foundation 08282018INSPECTION WORKSHEET (BINS-006185-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:Case Module:
RC-0160-2018Permit
Inspection Date:Inspection Status:
08/28/2018Partial Pass
Inspector:Inspection Type:
Charles DyerBuilding Foundation
Job Address:Parcel Number:
103 ROCKWELL RD
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantLingel, Tyler
ContractorT.P. Monahan, Inc.[T.P. Monahan, Inc.]
Primary OwnerLingel, Tyler
Granted PermissionLingel, Tyler
ArchitectRucinski-Hall Architecture[Rucinski-Hall Architecture] ,
Checklist ItemPassedComments
Building Inspector NotesNOPlease have stamped plans from town onsite
FootingsYESFor garage with 2#4's continuous Approved 8/28/18
PiersNO
Monolithic SlabNO
Reinforcement in PlaceNO
Reinforcement in PlaceNO
Foundation / WallpourYESFor front porch, partial pour with one row continuous
with verticals 8/28/18
Footing Dowels or Keyway in placeYES
Foundation DampproofingYES
Foundation WaterproofingNO
Footing Drain Daylight or SumpYES
Footing Drain Stone - 12 inch widthYES
Footing Drain Stone - 6 inches above footingYES
Footing Drain stone - 6 mil polyNO
Backfill ApprovalYES
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Aug 28, 2018Page (1)
INSPECTION WORKSHEET (BINS-006185-2018)
Checklist ItemPassedComments
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabNO
Dyer, Charles (Inspector)
Aug 28, 2018Page (2)