ResCheck gGenerated by REScheck-Web Software
i, Compliance Certificate
Project McCoslin Residence 5ECEIVErn)
Energy Code: 2015 IECC
Location: Warren County, New York fI� DEC 0 4 2018 Construction Type: Single-family Ll
Project Type: Alteration
Climate Zone: 6 (8499 HDD) TOWN OF QUEENSBURY
Permit Date: COMMUNITY DEVELOPMENT
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
65 Rockhurst Road Mary McCoslin AND:Architecture&Design
Queensbury, New York 12804 46 Brown's Path mark@and-architecture.com
Queensbury, NY 12804
ompliance Passes using prescriptive requirements for alteration projects
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or U-Factor UA
Perimeter R-Value R-Value
Ceiling:Cathedral Ceiling(no attic) --- --- --- --- ---
Exemption: Framing cavity filled with insulation
Wall: Wood Frame, 16"o.c. --- --- --- --- ---
Exemption: Framing cavity filled with insulation
Basement:Masonry Block w/Empty Cells 592 21.0 0.0 0.048 28
Wall height:8.0'
Depth below grade: 5.0'
Insulation depth:8.0'
Window:Wood Frame 170 0.270 46
Door:Solid Door(under 50%glazing) 18 0.270 5
Door: Glass Door(over 50%glazing) 146 0.280 41
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version: REScheck-Web and to comply with the m tory-requirements lied in the REScheck Inspection Checklist.
Name-Title ' - • ` ` ° Signature ,p-t.0 /i le Date
%&' \1NONY o'
41
227.13-2-30 RC-0764-2018 , .}` -i
•
McCoslin, Mary -t�' y tit Ar
-
65 Rockhurst Rd ci;,, ¢-
Residential Alterations 832 s.f. ii3
O.&:i0
Project Title: McCoslin Residence Report date: 11/30/18
Data filename: Page 1 of 9
e. REScheck Software Versions REScheck-Web
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified Complies? Comments/As5umptiotts
# Pre-Inspection/Ptah Review Value - Value
&RegID
103.1, :Construction drawings and iOComplies
103.2 documentation demonstrate ODoes Not
[PR1]1 energy code compliance for the ;[]Not Observable
building envelope.Thermal lC7Not Applicable
:envelope represented on
construction documents.
103.1, ;Construction drawings and OComplies
103.2, ;documentation demonstrate Does Not
403.7 ;energy code compliance for ONot Observable
(PR3P ;lighting and mechanical systems. :Not Applicable
Systems serving multiple
:dwelling units must demonstrate
Icompliance with the IECC
!Commercial Provisions.
302.1, ;Heating and cooling equipment is i Heating: Heating: ;DComplies
403.7 sized per ACCA Manual S based Btu/hr , Btu/hr ;ODoes Not
[PR212 on loads calculated per ACCA Cooling: Cooling: ;ONot Observable
,: Manual j or other methods Btu/hr Btu/hr ONot Applicable
;approved by the code official.
Additional Comments/Assumptions:
1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McCoslin Residence Report date: 11/30/18
Data filename: Page 2 of 9
Section
Plans Verified Field Verified )
# Foundation Inspection Complies? Comments/Assumptions
& Re ID. Value Value
Req.ID
'Conditioned basement wall R- R- ;DComplies See the Envelope Assemblies
[F04]1 :insulation R-value.Where interior R- R- DDoes Not table for values.
9) insulation is used,verification ; Not Observable
may need to occur during
!Insulation Inspection. Not DNot Applicable
;required in warm-humid locations;
in Climate Zone 3.
303.2 ;Conditioned basement wall DComplies
[F0511 :insulation installed per ❑Does Not
4, ;manufacturer's instructions. :Not Observable
i - DNot Applicable
402.2.9 ;Conditioned basement wall ft ft lElComplies See the Envelope Assemblies
[F06)1 ;insulation depth of burial or - "ODoes Not 'table for values.
;distance from top of wall.
ONot Observable
ONot Applicable
303.2.1 A protective covering is installed <DComplies
[FO1l]2 ':to protect exposed exterior ODoes Not
insulation and extends a
-DNot Observable
-;,minimum of 6 in. below grade.
DNot Applicable
403.9 ;Snow-and ice-melting system • `.DComplies
[F012]2 controls installed. DDoes Not
DNot Observable
ONot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1
Project Title: McCoslin Residence Report date: 11/30/18
Data filename: Page 3 of 9
Section Plans Verified field Verified
# Framing/Rough-In inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, ,Door U-factor. U- U- '❑Complies See the Envelope Assemblies
402.3.4 !❑Does Not table for values.
(FR1]1 •
;❑Not Observable
9 ;❑Not Applicable
402.1.1, ',Glazing U-factor(area-weighted ; U- U- ❑Complies ;See the Envelope Assemblies
402.3.1, 'average). ❑Does Not table for values.
402.3.3,
402.5 ❑Not Observable
[FR2]1 ❑Not Applicable
303.1.3 ;U-factors of fenestration products: '.❑Complies
[FR4]1 :are determined in accordance ❑Does Not
with the NFRC test procedure or ❑Not Observable
;taken from the default table.
I❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ':❑Does Not
instructions.
❑Not Observable
Not Applicable
402.4.3 ;Fenestration that is not site built ❑Complies
[FR2O]1 :is listed and labeled as meeting : .❑Does Not
J AAMA/WDMA/CSA 101/I.S.2/A440,
,or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
'limits.
402.4.5 'IC-rated recessed lighting fixtures - ❑Compiles
[FR16]2 ,sealed at housing/interior finish '❑Does Not
and labeled to indicate s2.0 cfm
leakage at 75 Pa. `❑Not Observable
❑Not Applicable
403.3.1 ',Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
R-6 where<3 inches.Supply and- -,❑Not Observable
return ducts in other portions of ':❑Not Applicable
"the building insulated>= R-6 for
'diameter>=3 inches and R-4.2
for< 3 inches in diameter.
403.3.5 :Building cavities are not used as !❑Complies
[FR15)3 ducts or plenums. ❑Does Not
-'❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ;❑Complies
[FR17]2 above 105°F or chilled fluids i❑Does Not
below 55°F are insulated to>R-
3, :DNot Observable
;DNot Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
4 ;❑Not Observable
❑Not Applicable
4035.3 Hot water pipes are insulated to , R- R- :❑Complies
[FR18]2 R-3. ❑Does Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are. ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
1'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McCoslin Residence Report date: 11/30/18
Data filename: ?aae 4 of 9
Section Plans Verified Field Verified Complies? Comments/Assumptions
# Insulation Inspection Value Value
& Req.tD
303.1 All installed insulation is labeled '[Complies
[IN1312 or the installed R-values ❑Does Not
'provided. ;[Not Observable
`� i[Not Applicable
402.1.1, `Wall insulation R-value. If this is a. R- R- [Complies :See the Envelope Assemblies
402.2.5, �mass wall with at least'/z of the 0 Wood ❑ Wood
Does Not table for values.
402.2.6 wall insulation on the wall [ Mass 0 Mass [Not Observable :.
[IN3)1 ':exterior,the exterior insulation 0 Steel 0 Steel ,[Not Applicable
requirement applies(FR10).
303.2 Wall insulation is installed per DComplies
[IN4I1 manufacturer's instructions. [Does Not
;[Not Observable I
DNot Applicable
Additional Comments/Assumptions:
1 IHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McCoslin Residence Report date: 11/30/18
Data filename: Page 6 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Regal
402.1.1, ;Ceiling insulation R-value. R- R- '❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood 0 Wood ❑Does Not table for values.
402.2.2, Steel
402.2.E ❑ ❑ Steel ;❑Not Observable
[FI1]1 ❑Not Applicable
303.1.1.1„Ceiling insulation installed per "r `❑Complies
303.2 :manufacturer's instructions. : - '❑Does Not
[FI2]1 !Blown insulation marked every
300 ft2. '❑Not Observable
❑Not Applicable
402 2 3 ',Vented attics with air permeable , ; ,- ❑Complies
[FI22]2 insulation include baffle adjacent €:'. ❑Does Not
;to soffit and eave vents that :
extends over insulation. t';_ ❑Not Observable
❑Not Applicable
402.2.4 ;Attic access hatch and door R- R- ;❑Complies
[FI3]1 ;insulation e_R-value of the ;❑Does Not
;adjacent assembly.
❑Not Observable
ONot Applicable
402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ;❑Complies
[FI17]1 ach in Climate Zones 1-2,and ODoes Not
<=3 ach in Climate Zones 3-8. ONot Observable
❑Not Applicable
403.3.4 ;Duct tightness test result of<=4 cfm/100 cfm/100 '❑Complies
[Fi4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air ❑Not Observable
handler @ 25 Pa. For rough-in
tests,verification may need to ❑Not Applicable
;occur during Framing Inspection.
403.3.3 •Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[FI27]1 :determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ;❑Not Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
;leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
'handler enclosure.
403.3.2.1 ;Air handler leakage designated IDComplies
[F124]1 by manufacturer at<=2%of ;❑Does Not
design air flow.
[Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[FI9]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications. ❑Not Applicable
403.1.2 .Heat pump thermostat installed ❑Complies
[FI10]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies
[Fill]2 systems have automatic or EDoes Not
accessible manual controls.
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McCoslin Residence Report date: 11/30/18
Data filename: Page 7 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
403.6.1 All mechanical ventilation system ❑Complies
[F125)2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy ❑Not Observable
and air flow limits.
❑Not Applicable
403.2 .Hot water boilers supplying heat ❑Complies
[F126]2 through one-or two-pipe heating I,C3Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor `❑Not Applicable
temperature. •
403.5.1.1 Heated water circulation systems : ❑Complies
(F128]2 :have a circulation pump.The ❑Does Not
;system return pipe is a dedicated ❑Not Observable
return pipe or a cold water supply
;pipe. Gravity and thermos- ❑Not Applicable
,syphon circulation systems are I
not present.Controls for
.circulating hot water system -
pumps start the pump with signal
;for hot water demand within the
:occupancy.Controls
automatically turn off the pump
when water is in circulation loop
;is at set-point temperature and
no demand for hot water exists.
403.5.1.2 'Electric heat trace systems '❑Complies
[F129]2 comply with IEEE 515.1 or UL }❑Does Not
515.Controls automatically Not Observable
adjust the energy input to the ❑
heat tracing to maintain the Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that • ❑Complies
[F130]2. have recirculation pumps that ElDoes.Not
pump water from a heated water
:supply pipe back to the heated "' ;❑Not Observable
water source through a cold Not Applicable
water supply pipe have a
',demand recirculation water
system. Pumps have controls
'that manage operation of the
pump and limit the temperature
of the water entering the cold
:water piping to 1044F.
403.5.4 Drain water heat recovery units ❑Complies
(Fi31] 'tested In accordance with C5A
B55.1.Potable water-side Does Not
pressure loss of drain water heat -❑Not Observable
recovery units <3 psi for '❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ;OComplles
[FI6]1 !fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[FI23]3 'no continuous pilot light. =❑Does Not
❑Not Observable
❑Not Applicable
1 [High Impact(Tier 1) 12 [Medium Impact(Tier 2) 13 [Low Impact(Tier 3) I
Project Title: McCoslin Residence Report date: 11/30/18
Data filename:
?age 8 of 9
Section
# Final Inspection Provisions Plans Verified Field Verified
(& Req.ID Value Value Complies? Comments/Assumptions
1401.3 Compliance certificate posted.
1F17J2 _Complies
DDoes Not
:Not Observable
[7Not Applicable
303.3 Manufacturer manuals for
[FI1813 mechanical and water heating DComplies
;systems have been provided. Does Not
[]Not Observable
ENot Applicable
Additional Comments/Assumptions:
1(High Impact(Tier 1) 12 I Medium Impact(Tier 2) 13 I Low Impact(Tier 3)
1
Project Title: McCoslin Residence
Report date: 11/30/18
Data filename:
Page 9 of 9
2 Energy,Ejte Eff15IECC
ici ency Certificate
Insulation Rating R-Value
Above-Grade Wall 0.00
Below-Grade Wall 21.00
Floor 0.00
Ceiling / Roof 0.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.27
Door 0.28
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments