inspectionsINSPECTION WORKSHEET (BINS-001011-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0539-2018 Case Module:Permit Inspection Date:Wed Feb 20, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Building Framing Job Address:Parcel Number:59 WEST MOUNTAIN RD Queensbury, NY 12804 307.-1-29 Contact Type Company Name Name Architect AJA Architecture & Planning Applicant Montgomery, Spencer Granted Permission East Slope Holding, LP Primary Owner East Slope Holding, LP Checklist Item Passed Comments Building Inspector Notes NO 1/14/19 Framing Partial Approval - Balance of existing kitchen framing. - Walls and Roof Joists Remaining Items: - Provide Engineer's Inspection Reports for All Framing. Ok to sprayfoam ceiling & exterior walls. 2/20/19 Framing Partial Approval Remaining Items: - Provide Engineer's Inspection Reports for All Framing. Framing YES Partial only- for walls at prep and dishwasher area 12/31/18 1/14/19 Framing Partial Approval - Balance of existing kitchen framing. - Walls and Roof Joists Remaining Items: - Provide Engineer's Inspection Reports for All Framing. Ok to sprayfoam ceiling & exterior walls. Ice and water shield 24 inches from wall NO Feb 20, 2019 Page (1) INSPECTION WORKSHEET (BINS-001011-2019) Checklist Item Passed Comments Design Professional Sign-off, if required NO 1/14/19 Framing Partial Approval - Balance of existing kitchen framing. - Walls and Roof Joists Remaining Items: - Provide Engineer's Inspection Reports for All Framing. Ok to sprayfoam ceiling & exterior walls. Remaining Items: - Provide Engineer's Inspection Reports for All Framing. Feb 20, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (BINS-000395-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0539-2018Permit Case Number:Case Module: Thu Jan 17, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Insulation Inspector:Inspection Type: 59 WEST MOUNTAIN RD307.-1-29 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName ArchitectAJA Architecture & Planning ApplicantMontgomery, Spencer Primary OwnerEast Slope Holding, LP Granted PermissionEast Slope Holding, LP Checklist ItemPassedComments Building Inspector NotesNO1/17/19 Insulation Partial Approval - Exterior Walls and Ceilings of New Addition & Existing Ceiling and East Wall of Kitchen. - Existing Ceiling (3" of closed cell foam at R22.2) - New Ceiling (5" of closed cell foam at R37) - Exterior Walls (3" of closed cell foam at R22.2) Andrew please provide a COMcheck for renovation area and new kitchen addition based on what has been installed it does not reflect the approved project plans. Window SealingNO U Factors = .3 cfm for windows, .5 cfm for doorsNO Tyvek or Similar Exterior SealantNO Jan 17, 2019Page (1) INSPECTION WORKSHEET (BINS-000395-2019) Checklist ItemPassedComments Proper Vent, Attic VentNO Insulation Residential Check Commercial CheckNO1/17/19 Insulation Partial Approval - Exterior Walls and Ceilings of New Addition & Existing Ceiling and East Wall of Kitchen. - Existing Ceiling (3" of closed cell foam at R22.2) - New Ceiling (5" of closed cell foam at R37) - Exterior Walls (3" of closed cell foam at R22.2) Andrew please provide a COMcheck for renovation area and new kitchen addition based on what has been installed it does not reflect the approved project plans. Blower Door TestNO Combustion Air Supply for FurnaceNO Fresh air supply 3' from gradeNO Duct Insulation - if required in unheated spacesNO Door / Window Sealed (No Insulation)NO Air Barrier behind Knee WallsNO Tub Shower R-20 with Vapor BarrierNO All Ductwork Sealed Return and SupplyNO Duct Blaster Test for duct work, R-8NO All Return Air Hard Duct WorkNO House Wrap Taped at all SeamsNO O'Brien, John (Inspector) Jan 17, 2019Page (2) INSPECTION WORKSHEET (RPLUM-000423-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0539-2018Permit Case Number:Case Module: Thu Jan 17, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienRough Plumbing Inspector:Inspection Type: 59 WEST MOUNTAIN RD307.-1-29 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName Primary OwnerEast Slope Holding, LP ArchitectAJA Architecture & Planning Granted PermissionEast Slope Holding, LP ApplicantMontgomery, Spencer Checklist ItemPassedComments Building Inspector NotesNO10/25/18 Plumbing Under Slab Approved Pressure Tests Approved -Water 90 psi -Sanitary 7 psi 1/17/19 Plumbing Partial Approval - Sanitary pressure test approved 7 psi - Water pressure test approved 90 psi Remaining Items: - Complete all final connections - Piping Insulation - Pressure test new gas lines Plumbing Under SlabYES10/25/18 Plumbing Under Slab Approved Pressure Tests Approved -Water 90 psi -Sanitary 7 psi Jan 17, 2019Page (1) INSPECTION WORKSHEET (RPLUM-000423-2019) Checklist ItemPassedComments Rough Plumbing / Nail PlatesYES1/17/19 Plumbing Partial Approval - Sanitary pressure test approved 7 psi - Water pressure test approved 90 psi Remaining Items: - Complete all final connections - Piping Insulation - Pressure test new gas lines Pressure TestYESPlumbing under slab only! Air HeadYESAir 5 psi or 10 ft. above highest conn. for 15 minutesYESPlumbing under slab only! Pressure TestYESPlumbing under slab only! Air HeadYESAir 50 P.S.I for 15 minutesYESPlumbing under slab only! Air Test Gas Piping 10 psi for 10 MinutesNO All Return Air Hard Duct WorkNO Duct Insulation - if required in unheated spacesNO Duct Testing Outside Conditioned SpaceNO Duct work sealed properlyNO O'Brien, John (Inspector) Jan 17, 2019Page (2) INSPECTION WORKSHEET (BINS-007554-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0539-2018Case Module:Permit Inspection Date:10/25/2018Inspection Status:Partial Pass Inspector:John O'BrienInspection Type:Building Foundation Job Address:59 WEST MOUNTAIN RDParcel Number:307.-1-29 Queensbury, NY 12804 Contact TypeCompany NameName ApplicantMontgomery, Spencer Primary OwnerEast Slope Holding, LP\[East Slope Holding, LP\] ArchitectAJA Architecture & Planning\[AJA Architecture & Planning\] , Granted PermissionEast Slope Holding, LP\[East Slope Holding, LP\] Checklist ItemPassedComments Building Inspector NotesNO10/25/18 Interior Pier Footings Approved FootingsYES10/25/18 Interior Pier Footings Approved PiersNO Monolithic SlabNO Reinforcement in PlaceYES10/25/18 Interior Pier Footings Approved Reinforcement in PlaceNO Foundation / WallpourNO Footing Dowels or Keyway in placeYES10/25/18 Interior Pier Footings Approved Foundation DampproofingNO Foundation WaterproofingNO Footing Drain Daylight or SumpNO Footing Drain Stone - 12 inch widthNO Footing Drain Stone - 6 inches above footingNO Footing Drain stone - 6 mil polyNO Backfill ApprovalNO Plumbing Under SlabNO PVC / Cast / CopperNO Foundation Insulation Interior / ExteriorNO Rough Grade 6 inch drop within 10 ft.NO Oct 25, 2018Page (1) INSPECTION WORKSHEET (BINS-007554-2018) Checklist ItemPassedComments Poly Under SlabNO O'Brien, John (Inspector) Oct 25, 2018Page (2) INSPECTION WORKSHEET (RPLUM-007553-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0539-2018Case Module:Permit Inspection Date:10/25/2018Inspection Status:Partial Pass Inspector:John O'BrienInspection Type:Rough Plumbing Job Address:59 WEST MOUNTAIN RDParcel Number:307.-1-29 Queensbury, NY 12804 Contact TypeCompany NameName ApplicantMontgomery, Spencer Primary OwnerEast Slope Holding, LP\[East Slope Holding, LP\] ArchitectAJA Architecture & Planning\[AJA Architecture & Planning\] , Granted PermissionEast Slope Holding, LP\[East Slope Holding, LP\] Checklist ItemPassedComments Building Inspector NotesNO10/25/18 Plumbing Under Slab Approved Pressure Tests Approved -Water 90 psi -Sanitary 7 psi Plumbing Under SlabYES10/25/18 Plumbing Under Slab Approved Pressure Tests Approved -Water 90 psi -Sanitary 7 psi Rough Plumbing / Nail PlatesNO Plumbing Vent Vents in PlaceNO 3" Vent Through RoofNO 1 ½ inch minimum Drain SizeYES Washing Machine Drain 2 inch minimumNO Washing Machine Trap: 18"-24" dischargeNO Cleanout every 100 feet change of directionYES Pressure TestYESPlumbing under slab only! Pressure TestYESPlumbing under slab only! Drain VentNO 5 psi or 10 ft. above highest conn. for 15 minutesYESPlumbing under slab only! Water Supply PipingNO Air HeadNO Air HeadNO 50 P.S.I for 15 minutesYESPlumbing under slab only! Air Test Gas Piping 10 psi for 10 MinutesNO All Return Air Hard Duct WorkNO Duct Insulation - if required in unheated spacesNO Duct Testing Outside Conditioned SpaceNO O'Brien, John (Inspector) Duct work sealed properlyNO Oct 25, 2018Page (2) INSPECTION WORKSHEET (BINS-000332-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0539-2018Permit Case Number:Case Module: Mon Jan 14, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Framing Inspector:Inspection Type: 59 WEST MOUNTAIN RD307.-1-29 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName ApplicantMontgomery, Spencer Granted PermissionEast Slope Holding, LP Primary OwnerEast Slope Holding, LP ArchitectAJA Architecture & Planning Checklist ItemPassedComments Building Inspector NotesNO1/14/19 Framing Partial Approval - Balance of existing kitchen framing. - Walls and Roof Joists Remaining Items: - Provide Engineer's Inspection Reports for All Framing. Ok to sprayfoam ceiling & exterior walls. FramingYESPartial only- for walls at prep and dishwasher area 12/31/18 1/14/19 Framing Partial Approval - Balance of existing kitchen framing. - Walls and Roof Joists Remaining Items: - Provide Engineer's Inspection Reports for All Framing. Ok to sprayfoam ceiling & exterior walls. Attic Access 22 x 30 minimumNO Jack Studs HeadersNO Jan 14, 2019Page (1) INSPECTION WORKSHEET (BINS-000332-2019) Checklist ItemPassedComments Continuous Header for Garage Doors withNO Straping Truss Specification ProvidedNO Air Seal all Plates and SillsNO Air Seal All Registers at FloorNO Air Sealing all Joints Before InsulationNO Joist hangersNO Exterior sheeting nailed properlyNO 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing WallsNO Metal Strapping for Notches Top PlateNO Draft stopping 1,000 sq. ft. floor trussesNO Ice and water shield 24 inches from wallNO Soffits-Insulation BaffelNO Windows Habitable Space BedroomsNO Jan 14, 2019Page (2) INSPECTION WORKSHEET (BINS-000332-2019) Checklist ItemPassedComments 24 in. (H)NO 20 in. (W)NO 5.7 sf above below gradeNO 5.0 sf gradeNO Design Professional Sign-off, if requiredNO1/14/19 Framing Partial Approval - Balance of existing kitchen framing. - Walls and Roof Joists Remaining Items: - Provide Engineer's Inspection Reports for All Framing. Ok to sprayfoam ceiling & exterior walls. O'Brien, John (Inspector) Jan 14, 2019Page (3) INSPECTION WORKSHEET (BINS-008641-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0539-2018Permit Case Number:Case Module: Mon Dec 10, 2018Voided Inspection Date:Inspection Status: John O'BrienBuilding Foundation Inspector:Inspection Type: 59 WEST MOUNTAIN RD307.-1-29 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName ApplicantMontgomery, Spencer Granted PermissionEast Slope Holding, LP ArchitectAJA Architecture & Planning Primary OwnerEast Slope Holding, LP Checklist ItemPassedComments Building Inspector NotesNO10/25/18 Interior Pier Footings Approved 11/29/18 Footings Approved (addition) 12/3/18 Foundation Walls Approved (addition) 12/4/18 Backfill & Foundation Wall Partial Approval (Addition) - 2" Foundation Insulation is approved up to the floor shelf. The 2" insulation needs to continue up shelf to top of foundation wall for proper frost protection. FootingsYES10/25/18 Interior Pier Footings Approved 11/29/18 Footings Approved (addition) PiersYESInterior piers as per page S203 10/30/18 Verified piers for columns with # 5 grids 12/7/18 Monolithic SlabNO Dec 10, 2018Page (1) INSPECTION WORKSHEET (BINS-008641-2018) Checklist ItemPassedComments Reinforcement in PlaceYES10/25/18 Interior Pier Footings Approved 11/29/18 Footings Approved (addition) Foundation / WallpourYES12/3/18 Foundation Walls Approved (addition) Reinforcement in PlaceYES12/3/18 Foundation Walls Approved (addition) Footing Dowels or Keyway in placeYES10/25/18 Interior Pier Footings Approved Foundation DampproofingNO Foundation WaterproofingNO Footing Drain Daylight or SumpNO Footing Drain Stone - 12 inch widthNO Footing Drain Stone - 6 inches above footingNO Footing Drain stone - 6 mil polyNO Backfill ApprovalYES12/4/18 Backfill & Foundation Wall Partial Approval (Addition) - 2" Foundation Insulation is approved up to the floor shelf. The 2" insulation needs to continue up shelf to top of foundation wall for proper frost protection. Plumbing Under SlabNO PVC / Cast / CopperNO Dec 10, 2018Page (2) INSPECTION WORKSHEET (BINS-008641-2018) Checklist ItemPassedComments Foundation Insulation Interior / ExteriorNO12/4/18 Backfill & Foundation Wall Partial Approval (Addition) - 2" Foundation Insulation is approved up to the floor shelf. The 2" insulation needs to continue up shelf to top of foundation wall for proper frost protection. Rough Grade 6 inch drop within 10 ft.NO Poly Under SlabNO O'Brien, John (Inspector) Dec 10, 2018Page (3) INSPECTION WORKSHEET (BINS-008463-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0539-2018Permit Case Number:Case Module: Tue Dec 4, 2018Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Foundation Inspector:Inspection Type: 59 WEST MOUNTAIN RD307.-1-29 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName ApplicantMontgomery, Spencer Primary OwnerEast Slope Holding, LP Granted PermissionEast Slope Holding, LP ArchitectAJA Architecture & Planning Checklist ItemPassedComments Building Inspector NotesNO10/25/18 Interior Pier Footings Approved 11/29/18 Footings Approved (addition) 12/3/18 Foundation Walls Approved (addition) 12/4/18 Backfill & Foundation Wall Partial Approval (Addition) - 2" Foundation Insulation is approved up to the floor shelf. The 2" insulation needs to continue up shelf to top of foundation wall for proper frost protection. FootingsYES10/25/18 Interior Pier Footings Approved 11/29/18 Footings Approved (addition) PiersYESInterior piers as per page S203 10/30/18 Monolithic SlabNO Reinforcement in PlaceYES10/25/18 Interior Pier Footings Approved 11/29/18 Footings Approved (addition) Dec 04, 2018Page (1) INSPECTION WORKSHEET (BINS-008463-2018) Checklist ItemPassedComments Foundation / WallpourYES12/3/18 Foundation Walls Approved (addition) Reinforcement in PlaceYES12/3/18 Foundation Walls Approved (addition) Footing Dowels or Keyway in placeYES10/25/18 Interior Pier Footings Approved Foundation DampproofingNO Foundation WaterproofingNO Footing Drain Daylight or SumpNO Footing Drain Stone - 12 inch widthNO Footing Drain Stone - 6 inches above footingNO Footing Drain stone - 6 mil polyNO Backfill ApprovalYES12/4/18 Backfill & Foundation Wall Partial Approval (Addition) - 2" Foundation Insulation is approved up to the floor shelf. The 2" insulation needs to continue up shelf to top of foundation wall for proper frost protection. Plumbing Under SlabNO PVC / Cast / CopperNO Foundation Insulation Interior / ExteriorNO12/4/18 Backfill & Foundation Wall Partial Approval (Addition) - 2" Foundation Insulation is approved up to the floor shelf. The 2" insulation needs to continue up shelf to top of foundation wall for proper frost protection. Rough Grade 6 inch drop within 10 ft.NO Dec 04, 2018Page (2) INSPECTION WORKSHEET (BINS-008463-2018) Checklist ItemPassedComments Poly Under SlabNO O'Brien, John (Inspector) Dec 04, 2018Page (3) INSPECTION WORKSHEET (BINS-008429-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0539-2018Permit Case Number:Case Module: Mon Dec 3, 2018Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Foundation Inspector:Inspection Type: 59 WEST MOUNTAIN RD307.-1-29 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName ArchitectAJA Architecture & Planning Primary OwnerEast Slope Holding, LP ApplicantMontgomery, Spencer Granted PermissionEast Slope Holding, LP Checklist ItemPassedComments Building Inspector NotesNO10/25/18 Interior Pier Footings Approved 11/29/18 Footings Approved (addition) 12/3/18 Foundation Walls Approved (addition) FootingsYES10/25/18 Interior Pier Footings Approved 11/29/18 Footings Approved (addition) PiersYESInterior piers as per page S203 10/30/18 Monolithic SlabNO Reinforcement in PlaceYES10/25/18 Interior Pier Footings Approved 11/29/18 Footings Approved (addition) Foundation / WallpourYES12/3/18 Foundation Walls Approved (addition) Dec 03, 2018Page (1) INSPECTION WORKSHEET (BINS-008429-2018) Checklist ItemPassedComments Reinforcement in PlaceYES12/3/18 Foundation Walls Approved (addition) Footing Dowels or Keyway in placeYES10/25/18 Interior Pier Footings Approved Foundation DampproofingNO Foundation WaterproofingNO Footing Drain Daylight or SumpNO Footing Drain Stone - 12 inch widthNO Footing Drain Stone - 6 inches above footingNO Footing Drain stone - 6 mil polyNO Backfill ApprovalNO Plumbing Under SlabNO PVC / Cast / CopperNO Foundation Insulation Interior / ExteriorNO Rough Grade 6 inch drop within 10 ft.NO Poly Under SlabNO O'Brien, John (Inspector) Dec 03, 2018Page (2)