final 04122019INSPECTION WORKSHEET (001936-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0160-2018Case Module:Permit
Inspection Date:Fri Apr 12, 2019Inspection Status:Partial Pass
Inspector:Charles DyerInspection Type:Residential Final Inspection
Job Address:75 Overlook DRParcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantLingel, Tyler
ContractorT.P. Monahan, Inc.
Primary OwnerLingel, Tyler
Granted PermissionLingel, Tyler
ArchitectRucinski-Hall Architecture
Checklist ItemPassedComments
General CommentsNO1. Return handrails into wall
2. Provide thermal barrier at exposed foam at utility area
3.provide final electric
4/12/19 for temp C/O conditions- 1. Complete deck rear of
home
2. Provide final
grade-6"-10' from foundation
3. Change out
range hood to meet requirements of make up air.
4 inch Building Number Address visible from roadYES
Chimney Height / B Vent / Direct Vent LocationNO
Chimney Rain Cap InstalledNO
Apr 12, 2019Page (1)
INSPECTION WORKSHEET (001936-2019)
Checklist ItemPassedComments
Fresh Air IntakeYES
Fresh air supply 3' from gradeYES
3" Plumbing Vent through roof minimum 18 inchYES
Outside Spigots have Air GapYES
Roof Complete / Exterior Finish CompleteYES
Platform at all exterior doorsYES
Handrail 4 or more risersYESReturn into wall
Guards at stairs,decks,patios 30" + above gradeNO
Guard at stairwell at 34" or moreYES
Window guards req:<2' above floor/6' aboveYES
grade - quick release installed
Guard at deck, porches 36" or moreNOCondition for temp CO / deck to be constructed at later date
Handrail Termination at Newell Post or WallYES
Interior/Exterior Railings 34 to 38YES
Wood deck: 2'+ from grade dia bracing required -NO
H/C ramp compliant
4+ Deck Joist Ledger Connections-24" FromNO
Ends
Apr 12, 2019Page (2)
INSPECTION WORKSHEET (001936-2019)
Checklist ItemPassedComments
Deck Ledger-Bolted per CodeNO
Grade away from foundation: 6" down, 10' outNOWork in progress
6" clearance to sill plateYES
Gas Shut-off Exposed & Regulator (18) AboveYES
Grade
HVAC Vent Terminal 10' from Lot Line &YES
Openings
Interior privacy/trim/doors/main entrance 36YES
Bathroom / Kitchen WatertightYES
Low flow toilet 1.3 gal/flushing cycle -YES
showerhead/faucet
Safety glazing: w/in 5' of tub/shower - stairwellYES
win/adj to drs
Smoke Detectors: Carbon MonoxideYES
Smoke Detectors 3' from Kitchens & Baths R314YES
Every level, Every bedroomYES
Outside every bedroom areaYES
Inter ConnectedYES
Apr 12, 2019Page (3)
INSPECTION WORKSHEET (001936-2019)
Checklist ItemPassedComments
Battery backup: _____YES
Attic Access 22 x 30 minimumYES
Attic Access Insulation = Attic R- ValueYES
Attic Access GasketedYES
Bathroom Fans, if no windowYES
Plumbing fixturesYES
Backflow Preventors where requiredYES
Foundation insulation to floorYES
Energy Sticker on Elec. Panel:R-Val. & HeatingYESProvide certification of insulation
Sys
All Hot Water Systems: R-3YES
Duct work sealed properlyYES
Intake OpeningsYES
Range Hood 400+ cfm-Fresh Air REQUIREDYES
Blower Door Test CertificationYES
HRV or ERV Installed per Bedroom RequirementsYES
Apr 12, 2019Page (4)
INSPECTION WORKSHEET (001936-2019)
Checklist ItemPassedComments
Emergency egress below gradeYES
Furnace shut-off w/in 30 ft. or w/in line of siteYES
Propane Tank: Proper Setback from PropNO
Line/Struct
Furnace Hot Water Heater operatingYES
Relief Valve ,Heat Trap/Water Temp 110 deg orYES
less
Encl. Stairs Sheetrock Underside minimum ½NO
Gypsum
1/2" Gypsum or House Wall and GableYES
20 Minute Fire Door/Self-Closing HardwareYES
Seals on Garage Doors, esp. WoodYES
Basement stairs closed rise greater than 4 inchesYES
Basement Egress: 5s.f. window w/sill or BilcoYES
door
Basement ceiling covered 2x8 fl joist or lessYES
Jack posts in basement lagged at top and bottomYESProvide bracing at LVL's basement
Verified 4/12/19
Garage Floor PitchedYES
Apr 12, 2019Page (5)
INSPECTION WORKSHEET (001936-2019)
Checklist ItemPassedComments
1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl.YES
Truss
Gas Log In Sealed or Glass EnclosureYES
Fin Elect; Energy Saving Light Bulbs 50 PercentYES
CSST/other piping in conduit if buried,if requiredYES
Final Survey Plot PlanYES
Arc Fault Breaker Habitable SpacesYES
Flex Gas Pipe BondingYES
As Built Septic SystemYES
Site Plan / Variance requiredNO
Flood Plain Certification, if requiredNO
Fuel Tanks above flood plain elevationNO
Buried Fuel Tanks anchored in flood zoneNO
Truss ID Signage Installed at Electrical MeterYES
OK to Issue Temporary C/OYESSee conditions top of page 4/12/19
OK to Issue C/ONO
Dyer, Charles (Inspector)
Apr 12, 2019Page (6)