foundation 08172018INSPECTION WORKSHEET (BINS-005981-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:Case Module: RC-0160-2018Permit Inspection Date:Inspection Status: 08/17/2018Passed Inspector:Inspection Type: Charles DyerBuilding Foundation Job Address:Parcel Number: 103 ROCKWELL RD Queensbury, NY 12804 Contact TypeCompany NameName Primary OwnerLingel, Tyler ArchitectRucinski-Hall Architecture, ApplicantLingel, Tyler Granted PermissionLingel, Tyler ContractorT.P. Monahan, Inc., Checklist ItemPassedComments Building Inspector NotesNO FootingsYESWith 2 rows # 4 continuous Approved 8/10/18 PiersYES Monolithic SlabNO Reinforcement in PlaceNO Reinforcement in PlaceNO Foundation / WallpourYESWith 2 rows of # 4 continuous top and bottom Footing Dowels or Keyway in placeYESWet sticking Vertical 4 oc Foundation DampproofingNO Foundation WaterproofingNO Footing Drain Daylight or SumpNO Footing Drain Stone - 12 inch widthNO Footing Drain Stone - 6 inches above footingNO Footing Drain stone - 6 mil polyNO Backfill ApprovalNO Plumbing Under SlabNO PVC / Cast / CopperNO Foundation Insulation Interior / ExteriorNO Aug 17, 2018Page (1) INSPECTION WORKSHEET (BINS-005981-2018) Checklist ItemPassedComments Rough Grade 6 inch drop within 10 ft.NO Poly Under SlabNO Dyer, Charles (Inspector) Aug 17, 2018Page (2)