ComCheck 4.
iCOMcheck Software Version 4.0.8.2
i Envelope Compliance Certificate
•
Project Information R ..._........_______ n
Energy Code: 2015 IECC OCT 2 5 2018
Project Title: Community,Work&Independence, Inc. TOWN OF QUEENSBI vi
Location: Glens Falls, New York
Climate Zone: 6a BUILDING&CODE N 0
Project Type: Alteration Co
Vertical Glazing/Wall Area: 4% CV
O
Construction Site: Owner/Agent: Designer/Contractor: 0
Q
37 Everts Ave. Community Workshop Resources, Gary McCoola •
Queensbury, NY 12804 Inc. Gary McCoola,Architect, PLLC V)
PO Box 303 3 Broad Street-3rd Floor O
Glens Falls, NY 12801 Glens Falls, NY 12801 (V
518-792-0050 Qi M
4 Q --8
Building Area Floor Area T' C Q
1-Office: Nonresidential 8868 N —: W E
O l` O
Envelope Assemblies co 0 co U
R-Value Proposed Max.Allowed
Post-Alteration Assembly
Cavity Cont. U-Factor SHGC U-Factor SHGC
EAST
Exterior Wall 2:Concrete Block:8",Partially Grouted,Cells --- -- --- -- -- ---
Empty,Normal Density,Furring:Metal,[Bldg.Use 1 -Office],
Exemption:Framing cavity filled with insulation.
Window 2:Metal Frame with Thermal Break:Fixed,Other,Fixed, --- — 0.250 0.370 0.360 0.400
Fixed,[Bldg.Use 1 -Office]
Door 1:Glass(>50%glazing):Metal Frame,Entrance Door, -- — 0.250 0.370 0.770 0.400
Entrance Door,Entrance Door,[Bldg. Use 1 -Office]
SOUTH
Exterior Wall 1:Concrete Block:8",Partially Grouted,Cells -- -- --- -- -- ---
Empty,Normal Density,Furring:Metal,[Bldg.Use 1 -Office],
Exemption:Framing cavity filled with insulation.
Window 1:Metal Frame with Thermal Break:Fixed,Tinted,Fixed, -- -- 0.250 0.370 0.360 0.400
Fixed,[Bldg.Use 1 -Office]
(a)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
Envelope PASSES
Envelope Compliance Statement
Compliance Statement: The proposed envelope alteration project represented in this document is consistent with the building
plans, specifications, and other calculations submitted with this permit application.The proposed envelope systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8.2 and to comply with any applicable mandatory
Project Title: Community, Work&Independence,Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\Documents\COMcheck\CWI - Everts Ave.cck Page 1 of 9
requirements listed in the Inspection Checklist. i /
Gary McCoola,AIA i !Co/Z 3//
.17
Name-Title Signature / Date
is
I •t �t c
z'N 7r
k 6di t}'I rAV•4i '.
Project Title: Community, Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\Documents\COMcheck\CWI-Everts Ave.cck Page 2 of 9
COMcheck Software Version 4.0.8.2
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans and/or specifications provide all DComplies Requirement will be met.
[PR1]1 information with which compliance ❑Does Not
can be determined for the building
envelope and document where ❑Not Observable
exceptions to the standard are ❑Not Applicable
claimed.
C402.4.1 The vertical fenestration area <= 30 ❑Complies Requirement will be met.
[PR10]1 percent of the gross above-grade wall ❑Does Not
area. Location on plans/spec: Vertical fenestration area is
❑Not Observable 3.51476660000f above grade wall.
❑Not Applicable
C402.4.1 The skylight area <= 3 percent of the Complies Requirement will be met.
[PR11]1 gross roof area. ❑Does Not
[Not Observable Location on plans/spec: Not applicable.
❑Not Applicable
Additional Comments/Assumptions:
•
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Community,Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\Documents\COMcheck\CWI-Everts Ave.cck Page 3 of 9
Section
Footing/Foundation Inspection Complies? Comments/Assumptions
!& Req.ID
C303.2.1 Exterior insulation protected against ❑Complies Requirement will be met.
[FO6)1 damage,sunlight, moisture,wind, ❑Does Not
landscaping and equipment
maintenance activities. Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 ,Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Community, Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\Documents\COMcheck\CWI-Everts Ave.cck Page 4 of 9
Section
16 # Framing/Rough-In Inspection Complies? Comments/Assumptions
& Req.ID
C303.1.3 Fenestration products rated in DComplies Exception: Default values are used.
[FR12]z accordance with NFRC. ❑Does Not
[Not Observable Location on plans/spec: Section 08 8000: part 2.03 B.
ONot Applicable
C303.1.3 Fenestration products are certified as DComplies Requirement will be met.
[FR13]' to performance labels or certificates ❑Does Not
provided. Location on plans/spec: Section 08 8000: part 2.01 B.
❑Not Observable
• ❑Not Applicable
C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values.
[FR10]' ❑Does Not
❑Not Observable
❑Not Applicable
C402.4.3, Vertical fenestration U-Factor. DComplies See the Envelope Assemblies table for values.
C402.4,3. ❑Does Not
4 ❑Not Observable
[FR8]
❑Not Applicable
C402.4.4 U-factor of opaque doors associated DComplies See the Envelope Assemblies table for values.
[FR14]2 with the building thermal envelope ❑Does Not
meets requirements. ENot Observable
❑Not Applicable
C402.5.1 The building envelope contains a ❑Complies Exception: Requirement does not apply.
[FR16]1 continuous air barrier that is sealed in ❑Does Not
an approved manner and either
constructed or tested in an approved [Not Observable
manner.Air barrier penetrations are ❑Not Applicable
sealed in an approved manner.
C402.5.2, Factory-built fenestration and doors DComplies Exception: Field fabricated fenestration assemblies.
C402.5.4 are labeled as meeting air leakage ❑Does Not
[FR18]3 requirements.
❑Not Observable
❑Not Applicable
C402.5.7 Vestibules are installed on all building DComplies Exception: Doors not intended to be used as a building
[FR17j3 entrances. Doors have self-closing ❑Does Not entrance.
devices.
❑Not Observable Location on plans/spec: A2:Vestibule 3 is for emergency
DNot Applicable exit only.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Community, Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\Documents\COMcheck\CWI-Everts Ave.cck Page 5 of 9
Section
# Mechanical Rough-In Inspection Complies? Comments/Assumptions
'& Req.ID
C402.5.5, Stair and elevator shaft vents have ❑Complies Exception: Requirement does not apply.
C403.2.4. motorized dampers that automatically ❑Does Not
3 close.
[MEW ❑Not Observable
❑Not Applicable
C402.5.5, Outdoor air and exhaust systems have EComplies Exception: Gravity dampers acceptable in buildings 3 stories.
C403.2.4. motorized dampers that automatically ❑Does Not
3 shut when not in use and meet Location on plans/spec: M101: keyed note 4.
[ME5813 maximum leakage rates. Check
gravity dampers where allowed. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Community, Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\Documents\COMcheck\CWI-Everts Ave.cck Page 6 of 9
Section
Insulation Inspection Complies? Comments/Assumptions
'& Req.ID
C303.1 Building envelope insulation is labeled ❑Complies Requirement will be met.
[IN10]2 with R-value or insulation certificate ODoes Not
providing R-value and other relevant
data. ❑Not Observable
❑Not Applicable
C303.2 Above-grade wall insulation installed DComplies Requirement will be met.
[IN7]1 per manufacturer's instructions. Oboes Not
❑Not Observable Location on plans/spec: Section 07 2100: part 3.03.
[Not Applicable
C303.2.1 Exterior insulation is protected from ❑Complies Exception: Requirement does not apply.
[IN14]2 damage with a protective material. ODoes Not
Verification for exposed foundation
insulation may need to occur during ❑Not Observable
Foundation Inspection. ❑Not Applicable
C402.2.3 Above-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values.
[IN6]1 DDoes Not
[Not Observable
❑Not Applicable
C402.2.6 Radiant panels and associated DComplies Exception: Requirement does not apply.
[IN18]3 components, designed for heat ❑Does Not
transfer from the panel surfaces to the ❑Not Observable
occupants or indoor space are
insulated with a minimum of R-3.5. ❑Not Applicable
C402.5.1. All sources of air leakage in the DComplies Requirement will be met.
1 building thermal envelope are sealed, ODoes Not
[IN1]1 caulked, gasketed, weather stripped Location on plans/spec: A7: window details.
or wrapped with moisture vapor- ❑Not Observable
permeable wrapping material to ❑Not Applicable
minimize air leakage.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Community,Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\Documents\COMcheck\CWI-Everts Ave.cck Page 7 of 9
Section
Final Inspection Complies? Comments/Assumptions
'& Req.ID
C402.5.3 Where open combustion air ducts ❑Complies Exception: Requirement is not applicable.
[F151]3 provide combustion air to open ❑Does Not
combustion fuel burning appliances,
•
the appliances and combustion air ❑Not Observable
opening are located outside the ❑Not Applicable
building thermal envelope or enclosed
in a room, isolated from inside the
thermal envelope. Such rooms are
sealed and insulated.
C402.5.6 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply.
[FI37]1 dock cargo doors. ❑Does Not
['Not Observable
❑Not Applicable
C402.5.8 Recessed luminaires in thermal ❑Complies Exception: Requirement does not apply.
[F126]3 envelope to limit infiltration and be IC EDoes Not
rated and labeled. Seal between
interior finish and luminaire housing. :Not Observable
ENot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Community, Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\Documents\COMcheck\CWI-Everts Ave.cck Page 8 of 9
i
COMcheck Software Version 4.0.8.2
Interior Lighting Compliance Certify
Project Information5
D ^ p
Energy Code: 2015 IECC OCT L 201v
Project Title: Community, Work& Independence, Inc.
Project Type: Alteration TOWN OF QUEENSBURY
BUILDING&CODES
Construction Site: Owner/Agent: Designer/Contractor:
37 Everts Ave. Community Workshop Resources, Gary McCoola
Queensbury, NY 12804 Inc. Gary McCoola,Architect, PLLC
PO Box 303 3 Broad Street-3rd Floor
Glens Falls, NY 12801 Glens Falls, NY 12801
518-792-0050
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
1-Office 8868 0.82 7272
Total Allowed Watts= 7272
Proposed Interior Lighting Power
A B C D E
Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Office(8868 sq.ft,)
LED 2:A:2X4 LENSED 4000 LUMENS:Other: 1 89 30 2670
LED 4:B:2X2 LENSED 2000 LUMENS:Other: 1 18 19 342
LED 9:D:6"DOWNLIGHT 1000 LUMENS:Other: 1 4 13 52
LED 5:D1:6"DOWNLIGHT 1500 LUMENS:Other: 1 12 21 252
Total Proposed Watts= 3316
Interior Lighting PASSES
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8.2 and to comply with any
applicable mandatory requirements listed in the Inspection Checklis .
Name-Title Signature / Date
`
its
z11' wo- T
`.'SOP N
ee
Project Title: Community, Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\AppData\Local\Microsoft\Windows\INetCache\IE\KC09LLPC\CWI -Everts Ave.cck Page 1 of 5
COMcheck Software Version 4.0.8.2
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 60.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section
Plan Review Complies? Comments/Assumptions
& Req.JD
C103.2 Plans, specifications, and/or lComplies Requirement will be met.
[PR4]' calculations provide all information ❑Does Not
with which compliance can be
determined for the interior lighting [Not Observable
and electrical systems and equipment Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Community, Work& Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\AppData\Local\Microsoft\Windows\INetCache\IE\KCO9LLPC\CWI- Everts Ave.cck Page 2 of 5
•
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
&Req,ID
C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met.
[EL15]' reduce the lighting load by at least ❑Does Not
50%. :Not Observable
❑Not Applicable _
C405.2.1 Occupancy sensors installed in ❑Complies Requirement will be met.
[EL18]' required spaces. ❑Does Not
:Not Observable
❑Not Applicable
C405.2.1, Independent lighting controls installed ❑Complies Requirement will be met.
C405.2.2. per approved lighting plans and all ❑Does Not
3 manual controls readily accessible and
[EL23]2 visible to occupants. ❑Not Observable
❑Not Applicable
C405.2.2. Automatic controls to shut off all ❑Complies Requirement will be met.
1 building lighting installed in all ❑Does Not
[EL22]2 buildings. [Not Observable
[Not Applicable
C405,2.3 Daylight zones provided with ❑Complies Exception: Requirement does not apply.
[EL16]2 individual controls that control the ❑Does Not
lights independent of general area
lighting. ❑Not Observable
❑Not Applicable
C405.2.3, Primary sidelighted areas are ❑Complies Exception: Requirement does not apply.
C405.2.3. equipped with required lighting DDoes Not
1, controls.
C405.2.3. [Not Observable
2 ❑Not Applicable
[EL20]'
C405.2.3, Enclosed spaces with daylight area EComplies Exception: Requirement does not apply.
C405.2.3. under skylights and rooftop monitors ❑Does Not
1, are equipped with required lighting ❑Not Observable
C405.2.3. controls.
3 ONot Applicable
[EL21]'
C405.2.4 Separate lighting control devices for ❑Complies Requirement will be met.
[EL4)' specific uses installed per approved ❑Does Not
lighting plans.
❑Not Observable
❑Not Applicable
C405.2.4 Additional interior lighting power ❑Complies Requirement will be met.
[EL8]' allowed for special functions per the ['Does Not
approved lighting plans and is
automatically controlled and ❑Not Observable
separated from general lighting. ❑Not Applicable
C405.3 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met.
(EL6]' face. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) J
Project Title: Community, Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\AppData\Local\Microsoft\Windows\INetCache\IE\KCO9LLPC\CWI- Everts Ave.cck Page 3 of 5
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID
C303.3, Furnished O&M instructions for ❑Complies Requirement will be met.
C408.2.5. systems and equipment to the ❑Does Not
2 building owner or designated
[FI17)3 representative. ENot Observable
❑Not Applicable
C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values.
[F118)' lighting power is consistent with what ❑Does Not
is shown on the approved lighting
plans, demonstrating proposed watts ['Not Observable
are less than or equal to allowed Observable,_,
Applicable
watts.
C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met.
1 electric power systems within 90 days ODoes Not
[FI16]3 of system acceptance. ❑Not Observable
❑Not Applicable
C408.3 Lighting systems have been tested to ❑Complies Requirement will be met.
[F133]' ensure proper calibration, adjustment, ❑Does Not
programming, and operation.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
`11High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact (Tier 3) 1
Project Title: Community, Work& Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\AppData\Local\Microsoft\Windows\1NetCache\IE\KC09LLPC\CWI- Everts Ave.cck Page 4 of 5
COMcheck Software Version 4.0.8.2
Exterior Lighting Compliance Certific - -
ECEpVC
Project Information
Energy Code: 2015 IECC OCT 2 5 2018
Project Title: Community,Work& Independence, Inc. ,
Project Type: Alteration TOWN OF OUEENSBURY
Exterior Lighting Zone 2(Light industrial area with limited nighttime us BUILDING&CODES
Construction Site: Owner/Agent: Designer/Contractor:
37 Everts Ave. Community Workshop Resources, Gary McCoola
Queensbury, NY 12804 Inc. Gary McCoola,Architect, PLLC
PO Box 303 3 Broad Street-3rd Floor
Glens Falls, NY 12801 Glens Falls, NY 12801
518-792-0050
Allowed Exterior Lighting Power
A B C D E
Area/Surface Category Quantity Allowed Tradable Allowed Watts
Watts/Unit Wattage (B X C)
Entry canopy 354 ft2 0.25 Yes 88
Total Tradable Watts(a)= 88
Total Allowed Watts= 88
Total Allowed Supplemental Watts(b)= 600
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Entry canopy(354 ft2): Tradable Wattage
LED 5:D1:6"DOWNLIGHT 1500 LUMENS:Other: 1 3 21 63
Total Tradable Proposed Watts= 63
Exterior Lighting PASSES
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting
systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8,2 and to comply with any
applicable mandatory requirements listed in the Inspection Chec ist.
--K.._ /0/Z 3/cS
Name-Title `r db j�," ,, Signature 1 Date
L/(Y/�.
, yi.
a
t.4e
Project Title: Commun , ork&'Independence, Inc. Report date: 10/23/18 •
Data filename: C:\Users\Gary\AppData\Local\Microsoft\Windows\INetCache\IE\KCO9LLPC\CWI-Everts Ave.cck Page 1 of 5
•
COMcheck Software Version 4.0.8.2
I• nspection Checklist
. V Energy Code: 2015 IECC
Requirements: 60.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans, specifications, and/or ❑Complies Requirement will be met.
[PR8]i calculations provide all information ❑Does Not
with which compliance can be
determined for the exterior lighting ❑Not Observable
and electrical systems and equipment DNot Applicable
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact (Tier 3)
Project Title: Community, Work& Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\AppData\Local\Microsoft\Windows\INetCache\IE\KCO9LLPC\CWI- Everts Ave.cck Page 2 of 5
Section
Rough-In Electrical Inspection Complies? Comments/Assumptions
. & Req.ID
C405.2.5 Automatic lighting controls for exterior ElComplies Requirement will be met.
[EL25]no0 lighting installed. Controls will be EDoes Not
daylight controlled, set based on
business operation time-of-day, or [Not Observable
reduce connected lighting > 30%. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3JLow Impact (Tier 3)
Project Title: Community, Work& Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\AppData\Local\Microsoft\Windows\INetCache\IE\KC09LLPC\CWI - Everts Ave.cck Page 3 of 5
Section •
Final Inspection Complies? Comments/Assumptions
& Req.ID
C405.5,1 Exterior lighting power is consistent Complies See the Exterior Lighting fixture schedule for values.
[FI19)1 with what is shown on the approved DDoes Not
lighting plans, demonstrating
proposed watts are less than or equal Not Observable
to allowed watts. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Community, Work&Independence, Inc. Report date: 10/23/18
Data filename: C:\Users\Gary\AppData\Local\Microsoft\Windows\INetCache\IE\KC09LLPC\CWI- Everts Ave,cck Page 4 of 5