concrete testing report e QCQA c 0 L\ r ap\C\ Concrete Field Observation Reports Alt kot:, Klin DRILLING & TESTING SERVICES Project: Stewarts-Queensbury,NY Report No.: C-081219 Client: Stewart's Shop Date: 8/12/2019 Contractor: KM Masonry Job No.: 19-078 Concrete Supplier: Pallette Mix No.: 40001 Weather: Sunny;Breezy Air Temp.:AM PM 84 General Placement Location: Building Perimeter Footings Sheet: 1 of 1 Time Test Data Air i Unit Conc. Load Ticket Truck Cubic Water Start End Slump Content Weight Temp No. No. No. Yards Added Batched Discharge Discharge Tested In. % Pcf (F.) Specimen Set No./Remarks 1 833802 4525 10 2:03 2:40 I 2:55 2:44 4.25 6.0 85 Set 1(6 Cylinders) 2 833803 4913 10 2:22 2:56 3:10 Remarks: Cubic yards placed: 20 Rejected: TECHNICIAN: Tod Kobik COMPRESSIVE STRENGTH DATA Set Lab Cylinder Date Age Load Fracture Compressive No. No. Diameter Area Tested (days) (lbs.) Type Strength(psi) 1 5698 6.0 28.27 8/19/2019 7 100,640 5 3,560 5699 6.0 28.27 8/19/2019 7 104,160 5 3,680 5700 6.0 28.27 9/9/2019 28 130,940 5 4,630 5701 6.0 28.27 9/9/2019 28 115,010 4 4,070 5702 6.0 28.27 9/9/2019 28 126,080 5 4,460 5703 6.0 28.27 9/9/2019 28 121,030 5 4,280 Specification Requirement at 28 days 4,000 Cylinder Size:6"x 12"unless otherwise noted Slump in accord with ASTM C-143 FRACTURE TYPE: 1 /Sampled in accord with ASTM C-172 Air in accord with ASTM C-231 1=Cone Both Ends Tested in accord with ASTM C-39 Unit Wt.in accord with ASTM C-138 2=Cone 1 End Tod Kobik Cast in accord with ASTM C-31 Temp in accord with ASTM C-1064 3=Columnar QC/QA Laboratories Inc. 4=Diagonal Fracture Vice-President 5=Side Fracture 6=Side Fracture(2) 877 Route 4S-Schuylerville,NY 12871-Phone:(518)372-4067-Fax:(518)507-6113 QCQA INSPECTOR'S DAILY REPORT 1111 Date: 8/12/2019 DRILLING & TESTING SERVICES S M T W T F S Project: Stewart's Shop-Queensbury, NY Day X Client: Stewart's Shops Weather rialt Clear Overcast Rain Snow X Bldg./Area Building Perimeter Footings Temp. To 32 32-50 50-70 70-85 85 ui X Contractor: Wind Still Moderate MI Report No. X QCQA Proj.# 19-078 Humidity Dry Moderate Humid I-081219 X OBSERVATIONS The undersigned representative of QCQA Labs was on site at the above project as requested for bearing grade evaluation for the building perimeter footings.We understand the footings have been designed using an allowable soil bearing pressure of 2,000PSF.The exposed bearing soils appeared to consist of native sand with some intermixed gravel. Based upon our observation of the exposed bearing grades, it is our opinion the soils are adequate for the design soil bearing pressure of 2,000PSF. See Also (Test Report Nos.): Inspector Tod Kobik, P.E. 877 Route 4S -Schuylerville, NY 12871 - ph (518)372-4067 -fax(518)507-6113 QC QA 877 Route 4S Schuylerville, NY 12871 W Phone: (518)372-4067 DRILLING & TESTING SERVICES Fax: (518)507-6113 QCQA Reinforcing Steel Inspection Report Project No.: 19-078 Date: 8/12/2019 Project Name: Stewarts-Queensbury, NY Report#: R-081219 Contractor: QCT: Tod Kobik Drawing Used for Inspection: Al and AlA Dwg. Approval Date: Type of Placement: Walls Footings X Slabs Other Placement Location: Building Perimeter Footings OK NG NA Inspection Item X 1. Correct bar diameter, length and spacing per approved shop drawing X 2. Correct steel grade X 3. Adequate clearance from earth, forms and cover X 4. Adequate splice laps, lengths and staggered X 5. Bends: correct radius, no sharp bends from heating X 6. Additional bars at corners, intersections, openings, etc. X 7. Free of LOOSE mill scale, rust X 8. Free of oil, mud, hardened concrete, tags, form coating X 9. Dowels where shown and securely tied in-place X 10. Beams/slabs spliced near supports for bottom steel, near midspan for top steel X 11. No kinked or bent tension steel X 12. All reinforcing steel securely tied and supported to prevent displacement during pour X 13. Approved chairs and spacers installed BEFORE pour X 14. No welding on reinforcing steel without approval of Structural Engineer X 15. Adequate spaces for proper placement of concrete 16. No bending or displacement due to embedded items or boxes unless approved by X Structural Engineer X 17. No cutting to avoid obstructions except as approved by Structural Engineer X 18. Stirrup corners tight to vertical and not sloped to make tight Notes: 1)All NG items are to be reported to Contractor immediately via inspection report 2)NA= Not Applicable Remarks: Tod Kobik. QC/QA Laboratories, Inc. PROMPT SERVICE. FAIR PRICES. ACCURATE RESULTS. Vice-President g/Forms/Concrete/Rebar Inspection/Rebar Insp-8.2.07 QCQlhA Concrete Field Observation Report DRILLING & TESTING SERVICES Project: Stewarts-Queersbury,NY Report No.: C-081319 Client: Stewart's Shop Date: 8/13/2019 Contractor: KM Masonry Job No.: 19-078 Concrete Supplier: Pallette Mix No.: 40001 Weather: Overcast;Humid Air Temp.:AM PM 71 General Placement Location: Foundation Walls:(Entirety) Sheet: 1 of 1 Time Test Data Air Unit Conc. Load Ticket Truck Cubic Water Start End Slump Content Weight Temp No. No. No. Yards Added Batched Discharge Discharge Tested In. _ % Pei (F.) Specimen Set No./Remarks 1 833844 4905 10 3:07 4:00 4.35 4:05 3.5 7.0 i 88 Set 1(6 Cylinders) 2 833845 4913 10 3:57 4:40 Remarks: Cubic yards placed: 20 Rejected: TECHNICIAN: Ben Gifford COMPRESSIVE STRENGTH DATA Set Lab Cylinder Date Age I Load Fracture Compressive No. No. Diameter Area Tested (days) I (lbs.) Type Strength(psi) 1 5730 6.0 28.27 8/20/2019 7 ' 97,970 2 3,470 5731 6.0 28.27 8/20/2019 7 104,780 5 3,710 5732 6.0 28.27 9/10/2019 28 131,910 3 4,670 5733 6.0 28.27 9/10/2019 28 128,110 5 4,530 5734 6.0 28.27 9/10/2019 28 136,270 5 4,820 5735 6.0 28.27 9/10/2019 28 121,570 5 4,300 Specification Requirement at 28 days 4,000 Cylinder Size:6"x 12"unless otherwise noted Slump in accord with ASTM C-143 FRACTURE TYPE: --'�-' Sampled in accord with ASTM C-172 Air in accord with ASTM C-231 1=Cone Both Ends Tested in accord with ASTM C-39 Unit Wt.in accord with ASTM C-138 2=Cone 1 End Tod Kobik Cast in accord with ASTM C-31 Temp in accord with ASTM C-1064 3=Columnar QC/DA Laboratories Inc. 4=Diagonal Fracture Vice-President 5=Side Fracture 6=Side Fracture(2) 877 Route 4S-Schuylerville,NY 12871-Phone:(518)372-4067-Fax:(518)507-6113 QCQA 877 Route 4S Schuylerville, NY 12871 ir;c. WO Phone: (518)372-4067 DRILLING & TESTING SERVICES Fax: (518)507-6113 QCQA Reinforcing Steel Inspection Report Project No.: 19-078 Date: 8/13/2019 Project Name: Stewarts-Queensbury, NY Report#: R-081319 Contractor: KM Masonry QCT: Ben Gifford Drawing Used for Inspection: Foundation#A1 Dwg.Approval Date: 8/3/2019 Type of Placement: Walls X Footings Slabs Other Placement Location: Foundation Walls (Entirety) OK NG NA ' Inspection Item X 1. Correct bar diameter, length and spacing per approved shop drawing X 2. Correct steel grade X 3.Adequate clearance from earth, forms and cover 4.Adequate splice laps, lengths and staggered X 5. Bends: correct radius, no sharp bends from heating X 6. Additional bars at corners, intersections, openings, etc. X 7. Free of LOOSE mill scale, rust X 8. Free of oil, mud, hardened concrete, tags, form coating X 9. Dowels where shown and securely tied in-place X 10. Beams/slabs spliced near supports for bottom steel, near midspan for top steel X 11. No kinked or bent tension steel X 12. All reinforcing steel securely tied and supported to prevent displacement during pour X 13. Approved chairs and spacers installed BEFORE pour X 14. No welding on reinforcing steel without approval of Structural Engineer X 15. Adequate spaces for proper placement of concrete 16. No bending or displacement due to embedded items or boxes unless approved by X Structural Engineer X 17. No cutting to avoid obstructions except as approved by Structural Engineer X 18. Stirrup corners tight to vertical and not sloped to make tight Notes: 1)All NG items are to be reported to Contractor immediately via inspection report 2)NA= Not Applicable Remarks: Tod Kobik. QC/QA Laboratories, Inc. PROMPT SERVICE. FAIR PRICES. ACCURATE RESULTS. Vice-President g/Forms/Concrete/Rebar Inspection/Rebar Insp-8.2.07 Q C QA 877 Route 4S Schuylerville, NY 12871 FBTPR:C5, d WM* Phone: (518)372-4067 "" - Fax: (518)507-6113 DRILLING & TESTING SERVICES QCQA Reinforcing Steel Inspection Report Project No.: 19-078 Date: 8/22/2019 Project Name: Stewarts-Queensbury, NY Report#: R-082219 Contractor: KM Masonry QCT: Ben Gifford Drawing Used for Inspection: No Drawing Provided Dwg.Approval Date: Type of Placement: Walls Footings Slabs X Other Placement Location: S.O.G.: Entire Building Excluding Patio OK NG NA Inspection Item X 1. Correct bar diameter, length and spacing per approved shop drawing X 2. Correct steel grade X 3. Adequate clearance from earth, forms and cover X 4.Adequate splice laps, lengths and staggered X 5. Bends: correct radius, no sharp bends from heating X 6.Additional bars at corners, intersections, openings, etc. X 7. Free of LOOSE mill scale, rust X 8. Free of oil, mud, hardened concrete, tags, form coating X 9. Dowels where shown and securely tied in-place X 10. Beams/slabs spliced near supports for bottom steel, near midspan for top steel X 11. No kinked or bent tension steel X 12. All reinforcing steel securely tied and supported to prevent displacement during pour X 13. Approved chairs and spacers installed BEFORE pour X 14. No welding on reinforcing steel without approval of Structural Engineer X 15. Adequate spaces for proper placement of concrete 16. No bending or displacement due to embedded items or boxes unless approved by X Structural Engineer X 17. No cutting to avoid obstructions except as approved by Structural Engineer X 18. Stirrup corners tight to vertical and not sloped to make tight Notes: 1)All NG items are to be reported to Contractor immediately via inspection report 2) NA= Not Applicable Remarks: *Steel mesh (1 grid overlap)and vapor barrier in place. **Slab dowels around the perimeter at 4"o.c. Tod Kobik. QC/QA Laboratories, Inc. PROMPT SERVICE. FAIR PRICES. ACCURATE RESULTS. Vice-President g/Forms/Concrete/Rebar Inspection/Rebar Insp-8.2.07 QCQA INSPECTOR'S DAILY REPORT �"," Date: 9/3/2019 DRILLING & TESTING SERVICES S M T W T F S Project: Stewart's Shop-Queensbury, NY Day X Client: Stewart's Shops Weather Bri ht Clear Overcast Rain Snow X Bldg./Area Roof Truss Bracing and Shear Wall Anchors Temp. T_0 32 32-50 50-70 . Contractor: Hilltop Construction Wind Still Moderate High Report No. X QCQA Proj.# 19-078 Humidity p Moderate Humid 1-090319 I X OBSERVATIONS The undersigned representative of QCQA Labs was on site at the above project as requested for inspection of permanent bracing of wood roof trusses and to verify installation of seismic anchor brackets at shear walls.Wood roof truss bracing requirements were depicted on the trenco truss drawings dated August 6, 2019.The undersigned identified a few locations where permanent braces had not been installed.This was discussed with the contractor and all bracing was installed while the undersigned was onsite. The undersigned also observed seismic anchors at shear walls. Fiber glass insulation had been installed on the north wall, north half of east wall and south half of west wall. Seismic anchors that were visible at all other wall sections appeared to be installed at locations shown on drawing A-4B dated 7/9/19. See Also (Test Report Nos.): Inspector Tod Kobik, P.E. 877 Route 4S - Schuylerville, NY 12871 - ph (518)372-4067 -fax(518)507-6113 CONSTRUCTION TECHNOLOGY INSPECTION&TESTING DIVISION, P.D.&T.S., INC. 4 William Street,Ballston Lake,New York 12019 Phone: (518)399-1848 Fax:(518)399-1913 CLIENT: STEWART'S ICE CREAM COMPANY,INC. REPORT DATE: 08/15/19 POST OFFICE BOX 435 SAMPLE NUMBER: 18909 SARATOGA SPRINGS,NEW YORK 12866 OUR FILE NUMBER: 702.025 LAB TECHNICIAN: BOB BEHAN ATTN: MR.CHRISTOPHER POTTER PROJECT: STEWART'S SHOP:347 AVIATION ROAD,QUEENSEURY,NY. REPORT OF MOISTURE/DENSITY RELATION OF SOILS ::: PROCTOR MATERIAL SOURCE: ONSITE MATERIAL MATERIAL DESCRIPTION: SAND,medium/tine;some fine Gravel;trace Silt`Clay PROCTOR METHOD: ASTM D-1557:MODIFIED EFFORT GRADATION METHOD: ASTM D-1140 I D-422:WASHED +3/4"CORRECTION: 124.4 PCF ZERO AIR VOIDS CURVE: 2.68 SPECIFIC GRAVITY MAXIMUM DENSITY 117.7 PCF OPTIMUM MOISTURE 13.2 % 123 1 j GRADATION 122 i I SIEVE PERCENT SPECIFICATION 1 i iiii, SIZE PASSING ALLOWANCE 121 I t } 4" 3 120 Si 2 1/2" i- 2" 100.0 z 119 I 1 W 1 1/2" G 1" 83.3 cZ 118 — — �_..-.._...._ _._.. — — -—... CI i 3'4" 82.0 I-0 ! I 1/2" 80.0 0 117 u. 3/8" 78.8 t) , 1/4" 77.8 r 116 #4 76.9 V _ , ! lib" a 115 —. __ � . __ #8 • 73.6 G __— — #10 z 114 i I 1 416 63.4 a ! ! #20 113 - I #30 32.2 --—'---#40 19.6 112 ' #50 10.3 460 111 j 1gil#80 4 4 i#100 4.3 110 i i — J , IJ #140 9 10 11 12 13 14 15 16 17 #200 2.9 MOISTURE CONTENT::: PERCENT DRY WEIGHT REPORT DISTRIBUTION: GENERAL NOTES: Respectfully, 1: CONSTRUCTION TECHNOLOGY 2: 3: �.�►gees er 4: TOM JOSLIN,S.E.T.,(NICET) 5: MANAGER TECHNICAL SERVICES CONSTRUCTION TECHNOLOGY INSPECTION&TESTING DIVISION,P.D.&T.S., INC. 4 William Street,Ballston Lake,New York 12019 Phone: (518)399-1848 Fax: (518) 399-1913 CLIENT: STEWART'S ICE CREAM COMPANY,INC. REPORT NUMBER: 1 :PAGE#: 1 POST OFFICE BOX 435 INSPECTION DATE: 08/15/19 SARATOGA SPRINGS, NEW YORK 12866 OUR FILE NUMBER: 702.025 FIELD INSPECTOR: BOB BEHAN ATT'N: MR.CHRISTOPHER POTTER PROJECT:STEWART'S SHOP:347 AVIATION ROAD,QUEENSBURY, NY. SOIL COMPACTION VERIFICATION REPORT ::: INPLACE SOIL DENSITY MATERIALS LABORATORY DATA CODE MOISTURE MAX DENSITY PCF MATERIAL DESCRIPTION MATERIAL SOURCE 18909 13.2 124.4 SAND, medium/fine;some fine Gravel;trace Silt/Clay ONSITE MATERIAL FIELD COMPACTION TEST RESULTS LOCATION OF TESTING: FOUNDATION BACKFILL ELEVATION REFERENCE: F.G.=FINISH GRADE=TOP OF FOUNDATION WALL COMPACTION TEST METHOD ASTM D-6938 CO-ORDINATE REFERENCE: PER LOCATION COMPACTION REQUIREMENTS 95.0% TEST SOIL SOIL DEPTH OR MOISTURE INPLACE DRY PERCENT NO. BEARING CODE ELEVATION LOCATION OF TEST CONTENT DENSITY(PCF) COMPACT 1 18909 F.G. -3.00' INTERIOR BACKFILL:NORTH WALL,CENTER 5.3% 119.6 96.1 2 18909 F.G. -3.00' INTERIOR BACKFILL:EAST WALL,CENTER 5.2% 118.9 95.6% 3 18909 F.G. -2.50' INTERIOR BACKFILL:WEST WALL,CENTER 6.3% 122.6 98.6% 4 18909 F.G. -2.50' INTERIOR BACKFILL:SOUTH WALL,CENTER 5.6% 119.2 95.8% 5 18909 F.G. -2.00' INTERIOR BACKFILL:SOUTH WALL,CENTER 5.4% 118.7 95.4 6 18909 F.G. -2.00' INTERIOR BACKFILL:NORTH WALL,CENTER 5.8% 120.6 96.9% 7 18909 F.G. -2.50' INTERIOR BACKFILL:EAST WALL,CENTER 6.1 % 120.9 97.2 REPORT DISTRIBUTION: GENERAL NOTES: RESPECTFULLY SUBMITTED, 1:FILE 1. D-1556=SAND CONE METHOD OF TEST CONSTRUCTION TECHNOLOGY 2: 2. D-6938=NUCLEAR GAUGE METHOD OF TEST 3: 3. FF =FINISH FLOOR ����� 4: 4. FG =FINISH GRADE 5: 5. TOM JOSLIN,S.E.T.(NICET) 6: 6. MANAGER TECHNICAL SERVICES