ComCheck , •
IPA COMcheck Software Version 4.1.1.0
' A(I Envelope Compliance Certificate
CC - eykr2,(4- . 20Lat
Project Information
Energy Code: 2015 IECC
Project Title: FILE COPY
Location: Glens Falls, New York
Climate Zone: 6a
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
Heidi Underwood Ernest Gailor
Adirondack Enrichment Harlan McGee of North America
413 Bay Road 4000 Silver Beach
REVIEWED FOR Queensbury, NY 12804 Malta, NY 12020
518-584-1300
ENERGY CODE COMPLIANCE ernie@harlan-mcgee.com
Building Area Floor Area
1-Office: Nonresidential 5636
Envelope Assemblies
R-Value Proposed Max.Allowed
Post-Alteration Assembly Cavity Cont. U-Factor SHGC U-Factor SHGC
NORTH.
Exterior Wall 1:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Office], -- -- -- -- -- —
Exemption:Framing cavity not exposed.
EAST
Exterior Wall 3:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Office], -- -- -- -- -- --
Exemption:Framing cavity not exposed.
SOUTH
Exterior Wall 2:Wood-Framed,16"o.c.,[Bldg.Use 1 -Office], -- -- — -- -- --
Exemption:Framing cavity not exposed.
WEST
Exterior Wall 4:Wood-Framed,16"o.c.,[Bldg.Use 1 -Office], -- -- — -- -- --
Exemption:Framing cavity not exposed.
Envelope PASSES
Envelope Compliance Statement
Compliance Statement: The proposed envelope alteration project represented in this document is consistent with the building
plans,specifications, and other calculations submitt-• .ith this permit application.The proposed envelope systems have been
designed to meet the-302-5- e�uirp►n s 07 c -ck Version 4.1.1.0 and to comply with any applicable mandatory
requirements listed h s ti CI�6 t.
SEP 10 2019
TOWN OF QUEENSBURY
BUILDING& CODES
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 1 of 13
. , ._..e•tdiav
Name-Title Signa re Date
J
* 4� f3 , °I'A� .r
L'Lf°,''- d *
Fo 46.
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 2 of 13
COMcheck Software Version 4.1.1.0
Interior Lighting Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title:
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
Heidi Underwood Ernest Gailor
Adirondack Enrichment Harlan McGee of North America
413 Bay Road 4000 Silver Beach
Queensbury, NY 12804 Malta, NY 12020
518-584-1300
ernie@harlan-mcgee.com
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
1-Room 101 (Common Space Types:Lobby-General) 315 0.90 284
2-Room 103(Common Space Types:Classroom/Lecture/Training) 778 1.24 965
3-Room 104(Common Space Types:Classroom/Lecture/Training) 745 1.24 924
4-Room 109(Common Space Types:Corridor/Transition<8 ft wide) 143 0.66 94
5-Room 111 (Common Space Types:Office-Enclosed) 81 1.11 90
6-Room 112(Common Space Types:Classroom/Lecture/Training) 253 1.24 314
7-Room 113(Common Space Types:Classroom/Lecture/Training) 82 1.24 102
8-Room 114(Common Space Types:Classroom/Lecture/Training) 82 1.24 102
9-Room 116(Common Space Types:Classroom/Lecture/Training) 285 1.24 353
10-Room 117(Common Space Types:Office-Enclosed) 117 1.11 130
11-Room 118(Common Space Types:Office-Enclosed) 117 1.11 130
12-Room 121 (Common Space Types:Storage>=50-<=1000 sq.ft.) 101 0.63 64
13-Room 120(Common Space Types:Office-Enclosed) 117 1.11 130
14-Room 119(Common Space Types:Corridor/Transition<8 ft wide) 163 0.66 108
Total Allowed Watts= 3788
Proposed Interior Lighting Power
A B C D E
Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Room 101 (Common Space Types:Lobby-General 315 sq,ft.)
LED 1:LED Panel 40W: 1 4 40 160
Room 103(Common Space Types:Classroom/Lecture/Training 778 sq.ft.)
LED 1:LED Panel 40W: 1 6 40 240
Room 104(Common Space Types:Classroom/Lecture/Training 745 sg.ft.)
LED 1:LED Panel 40W: 1 6 40 240
Room 109(Common Space Types:Corridor/Transition<8 ft wide 143 sq.ft.)
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 3 of 13
A B C D E
Fixture ID: Description/Lamp/Wattage Per Lamp I Ballast Lamps/ #of Fixture (C X D) -
Fixture Fixtures Watt.
LED 1:LED Panel 40W: 1 2 40 80
Room 111 (Common Space Types:Office-Enclosed 81 sq.ft)
LED 1:LED Panel 40W: 1 1 40 40
Room 112(Common Space Types:Classroom/Lecture/Training 253 sq.ft.)
LED 1:LED Panel 40W: 1 4 40 160
Room 113(Common Space Types:Classroom/Lecture/Training 82 sq.ft,)
LED 1:LED Panel 40W: 1 1 40 40
Room 114(Common Space Types:Classroom/Lecture/Training 82 sq.ft.)
LED 1:LED Panel 40W: 1 1 40 40
Room 116(Common Space Types:Classroom/Lecture/Training 285 sq.ft.)
LED 1:LED Panel 40W: 1 5 40 200
Room 117(Common Space Types:Office-Enclosed 117 sq.ft.)
LED 1:LED Panel 40W: 1 1 40 40
Room 118(Common Space Types:Office-Enclosed 117 sq.ft.)
LED 1:LED Panel 40W: 1 1 40 40
Room 121 (Common Space Types:Storage>=50-<=1000 sq.ft. 101 sq.ft.)
LED 1:LED Panel 40W: 1 1 40 40
Room 120(Common Space Types:Office-Enclosed 117 sq.ft.)
LED 1:LED Panel 40W: 1 1 40 40
Room 119(Common Space Types:Corridor/Transition<8 ft wide 163 sq.ft.)
LED 1:LED Panel 40W: 1 4 40 160
Total Proposed Watts= 1520
Interior Lighting PASSES
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2015 IECC requir nts in COMch Versio 4.1.1.0 and to comply with any
applicable mandatory requirements listed in the Inspect' cklist.
�� • n
Name-Title Signature Date
OF NEW y .
CO ct• htu
'ri
nc\-\
S No. 050cp,
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 4 of 13
COMcheck Software Version 4.1.1.0
Exterior Lighting Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title:
Project Type: Alteration
Exterior Lighting Zone 2(Neighborhood business district)
Construction Site: Owner/Agent: Designer/Contractor:
Heidi Underwood Ernest Gailor
Adirondack Enrichment Harlan McGee of North America
413 Bay Road 4000 Silver Beach
Queensbury, NY 12804 Malta, NY 12020
518-584-1300
ernie@harlan-mcgee.com
Allowed Exterior Lighting Power
A B C D E
Area/Surface Category Quantity Allowed Tradable Allowed Watts
Watts/Unit Wattage (B X C)
Total Tradable Watts(a)= 0
Total Allowed Watts= 0
Total Allowed Supplemental Watts(b)= 600
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID: Description I Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Driveway(5 ft2): Exempt: Non-tradable Wattage
Parking area(4 ft2): Exempt: Non-tradable Wattage
Walkway< 10 feet wide(5 ft of walkway length): Exempt: Non-tradable Wattage
Main entry(2 ft of door width): Exempt: Non-tradable Wattage
Total Tradable Proposed Watts= 0
Exterior Lighting PASSES
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the
building plans,specifications, and other calculations submitted with this permit application.The proposed exterior lighting
systems have been designed to meet the 2015 IECC require is in COMchec ersion .1.0 and to comply with any
applicable mandatory requirements listed in the Inspectio a list.
t Cj A/
Name-Title Signature Date
Project Title: Report date: 09/06/19
Data filename: Z:'JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 5 of 13
IP"' COMcheck Software Version 4.1.1.0
li Inspection Checklist
Energy Code: 2015 IECC '
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans and/or specifications provide all ❑Complies
[PR1]1 information with which compliance EDoes Not
can be determined for the building
envelope and document where ['Not Observable
exceptions to the standard are ONot Applicable
claimed.
C103.2 Plans, specifications, and/or EComplies
[PR4]1 calculations provide all information ❑Does Not
with which compliance can be
determined for the interior lighting ['Not Observable
and electrical systems and equipment ;❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations,wattage of
bulbs and ballasts,transformers and
control devices.
C402.4.1 The vertical fenestration area <= 30 ❑Complies
[PR1O]1 percent of the gross above-grade wall ❑Does Not
area.
['Not Observable
❑Not Applicable
C402.4.1 The skylight area <= 3 percent of the ❑Complies
[PR11]1 gross roof area. ❑Does Not
❑Not Observable
ENot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 6 of 13
Section
Footing/Foundation Inspection Complies? Comments/Assumptions
& Req.ID
C303.2.1 Exterior insulation protected against ❑Complies
,[FO6]1 damage, sunlight, moisture, wind, ❑Does Not
landscaping and equipment
maintenance activities. Not Observable
❑Not Applicable
Additional Comments/Assumptions:
•
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 7 of 13
Section -
# Framing/Rough-In Inspection Complies? Comments/Assumptions
& Req.ID
C402.5.1 The building envelope contains a ❑Complies
[FR16]1 continuous air barrier that is sealed in ❑Does Not
an approved manner and either
constructed or tested in an approved ❑Not Observable
manner.Air barrier penetrations are ❑Not Applicable
sealed in an approved manner.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 8 of 13
Section
# Mechanical Rough-In Inspection Complies? Comments/Assumptions
& Req.ID
C402.5.5, Stair and elevator shaft vents have EComplies
C403.2.4. motorized dampers that automatically ❑Does Not
[ME3]3 close. ❑Not Observable
❑Not Applicable
C402.5.5, Outdoor air and exhaust systems have'❑Complies
C403.2.4. motorized dampers that automatically ❑Does Not
3 shut when not in use and meet Not Observable
[ME58]3 maximum leakage rates.Check ❑
gravity dampers where allowed. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 9 of 13
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
C405.2.1 Lighting controls installed to uniformly ❑Complies
[EL15]1 reduce the lighting load by at least ❑Does Not
50%. d
❑Not Observable
❑Not Applicable
C405.2.1 Occupancy sensors installed in ❑Complies
[EL18]1 required spaces. ❑Does Not
:Not Observable'.
❑Not Applicable
C405.2.1, Independent lighting controls installed ❑Complies
C405.2.2. per approved lighting plans and all ❑Does Not
3 manual controls readily accessible and
[EL23]2 visible to occupants. ['Not Observable
❑Not Applicable
C405.2.2. Automatic controls to shut off all ❑Complies
1 building lighting installed in all ❑Does Not
[EL22]2 buildings.
['Not Observable
❑Not Applicable
C405.2.3 Daylight zones provided with ❑Complies
[EL16]2 individual controls that control the ❑Does Not
lights independent of general area [Not Observable
lighting.
❑Not Applicable
C405.2.3, Primary sidelighted areas are ❑Complies
C405.2.3. equipped with required lighting ❑Does Not
1, controls.
C405.2.3. ❑Not Observable
2 ❑Not Applicable
[EL20]1
C405.2.3, Enclosed spaces with daylight area ❑Complies
C405.2.3. under skylights and rooftop monitors ❑Does Not
1, are equipped with required lighting
C405.2.3. controls. ['Not Observable'
3 ❑Not Applicable
[EL21]1
C405.2.4 Separate lighting control devices for ❑Complies
[EL4]1 specific uses installed per approved ❑Does Not
lighting plans.
❑Not Observable
❑Not Applicable
C405.2.4 Additional interior lighting power ❑Complies
[EL8]1 allowed for special functions per the ❑Does Not
approved lighting plans and is
automatically controlled and ['Not Observable
separated from general lighting. ❑Not Applicable
C405.3 Exit signs do not exceed 5 watts per ❑Complies
[EL6]1 face. ❑Does Not
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 ,Low Impact(Tier 3)
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 10 of 13
Section
# Insulation Inspection Complies? Comments/Assumptions
& Req.ID
-C303.1 Building envelope insulation is labeled :❑Complies
(IN10]2 with R-value or insulation certificate ❑Does Not
providing R-value and other relevant
data. ❑Not Observable
❑Not Applicable
C303.2 Above-grade wall insulation installed ❑Complies
[IN7]' per manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
C303.2.1 Exterior insulation is protected from ❑Complies
[IN14]2 damage with a protective material. ❑Does Not
Verification for exposed foundation
insulation may need to occur during ❑Not Observable
Foundation Inspection. Observable,_,
Applicable
C402.2.3 Above-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values.
[IN6]1 ❑Does Not
❑Not Observable
❑Not Applicable
C402.2.6 Radiant panels and associated EComplies
[IN18]3 components, designed for heat ❑Does Not
transfer from the panel surfaces to the
occupants or indoor space are ❑Not Observable
insulated with a minimum of R-3.5. ElNot Applicable
C402.5.1. All sources of air leakage in the ❑Complies
1 building thermal envelope are sealed, ❑Does Not
[IN1)1 caulked, gasketed,weather stripped
or wrapped with moisture vapor- :Not Observable
permeable wrapping material to ❑Not Applicable
minimize air leakage.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 11 of 13
Section
Final Inspection Complies? Comments/Assumptions
& Req.ID
C303.3, Furnished O&M instructions for ❑Complies
C408.2.5. systems and equipment to the ❑Does Not
2 building owner or designated
[FI17]3 representative. ENot Observable
ENot Applicable
C402.5.3 Where open combustion air ducts ❑Complies
[FI51]3 provide combustion air to open ❑Does Not
combustion fuel burning appliances,
the appliances and combustion air ['Not Observable
opening are located outside the ❑Not Applicable
building thermal envelope or enclosed
in a room, isolated from inside the
thermal envelope.Such rooms are
sealed and insulated.
C402.5.8 Recessed luminaires in thermal ❑Complies
[F126]3 envelope to limit infiltration and be IC ❑Does Not
rated and labeled.Seal between
interior finish and luminaire housing. ENot Observable
❑Not Applicable
C405.4.1 Interior installed lamp and fixture EComplies See the Interior Lighting fixture schedule for values.
[F118]1 lighting power is consistent with what ❑Does Not
is shown on the approved lighting :Not Observable
plans, demonstrating proposed watts
are less than or equal to allowed ENot Applicable
watts.
C408.2.5. Furnished as-built drawings for ❑Complies
1 electric power systems within 90 days ❑Does Not
[FI16]3 of system acceptance. ENot Observable'.
ENot Applicable
C408.3 Lighting systems have been tested to ❑Complies
[F133]1 ensure proper calibration, adjustment, ❑Does Not
programming, and operation.
ENot Observable
ENot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 12 of 13
Project Title: Report date: 09/06/19
Data filename: Z:\JOBS\2019\HMNA19-011 413 Bay Road\HMNA19-011-413 Bay Road.cck Page 13 of 13