inspectionsFraming /Firestopping Inspection Report
Office No.(518)761-8256 Date Inspection request received
Queensbury Building &Code Enforcement Arrive:am/pm,¢Depart:am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:ee
PERMIT #:One J27
INSPECT ON:_?
NAME:
LOCATION:—‘TYPE OF STRUCTURE:
Y/N [NA
Framing Vo
Jack Studs /Headers
Bracing /Bridging
Joist hangers
Jack Posts /Main Beams
Exterior sheeting nailed properly
12"0.Headroom 6 ft.8 in.
Stairwells 36 in.or more
Headroom 6 fi.8 in
COMMENTS|Notches /Holes /Bearing Walls
‘Metal Strapping for Notches Top Plate
1%(w)16 gauge (8)16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Tce and snow shield 24 inches from wall |
|
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
Firestopping
|
Penetration sealed
16 inch insulation in cavity min.
|Garage Fire Separation
House side %inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
|Windows Habitable Space /Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above /below grade
5.0 sf grade
L'SueHeringway'Building Codes.Inspection.FORMSiFraming Firestopping Inspection Report doc January 28,2003
4
Residential Final Inspection ee
Office No,(518)761-8256 Date Inspection request received:;Queensbury Building &Code Enforcement Arrive:part:><pm TED
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials
PERMIT #:02427
DATE:BS Abs de
Comments
‘NAME:
LOCATION:
‘TYPE OF STRUCTURE:
Chimney Hit /"B*Vent/Direct Vent Location I
Fresh Air Intake3inchPlumbVentthroughroof
Roof Complete ae‘Guard 30 in.or more@stairs,decks,patios Vv.1
Guard at stairwell at 34 in.or more
Guard at deck,porches 36 in,or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.|Platform at all exterior doors
‘Inerior Handrails stairs 2 or more risers
‘Grade away from foundation 6 in.with 10 R.
Handrail Termination at Newell Post or Wall8inchclearancetosillplate
Gas Valve shut-off exposed /regulator 18°above grade
Gas Fummace shut-off within 30 ft.or within line of siteilFurnaceshut-off at entrance to furmace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed
Interior privacy/trim/doors /main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing eg‘Window in stairwells safety glazing
Tnterior Smoke Detectors:
Every level:1 Bvery Bedroom:
Outside every bedroom area:___InterConnected:Battery backup:
‘Bathroom Fans,if'no window
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation {
Floor truss,draft stopping finished basement 1,000 sf 1
Emergency egress below grade |
‘Basement stairs closed rise >4 inches
%hour fire door /door closer
Garage fireproofing
‘Duct work Sealed properly
‘Aitic access 30 in.x24 i.x 30 in.it)In accessible area
Crawl Spaces 18”x 24%access,1 sq.f.-150 sq.fi.vents
‘Building No./Address visible from road
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
‘As Built Septic System /Sewer Dept.Inspection Sticker
Flood Plain Certification,ifrequired
‘Okay to issue C/C (Cert.Of Compliance)
‘Okay to issue Temporary C/O (Cert.Of Occupancy)__|‘Okay to issue Permanent C/O (Cert,Of Occupancy)|
iSvef¥emingwvay Building Codes Inspection FORMS\Res.Final Insp.form doe eed January 28,2003
SNLLINS,
|
1
1
(COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
‘Main Office 176 Doe Run Road -Manhelm,PA 17545
MUNICIPAL CERTIFICATE -ELECTRICAL APPROVAL
Installed By.
“The conditions following governed the issuance of this certifieate,and any certificate previously issued is
cancelled:-
“This centifieate only covers the electrical equipment and installation conditions as of date.Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection
Inspectors of this Company shall have the privilege of making ingffetions at any time,and if its
Member NEPAG LAW.