ComCheck • COMcheck Software Version 4.0.8.1 , r N o � o � Ati Envelope Compliance Certificate 3 N D . ECCE11WER -, c, -2, Project Information y Energy Code: 2015 IECC L MAR 1s2019 1 g a CD Project Title: Location: Glens Falls, New YotiTOWN OF QUEENSBURY 0 Climate Zone: 6a BUILDING&COMES Project Type: Addition C) O Construction Site: Owner/Agent: Designer/Contractor: -P CA) N O14 0 Building Area Floor Area 'N-P. co 1-STORAGE(Dining: Bar Lounge/Leisure): Nonresidential 1iEVIEWCD FOR Envelope Assemblies ENERGY CODE COMPLIANCE Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factorat Perimeter Roof 1:Attic Roof with Wood Joists,[Bldg. Use 1 -STORAGE] 176 38.0 0.0 0.027 0.021 Floor 1:Wood-Framed,[Bldg.Use 1 -STORAGE] 176 30.0 0.0 0.033 0.033 EAST Exterior Wall 2:Wood-Framed, 16"o.c.,[Bldg.Use 1 -STORAGE] 88 21.0 6.0 0.043 0.051 SOUTH Exterior Wall 1:Wood-Framed, 16"o.c.,[Bldg. Use 1 -STORAGE] 128 21.0 6.0 0.043 0.051 WEST Exterior Wall 3:Wood-Framed, 16"o.c.,[Bldg. Use 1 -STORAGE] 88 21.0 6.0 0.043 0.051 (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Envelope PASSES: Design 0.0% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist.REVIEWED BY 7 10; 3 /y I g Name-Title G. PETER JENSEN ig•' ;de Dt / 17 WEST ROAD ` SOUTH GLENS FALLS !GcAED AqC NEW YORK 12803 �,�t (ER�F�, tii (518) 798-3859 4, Q crA <�' spy P * FILE C� Y �,q 0,2�id Co. Project Title: Report date: 03/10/19 Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 1 of 9 COMcheck Software Version 4.0.8.1 rift A(1 Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Project Type: Addition Construction Site: Owner/Agent: Designer/Contractor: Allowed Interior Lighting Power Proposed Interior Lighting Power Interior Lighting TBD: Invalid building use type Project Title: Report date: 03/10/19 Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 2 of 9 i • COMcheck Software Version 4.0.8.1 li il Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. C103.2 Plans and/or specifications provide all ❑Complies [PR1]1 information with which compliance ❑Does Not can be determined for the building ❑Not Observable envelope and document where exceptions to the standard are ❑Not Applicable claimed. C402.4.1 :The vertical fenestration area <=30 DComplies [PR10]1 ;percent of the gross above-grade wall ❑Does Not :area. DNot Observable Ii:Not Applicable C402.4.1 IThe skylight area <= 3 percent of the DComplies [PR11]1 !,gross roof area. ❑Does Not ❑Not Observable ❑Not Applicable C406 Plans,specifications,and/or DComplies [PR9]1 calculations provide all information ODoes Not with which compliance can be ['Not Observable determined for the additional energy efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3) Project Title: Report date: 03/10/19 Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 3 of 9 C303.2.1 :Exterior insulation protected against ❑Complies [FO611 ;damage, sunlight, moisture, wind, ❑Does Not :landscaping and equipment :maintenance activities. Not Observable • `❑Not Applicable Radiant heating systems panels ❑Complies See the Envelope Assemblies table for values. insulated to >=R-3.5 on face opposite ❑Does Not space being heated. :Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3) Project Title: Report date: 03/10/19 Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 4 of 9 C402.5.1 :The building envelope contains a ❑Complies [FR16]1 ;continuous air barrier that is sealed in ❑Does Not :an approved manner and either ['Not Observable :constructed or tested in an approved :manner.Air barrier penetrations are ❑Not Applicable ;sealed in an approved manner. Additional Comments/Assumptions: 1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3) Project Title: Report date: 03/10/19 Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 5 of 9 Stair and elevator shaft vents have ❑Complies motorized dampers that automatically ❑Does Not close. []Not Observable ❑Not Applicable i Outdoor air and exhaust systems have ❑Complies motorized dampers that automatically ❑Does Not shut when not in use and meet ❑Not Observable maximum leakage rates.Check gravity dampers where allowed. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3) 1 Project Title: Report date: 03/10/19 Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 6 of 9 • C303.1 ;Roof insulation installed per ❑Complies [IN3]1 ;manufacturer's instructions. Blown or ODoes Not ;poured loose-fill insulation is installed ['Not Observable :only where the roof slope is<=3 in 12 ONot Applicable Building envelope insulation is labeled OComplies with R-value or insulation certificate ODoes Not providing R-value and other relevant data. ONot Observable i❑Not Applicable C303.2 Above-grade wall insulation installed ❑Complies [IN7]1 ;per manufacturer's instructions. ODoes Not ONot Observable ONot Applicable Floor insulation installed per ❑Complies manufacturer's instructions. Cavity or ODoes Not structural slab insulation installed in ONot Observable permanent contact with underside of decking or structural slabs. ❑Not Applicable Exterior insulation is protected from DComplies damage with a protective material. ODoes Not Verification for exposed foundation ONot Observable insulation may need to occur during Foundation Inspection. ONot Applicable Insulation intended to meet the roof DComplies insulation requirements cannot be ODoes Not installed on top of a suspended :Not Observable ceiling. Mark this requirement compliant if insulation is installed ONot Applicable accordingly. C402.2.3 :Above-grade wall insulation R-value. DComplies See the Envelope Assemblies table for values. [IN6]1 ODoes Not ONot Observable ONot Applicable i E Floor insulation R-value. DComplies See the Envelope Assemblies table for values. ODoes Not ONot Observable iONot Applicable Radiant panels and associated DComplies components, designed for heat ODoes Not transfer from the panel surfaces to the occupants or indoor space are ONot Observable insulated with a minimum of R-3.5. ONot Applicable C402.2.2 Roof R-value. For some ceiling DComplies See the Envelope Assemblies table for values. [IN2)1 systems, verification may need to ODoes Not occur during Framing Inspection. ONot Observable ❑Not Applicable C402.5.1. All sources of air leakage in the DComplies 1 building thermal envelope are sealed, ODoes Not [IN1]1 caulked, gasketed, weather stripped :Not Observable or wrapped with moisture vapor- permeable wrapping material to ONot Applicable minimize air leakage. Additional Comments/Assumptions: 1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3) Project Title: Report date: 03/10/19 Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 7 of 9 Where open combustion air ducts OComplies provide combustion air to open ❑Does Not combustion fuel burning appliances, ❑Not Observable the appliances and combustion air opening are located outside the ❑Not Applicable building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms are sealed and insulated. i Recessed luminaires in thermal ❑Complies envelope to limit infiltration and be IC ❑Does Not rated and labeled. Seal between ❑Not Observable interior finish and luminaire housing. ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3) Project Title: Report date: 03/10/19 Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 8 of 9