Loading...
ComCheck COMcheck Software Version 4.1.1.0 ii Interior Lighting Compliance Certificate ipil REVIEWED FOR TECEOWER Project Information ENERGY CODE COMPLIANCE Energy Code: 2015 IECC I JAN 2 3 2019 1 [1..j Project Title: Five Guys Queensbury Interior Renovation Project Type: Alteration TOWN OF QUEENSBURY BUILDING&CODES Construction Site: r/Agent: Designer/Contractor: 735 Upper Glen Stre C2 Architecture Queensbury, NY r �C G p 340 Broadway r G Schenectady, NY 12305 �-- 518-320-8250 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Common Space Types:Dining Area-Family Restaurant 1704 0.89 1517 2-Common Space Types:Restrooms 100 0.98 98 3-Common Space Types:Food Preparation 1040 1.21 1258 Total Allowed Watts= 2873 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Common Space Types:Dining Area-Family Restaurant(1704 sq.ft.) LED 2:LED Other Fixture Unit 28W: 3 31 30 930 LED 3:LED PAR 8W: 1 32 8 256 Track lighting 1:Wattage based on 6 feet of trac: Wattage based on 6 feet of track 0 0 180 180 Common Space Types:Restrooms(100 sq.ft.). LED 2:LED Other Fixture Unit 28W: 3 2 30 60 Common Space Types:Food Preparation (1040 sq.ft.) LED 1:LED Panel 44W: 3 19 45 855 Total Proposed Watts= 2281 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspectio Checklist. Michael A Roman, Principal /2 (kA1/22/2019 Name-Title S gnature Date Project Title: Five Guys Queensbury Interior Renovation Report date: 01/22/19 Data filename: R:\2018 Projects\1826 Five Guys Queensbury\Correspondence\FG Queensbury-Lighting Page 1 of 5 Compliance.cck COMcheck Software Version 4.1.1.0 II Inspection Checklist Energy Code: 2015 IECC IPA Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications, and/or ❑Complies (PR4)1 calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed.Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Five Guys Queensbury Interior Renovation Report date: 01/22/19 Data filename: R:\2018 Projects\1826 Five Guys Queensbury\Correspondence\FG Queensbury-Lighting Page 2 of 5 Compliance.cck Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.1 Lighting controls installed to uniformly ❑Complies [EL15]1 reduce the lighting load by at least ❑Does Not 50%. [Not Observable ❑Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies [EL18]1 required spaces. ❑Does Not ❑Not Observable ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies�� C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and Not Observable [EL23]2 visible to occupants. ❑ ❑Not Applicable C405.2.2. Automatic controls to shutoff all ❑Complies 1 building lighting installed in all ❑Does Not [EL22]z buildings. [Not Observable ❑Not Applicable C405.2.3 Daylight zones provided with ❑Complies [EL16]z individual controls that control the ❑Does Not lights independent of general area lighting. DNot Observable ❑Not Applicable C405.2.3, Primary sidelighted areas are ❑Complies C405.2.3. equipped with required lighting ElDoes Not 1, controls. ❑Not Observable C405.2.3. 2 ❑Not Applicable (EL20]1 C405.2.3, Enclosed spaces with daylight area ❑Complies C405.2.3. under skylights and rooftop monitors ❑Does Not 1, are equipped with required lighting C405.2.3. controls. ['Not Observable 3 ❑Not Applicable [EL21]1 C405.2.4 Separate lighting control devices for ❑Complies [EL4]1 specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ❑Not Applicable C405.2.4 Additional interior lighting power ❑Complies [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and Not Observable separated from general lighting. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies [EL6]1 face. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Five Guys Queensbury Interior Renovation Report date: 01/22/19 Data filename: R:\2018 Projects\1826 Five Guys Queensbury\Correspondence\FG Queensbury-Lighting Page 3 of 5 Compliance.cck Section Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for ❑Complies C408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated [FI17]3 representative. ❑Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts ❑Not Observable are less than or equal to allowed ❑Not Applicable watts. C408.2.5. Furnished as-built drawings for ❑Complies 1 electric power systems within 90 days ❑Does Not [FI16]3 of system acceptance. ❑Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to EComplies [FI33]1 ensure proper calibration,adjustment, ❑Does Not programming,and operation. ENot Observable ElNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Five Guys Queensbury Interior Renovation Report date: 01/22/19 Data filename: R:\2018 Projects\1826 Five Guys Queensbury\Correspondence\FG Queensbury-Lighting Page 4 of 5 Compliance.cck