JB191099.0024.Field Density Testing.2019-08-15.Rpt.0024FIELD DENSITY TEST REPORT
Report Number:
Service Date:
Report Date:
Task:
JB191099.0024
08/15/19
10/01/19
594 Broadway
Watervliet, NY 12189-3709
518-266-0310
Client
Ellsworth & Son Excavating, Inc.
Attn: Ruben Ellsworth
76 Ellsworth Lane Ext.
Large George, NY 12845
Apex Capital, LLC
59 West Mountain Road
Queensbury, NY 12804
Project
Project Number: JB191099
Lab Test Data
(%)
Compaction
Project Requirements
(%)
Content
Water
No.
Mat.
Material Information
Density
Max. Lab
(%)
Content
Water
Optimum
Ref. No.
Proctor Laboratory
Classification and Description (pcf)Test Method
Min 95.01109.411.6JB191099.0023B F-M-C SAND, trace silt and fine
gravel
ASTM D1557
2 131.28.1JB191099.0002B M-F-C SAND, Little F-C Gravel,
trace cobble and silt
ASTM D1557
3 135.56.9JB191099.0002C M-F-C SAND, Little F-C Gravel,
trace cobble and silt
ASTM D1557
4 122.511.4JB191099.0001B M-C-F SAND, Little F-C Gravel,
trace silt
ASTM D1557
Field Test Data
No.Test Location Elev.No.
Test Lift /Mat.Depth Density
Probe Wet
Content
Water
(%)
Content
Water
Density
Dry
(%)
Percent
Compaction
(in)(pcf)(pcf)(pcf)
Building Interior
1 10ft inside Southeast corner -1TOW 1 8 108.3 4.0 3.8 104.3 95.3
2 10ft inside Northeast corner -1TOW 4 8 125.7 6.3 5.3 119.4 97.5
3 10ft inside Northwest corner -1TOW 1 8 112.9 3.5 3.2 109.4 100.0
4 Middle of building -1TOW 2 8 133.9 9.1 7.3 124.8 95.1
5 10ft inside Southwest corner -1TOW 3 8 138.4 4.0 3.0 134.4 99.2
Comments:
Datum:TOW= Top of wall Std. Cnt. M:Std. Cnt. D:6551962
Test and/or retest results on this report meet project requirements as noted above.
Last Cal. Date:Model:Make:S/N:21608 Troxler 3430 01/30/2019
Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Services:
Reported To:
Contractor:
Earthwork foreman
M. McHenry
Materials Group Manager
Report Distribution:
(1) Ellsworth & Son Excavating, Inc., Ruben
Ellsworth
Reviewed By:
Dente Group - A Terracon Co. Rep.: Samuel Schmitz
ASTM D6938Test Methods:
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CR0007, 11-16-12, Rev.7 Page 1 of 1