Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Manual S
ovwzDND4 , Manual S Compliance Report [ C Entire House Adirondack P&M MAR 19 2019 . Lill PO Box 562,Glens Falls,NY 12801 Phone:518-793-3883 Email:irio@adirorxlackpm.com 2 TOWN OF it osizi f rm• LuILulJVhr. •. Project Information For: The Springs,Monsour Queensbury,NY 12804 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 12882 Btuh Entering coil DB: 75.0°F Outdoor design WB: 70.8°F Latent gain: 6171 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 19053 Btuh Indoor RH: 50% Estimated airflow: 687 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitAC Manufacturer: Amana Model: ASX130241C*+C(R,S)30B24+A"VC960804CNA`+TDR Actual airflow: 687 cfm Sensible capacity: 14420 Btuh 112%of load Latent capacity: 6180 Btuh 100%of load Total capacity: 20600 Btuh 108%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: -3.5°F Heat loss: 35086 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: Amana Model: AMSS960402BN Actual airflow: 687 cfm Output capacity: 38000 Btuh 108%of load Temp.rise: 50 °F Meets all requirements ofACCA Manual S. WrightsOft" 2019-Feb-08 12:34:43 `'" w. Rigtt-Stite®Universal 2018 18.0.16 RSU21843 Page 1 _ate7151Doarnerts\Wrigfisolt HVAUfbaSpringsrup Calc=MJB Front Door faces: N J1 Form -Worksheet A Job: The Springs OND r&At,„ �- Date: Feb 08,2019 Entire House By: Adirondack P&M PO Box 562,Glens Falls,NY 12801 Phone:518-793-3883 Email:irto@adirondackpm.com Supporting Detail Project Name: TheSprings Date: Feb 08,2019 Address: Queensbury,NY 12804 Phone: Job ID: The Springs Worksheet A Location and Design Conditions Weather Location: Glens FallsAP,NY,US Elevation= 335 Latitude= 43 Indoor Conditions,Heating: DB= 68°F RH= 50 % Indoor Conditions,Cooling: DB= 75°F RH= 50 % Table 1 Conditions 99%DB= -4 °F 1%DB= 85 °F Grains Difference= 27 gr/Ib Daily Range= M Design Temperature Differences HTD= 72 °F CTD= 10 °F Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-08 12:34:43 wrightsoft` Right-Sute®Universal 2018 18.0.16 RSU21843 Page 1 ACC , ...ate7151Doamerts\Wrigttsoft HVACRheSprirgs.mp Cale=MJ8 Frond Door faces: N HVAC Design Report ENERGY STAR Certified Homes, Version 3 / 3.1 (Rev. 08) Designer 4.Heating&Cooling Equipment Selection Verified 4.1 Equipment selected perACCA Manual S(see Footnote 19&20) CI Air Conditioner/Heat Pump (Complete if air conditioner or heat pump will be installed;otherwise check"NIA') M N/A 4.2 Equipment type: •Cooling-only air conditioner or O Cooling&heating heat pump - 4.3 Condenser manufacturer&model: Amana ASX130241 C* - 4.4 Evaporator/fan coil manufacturer&model: Amana C(R,S)30B24+A*VC960804CNA"+TDR - 4.5AHRI reference#: 7458837 - 4.6 AHRI listed efficiency: 10 / 13.5 EER/SEER Air-source heat pump: HSPF Ground-source heat pump: COP - 4.7 Evaporator fan type: ED PSC El ECM/ICM •Other: - 4.8 Compressor type: I•Single-speed I=Two-speed El Variable-speed - 4.9 Latent capacity at design conditions,from OEM expanded performance data: 0 kBtuh - 4.10 Sensible capacity at design conditions,from OEM expanded performance data: 0 kBtuh - 4.11 Total capacity at design conditions,from OEM expanded performance data: 0 kBtuh - 4.12 Air-source heat pump capacity: At 17°F: 0 kBtuh At 47°F: 0 kBtuh •N/A - 4.13 Cooling sizing%=Total capacity(Item 4.11)divided by maximum total heat gain(Item 3.12): 0% - 4.14 Complete this Item if Condition B Climate will be used to select sizing limit in Item 4.15.Otherwise,check"N/A": •N/A - 4.14.1 Load sensible heat ratio=Max.sensible heat gain(Item 3.10)/Max.total heat gain(Item 3.12) = 70% - 4.14.2 HDD/CDD ratio(Visit energystar.gov/hvaodesigntemps to determine this value for the design location) = 3.3 - 4.15 Check box of applicable cooling sizing limit from chart below - Equipment Type(Per Item 4.2)& Compressor Type(Per Item 4.8) Climate Condition(Per Item 4.14) Single-Speed Two-Speed Variable-Speed For Cooling-Only Equipment or Recommended:90-115% Recommended:90-120% Recommended:90-130% For Cooling Mode of Heat Pump in 0 Allowed:90-130% tl Allowed:90-140% El Allowed:90-160% Condition A Climate For Cooling Mode of Heat Pump in I= 90%-100%,plus 15 kBtuh = 90%-100%,plus 15 kBtuh 0 90%-100%,plus 15 kBtuh Condition B Climate 4.16 Cooling sizing%(4.13)is within cooling sizing limit(4.15) El Furnace (Complete if furnace will be installed;otherwise check"N/A") tl N/A 4.17 Furnace manufacturer&model: Amana AMSS960402BN - 4.18 Listed efficiency: 96.1 AFUE - 4.19 Total capacity: 38 kBtuh - 4.20 Heating sizing%=Total capacity(Item 4.19)divided by total heat loss(Item 3.14): 108% - 4.21 Check box of applicable heating sizing limit from chart below. - When Used for Heating Only When Paired With Cooling p 100-140% IN Recommended: 100-140%Allowed: 100-200% 4.22 Heating sizing%(4.20)is within heating sizing limit(4.21) MI 5.Duct Design (Complete if heating or cooling equipment will be installed with ducts;otherwise check"N/A") = N/A 5.1 Duct system designed for the equipment selected in Section 4,perACCA Manual D 1111 5.2 Design HVAC fan airflow Cooling mode 687 CFM Heating mode 687 CFM - 5.3 Design HVAC fan speed setting(e.g.,low,medium,high): Cooling mode Medium Heating mode Medium - 5.4 Design total external static pressure(corresponding to the mode with the higher airflow in Item 5.2): 0 IWC - 5.5 Room-by-room design airflows documented below(which must sum to the mode with the higher airflow in Item 5.2) - Room Name Design Airflow(CFM) Room Name Design Airflow(CFM) 1 Room10 49 13 Room5 28 2 Room11 25 14 Room6 47 3 Room12 40 15 Room7 100 4 Room13 38 16 Room9 48 5 Room14 38 17 6 Room15 0 18 7 Room16 53 19 8 Room17 24 20 9 Room18 80 21 10 Room2 40 22 11 Room3 50 23 12 Room4 27 Total for all rooms 687 - - wrightscfta' 2019-Feb0812'.3443 M•,.. ..^,.._- ' Rigtt-Sute®Universal 201818.0-16RSU21843 Page2 _.ate715\Docunerts\Wrigttsoft HVAC VTteSprirgs.r p Caic=MJ8 Frord Door faces: N Specification Sheet item .'t8-�;1-f 1 4"1-Li1 ne� FLEI( 100H® .®•l SR jMvs c us lc.ERTIPEA.) Heat Recovery Ventilator Product #: 44001 Fans Two(23 factory-balanced fans with backward curved blades.Motors come with permanently lubricated, sealed ball-bearings to guarantee long life and maintenance-free operation. �rf Heat Recovery Core Pr Aluminum heat recovery core covered by a limited lifetime warranty.Core dimensions are 8.5"x 8.5"t216 x 216 mm)with a 12" (305 mm)depth. n Our heat exchangers are designed and manufactured to withstand y F.n k'�P;1;7t±tF 1 � extreme temperature variations. WinterguardtM Defrost ' ; • The FLEX 100H incorporates a unique and quiet internal recirculation defrost that does not depressurize the home during the defrost cycle.A preset defrost sequence is activated when the outdoor temperature falls below 23°F(-5°C)and automatically adjusts itself based on operating As Fantech's masterpiece of versatility, features and efficiency,the Flex conditions.The fan speed is also adjusted automatically to provide a 100H is ideal for high-rise apartment applications, condominiums, single smooth and quiet transition between Ventilation&Defrost mode. and multi family homes. With its compact top port design featuring 5 Serviceability inch oval collars and the included EZ-MountTM wall bracket, the Flex Core, filters,fans and electronic panel can be accesses easily from the 100H can be installed in spaces as small as 24 inches, such as a closet access panel. Core conveniently slides out with only 14"256 mm) or maintenance room. clearance. Unlike traditional HRVs that require excessive power to meet Duct Connections supplemental ventilation needs,the compact, yet powerful Flex 100H 5"(125mm)Oval plastic duct connections with integrated balancing allows for sizing based entirely on principal ventilation requirements. damper and airflow measurement ports. With its exclusive TurboTouchIm feature, the Flex 100H can deliver up to 50%more exhaust capacity to easily meet supplemental ventilation Case needs whenever additional airflow is required. 24 gauge galvanized steel. Baked power-coated paint for a superior adhesion and resistance. Features • TurboTouch function boosts exhaust capacity by up to 50% Insulation • 5" (125mm) oval duct connections with integrated airflow Cabinet is fully insulated with 1"(25 mm)high density expanded measurement polystyrene. • Removable screw terminal for easy connection Filters • Lightweight: only 39 lbs (17.7 kg) including core Two(2)washable electrostatic panel type air filters 8.5"(216mm) x • Super compact size 12.5"(318 mm)x 0.125"(3mm). • Top port design fits in tight spaces • Includes EZ-Mount wall bracket Drain • Aluminum heat recovery core 1/2"(13mm)OD (outside diameter)drain spout provided,entire bottom • Multiple speed operation of unit covered by drain pan. • Internal recirculation defrost Warranty Optional Controls: • ECO-TOUCH�(a44s2si — Programmable Touch Screen Wall Control limited lifetime on aluminum core,7 year on motors,and 5 year on parts. • EDF7 (wen — Electronic multi-function dehumidistat • RTS2 (#4oisa} — 20 minute timer over-ride • RTS5 (a447 4) — 20/40/60 minute timer • MDEH1 (a4o172( — Dehumidistat Specifications • Duct size — 5"(125mm)oval • Voltage/Phase — 120/1 • Power rated — 168 W • Amp — 1-4 A • Average airflow — 105 cfm(50 Us) 0.4"PS(100Pa) 09 fantech •.• a systemair company Dimensions&Airflow E F . MOM 1 r- 1 t , # ,,,,, It h. — an c - — 1-m�a .P.momm0NNT4h tzs> fresh air to inside Dc11 /1111 fresh air from outside — _ i 1 III IN!I aul stale air � from inside 0110,�•�1!�i stale air A �_ B _____„„4 — -- to outside Model A B C 0 E I 11 rf411 in mm I 11111 111 WI in rem in him Flex 100H 21 1/2 546 141/2 368 15 5/8 397 17 7/8 454 221/2 572 15 381 Dimensional information is in inches.Clearance of 14")356ntml in front of the unit is recommended for removal of core.All units feature three foot plug-in power cord with 3-prong plug. Ventilation Performance Airflow(Us) 0 12 24 35 47 59 71 82 94 in.wg.(Pal 0.1(251 0.2(50) 0.3(751 0.4(1001 0.5(125) 0.611501 0.7(1751 0.3(2001 1 2eM a } _# F 300 .0,• cfm(Ls) =ME cfm(Ls) cfm(Us] cite(Lls1 clm(Us) cfm(Ifs) 1 0 `'s�� ©- Net supply airflow 146(69) 129(611 116(55) 105 1491 96(451 88(411 80(381 73(34) iti rF ©O Tutha.anew 250 c tnx , x ?: 08 2007, Gross exhaust airflow 148(701 133(63) 120(57) 107(511 95(45) 85(401 73(35) 63 1301 d N 0.6 if vt" `". 150 y =)urtmo Mode is an intarnrttent mode only.It can be activated with the RTS2.RTS5 and the EGO Quo`,for ui,to 61)rnnmtes. a j. ,`, �a. u;., 1 Only the data of the nor niai speed are HV)certified. us Co 04 ,.0 f © a 0 _-,; too—" 0 25 50 75 100 125 150 175 200 Airflow(cfml Energy performance Supply temperature Not argue, Consumed pm er Sensible recovery Apparent sensible Latent recovery/moisture Heating efficiency effectiveness transfer f C clm Lis 1N v/o ab _ 32 0 52 24 46 70 80 -0 p 32 0 99 47 102 64 ��p 6 y 73 -Li C4 a , 1 11.6`S. gala .... °t r,w„ - , n�' '8' � -` i ,.. i i:1;d..c ays Requirements and standards • Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators • Complies with the CSA C22.2 no. 113 Standard applicable to ventilators • Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators • Technical data was obtained from published results of test relating to CSA C439 Standards • HVI certified and ENERGY STAR®qualified* This product earned the ENERGY STAR&by nreetiny strict efficiency guidelines set by Natural Resources Canada and the US EPA.It meets ENERGY STAR®requirements only when used in Canada. Contacts Distributed by: Submitted by: Date: Quantity: Model: Proiect#: Comments: Location: Architect: Engineer: Contractor: United States 10048 Industrial Blvd.•Lenexa,KS 66215•1.800.747.1762•www.fantech.net Canada 50 Kanalfiela Way•Bouctouche,NB E4S 3M5.1.800.565.354B•www.fantech.net i tjf.� fantech Systerttair reserves the right to nndi(y,at any time and without notice,any or all of its products'features,designs.compo- :s!': •. nerds and specificatuleadership position. •�••ots to maintain their technological ~•.. a systemair company