
Office No.: (518) 761-8256 Date Inspection re.• :ce. -•:
Queensbury Building& Code Enforcement Arrive: V 9T .t'pm Depart: 1:0
742 Bay Road, Queensbury, NY 12804 Inspector's lnitia! •.-j,�,t
NAME: —tC i�1G PERMI
LOCATION: 7_1-4C 7 F R E_ Ri`AODATE: —
COMMENTS:
•
Y N NA
Chimney/"B"Vent/Direct Vent Loc
Plumbing Vent Through Roof 6" _oof Com lete
Exterior Finish/Grade Complete or quivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/ Exterior Ballisters 4 in. Spacing Platform/Decks _
Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in. w/Lever Handles/Panic Hardware,if required
Exits At Geradue Or Platform 36 (w)x 44"(I)/Canopy or Equiv. - 7 i J t rip 1 L
asValve Tit-off Exposed&Regulator(18") Above Grade
Floor Bathroom Watertight/Other Floors Okay 0 F T01 u M)IR
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System C.i
_ Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers _
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors
> 10%> 1000 sq. ft.
'/a Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond [Both sides]
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survy, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20' wide
Okay To Issue Temp. or Permanent CIO
Okay To Issue C/C
L:\Building& Codes:Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc
05/16/2008 20: 48 518-543-6156 ARTHUR V STEFTZ PAGE 01
— .
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Kurt Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
0
Permit No.. Cert. 3363 cut-in
Owner...OTE•Z 'e/24/..0 AS.1 -1/01V A rdto
..., _,,
Location oirl'V 1) ,orldi 7 e x.A,,.c..-.. /zi. .14.e.e.„4/.. .,&.2,... /.........
/
InAllation COnsiStipg of _..........._
1,big. i' --7-0./LiPt 7r. 4 4eii, l-74,/ . ----
. ..
Installed By ge h.e 7.-- i C Lic.No.
The condition/following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and,installation conditions as of date Upon the
introduction of additional equipment or alterations, tpplie4Sn shall be promptly made for inspecti7
inspectors of this Company shall have the privilege maki inspections at any time, and it it
rules are violated, he Company shall have the right iv oke • enificat 1 ./
Datc•NI.. Ae'd le
/
I NSPL(TOR
'...... • * 'd ./(..‘"fri/ : ,
m tser MAFIA..I
--/Z7ARs44y
Commercial Final Inspection Report
Of t e No.: (518) 761-8256 Date Inspection r ec we .
Queensbury Building&Code Enforcement Arrive: a m Depart: '_ ♦ • • •m
742 Bay Road,Queensbury,NY 12804 Inspector'ssp� Initi s: _
NAME: Zti2e .r � 0ld(/ S 1 RMIT
LOCATION: � D Z 7-er DATE:
COMMENTS:
Y N NA
Chimne /"B"Vent/Direct Vent Location _ 1
P m 6" f Com lete ✓
Exterior Finish/Grade Complete in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w/Lever Handles/Panic Hardware, if required f L
xits At Grader Platform 36 (w)x 44"(1)/Canopy or Equiv. �I0:311, OV- TCYCTIL pj1�bJ
Gas'V 1ve Shut-off Exposed&Regulator(18")Above Grade
F� t o t/ erer doors Oka ,
Relief Valve,Heat Trap/Water Z emp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'A doors
> 10%> 1000 sq. ft.
3 Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors 60-
Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed U
Handicapped Bathroom Grab Bars/Sinks/Toilets �
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in. Beyond [Both sides]
Active Listening System and Signage Assembly Space _
Final Electrical
('`Site Pl Variance required
Final Survey,New Structur Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20' wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
L:\Building&Codes Forms\Building& Codes\Inspection Forms\Commercial Final Inspection Report.doc
Framing / Firestopping Inspection Report
Oft .:e No. (518) 761-8256 Date Inspection 4 re
Queensbury Building & Code Enforcement Arrive: • y� - •-rt: am
742 Bay Road, Queensbury, NY 12804 Inspector's Initial .
NAME: L U zern . frioui l4 RMIT#:
LOCATION: ,4/c7 L v.? Ul<=c4 NSPECT ON:
TYPE OF STRUCTURE:
Y N N/A COMMENTS:
Framin
Attic Access 22" x 30" minimum
Jack Studs/ Headers
Bracing / Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/ Holes/ Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/ Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above I below grade
5.0 sf grade
L:\Building&Codes Forms-OLD\Building&CodesUnspection Fonns\Framing Firestopping Inspection Report.doc Revised January 7,2008
07- 6-2
As
NACE ENGINEERING, P.C.
169 Haviland Road, Queensbury,NY 12804
Phone-518-745-4400 Fax -518-792-8511
May 14, 2008
Mr. David Hatin
Town of Queensbury Bldg. & Codes Dept.
742 Bay Road •
Queensbury, NY 12804
Re: Clute—Luzeme Road Storage Buildings—Phase 2
Dear Dave:
This is to inform you that I have made a structural inspection of the new (Phase 2) self storage
buildings at the referent facility. These were visual inspections to make sure that all structural
members were installed and spot checks of the bolted connections to determine if all of the bolts
were present and had been tightened.
During my inspection I did not observe any missing structural members, loose connections of
missing blots. Therefore, based upon my inspection I believe that the storage buildings have been
erected in accordance with structural code requirements.
Please call me if you have any questions regarding this matter.
Sincerely,
Thomas W. Nace, P.E.
cc: Matt Steves
2.___/I T1 -46 lb..
7
Foundation Inspection Report •
Office No.(518)761-8256 Date Inspectioryrequ- 1 b-ive :
Queensbury Building&Code Enforcement Arrive: 2- /h : 4 epart: Z; 3l% m
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials rit
NAME: >/(d(` . - 1T#: 7 — �•L, i
LOCATION: ' 4-ehltel
P� INSPECT ON: I i —Lc —(_,—/
TYPE OF STRUCTli
Comments
(..---.;-----,..,
Y N N/A
r
ings
P (moo.,T 94,
onolithic Slab
Reinforcement in Place t7/
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building &Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM