Signed Inspection Report (08-28-2019).pdfINSPECTION WORKSHEET (BINS-005440-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0625-2018 Case Module:Permit
Inspection Date:Wed Aug 28, 2019 Inspection Status:Partial Pass
Inspector:Charles Dyer Inspection Type:Building Foundation
Job Address:Parcel Number:154 CLEVERDALE RD
Queensbury, NY 12804
227.17-2-30
Contact Type Company Name Name
Engineer Environmental Design Partnership, LLC
Architect Tim McLaughlin
Applicant JEAN HOFFMAN
Contractor Stonewood Development of
Northeastern NY Inc
Granted Permission JEAN HOFFMAN
Primary Owner Stonewood Development of
Northeastern NY Inc
Concrete Contractor R. C. Springer Concrete
Checklist Item Status
Building Inspector Notes Failed
8/6/19 Footings Partial Approval
- House and Garage Footings
8/14/19 foundation walls for main house approved
NOTE: 8/27/19 inspection was for waterproofing/backfill/footing drains- observed no egress window @ foundation
had been formed in. Leave area where window/egress will be free of backfill until egress cut in.
Footings Passed
8/6/19 Footings Partial Approval
- House and Garage Footings
Aug 28, 2019 Page (1)
INSPECTION WORKSHEET (BINS-005440-2019)
Checklist Item Status
Piers Failed
Monolithic Slab Failed
Reinforcement in Place Passed
8/6/19 Footings Partial Approval
- House and Garage Footings
Foundation / Wallpour Passed
Reinforcement in Place Passed
2 rows of # 4 rebar horizontal continuous one foot from top and bottom of wall
Footing Dowels or Keyway in place Passed
8/6/19 Footings Partial Approval
- House and Garage Footings
# 4 rebar 48" on center one foot down from top of wall
Foundation Dampproofing Failed
Foundation Waterproofing Passed
8/27/19
Footing Drain Daylight or Sump Passed
8/27/19
Footing Drain Stone - 12 inch width Passed
8/27/19
Footing Drain Stone - 6 inches above footing Passed
Aug 28, 2019 Page (2)
INSPECTION WORKSHEET (BINS-005440-2019)
Checklist Item Status
Footing Drain stone - 6 mil poly Passed
Fabric
Backfill Approval Passed
Plumbing Under Slab Failed
PVC / Cast / Copper Failed
Foundation Insulation Interior / Exterior Passed
Exterior 1/2" blue foam
Rough Grade 6 inch drop within 10 ft.Failed
Poly Under Slab Failed
Aug 28, 2019 Page (3)
Dyer, Charles