2008-284 TOWN OF QUEENSBURY j
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF 0CCUP-A-N- CY
Permit Number. P20080284 Date Issued: Friday, October 31, 2008
This is to certify that work requested to be done as shown by Permit Number P20080284
has been completed.
Location: 7 BOGART Ct
Tax Map Number. 523400-290-017-0002-037-000-0000
Owner. SCHERMERHORN RESIDENTIAL HOLDINGS, L
TTa Ma Number. 523400-290-017-0002-037-000-0000
Applicant: AMEDORE LAND DEVELOPERS LLC
Owner. AMEDORE LAND DEVELOPERS LLC
This structure maybe occupied as a:
Fireplace By Order of Town Board
Garage Attached TOWN OF QUEENSBURY
Townhouse
Issuance of this Certificate of Occupancy DOES NOT relieve the 1/ 6
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080284 Application Number. A20080284
Tax Map No: 523400-290-017-0002-037-000-0000
Permission is hereby granted to: AMEDORE LAND DEVELOPERS LLC
For property located at: 7 BOGART Ct
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tyne of Construction Value
Owner Address: AMEDORE LAND DEVELOPERS L
7 BOGART Ct Fireplace
UEENSBURY NY 12804-0000 Garage Attached
Q � Townhouse $120,000.00
Total Value $120,000.00
Contractor or Builder's Name/ Address Electrical Inspection Agency
Plans &Specifications
2008-284
1676 sq ft townhouse with 431 sq ft garage and 1 fireplace
$277.74 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,June 24, 2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T 77;7w
r e ay,June 24, 2008
SIGNED BY for the Town of Queensbury.
Director of Building&Code Iforcernent
Check Residential Plan Review: One & Two Family Dwellings
Y /N/A
(2)Full sets of plans
Over 1,500 sq. ft.—Stamped
Design Loads On Plans: 90 Wind Floor Loads 40 psf
50 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
Above/Below grade, 5.7 sq. ft.
Grade,5.0 sq.ft.
24"(h)x 20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofing/Waterproofing Materials On Plans
Foundation Drainage On Plans, if required
6"Drop in 10' Exterior Grade
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where
Required
Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
Stairway Headroom 6' 8' All Stairs 36"Width
(Stair Run and Rise
finder Run and Rise
Spiral Not Allowed From 2° Story
Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
Hall Width, 36"min.
Handrails More Than Four Risers On Open Sides
Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas
Garage Fire Separation
Garage Floor Sloped
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Outside Lowest Sleeping Area,On Every Level&
Interconnected
Soil Test Results,if required
Septic To Well Or Water Line Separation
All Paperwork Signed
+ _ _ _ _ _ _
_ Community Development Office ;
Town of Queerisbury - ,7412 Bnti Roau • Quet isburtl, .fret.c >
Marilym Ryba, Executive Director • David Hatitt, Director f Bui?iiing & co.l<5
C:raio Broton. Zorain Administrator
VVIND01VSCHEDLILE --------------- --
JOB SITE/ADDRESS: C`4, DAT=: b' , I
-- -
OWNER: APPLICATION NCB_: -
WINDOW—
UNIT OR CLEAR CLEAR
WINDOW STOCK ROUGH ROl GH SO FT. OPENING
No.OR WINDOWSQ.FT. )PENING SPECIAL HARDWARE OR
MANUFACTURER NUMBER OPENING OPENING EGRESSICLEAI: — HEIGHT
�(v\ LETTER t`10DEL�T1'PE VENT VIUTH IN INSTRUCTIONS
ON PLAN NAM CALL
WIDTH HEIGHT OPENING INCHES IN
INCHES
A aca "J ;%6-3 7 E
(-05
D 37&5 3� 3i�� (05 � C9• q a 33 �18
-3/1 ill% a,co �,cp
7 Yj q, (o d&1 Ylto 3//
--- - 3
I< Pe- A gl7i H13�q 13/q 5- 913 - 3 Ile 3a1/1
------------------- -- ---
Cori munity Development Office ;
ointt of Queem5buru • 7412 Bail Read • Qire,'raSbrlry, New fork •12804
'.frtnbill Ri ba, EA201tive Director • Daoiii Flatus, Director of Bui?dino & codes
rc?io Brctr'rt, LOttillQ Adrrrirtistratar- ;
BUILDING PERMIT CALCULATION SHEET:
NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS
REQUIRED ACTUAL ----7
ACTUAL LIGHT REQUIRED SQUARE FOOT
AREA OF ROOM IN LIGHT VENTILATION
HABITABLE ROOM SQUARE FEET 8"OF ROOM AREA SQUARE VENTILATION-41% SQUARE OPENING FOR REMARKS
FOOTAGE OF ROOM AREA FOOTAGE EGRESS
rZa
firA
QUESTIONS 7 CALL 761-8256 OR EMAIL
t
codesk,gueensbury.net
VISIT OUR WEBSITE FOR MORE INFORMATION
www_guensbury.net
B 10-LTR 11-20
i
OFFICE USE ONLY
�37 Y !
/ L✓� !4
TAX MAP NO. PERMIT N0. S,1 � �' ,.
!
FEES: PERMIT RECREATION <^ !! �f�h�� ENGINEERING
(If applicable) , c-� ,r � '_�, z`� E�U ,
i._....._.... ................................................................4._0 !. �k' kn:r�iJ.l�Es`s..i
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: ,s -r' C" d1 L"i : OWNER:
ADDRESS:/ (66 W -- i�-l'. 11 b. 1 22'03 ADDRESS:
PHONE NOS. �' _ lU PHONE NOS.
CONTACT PERSON FOR BUILDING &CODES COMPLIANCEW/6"e PHONE: J 6 S `Z5,97
LOCATION OF PROPERTY: `7 6` - ( -I—
SUBDIVISION NAME: tj G
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT p p
APPLY TO YOUR Z �_ W O C w U.
PROJECT O OJ O to = _
w emu_ U., � w ¢ a0U
w o LLC'J ° C) F- j-: p 0M
Z Q Q e- (n N (A O u- u- d = o2S
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE �p
f
0
C�0 2 J
RETAIL-
MERCANTILE
FACTORY OR / b —
INDUSTRIAL " �J
ATTACHED
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: fjA7 s 1cn-
ESTIMATED CONSTRUCTION COST: /Z C! U G U FUEL TYPE:
HEAT TYPE: *HOW MANY FIREPLACE(S):___1___AND/OR WOODSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE? 010
PROPOSED USE OF BUILDING OR ADDITION:'To ajA Ci Z W,,0 ^-^ W( Z-F"I( ►3a .mac
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
B 3.LGL 11.(
Town o{n,.,,,,n.,;22JY1/ ■ Ciim if"illI ll= . 7A ) 12—, D-- J f*'%- '--L------ AT. 41—n
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? �
ARE THERE EASEMENTS ON PROPERTY?
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.}
Signed (1'V
Director of Building &Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
0 ,
, 10 , 0
Permission is hereby granted to the above ; This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury. 01
o Application:
,
,
,
,
11
, ,
11
I ,
, ,
, ,
, 0 , ,
BUILDING & CODES APPROVAL01
ZONING APPROVAL
1 ,
, 0
, , ,
,
, ,, ,
DATE % DATE 11
,
QUESTIONS? CALL 761.8256 OR EMAIL
codes(ftueensburv.net
Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION
Operating Permit Issued: Yes No www.aueensbu!y.net
Occupancy Type:
Construction Classification:
Assembly Occupancy Limit:
Special Conditions:
Town of Queensbunj - Community Development Office - 742 Bay Road, Queensbunf, NY 12804
MAP REFERENCE:
HAVILAND ROAD SUBDIVISION /'e
BY.' VAN DUSEN&STEVES /�
DATED: OCTOBER 14, 2005 �
LAST.'REVISED MARCH 16, 2006 �1:6 a�
//
LOT 1
LOT 38
�c
y y y y x
n
b
t=►
COMMERCIAL LOT 2 '` b
Q 7 1�2
STORY
WOOD cri
TOWN FCL
IRF y
CONC.
8 ��47"E ASPHALT
W y 743.2p
44.17' A
44
�o ! IRF
1 1/2 STORY
WOOD F
( TOWNH US£� CO„TCRM
31.74'
WETLANDS
y A5PHALT
COMMERCIAL LOT 3ISI �.
LOT 37 o a,
_+ y IRF a 11,806. 17 sq. ft.
0.27 acres
N 80 Gs Sg, M
IRF 117.63- w
IRF
o O
N78 24 26O W
71
C.
LOT 35 LOT 36 u
H.O.A. Q,
K o LANs
Date. October 20, z008
Du S Map of a Survey made for
'UNAU7li0WT.ID ALTERATION OR ADDITION TO A SURVEY
YAP BEARING A LICENSED LAND SURVEYORS SEAL 4 A Scale 1 =20
VIOLATION OF
SECTION 7209.SUB-OM"Z OF THE
...rrr''�VV� te -ves NEW YORC STATE EDUCATION ORIGINAL
LAW Mitchel D. Thompson
ONLY COPIES FROM THE OF THE
OF THIS SURVEY
►INKED WITH AN ORIGIN&CONSIDERED
OF TIE LAND SURVEYORS
'`�`�G°"�`DwmcNs°� ' * Gloria Thompson
CERTOICATIONS INDICATED 11QtECN 9GNIY THAT
'On SURVEY WAS PREPARED W ACCORDANCE YATH THE
Land surveyors BY THE 000E OF PRACTICE FOR LAND SURVEYORS PROFESSIONAL
ADOPTED LOT 37
BY THE NEW YORK STATE ASSOCIATION OF PROFE590NAL
LAND SURVEYORS,SAID CER7N7CA11RVE IS P RUN ONLY
TO THE PERSON FOR WHpI THE SURVEY IS PREPARED.AND
ON NC AM L To THE STIR CONFUSE HEREON. TALAND Haviland Road Subdivision
169 Haviland Road Queensbury, New York 12804 "�"'G''""°`E"°'"°DNS1171A71DN LISTED HEREON.""°
TO INC ASSIGNEES OF THE LENDING WSTI7UTION.'
Town of Queensbury, Warren County, New York Mitchel
(518) 792-8474 New York Lic. No. 50135 1 1 NO. DATE DESCRIPTION DWG. NO. 0514G-37
-- ----------
lre Mar-Qhal's Office
n. of Queensl7isry - 742 Bay Road • Queensburq, Neu York -12804
Michael' Valmer. Fire Warshal- Gary.15617mmi, 0epity Fire Alarshal
---------......---------
APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS
Application is hereby made to the Building &Codes Office for the issuance of a Building& Use Permit
pursuant to the New York State Fire Prevention&Building Code. The applicant or owner agrees to comply
with all applicable laws, ordinances,regulations,and all conditions that are part of these requirements and
also will allow all inspectors to enter premises to perform required inspections.
IMPORT ANT.NOTE T APPLIC414T. ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED.
OWNER: INSTALLER/BUILDER: C,0
ADDRESS: Al-A ADDRESS:
PHONE Nos. PHONE NOS.
LOCATION OF PROPERTY, 144- SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION ANDIOR INSTALLATION:
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: —M—t PHONE,
✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL
INFORMATION
STOVE
FIREPLACE INSERT
FIREPLACE,FACTORY BUILT*
FIREPLACE MASONRY
FURNACE(GARAGE ONLY)
*IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. NJ< f
LISTED BY: NUMBER:
QUESTIONS?
CJ.�LL 7614205 or 761-8206
CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL:
fl remarshal(M-9 u eens bury.net
MASONRY" CHECK ONE ✓ --VISIT OUR INESSITE
TILE STEEL SIZE IN FOR MORE INFORMATION
I INCHES www.gueensbury.net
✓
FLUE CHECK ONE DOUBLE TRIPLE WALL INSULATED DIRECT VENT CHIMNEY
WALL LINER
CHIMNEY MATERIAL CHECK ONE ✓
**IF NON-MASONRY,PLEASE PROVIDE. MANUFACTURER NAME. MODEL NO.
ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR
MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED
INSPECTIONS.
Final Survey Inspection
Dept. of Community Development
Town of Queensbury
742 Bay Road
Queensbury,NY 12804
Date received:
t
NAME:
LOCATION:
PERMIT#:
Final Survey Plot Plan
Auvroved Denied
The attached final
survey has been
received by the
Dept.of
Community
Development.
Upon review th
. survey
CraikZre,4n,Zoning Administrator
Notes:
L:\.SueHemingwa)ABuilding.Codes.Inspection.FORMS\Final Survey
Zoning Administmtor doc
Queensbury Building & Code Enforcement - Residential Final In Iction
Office No. (518)761-8256 Arrive: I `' am p /-Deplact: am/pm
Date Inspection request receiv : Inspect is Initials: �—�
p 4
NAME: PERMIT#:
LOCATION: - DATE: rw
TYPE OF STRUCTURE:
Comments:
Yes o NIA
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors IV
Handrail 4 or more risers
Guards at stairs decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade awa from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed propped
Gas Logs in Sealed o I re
Final Electrical
Final Survey Plot Plan
Arc fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer De t. Ins coon Sticker qfog
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Forrn_revised_100405.doc;Revised
January 7,2008;Revised 6/2601
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No.(518)761-8256 Arrive: am/pm epart: am/pm
Date Inspection request received: Inspector's In tials: j
NAME: PERMIT#: /
LOCATION: _ DATE:
TYPE OF STRUCTURE:
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/'B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
PIatform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s . ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Tern 110
Enclosed Stairs Sheetrock Underside minimum Yz"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
ara a fireproofing/3/a hour fire door/door closer
uct work Sealed properly
Gas Logs in Sealed or Glass Enclosure /I/ 14_
mal Electrical
Final Survey Plot Plan �����"4L—
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required `
Flood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
f'
r
Foundation Inspection Reportsable
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
oundation Waterproofin
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspe quest received:
Queensbury Building & Code Enforcement Arrive: _ am/p part: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT #:
LOCATION: ��lT-`r/J/c' INSPECT ON: T&z o
TYPE OF STRUCTURE:
Y N N/A
-Rough Plumbing Nail Plates
Plumbing Vent Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every_100 feet change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
/ Head
50 P.S.I for 15 minutes
Insulation Residential Check I Commercial Check
Proper Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated s aces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct to e
COMMENTS:
LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/p art: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: � �2
NAME: A,-\ e� PERMIT #: dv" ,q
LOCATION: T INSPECT ON: Z
TYPE OF STRUCTURE:/
Y N NIA
Rough Plumbing / Nail Plates
Plumbing Vent/Vents in Place
1 Y2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping &
Air/Head
50 P.S.I for 15 minutes
insulation/ Residential Check/Commercial Check r�G L JA)
T ek or Similar Exterior Sealant
Pro er Vent, Attic Vent V
Door/Window Sealed No Insulation
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
r
Framing Airesiopping Inspection Report 1/
Officil No. (518) 761-8256 Date Ins request deceived:
Queensbury Building&Code Enforcement Arrive: am/ LI.Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: _, '�; - PERMIT# � �
LOCATION: INSPECT ON: L
TYPE OF STRUCTURE:
Y N NIA COMMENTS:
Framing
ttic A ss 22" x 30" minimum P
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
F' a separation 1, 2, 3 hour
ire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side i4 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
/20 in. OM
5.7 sf above/below grade
5.0 sf grade .0/ 1
LABuilding&Codes Fortes-01-Muilding&Codesllnspedion FonnsTranft Firestop pedion Reportdoc Revised January 7,2M
Job Truss Truss Type Oty Ply 7-11 Bogart I Amedore
E8060175 n-R COMMON 1 1 OS:1,UNITS:0.5 JLFIDJR 114404931
Job Reference(optional
PROSuild East LLC,Kingston,NY 12401,Jennifer Fichter 7.050 a May 22 2008 MTek Industries.Inc.Thu Aug 21 15:22:44 2008 Page 1
1 5-2-12 1 10-2-0 16-11-7 1 18 10-4 1 26-6 0
5-2-12 4-11-4 6-9-7 1-10-13 7-7-12
CONDITION:TAPER B.C.STARTING AT 0-1-0 LEFT END
TO 0.0-0 AT JOINT 9. sxs LUMBER AND CONNECTOR PLATES
s \ TO BE CUT CLEANLY AND ACCURATELY
AND THE REMAINING PLATE MUST BE
FULLY EMBEDDED AND UNDISTURBED.
ADD 2 X 4 SPF NO.2
OR BETTER,CUT TO FIT TIGHT
u.ao hz sx^' sa
3-0-0 3
9 6
2
I
\J
Bxt1��
�i
ti
c ® --54 sxs' ,. 16"X36" 16"X24"
sxn II a ,5 12 11 19 ,o 0
M=
5-2-12 10-2-0 16.11-7 18-10-4 26-6-0
5-2-12 4-11-4 6-9-7 1-10-13 7-7-12
Plate Offsets X Y: 1:0-3-8 Ed a 3:0-1-4 0-1-8 4:0-0-12 0-5.12 5:0-2-B Ed a 6:0-1-12 0-2-0 10:0-1-12 0-2-0
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Ildefl Ud PLATES GRIP
TCLL 50.0 10) Plates Increase 1.15 TC 0,93 Vert(LL) -0.11 10-12 >999 360 MT20 197/144
(Ground Snow=6 Lumber Increase 1,15 BC 0.66 Vert(TL) -0.19 10.12 >999 240
TCLL 10.0 BCLL 0.0 Rep Stress Ina YES WB 0.66 Horz(TL) 0.04 8 n/a nla
'
BCDL 10.0 Code IRC2003ITP12002 (Matrix) Wind(LL) 0.01 1-13 >999 240 Weight:171 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF No.2*Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, (P)
4-5.2 X 6 SPF No.2,5-7:2 X 4 SPF 240OF 2.0E and 2-0-0 oc purlins(6-0-0 max.):4-5.
BOT CHORD 2 X 4 SPF No.2 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing.
WEBS 2 X 4 SPF No.2*Except` WEBS 1 Row at midpt 4-10,5-10,6-9
3-13:2 X 4 SPF Stud,7-8:2 X 6 SPF No.2 with 2 X 4 SPF No.2 with 2-12d(0.1 31"x3.251 nails and cross brace spacing of
SLIDER Left 2 X 8 SYP No.2 3-10.6 20-0.0 oc.
REACTIONS (Ib/size) 1=1648/0-3-8,9=1440/0-3-8,8=915/0-3-8
Max Horz 1=201(LC 7)
Max Grav 1=2128(LC 2),9=1591(LC 3),8=1168(LC 3)
FORCES (lb)-Maximum Compression/Maximum Tension
TOP CHORD 1-2=-2453175,2-3=-1924/102,3-4=1757/187,4-5=-616/167,5-6=-1018/260,6-7=-1113/90,7-8=1090/72
BOT CHORD 1-14=94/1460,13-14=-94/1460,13-15=-94l1460,12.15=-94l1460,11-12=53/1072,11-16=-53/1072,10-16=53/1072,9.10=-30/459,8.9=103/592
WEBS 3-13=0/207,3-12=-614/144,4-12=-32/731,4-10=-877/40,5-10=-150/150,6.10=-34/1032,6-9=1483/97,7-9=-140/258
NOTES
1)Wind:ASCE 7-02;90mph;TCDL=6.Opsf;BCOL=6.Opsf,h=17ft;Cat.II;Exp B;enclosed;MWFRS(low-rise)and C-C Exterior(2)zone;cantilever left and
right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.33 plate grip DOL=1.33
2)TCLL:ASCE 7-02;Pg=65.0 psf(ground snow);Pf=50.0 psf(flat roof snow);Category 11:Exp B;Partially Exp.;Ct=1.1
3)Unbalanced snow loads have been considered for this design.
4)Provide adequate drainage to prevent water ponding.
5)This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
6)The Fabrication Tolerance at joint 7=16
7)•This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3.6.0 tall by 1-0-0 wide will fit between the bottom
chord and any other members.
8)This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. ! OF NEWt-
9)Design assumes 4x2(flat orientation)purlins at oc spacing indicated,fastened to truss TC wl 2-10d nails. X1` N l�
10)Warning:Additional permanent and stability bracing for truss system(not part of this component design)is always required. (�� fiG 05.l�
LOAD CASE(S) Standard
r
ATTACH 1/2"PLYWOOD OR OSB GUSSET(15l32"APA RATED SHEATHING 32/16 EXP 1) �
TO EACH FACE OF TRUSS WITH 10d(3.0"X.131")NAILS DRIVEN THRU BOTH SHEETS rn UJI
OF PLYWOOD AND CLINCHED PER THE FOLLOWING NAIL SCHEDULE: LU
2 x 3's-1 ROW @ 0-4-0 O.C.2 x US-3 ROWS @ 0-4-0 O.C. Q
2x4's-2 ROWS @0.4-0O.C.2 x 8's AND LARGER-4 ROWS @0-4.0 O.C. Q �O 077�6
Ahh
NAILS TO BE DRIVEN FROM BOTH FACES. STAGGER SPACING FROM FRONT TO BACK FACE FOR A 'T
NET 0-2-0 O.C.SPACING IN THE MAIN MEMBER. USE A MIN.0-3-0 MEMBER END DISTANCE. op)zs sli o
August 21,200
A W.BRMAr,-Vefjy design parametrrsandRRA i+f0783ONTwsAmarr,=ED RE,FERENczPAGEMII-7473 BEFORE USE.
Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown iTe k
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding
fabrication,quality control,storage,delivery,erection and bracing.consult ANSI/TPII Quality Criteria.DSB-89 and BCSII Building Component 14515 N.Outer Forty,Suite x300
Safety Information available from Truss Plate Institute.583 D'Onofrio Drive,Madison,WI 53719. j Chestertieltl.MO 63017
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: 2- o 4
Queensbury Building &Code Enforcement Arrive: am/pm �lD Dee,part: \ am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: /f /
NAME: PERMIT
LOCATION: �� �;5 ArT_ INSPECT ON: -37
TYPE OF STRUCTURE: 1�
Y N N/A
R2Wh Plumbing/Nail Plates
Plumbin Vent l Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/&I.
�'-5 P. �hWinnection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Re
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm part: " - am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#: -2PI
LOCATION: -� INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N NIA COMMENTS:
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
jVvCKo-r13olts or less on center
Ice and water sh' d 24 inches from wall
ire separatien1l, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side i4 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-OMBuilding&Codesvnspedion ForrnslFraming Firestopping Inspection Reportdoc Revised January 7,2008
Framing I Firestopping Inspection e rt
Office No. (518)761-8256 Date Inspection request received:Queensbury Building &Code Enforcement Arrive: am/pm _part: `� am/pm
742 Bay Road, Queensbury, NY 12&M Inspector's Initials: ..
NAME: f PERMIT#:
LOCATION: INSPECT ON: -
TYPE OF STRUCTURE: v
Framing Y N WA COMMENTS:
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D naus each side
Draft stopping 1,000 sq. ft. floor trusses
or less on center
Ice and waters Id 24 inches from wall ` �4�1' kill'-
ration 1, 2, 3 hour
Fire wail 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 518 inch Type X �f�
Garage side 518 inch Type X l
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-01-MuNding&Codes\inspecdon Forms'Frarrang Fi estoming Inspection Reportdoc Revised January 7,2008
Foundation Inspection Report
Office No.(518)761-8256 Date Inspectio req v 7 l
Queensbury Building&Code Enforcement Arrive: p Depart:
742 Bay Rd.,Queensbury,NY 12804 Inspector s Initial . y
NAME: ,Ys�l° P #:
LOCATION: INSPECT ON: ! G
TYPE OF STRUCTURE:
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
inforcement in Place
e ay in place
oundation Waterproofm
Footin li t or Sump
12 inch width
6 inches above footing
et areas under slab
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report 1 .
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:
pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: )4keo ,��''�- PERMIT#:
LOCATION: INFECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the oncrete.
s r this on site.
Foundation/Wallpour
Rem orcement in Place 2,
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofmg
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received: - o e
Queensbury Building&Code Enforcement Arrive: am/pm Dep am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: _ 0
LOCATION: 11 - INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
s or . se on site.
Foundatioft/Wallpour hU 12e5."Y" '
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspec Lion Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspectio t ed
Queensbury Building&Code Enforcement Arrive: �� Depart:
742 Bay Rd.,Queensbury,NY 12804 Inspector s Initi
NAME: RMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUATIURIE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofmg
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Fors\Building&Codes\Inspecdon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/pm part: am/pm
Date Inspection reques received: Inspec is Initials:
NAME: Yam. PERMIT#:
LOCATION: 2 DATE:
TYPE OF STRUCTURE:
Comments"
Yes No N/A
,C_Building Number Address visible from road yr Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake rV 0 L)
3 inch Plumbing-Vent through roof minimum 6 inches 0—
��
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handica Ram Compliant
from Grade awa foundation 6 inches with 10 feet
6 inch clearance to silt plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertt ht
Safety glazing/Window in stairwells sR§ty glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Batter
backu
Attic aocess 30 inches x 22 inches x 30 inches_(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, i .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater oll2rating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%'Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed property
Gas Loge in Sealed or Glass Enclosure
Final Electrical
Final Surve Plot Plan
Are Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required 4
Oka to issue C/C or C 10 Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc;Revised
January 7,2008;Revised 6/26/08
r
REScheck Software Version 4.1.3
Compliance Certificate
Project Title: Townhomes at The Havilands
Report Date:06/02/08
Data filename: K:\RESCHECK\havilands\7Bogart.rck
Energy Code: 2007 New York Energy Conservation
Construction Code
Location: Warren County, New York
Construction Type: Multifamily
Heating Type: Non-Electric
Glazing Area Percentage: 8%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Contractor:
7 Bogart Ct. William Balogh
Queensberry,NY 12804 Amedore Homes Inc.
1900 Western Avenue
Albany,NY 12203
518-456-1010
wbalogh@amedorehomes.com
Compliance�Passes
Compliance:40.3%Better Than Code Maximum UA:494 Your UA:295
Gross Cavity Cont. Glazing UA
Assembly Area or R-Value R-Value or ■..
Perimeter U-Factor
Ceiling 1:Raised or Energy Truss 1676 30.0 0.0 54
Wall 1:Wood Frame, 16"o.c. 1602 19.0 0.0 86
Window 1:Wood Frame:Double Pane with Low-E 113 0.350 40
Door 1:Solid 56 0.280 16
Door 2:Glass 8 0.310 2
Basement Wall 1:Solid Concrete or Masonry 1406 11.0 0.0 97
Wall height:7.8'
Depth below grade:6.0'
Insulation depth:7.8'
Furnace 1:Forced Hot Air90 AFUE
Air Conditioner 1:Electric Central Air13 SEER
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted
with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction
Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her
knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code.
Name-Title Signature D e
pF NEWyo
�. STEp�'�
\ ' 45% y
FESSI��A
Project Title: Townhomes at The Havilands Report date: 06/02/08
Data filename: K:\RESCHECK\havilands\7Bogart.rck Page 1 of 4
CREScheck Software Version 4.1.3
NJ( Inspection Checklist
Date: 06/02/08
Ceilings:
❑ Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
Above-Grade Walls:
❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1:Solid Concrete or Masonry,7.8'ht/6.0'bg/7.8'insul,R-11.0 cavity insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1:Solid,U-factor:0.280
Comments:
❑ Door 2:Glass,U-factor:0.310
Comments:
Heating and Cooling Equipment:
❑ Furnace 1:Forced Hot Air:90 AFUE or higher
Make and Model Number:
❑ Air Conditioner 1:Electric Central Air: 13 SEER or higher
Make and Model Number:
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation.
Vapor Retarder:
❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner
that achieves the rated R-value without compressing the insulation.
Duct Insulation:
Project Title:Townhomes at The Havilands Report date:06/02/08
Data filename: K:\RESCHECK\havilands\7Bogart.rck Page 2 of 4
Supply ducts in unconditioned attics or outside the building are insulated to at least R-11.
Return ducts in unconditioned attics or outside the building are insulated to at least R-6.
Supply ducts in unconditioned spaces are insulated to at least R-11.
Fl Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements.
Duct Construction:
All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or
tapes.Tapes and mastics are rated UL 181A or UL 18113.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
Lj The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone.
Electric Systems:
Separate electric meters exist for each dwelling unit.
Fireplaces:
Fireplaces are installed with tight fitting non-combustible fireplace doors.
Ll Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York
State,the Residential Code of New York State or the New York City Building Code,as applicable.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is part of a circulating system.
Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
Lj HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Project Title:Townhomes at The Havilands Report date: 06/02/08
Data filename: K:\RESCHECK\havilands\7Bogart.rck Page 3 of 4
Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Project Title: Townhomes at The Havilands Report date: 06/02/08