2019-10-30 Final Envelope Testing Report O'Reilly Auto Parts Queensbury27 Cohoes Road Watervliet, New York 12189 | 518.874.1604 | Fax 212.731.0372| www.thepakatargroup.com October 30, 2019 Visible Construction 7 High Street Huntington, NY 11743 RE: Energy Code Compliance Testing Verification PROECT: O'Reilly Auto Parts, 682 Glen Street, Queensbury, NY PERMIT #: NA To whom it may concern, As per your request we have conducted the following Energy Code Compliance Inspections and/or tests. ☐Thermal Bypass Inspection, prior to insulation installation ☐Duct Tightness Testing when applicable ☒Infiltration and Air Leakage Testing (Blower Door Test) The purpose of our testing/inspections are to provide independent verification of as built conditions as they specifically relate to the applicable version of the adopted energy code. We are not in any way responsible for the means, methods, materials or equipment used in constructing this Commercial Building and make no warranty as to their suitability for such. Our testing and/or inspections are in accordance with the applicable version of the International Energy Conservation Code, ASTM Testing Protocols, Building Performance Institute Standards, and Resnet Standards for these tests/inspections. Equipment used for this report includes: ✓Retrotec Blower Door, Model # 5000 (2 used) ✓Retrotec Blower Door, Model #1000 ✓Flir Infrared Imager Model C2 All equipment used for these testing/inspections have current and valid calibrations as specified by the manufacturer. All technicians completing this work hold current and valid certifications as noted on the report documents. The following data was obtained during testing on October 30 , 2019: Floors: 0 SF Envelope Properties: Walls: 5,640 SF Roof: 7,453 SF Total: 13,093 SF Allowed Infiltration: 0.40cfm/sf or 5,237cfm at 75 PA Confirmed Actual Infiltration: 0.36cfm/ sf or 4,840cfm at 75 PA Based on our confirmed testing your commercial building is in compliance with 2016 Energy Conservation Construction Code, Section C402.5 Air Leakage- thermal envelope. Thank you for choosing The Pakatar Group, LLC for your energy consulting needs. Respectfully submitted, The Pakatar Group, LLC By: Alexander Pakatar, NEBB BET Professional