ComCheck •
COMcheck Software Version 4.0.8.1 , r N
o � o �
Ati Envelope Compliance Certificate 3 N
D
. ECCE11WER -, c, -2,
Project Information y
Energy Code: 2015 IECC L MAR 1s2019 1 g a CD
Project Title:
Location: Glens Falls, New YotiTOWN OF QUEENSBURY 0
Climate Zone: 6a BUILDING&COMES
Project Type: Addition C)
O
Construction Site: Owner/Agent: Designer/Contractor: -P CA)
N
O14
0
Building Area Floor Area 'N-P.
co
1-STORAGE(Dining: Bar Lounge/Leisure): Nonresidential 1iEVIEWCD FOR
Envelope Assemblies ENERGY CODE COMPLIANCE
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factorat
Perimeter
Roof 1:Attic Roof with Wood Joists,[Bldg. Use 1 -STORAGE] 176 38.0 0.0 0.027 0.021
Floor 1:Wood-Framed,[Bldg.Use 1 -STORAGE] 176 30.0 0.0 0.033 0.033
EAST
Exterior Wall 2:Wood-Framed, 16"o.c.,[Bldg.Use 1 -STORAGE] 88 21.0 6.0 0.043 0.051
SOUTH
Exterior Wall 1:Wood-Framed, 16"o.c.,[Bldg. Use 1 -STORAGE] 128 21.0 6.0 0.043 0.051
WEST
Exterior Wall 3:Wood-Framed, 16"o.c.,[Bldg. Use 1 -STORAGE] 88 21.0 6.0 0.043 0.051
(a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements.
Envelope PASSES: Design 0.0% better than code
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed envelope systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.REVIEWED BY 7 10; 3 /y I g
Name-Title G. PETER JENSEN ig•' ;de Dt /
17 WEST ROAD `
SOUTH GLENS FALLS !GcAED AqC
NEW YORK 12803 �,�t (ER�F�, tii
(518) 798-3859 4,
Q crA <�' spy P
* FILE C� Y
�,q 0,2�id Co.
Project Title: Report date: 03/10/19
Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 1 of 9
COMcheck Software Version 4.0.8.1
rift A(1 Interior Lighting Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title:
Project Type: Addition
Construction Site: Owner/Agent: Designer/Contractor:
Allowed Interior Lighting Power
Proposed Interior Lighting Power
Interior Lighting TBD: Invalid building use type
Project Title: Report date: 03/10/19
Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 2 of 9
i
•
COMcheck Software Version 4.0.8.1
li il Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
C103.2 Plans and/or specifications provide all ❑Complies
[PR1]1 information with which compliance ❑Does Not
can be determined for the building ❑Not Observable
envelope and document where
exceptions to the standard are ❑Not Applicable
claimed.
C402.4.1 :The vertical fenestration area <=30 DComplies
[PR10]1 ;percent of the gross above-grade wall ❑Does Not
:area. DNot Observable
Ii:Not Applicable
C402.4.1 IThe skylight area <= 3 percent of the DComplies
[PR11]1 !,gross roof area. ❑Does Not
❑Not Observable
❑Not Applicable
C406 Plans,specifications,and/or DComplies
[PR9]1 calculations provide all information ODoes Not
with which compliance can be ['Not Observable
determined for the additional energy
efficiency package options. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3)
Project Title: Report date: 03/10/19
Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 3 of 9
C303.2.1 :Exterior insulation protected against ❑Complies
[FO611 ;damage, sunlight, moisture, wind, ❑Does Not
:landscaping and equipment
:maintenance activities. Not Observable
•
`❑Not Applicable
Radiant heating systems panels ❑Complies See the Envelope Assemblies table for values.
insulated to >=R-3.5 on face opposite ❑Does Not
space being heated. :Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3)
Project Title: Report date: 03/10/19
Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 4 of 9
C402.5.1 :The building envelope contains a ❑Complies
[FR16]1 ;continuous air barrier that is sealed in ❑Does Not
:an approved manner and either ['Not Observable
:constructed or tested in an approved
:manner.Air barrier penetrations are ❑Not Applicable
;sealed in an approved manner.
Additional Comments/Assumptions:
1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3)
Project Title: Report date: 03/10/19
Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 5 of 9
Stair and elevator shaft vents have ❑Complies
motorized dampers that automatically ❑Does Not
close. []Not Observable
❑Not Applicable
i
Outdoor air and exhaust systems have ❑Complies
motorized dampers that automatically ❑Does Not
shut when not in use and meet ❑Not Observable
maximum leakage rates.Check
gravity dampers where allowed. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3)
1
Project Title: Report date: 03/10/19
Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 6 of 9
•
C303.1 ;Roof insulation installed per ❑Complies
[IN3]1 ;manufacturer's instructions. Blown or ODoes Not
;poured loose-fill insulation is installed ['Not Observable
:only where the roof slope is<=3 in
12 ONot Applicable
Building envelope insulation is labeled OComplies
with R-value or insulation certificate ODoes Not
providing R-value and other relevant
data. ONot Observable
i❑Not Applicable
C303.2 Above-grade wall insulation installed ❑Complies
[IN7]1 ;per manufacturer's instructions. ODoes Not
ONot Observable
ONot Applicable
Floor insulation installed per ❑Complies
manufacturer's instructions. Cavity or ODoes Not
structural slab insulation installed in ONot Observable
permanent contact with underside of
decking or structural slabs. ❑Not Applicable
Exterior insulation is protected from DComplies
damage with a protective material. ODoes Not
Verification for exposed foundation ONot Observable
insulation may need to occur during
Foundation Inspection. ONot Applicable
Insulation intended to meet the roof DComplies
insulation requirements cannot be ODoes Not
installed on top of a suspended :Not Observable
ceiling. Mark this requirement
compliant if insulation is installed ONot Applicable
accordingly.
C402.2.3 :Above-grade wall insulation R-value. DComplies See the Envelope Assemblies table for values.
[IN6]1 ODoes Not
ONot Observable
ONot Applicable
i E
Floor insulation R-value. DComplies See the Envelope Assemblies table for values.
ODoes Not
ONot Observable
iONot Applicable
Radiant panels and associated DComplies
components, designed for heat ODoes Not
transfer from the panel surfaces to the
occupants or indoor space are ONot Observable
insulated with a minimum of R-3.5. ONot Applicable
C402.2.2 Roof R-value. For some ceiling DComplies See the Envelope Assemblies table for values.
[IN2)1 systems, verification may need to ODoes Not
occur during Framing Inspection.
ONot Observable
❑Not Applicable
C402.5.1. All sources of air leakage in the DComplies
1 building thermal envelope are sealed, ODoes Not
[IN1]1 caulked, gasketed, weather stripped :Not Observable
or wrapped with moisture vapor-
permeable wrapping material to ONot Applicable
minimize air leakage.
Additional Comments/Assumptions:
1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3)
Project Title: Report date: 03/10/19
Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 7 of 9
Where open combustion air ducts OComplies
provide combustion air to open ❑Does Not
combustion fuel burning appliances, ❑Not Observable
the appliances and combustion air
opening are located outside the ❑Not Applicable
building thermal envelope or enclosed
in a room, isolated from inside the
thermal envelope. Such rooms are
sealed and insulated. i
Recessed luminaires in thermal ❑Complies
envelope to limit infiltration and be IC ❑Does Not
rated and labeled. Seal between ❑Not Observable
interior finish and luminaire housing.
ONot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) -Medium Impact(Tier 2) -Low Impact(Tier 3)
Project Title: Report date: 03/10/19
Data filename: C:\Users\kevin\Documents\COMcheck\log jam.cck Page 8 of 9