ResCheck REScheck Software Version 4.6.5 r
Compliance Certificate i .µ
; FEB 2 p 2019 ,
FILE COPY comma, `�� ..
Project The Hawthorn OF NEW 'ITY �_,,, i U„0°
4% o RirAt u YQ ;;
op
Energy Code: 2015 IECC COy°, .v. �� ��15+,, * • ���`
Location: Glens Falls, New York , * 1
Construction Type: Single-family r- " ` cr
05
Project Type: New Construction t7 `cit y - is
Conditioned Floor Area: 1,658 ft2 +!s ..�r-� w O 9—;
Glazing Area 15% �� �/ �• N N
6 (7635 HDD) I Ogg. „ CO V
Climate Zone: cci
L�
Permit Date: 12 February, 2019 ��lrSS!®� 0 J d'
Permit Number: V
Construction Site: Owner/Agent: Designer/Contractor: G N
36 Wooden Lane Michaels Group Homes, LLC I 0 7,
Queensbury, NY 12804 1 Marions Way t9 �t�` ® ♦D.H.
fn
Mechanicville, NY 12118 REVIEWED FOR pp
ENERGY CODE COMPLlA.l��lC r_ ° J
• s mpliance:Passes using t1A trade-off N N 0.
LJ—
Compliance: 5.2%Better Than Code Maximum UA: 271 Your UA: 257 r 0) 0
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. CO03 0It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Z > o
Envelope Assemblies
0122cow
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling: Raised or Energy Truss 1,658 38.0 0.0 0.025 41
Walls: Wood Frame, 24" o .c. 1,674 21.0 0.0 0.056 78
Entry#la: Solid 29 0.170 5
2x Bed #2 (AV): Vinyl Frame:Double Pane with Low-E 33 0.300 10
lx Bath (AA): Vinyl Frame:Double Pane with Low-E 5 0.300 2
lx Home Office(H): Vinyl Frame:Double Pane with Low-E 33 0.300 10
2x Dining (B): Vinyl Frame:Double Pane with Low-E 20 0.300 6
Dining #7: Glass 40 0.330 13
2x Great Room (E): Vinyl Frame:Double Pane with Low-E 29 0.300 9
lx Great Room (R): Vinyl Frame:Double Pane with Low-E 27 0.300 8
lx Master Bed (H): Vinyl Frame:Double Pane with Low-E 33 0.300 10
lx Master Bath (AM): Vinyl Frame:Double Pane with Low-E 7 0.300 2
Mud#20: Solid 19 0.170 3
Basement Walls: Solid Concrete or Masonry 1,413 0.0 19.0 0.039 54
Wall height: 7.6'
Depth below grade: 6.6'
Insulation depth: 7.6'
2x Std Basement Windows: Wood Frame:Double Pane with Low-E 4 0.300 1
Project Title: The Hawthorn Report date: 02/12/19
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 1 of10
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
lx 5030 Sliding Window:Wood Frame:Double Pane with Low-E 15 0.300 5
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Keith D. Rupert,P.E. Feb. 13,2019
Name-Title Signature Date
Project Title: The Hawthorn Report date: 02/12/19
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 2 of10
REScheck Software Version 4.6.5
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.lD
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR111 energy code compliance for the
building envelope.Thermal ['Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ❑Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods ❑Not Observable
Btu/hr Btu/hr ❑Not Applicable
approved by the code official. pp'cable
Additional Comments/Assumptions:
1 High Impact(Tier 1) T2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 02/12/19
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 3 of10
Section i Plans Verified a Field Verified i
# I Foundation Inspection Complies? i Comments/Assumptions
Valu
&Req.1D e i Value ! I
402.1.1 Conditioned basement wall R- R- ElComplies See the Envelope Assemblies
[FO4]1 insulation R-value.Where interior R_ R- ❑Does Not table for values.
insulation is used,verification ['Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[F05]1 insulation installed per ElDoes Not
manufacturer's instructions. ❑Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[F06]1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall. Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ['Not Observable
L_. :Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[F012]2 controls installed. ❑Does Not
❑Not Observable
ElNot Applicable
Additional Comments/Assumptions:
1 ,High Impact(Tier 1) 2 I Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 02/12/19
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 4 of10
! Section li
: Plans Verified Field Verified
I
& Re ID IFraming/Rough-In Inspection; Value I Value Complies? I Comments/Assumptions
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
3
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.5 ❑Not Observable
[FR2]1 ❑Not Applicable
41)
303.1.3 U-factors of fenestration products— ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. ❑Not Observable
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
:Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20I1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
'402.4.5 IC-rated recessed lighting fixtures ❑Complies
l[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate . 2.0 cfm
leakage at 75 Pa. ❑Not Observable
❑Not Applicable
403.3.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
R-6 where <3 inches.Supply and ['Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3,5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
:Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies
,[FR17]2 above 105°F or chilled fluids ❑Does Not
below 55 °F are insulated to>_R-
3 ❑Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVACR24j1 piping.
❑Complies
[F ❑Does Not
' ❑Not Observable
_ ❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
1[FR18]2 >_R-3. EDoes Not
! [Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are EComplies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
['Not Observable
ENot Applicable
1 1 High Impact(Tier 1) 2 ;Medium Impact(Tier 2) 13 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 02/12/19
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 5 of10
Section Plans Verified i Field Verified
Insulation Inspection Value Value Complies? ' Comments/Assumptions
& Req.lD'i_ _ j
1303.1 All installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided. ❑Not Observable
❑Not Applicable
1402.1.1, Wall insulation R-value. If this is a R- R- Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall
[IN3]i exterior, the exterior insulation ❑ Mass ❑ Mass ['Not Observable
Steel
i requirement applies (FR10). ❑ ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
I[IN4]1 manufacturer's instructions. ❑Does Not
['Not Observable
I ❑Not Applicable
Additional Comments/Assumptions:
11 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 02/12/19
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 7 of10
•
Section • Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Re .I0` ' I 1
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood DDoes Not table for values.
402.2.2, ❑ Steel ❑ Steel ENot Observable
402.2.E[FI1]1 CI Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[Fl2]1 Blown insulation marked every
300 ft2. ❑Not Observable
ENot Applicable
402,2.3 Vented attics with air permeable EComplies
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ENot Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[F131' insulation >_R-value of the ❑Does Not
adjacent assembly.
:Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
[Not Observable
❑Not Applicable
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ['Not Observable
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F127]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a ['Not Observable
pressure differential of 0.1 inch ENot Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
ENot Applicable
403.1.1 Programmable thermostats ❑Complies
[Fl9]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ['Not Observable
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI10]2 on heat pumps. ❑Does Not
ENot Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies
(FI11]2 systems have automatic or ❑Does Not
accessible manual controls.
ENot Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) i 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 02/12/19
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 8 of10
Section Plans Verified Field Verified•
# I Final Inspection Provisions ,, Complies? Comments/Assumptions
& Req.li? I Value Value
403.6.1 All mechanical ventilation system EComplies
[F125]2 fans not part of tested and listed EDoes Not
HVAC equipment meet efficacy ['Not Observable
and air flow limits.
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[FI26j2 through one-or two-pipe heating EDoes Not
systems have outdoor setback
control to lower boiler water ['Not Observable
temperature based on outdoor CI Not Applicable
temperature.
403.5.1.1 Heated water circulation systems EComplies
[FI28]2 have a circulation pump.The EDoes Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
4035.1.2 Electric heat trace systems EComplies
[F129]2 comply with IEEE 515.1 or UL EDoes Not
515. Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that EComplies
[FI30]2 have recirculation pumps that CI Does Not
pump water from a heated water
supply pipe back to the heated ['Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F.
403.5.4 Drain water heat recovery units EComplies
[F131J2 tested in accordance with CSA EDoes Not
j B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units< 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[FI6]1 fixtures or 75%of permanent EDoes Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have EComplies
[FI23]3 no continuous pilot light. EDoes Not
A4 ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 ;Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 02/12/19
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 9 of10
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.IL1, i
401.3 Compliance certificate posted. ❑Complies
I[F17]2 ❑Does Not
['Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
ENot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) I 2 !Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 02/12/19
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 10 of10
i20'15 IE
C EfficiencyCC Energy Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 19.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.30
Door 0.33
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments