blower door RAJNY onsulfing, LLC
69 Hayden Point Loop
Diamond Point, NY 12824
518 221-3240
10/02/2017
Clute Enterprises,Inc.
6 Holden Avenue
Queensbury,NY 12804
Inspection Address: 1881 Bay Road, Queensbury NY 12804
Report Number: 1002170
Dear Pam:
The Blower Door Test to verify infiltration rate of the subject property was performed on
10/02/2017. This was done to verify mandatory requirements of 2015 IECC Code as
amended by the NYS Uniform Code Supplement. This report does not imply that full
compliance of above codes has been meet. It's verified the infiltration rates only.
GRAJNY Consulting,LLC is pleased to submit the following report.
The following data was provided:
- Square Footage of the house including conditioned basement=2,184 SF
- Volume of the house, including conditioned basement= 18,356 CF
Based on above,the following test data was collected:
- Infiltration Rate, including conditioned basement at 50 Pascal=885 CFM
- ACH50,Actual Changes per Hour at 50 Pascal=885X60/18,356=2.89<3
The Instruments used for test were provided by the Energy Conservatory Digital Gauge
DG-3 rated accuracy=+/- I%,calibrated minimum once per year.
Thank you for selecting our company. We appreciate the opportunity to be of service.
Please call this office if there are any questions.
Sincerely, E C E a V E
,StGWl,C7v' - D Vv
`y OCT o 3 2017
Stan Grajny, PE
RESNET HERS Energy Rater 5609922 TOWN OF QUEENSBURY
NYS PE 065406-1 BUILDING&CODES
?...C.-22'� - 20�'+