Loading...
blower door RAJNY onsulfing, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 10/02/2017 Clute Enterprises,Inc. 6 Holden Avenue Queensbury,NY 12804 Inspection Address: 1881 Bay Road, Queensbury NY 12804 Report Number: 1002170 Dear Pam: The Blower Door Test to verify infiltration rate of the subject property was performed on 10/02/2017. This was done to verify mandatory requirements of 2015 IECC Code as amended by the NYS Uniform Code Supplement. This report does not imply that full compliance of above codes has been meet. It's verified the infiltration rates only. GRAJNY Consulting,LLC is pleased to submit the following report. The following data was provided: - Square Footage of the house including conditioned basement=2,184 SF - Volume of the house, including conditioned basement= 18,356 CF Based on above,the following test data was collected: - Infiltration Rate, including conditioned basement at 50 Pascal=885 CFM - ACH50,Actual Changes per Hour at 50 Pascal=885X60/18,356=2.89<3 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, E C E a V E ,StGWl,C7v' - D Vv `y OCT o 3 2017 Stan Grajny, PE RESNET HERS Energy Rater 5609922 TOWN OF QUEENSBURY NYS PE 065406-1 BUILDING&CODES ?...C.-22'� - 20�'+