Loading...
ResCheck REScheck Software Version 4.6.5 r Compliance Certificate i .µ ; FEB 2 p 2019 , FILE COPY comma, `�� .. Project The Hawthorn OF NEW 'ITY �_,,, i U„0° 4% o RirAt u YQ ;; op Energy Code: 2015 IECC COy°, .v. �� ��15+,, * • ���` Location: Glens Falls, New York , * 1 Construction Type: Single-family r- " ` cr 05 Project Type: New Construction t7 `cit y - is Conditioned Floor Area: 1,658 ft2 +!s ..�r-� w O 9—; Glazing Area 15% �� �/ �• N N 6 (7635 HDD) I Ogg. „ CO V Climate Zone: cci L� Permit Date: 12 February, 2019 ��lrSS!®� 0 J d' Permit Number: V Construction Site: Owner/Agent: Designer/Contractor: G N 36 Wooden Lane Michaels Group Homes, LLC I 0 7, Queensbury, NY 12804 1 Marions Way t9 �t�` ® ♦D.H. fn Mechanicville, NY 12118 REVIEWED FOR pp ENERGY CODE COMPLlA.l��lC r_ ° J • s mpliance:Passes using t1A trade-off N N 0. LJ— Compliance: 5.2%Better Than Code Maximum UA: 271 Your UA: 257 r 0) 0 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. CO03 0It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Z > o Envelope Assemblies 0122cow Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling: Raised or Energy Truss 1,658 38.0 0.0 0.025 41 Walls: Wood Frame, 24" o .c. 1,674 21.0 0.0 0.056 78 Entry#la: Solid 29 0.170 5 2x Bed #2 (AV): Vinyl Frame:Double Pane with Low-E 33 0.300 10 lx Bath (AA): Vinyl Frame:Double Pane with Low-E 5 0.300 2 lx Home Office(H): Vinyl Frame:Double Pane with Low-E 33 0.300 10 2x Dining (B): Vinyl Frame:Double Pane with Low-E 20 0.300 6 Dining #7: Glass 40 0.330 13 2x Great Room (E): Vinyl Frame:Double Pane with Low-E 29 0.300 9 lx Great Room (R): Vinyl Frame:Double Pane with Low-E 27 0.300 8 lx Master Bed (H): Vinyl Frame:Double Pane with Low-E 33 0.300 10 lx Master Bath (AM): Vinyl Frame:Double Pane with Low-E 7 0.300 2 Mud#20: Solid 19 0.170 3 Basement Walls: Solid Concrete or Masonry 1,413 0.0 19.0 0.039 54 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' 2x Std Basement Windows: Wood Frame:Double Pane with Low-E 4 0.300 1 Project Title: The Hawthorn Report date: 02/12/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 1 of10 Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter lx 5030 Sliding Window:Wood Frame:Double Pane with Low-E 15 0.300 5 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Keith D. Rupert,P.E. Feb. 13,2019 Name-Title Signature Date Project Title: The Hawthorn Report date: 02/12/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 2 of10 REScheck Software Version 4.6.5 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.lD 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the building envelope.Thermal ['Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ❑Not Observable Btu/hr Btu/hr ❑Not Applicable approved by the code official. pp'cable Additional Comments/Assumptions: 1 High Impact(Tier 1) T2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 02/12/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 3 of10 Section i Plans Verified a Field Verified i # I Foundation Inspection Complies? i Comments/Assumptions Valu &Req.1D e i Value ! I 402.1.1 Conditioned basement wall R- R- ElComplies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used,verification ['Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]1 insulation installed per ElDoes Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ['Not Observable L_. :Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012]2 controls installed. ❑Does Not ❑Not Observable ElNot Applicable Additional Comments/Assumptions: 1 ,High Impact(Tier 1) 2 I Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 02/12/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 4 of10 ! Section li : Plans Verified Field Verified I & Re ID IFraming/Rough-In Inspection; Value I Value Complies? I Comments/Assumptions 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable 3 ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ❑Not Observable [FR2]1 ❑Not Applicable 41) 303.1.3 U-factors of fenestration products— ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. :Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20I1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. '402.4.5 IC-rated recessed lighting fixtures ❑Complies l[FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate . 2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where <3 inches.Supply and ['Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3,5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not :Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies ,[FR17]2 above 105°F or chilled fluids ❑Does Not below 55 °F are insulated to>_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVACR24j1 piping. ❑Complies [F ❑Does Not ' ❑Not Observable _ ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies 1[FR18]2 >_R-3. EDoes Not ! [Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are EComplies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ['Not Observable ENot Applicable 1 1 High Impact(Tier 1) 2 ;Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 02/12/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 5 of10 Section Plans Verified i Field Verified Insulation Inspection Value Value Complies? ' Comments/Assumptions & Req.lD'i_ _ j 1303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 1402.1.1, Wall insulation R-value. If this is a R- R- Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN3]i exterior, the exterior insulation ❑ Mass ❑ Mass ['Not Observable Steel i requirement applies (FR10). ❑ ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies I[IN4]1 manufacturer's instructions. ❑Does Not ['Not Observable I ❑Not Applicable Additional Comments/Assumptions: 11 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1Low Impact(Tier 3) Project Title: The Hawthorn Report date: 02/12/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 7 of10 • Section • Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .I0` ' I 1 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood DDoes Not table for values. 402.2.2, ❑ Steel ❑ Steel ENot Observable 402.2.E[FI1]1 CI Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [Fl2]1 Blown insulation marked every 300 ft2. ❑Not Observable ENot Applicable 402,2.3 Vented attics with air permeable EComplies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ENot Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F131' insulation >_R-value of the ❑Does Not adjacent assembly. :Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. [Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ['Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ['Not Observable pressure differential of 0.1 inch ENot Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ENot Applicable 403.1.1 Programmable thermostats ❑Complies [Fl9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ['Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ENot Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies (FI11]2 systems have automatic or ❑Does Not accessible manual controls. ENot Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) i 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 02/12/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 8 of10 Section Plans Verified Field Verified• # I Final Inspection Provisions ,, Complies? Comments/Assumptions & Req.li? I Value Value 403.6.1 All mechanical ventilation system EComplies [F125]2 fans not part of tested and listed EDoes Not HVAC equipment meet efficacy ['Not Observable and air flow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26j2 through one-or two-pipe heating EDoes Not systems have outdoor setback control to lower boiler water ['Not Observable temperature based on outdoor CI Not Applicable temperature. 403.5.1.1 Heated water circulation systems EComplies [FI28]2 have a circulation pump.The EDoes Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 4035.1.2 Electric heat trace systems EComplies [F129]2 comply with IEEE 515.1 or UL EDoes Not 515. Controls automatically adjust the energy input to the ['Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that EComplies [FI30]2 have recirculation pumps that CI Does Not pump water from a heated water supply pipe back to the heated ['Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units EComplies [F131J2 tested in accordance with CSA EDoes Not j B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI6]1 fixtures or 75%of permanent EDoes Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have EComplies [FI23]3 no continuous pilot light. EDoes Not A4 ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 ;Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 02/12/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 9 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.IL1, i 401.3 Compliance certificate posted. ❑Complies I[F17]2 ❑Does Not ['Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) I 2 !Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 02/12/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\36 Wooden Lane.rck Page 10 of10 i20'15 IE C EfficiencyCC Energy Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.33 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments