ResCheck r,
•
REScheck Software Version 4.6.5
Compliance Cert f iluic
I r� AUG
Ili0 7 2019
Project A Timberhaven Home for Cameron &jes i rdner-Lewi
;`' TOWN OF( UECNSBURY
Energy Code: 2015 IECC ._„_ BUILDING& CODES
Location: Glens Falls, New York
Construction Type: Single-family
Project Type: New Construction
Orientation: Unspecified • 295.E-1-8 RC-0528 2019
Conditioned Floor Area: 0 ft2 Jess
& Cameron
Glazing Area 14% Gardner-Lewis, e
Climate Zone: 6 (7635 HDD) 1101d West Mountain Rd
Permit Date: Single Family Dwelling 1698 s.f.
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
Queensbury, NY Cameron&Jessie Gardner-Lewis Timberhaven Log&Timber Homes,
Queensbury, NY LLC
FILE COPY 1081 Salem Church Road
Middleburg, PA 17842
1-855-306-5678
engineering@timberhavenloghome
s.com
Compliance: Passes using UA trade-off
Compliance: 3.6%Better Than Code Maximum UA: 331 Your UA:����'I�wi�°'�ff w'EIVERG C pg gCMPLIANC
The%Better or Worse Than Code Index reflects how close to compliance the house is based on ,� E.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Wall 1:Wood Frame, 16" o.c. 292 21.0 0.0 0.057 15
Orientation: Unspecified
3357:Wood Frame:Double Pane with Low-E 28 0.300 8
Orientation: Unspecified
Comment: 2 windows
Wall 2: Wood Frame, 16" o.c. 161 21.0 0.0 0.057 8
Orientation: Unspecified
2547-2: Wood Frame:Double Pane with Low-E 17 0.300 5
Orientation: Unspecified
4717:Wood Frame:Double Pane with Low-E 6 0.290 2
Orientation: Unspecified
Wall 3:Wood Frame, 16" o.c. 68 21.0 0.0 0.057 3
Orientation: Unspecified
2947:Wood Frame:Double Pane with Low-E 10 0.290 3
Orientation: Unspecified
Wall 4:Wood Frame, 16" o.c. 394 21.0 0.0 0.057 16
Orientation: Unspecified
3347: Wood Frame:Double Pane with Low-E 22 0.300 7
Orientation: Unspecified
Comment: 2 windows
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 1 of11
ResCheck.rck
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
traps: Wood Frame:Double Pane with Low-E 46 0.270 12
Orientation: Unspecified
7280: Glass 40 0.290 12
Orientation: Unspecified
Wall 5: Wood Frame, 16" o.c. 68 21.0 0.0 0.057 3
Orientation: Unspecified
2947: Wood Frame:Double Pane with Low-E 10 0.300 3
Orientation: Unspecified
Wall 6: Wood Frame, 16" o.c. 161 21.0 0.0 0.057 8
Orientation: Unspecified
2547-2:Wood Frame:Double Pane with Low-E 17 0.300 5
Orientation: Unspecified
4717: Wood Frame:Double Pane with Low-E 6 0.290 2
Orientation: Unspecified
Wall 7:Wood Frame, 16" o.c. 292 21.0 0.0 0.057 15
Orientation: Unspecified
3357:Wood Frame:Double Pane with Low-E 14 0.300 4
Orientation: Unspecified
2935:Wood Frame:Double Pane with Low-E 7 0.300 2
Orientation: Unspecified
Wall 8:Wood Frame, 16" o.c. 648 21.0 0.0 0.057 31
Orientation: Unspecified
4157:Wood Frame:Double Pane with Low-E 34 0.300 10
Orientation: Unspecified
Comment: 2 windows
3235:Wood Frame:Double Pane with Low-E 8 0.290 2
Orientation: Unspecified
3714: Wood Frame:Double Pane with Low-E 4 0.290 1
Orientation: Unspecified
3357: Wood Frame:Double Pane with Low-E 14 0.300 4
Orientation: Unspecified
2947: Wood Frame:Double Pane with Low-E 20 0.290 6
Orientation: Unspecified
Comment: 2 windows
FCM606: Solid 22 0.190 4
Orientation: Unspecified
Wall 9:Wood Frame, 16" o.c. 84 21.0 0.0 0.057 5
Orientation: Unspecified
Wall 10:Wood Frame, 16" o.c. 137 30.0 0.0 0.049 7
Orientation: Unspecified
Comment: perimeter box area
Ceiling 1: Cathedral Ceiling 393 49.0 0.0 0.022 9
Ceiling 2: Cathedral Ceiling 393 49.0 0.0 0.022 9
Ceiling 3: Cathedral Ceiling 943 49.0 0.0 0.022 21
Basement Wall 1: Insulated Concrete Forms 1,099 23.0 0.037 41
Orientation: Unspecified
Wall height: 8.8'
Depth below grade: 7.8'
Insulation depth: 8.8'
Basement Wall 2: Insulated Concrete Forms 308 23.0 0.047 12
Orientation: Unspecified
Wall height: 8.8'
Depth below grade: 0.0'
Insulation depth: 8.8'
3347:Wood Frame:Double Pane with Low-E 22 0.300 7
Orientation: Unspecified
Comment: 2 windows
41 0.190 8
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 2 of11
ResCheck.rck
•
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Basement Wall 3: Solid Concrete or Masonry 142 0.0 10.0 0.066 9
Orientation: Unspecified
Wall height:4.0'
Depth below grade: 4.0'
Insulation depth:4.0'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature Date
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 3 of11
ResCheck.rck
•
0 REScheck Software VersionChecklist 4.6.5
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the ❑Not Observable
+1. building envelope.Thermal
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ['Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]z on loads calculated per ACCA Cooling: Cooling: ['Not Observable
Manual J or other methods Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 4 of11
ResCheck.rck
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO4]1 insulation R-value.Where interior R- R- ❑Does Not table for values.
insulation is used,verification ['Not Observable
may need to occur during
Insulation Inspection. Not ENot Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ❑Does Not
kt manufacturer's instructions. ['Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO6]1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall. ❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11)2 to protect exposed exterior ❑Does Not
insulation and extends a
0, minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO12]2 controls installed. ❑Does Not
k„ ['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 5 of11
ResCheck.rck
•
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ['Not Observable
v ❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.5 [Not Observable
[FR2]1 ❑Not Applicable
td!,.
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ODoes Not
with the NFRC test procedure or ❑Not Observable
taken from the default table.
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. [Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/1.5.2/A440 ❑Not Observable
or has infiltration rates per NFRC
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate.52.0 cfm ['Not Observable
leakage at 75 Pa. ❑Not Applicable
403.3.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>=3 inches in diameter and >= ❑Not Observable
R-6 where < 3 inches.Supply and
return ducts in other portions of [Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
,,,I;. ❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 above 105 QF or chilled fluids ❑Does Not
below 55 QF are insulated to >_R- [Not Observable
3• ❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
V, ❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. ❑Does Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 6 of11
ResCheck.rck
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 7 of11
ResCheck.rck
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided.
['Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood 0 Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies (FR10). ❑ Steel ❑ Steel ENot Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 8 of11
ResCheck.rck
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel ['Not Observable
402.2.6 ❑Not Applicable
[FI1] pp
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft2. ENot Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ['Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[FI3]1 insulation all-value of the ❑Does Not
adjacent assembly.
['Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50 = ❑Complies
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
['Not Observable
❑Not Applicable
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in [Not Observable
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[FI27]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a :Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies
[FI24]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[F19]2 installed for control of primary ❑Does Not
heating and cooling systems and [Not Observable
initially set by manufacturer to
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI10]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies
[F111]2 systems have automatic or ❑Does Not
accessible manual controls. ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 9 of11
ResCheck.rck
•
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system ❑Complies
[FI25)2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. ❑Not Observable
['Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[FI26]2 through one-or two-pipe heating Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor :Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[FI29)2 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically
adjust the energy input to the DNot Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
[FI30]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated [Not Observable
water source through a cold :Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1049F.
403.5.4 Drain water heat recovery units ❑Complies
[F131]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ['Not Observable
recovery units< 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[F16]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage [Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 10 of11
ResCheck.rck
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. ❑Complies
[F17]2 ❑Does Not
ONot Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: A Timberhaven Home for Cameron &Jessie Gardner-Lewis Report date: 05/21/19
Data filename: N:\Sales Representative\Lewis, Mike\Lewis, Cameron &Jessie\Drafting\Lewis Page 11 of11
ResCheck.rck
i20 IE
C Efficie15ncyCC Energy Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 23.00
Floor 0.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.27
Door 0.19
Heating &Cooling Equipment Efficiency
Heating System: , �f 00 0
�
Cooling System: /f/
Water Heater: JJJ /002v
Name: /Mir•• W S Date: t J 6 Zo/?