inspectionsINSPECTION WORKSHEET (BINS-001011-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-0539-2018 Case Module:Permit
Inspection Date:Wed Feb 20, 2019 Inspection Status:Partial Pass
Inspector:John O'Brien Inspection Type:Building Framing
Job Address:Parcel Number:59 WEST MOUNTAIN RD
Queensbury, NY 12804
307.-1-29
Contact Type Company Name Name
Architect AJA Architecture & Planning
Applicant Montgomery, Spencer
Granted Permission East Slope Holding, LP
Primary Owner East Slope Holding, LP
Checklist Item Passed Comments
Building Inspector Notes NO 1/14/19 Framing Partial Approval
- Balance of existing kitchen framing.
- Walls and Roof Joists
Remaining Items:
- Provide Engineer's Inspection Reports for All Framing.
Ok to sprayfoam ceiling & exterior walls.
2/20/19 Framing Partial Approval
Remaining Items:
- Provide Engineer's Inspection Reports for All Framing.
Framing YES Partial only- for walls at prep and dishwasher area 12/31/18
1/14/19 Framing Partial Approval
- Balance of existing kitchen framing.
- Walls and Roof Joists
Remaining Items:
- Provide Engineer's Inspection Reports for All Framing.
Ok to sprayfoam ceiling & exterior walls.
Ice and water shield 24 inches from wall NO
Feb 20, 2019 Page (1)
INSPECTION WORKSHEET (BINS-001011-2019)
Checklist Item Passed Comments
Design Professional Sign-off, if required NO 1/14/19 Framing Partial Approval
- Balance of existing kitchen framing.
- Walls and Roof Joists
Remaining Items:
- Provide Engineer's Inspection Reports for All Framing.
Ok to sprayfoam ceiling & exterior walls.
Remaining Items:
- Provide Engineer's Inspection Reports for All Framing.
Feb 20, 2019 Page (2)
O'Brien, John (Inspector)
INSPECTION WORKSHEET (BINS-000395-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0539-2018Permit
Case Number:Case Module:
Thu Jan 17, 2019Partial Pass
Inspection Date:Inspection Status:
John O'BrienBuilding Insulation
Inspector:Inspection Type:
59 WEST MOUNTAIN RD307.-1-29
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
ArchitectAJA Architecture & Planning
ApplicantMontgomery, Spencer
Primary OwnerEast Slope Holding, LP
Granted PermissionEast Slope Holding, LP
Checklist ItemPassedComments
Building Inspector NotesNO1/17/19 Insulation Partial Approval - Exterior Walls and
Ceilings of New Addition & Existing Ceiling and East Wall of
Kitchen.
- Existing Ceiling (3" of closed cell foam at R22.2)
- New Ceiling (5" of closed cell foam at R37)
- Exterior Walls (3" of closed cell foam at R22.2)
Andrew please provide a COMcheck for renovation area and
new kitchen addition based on what has been installed it
does not reflect the approved project plans.
Window SealingNO
U Factors = .3 cfm for windows, .5 cfm for doorsNO
Tyvek or Similar Exterior SealantNO
Jan 17, 2019Page (1)
INSPECTION WORKSHEET (BINS-000395-2019)
Checklist ItemPassedComments
Proper Vent, Attic VentNO
Insulation Residential Check Commercial CheckNO1/17/19 Insulation Partial Approval - Exterior Walls and
Ceilings of New Addition & Existing Ceiling and East Wall of
Kitchen.
- Existing Ceiling (3" of closed cell foam at R22.2)
- New Ceiling (5" of closed cell foam at R37)
- Exterior Walls (3" of closed cell foam at R22.2)
Andrew please provide a COMcheck for renovation area and
new kitchen addition based on what has been installed it
does not reflect the approved project plans.
Blower Door TestNO
Combustion Air Supply for FurnaceNO
Fresh air supply 3' from gradeNO
Duct Insulation - if required in unheated spacesNO
Door / Window Sealed (No Insulation)NO
Air Barrier behind Knee WallsNO
Tub Shower R-20 with Vapor BarrierNO
All Ductwork Sealed Return and SupplyNO
Duct Blaster Test for duct work, R-8NO
All Return Air Hard Duct WorkNO
House Wrap Taped at all SeamsNO
O'Brien, John (Inspector)
Jan 17, 2019Page (2)
INSPECTION WORKSHEET (RPLUM-000423-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0539-2018Permit
Case Number:Case Module:
Thu Jan 17, 2019Partial Pass
Inspection Date:Inspection Status:
John O'BrienRough Plumbing
Inspector:Inspection Type:
59 WEST MOUNTAIN RD307.-1-29
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
Primary OwnerEast Slope Holding, LP
ArchitectAJA Architecture & Planning
Granted PermissionEast Slope Holding, LP
ApplicantMontgomery, Spencer
Checklist ItemPassedComments
Building Inspector NotesNO10/25/18 Plumbing Under Slab Approved
Pressure Tests Approved
-Water 90 psi
-Sanitary 7 psi
1/17/19 Plumbing Partial Approval
- Sanitary pressure test approved 7 psi
- Water pressure test approved 90 psi
Remaining Items:
- Complete all final connections
- Piping Insulation
- Pressure test new gas lines
Plumbing Under SlabYES10/25/18 Plumbing Under Slab Approved
Pressure Tests Approved
-Water 90 psi
-Sanitary 7 psi
Jan 17, 2019Page (1)
INSPECTION WORKSHEET (RPLUM-000423-2019)
Checklist ItemPassedComments
Rough Plumbing / Nail PlatesYES1/17/19 Plumbing Partial Approval
- Sanitary pressure test approved 7 psi
- Water pressure test approved 90 psi
Remaining Items:
- Complete all final connections
- Piping Insulation
- Pressure test new gas lines
Pressure TestYESPlumbing under slab only!
Air HeadYESAir
5 psi or 10 ft. above highest conn. for 15 minutesYESPlumbing under slab only!
Pressure TestYESPlumbing under slab only!
Air HeadYESAir
50 P.S.I for 15 minutesYESPlumbing under slab only!
Air Test Gas Piping 10 psi for 10 MinutesNO
All Return Air Hard Duct WorkNO
Duct Insulation - if required in unheated spacesNO
Duct Testing Outside Conditioned SpaceNO
Duct work sealed properlyNO
O'Brien, John (Inspector)
Jan 17, 2019Page (2)
INSPECTION WORKSHEET (BINS-007554-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-0539-2018Case Module:Permit
Inspection Date:10/25/2018Inspection Status:Partial Pass
Inspector:John O'BrienInspection Type:Building Foundation
Job Address:59 WEST MOUNTAIN RDParcel Number:307.-1-29
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantMontgomery, Spencer
Primary OwnerEast Slope Holding, LP\[East Slope Holding, LP\]
ArchitectAJA Architecture & Planning\[AJA Architecture & Planning\] ,
Granted PermissionEast Slope Holding, LP\[East Slope Holding, LP\]
Checklist ItemPassedComments
Building Inspector NotesNO10/25/18 Interior Pier Footings Approved
FootingsYES10/25/18 Interior Pier Footings Approved
PiersNO
Monolithic SlabNO
Reinforcement in PlaceYES10/25/18 Interior Pier Footings Approved
Reinforcement in PlaceNO
Foundation / WallpourNO
Footing Dowels or Keyway in placeYES10/25/18 Interior Pier Footings Approved
Foundation DampproofingNO
Foundation WaterproofingNO
Footing Drain Daylight or SumpNO
Footing Drain Stone - 12 inch widthNO
Footing Drain Stone - 6 inches above footingNO
Footing Drain stone - 6 mil polyNO
Backfill ApprovalNO
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Oct 25, 2018Page (1)
INSPECTION WORKSHEET (BINS-007554-2018)
Checklist ItemPassedComments
Poly Under SlabNO
O'Brien, John (Inspector)
Oct 25, 2018Page (2)
INSPECTION WORKSHEET (RPLUM-007553-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-0539-2018Case Module:Permit
Inspection Date:10/25/2018Inspection Status:Partial Pass
Inspector:John O'BrienInspection Type:Rough Plumbing
Job Address:59 WEST MOUNTAIN RDParcel Number:307.-1-29
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantMontgomery, Spencer
Primary OwnerEast Slope Holding, LP\[East Slope Holding, LP\]
ArchitectAJA Architecture & Planning\[AJA Architecture & Planning\] ,
Granted PermissionEast Slope Holding, LP\[East Slope Holding, LP\]
Checklist ItemPassedComments
Building Inspector NotesNO10/25/18 Plumbing Under Slab Approved
Pressure Tests Approved
-Water 90 psi
-Sanitary 7 psi
Plumbing Under SlabYES10/25/18 Plumbing Under Slab Approved
Pressure Tests Approved
-Water 90 psi
-Sanitary 7 psi
Rough Plumbing / Nail PlatesNO
Plumbing Vent Vents in PlaceNO
3" Vent Through RoofNO
1 ½ inch minimum Drain SizeYES
Washing Machine Drain 2 inch minimumNO
Washing Machine Trap: 18"-24" dischargeNO
Cleanout every 100 feet change of directionYES
Pressure TestYESPlumbing under slab only!
Pressure TestYESPlumbing under slab only!
Drain VentNO
5 psi or 10 ft. above highest conn. for 15 minutesYESPlumbing under slab only!
Water Supply PipingNO
Air HeadNO
Air HeadNO
50 P.S.I for 15 minutesYESPlumbing under slab only!
Air Test Gas Piping 10 psi for 10 MinutesNO
All Return Air Hard Duct WorkNO
Duct Insulation - if required in unheated spacesNO
Duct Testing Outside Conditioned SpaceNO
O'Brien, John (Inspector)
Duct work sealed properlyNO
Oct 25, 2018Page (2)
INSPECTION WORKSHEET (BINS-000332-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0539-2018Permit
Case Number:Case Module:
Mon Jan 14, 2019Partial Pass
Inspection Date:Inspection Status:
John O'BrienBuilding Framing
Inspector:Inspection Type:
59 WEST MOUNTAIN RD307.-1-29
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantMontgomery, Spencer
Granted PermissionEast Slope Holding, LP
Primary OwnerEast Slope Holding, LP
ArchitectAJA Architecture & Planning
Checklist ItemPassedComments
Building Inspector NotesNO1/14/19 Framing Partial Approval
- Balance of existing kitchen framing.
- Walls and Roof Joists
Remaining Items:
- Provide Engineer's Inspection Reports for All Framing.
Ok to sprayfoam ceiling & exterior walls.
FramingYESPartial only- for walls at prep and dishwasher area 12/31/18
1/14/19 Framing Partial Approval
- Balance of existing kitchen framing.
- Walls and Roof Joists
Remaining Items:
- Provide Engineer's Inspection Reports for All Framing.
Ok to sprayfoam ceiling & exterior walls.
Attic Access 22 x 30 minimumNO
Jack Studs HeadersNO
Jan 14, 2019Page (1)
INSPECTION WORKSHEET (BINS-000332-2019)
Checklist ItemPassedComments
Continuous Header for Garage Doors withNO
Straping
Truss Specification ProvidedNO
Air Seal all Plates and SillsNO
Air Seal All Registers at FloorNO
Air Sealing all Joints Before InsulationNO
Joist hangersNO
Exterior sheeting nailed properlyNO
12 O.C.NO
Headroom 6 ft. 8 in.NO
Notches Holes Bearing WallsNO
Metal Strapping for Notches Top PlateNO
Draft stopping 1,000 sq. ft. floor trussesNO
Ice and water shield 24 inches from wallNO
Soffits-Insulation BaffelNO
Windows Habitable Space BedroomsNO
Jan 14, 2019Page (2)
INSPECTION WORKSHEET (BINS-000332-2019)
Checklist ItemPassedComments
24 in. (H)NO
20 in. (W)NO
5.7 sf above below gradeNO
5.0 sf gradeNO
Design Professional Sign-off, if requiredNO1/14/19 Framing Partial Approval
- Balance of existing kitchen framing.
- Walls and Roof Joists
Remaining Items:
- Provide Engineer's Inspection Reports for All Framing.
Ok to sprayfoam ceiling & exterior walls.
O'Brien, John (Inspector)
Jan 14, 2019Page (3)
INSPECTION WORKSHEET (BINS-008641-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0539-2018Permit
Case Number:Case Module:
Mon Dec 10, 2018Voided
Inspection Date:Inspection Status:
John O'BrienBuilding Foundation
Inspector:Inspection Type:
59 WEST MOUNTAIN RD307.-1-29
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantMontgomery, Spencer
Granted PermissionEast Slope Holding, LP
ArchitectAJA Architecture & Planning
Primary OwnerEast Slope Holding, LP
Checklist ItemPassedComments
Building Inspector NotesNO10/25/18 Interior Pier Footings Approved
11/29/18 Footings Approved (addition)
12/3/18 Foundation Walls Approved (addition)
12/4/18 Backfill & Foundation Wall Partial Approval (Addition)
- 2" Foundation Insulation is approved up to the floor shelf.
The 2" insulation needs to continue up shelf to top of
foundation wall for proper frost protection.
FootingsYES10/25/18 Interior Pier Footings Approved
11/29/18 Footings Approved (addition)
PiersYESInterior piers as per page S203 10/30/18
Verified piers for columns with # 5 grids 12/7/18
Monolithic SlabNO
Dec 10, 2018Page (1)
INSPECTION WORKSHEET (BINS-008641-2018)
Checklist ItemPassedComments
Reinforcement in PlaceYES10/25/18 Interior Pier Footings Approved
11/29/18 Footings Approved (addition)
Foundation / WallpourYES12/3/18 Foundation Walls Approved (addition)
Reinforcement in PlaceYES12/3/18 Foundation Walls Approved (addition)
Footing Dowels or Keyway in placeYES10/25/18 Interior Pier Footings Approved
Foundation DampproofingNO
Foundation WaterproofingNO
Footing Drain Daylight or SumpNO
Footing Drain Stone - 12 inch widthNO
Footing Drain Stone - 6 inches above footingNO
Footing Drain stone - 6 mil polyNO
Backfill ApprovalYES12/4/18 Backfill & Foundation Wall Partial Approval (Addition)
- 2" Foundation Insulation is approved up to the floor shelf.
The 2" insulation needs to continue up shelf to top of
foundation wall for proper frost protection.
Plumbing Under SlabNO
PVC / Cast / CopperNO
Dec 10, 2018Page (2)
INSPECTION WORKSHEET (BINS-008641-2018)
Checklist ItemPassedComments
Foundation Insulation Interior / ExteriorNO12/4/18 Backfill & Foundation Wall Partial Approval (Addition)
- 2" Foundation Insulation is approved up to the floor shelf.
The 2" insulation needs to continue up shelf to top of
foundation wall for proper frost protection.
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabNO
O'Brien, John (Inspector)
Dec 10, 2018Page (3)
INSPECTION WORKSHEET (BINS-008463-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0539-2018Permit
Case Number:Case Module:
Tue Dec 4, 2018Partial Pass
Inspection Date:Inspection Status:
John O'BrienBuilding Foundation
Inspector:Inspection Type:
59 WEST MOUNTAIN RD307.-1-29
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantMontgomery, Spencer
Primary OwnerEast Slope Holding, LP
Granted PermissionEast Slope Holding, LP
ArchitectAJA Architecture & Planning
Checklist ItemPassedComments
Building Inspector NotesNO10/25/18 Interior Pier Footings Approved
11/29/18 Footings Approved (addition)
12/3/18 Foundation Walls Approved (addition)
12/4/18 Backfill & Foundation Wall Partial Approval (Addition)
- 2" Foundation Insulation is approved up to the floor shelf.
The 2" insulation needs to continue up shelf to top of
foundation wall for proper frost protection.
FootingsYES10/25/18 Interior Pier Footings Approved
11/29/18 Footings Approved (addition)
PiersYESInterior piers as per page S203 10/30/18
Monolithic SlabNO
Reinforcement in PlaceYES10/25/18 Interior Pier Footings Approved
11/29/18 Footings Approved (addition)
Dec 04, 2018Page (1)
INSPECTION WORKSHEET (BINS-008463-2018)
Checklist ItemPassedComments
Foundation / WallpourYES12/3/18 Foundation Walls Approved (addition)
Reinforcement in PlaceYES12/3/18 Foundation Walls Approved (addition)
Footing Dowels or Keyway in placeYES10/25/18 Interior Pier Footings Approved
Foundation DampproofingNO
Foundation WaterproofingNO
Footing Drain Daylight or SumpNO
Footing Drain Stone - 12 inch widthNO
Footing Drain Stone - 6 inches above footingNO
Footing Drain stone - 6 mil polyNO
Backfill ApprovalYES12/4/18 Backfill & Foundation Wall Partial Approval (Addition)
- 2" Foundation Insulation is approved up to the floor shelf.
The 2" insulation needs to continue up shelf to top of
foundation wall for proper frost protection.
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO12/4/18 Backfill & Foundation Wall Partial Approval (Addition)
- 2" Foundation Insulation is approved up to the floor shelf.
The 2" insulation needs to continue up shelf to top of
foundation wall for proper frost protection.
Rough Grade 6 inch drop within 10 ft.NO
Dec 04, 2018Page (2)
INSPECTION WORKSHEET (BINS-008463-2018)
Checklist ItemPassedComments
Poly Under SlabNO
O'Brien, John (Inspector)
Dec 04, 2018Page (3)
INSPECTION WORKSHEET (BINS-008429-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-0539-2018Permit
Case Number:Case Module:
Mon Dec 3, 2018Partial Pass
Inspection Date:Inspection Status:
John O'BrienBuilding Foundation
Inspector:Inspection Type:
59 WEST MOUNTAIN RD307.-1-29
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
ArchitectAJA Architecture & Planning
Primary OwnerEast Slope Holding, LP
ApplicantMontgomery, Spencer
Granted PermissionEast Slope Holding, LP
Checklist ItemPassedComments
Building Inspector NotesNO10/25/18 Interior Pier Footings Approved
11/29/18 Footings Approved (addition)
12/3/18 Foundation Walls Approved (addition)
FootingsYES10/25/18 Interior Pier Footings Approved
11/29/18 Footings Approved (addition)
PiersYESInterior piers as per page S203 10/30/18
Monolithic SlabNO
Reinforcement in PlaceYES10/25/18 Interior Pier Footings Approved
11/29/18 Footings Approved (addition)
Foundation / WallpourYES12/3/18 Foundation Walls Approved (addition)
Dec 03, 2018Page (1)
INSPECTION WORKSHEET (BINS-008429-2018)
Checklist ItemPassedComments
Reinforcement in PlaceYES12/3/18 Foundation Walls Approved (addition)
Footing Dowels or Keyway in placeYES10/25/18 Interior Pier Footings Approved
Foundation DampproofingNO
Foundation WaterproofingNO
Footing Drain Daylight or SumpNO
Footing Drain Stone - 12 inch widthNO
Footing Drain Stone - 6 inches above footingNO
Footing Drain stone - 6 mil polyNO
Backfill ApprovalNO
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabNO
O'Brien, John (Inspector)
Dec 03, 2018Page (2)