inspectionQueensbury Building &Code Enforcement -Residential Final Inspection
Office No.(518)761-8256 Arrive:am/pm Depart:im/pm
Date Inspection request received:Inspector"s Initials::A )NAME:=PERMIT a 4 7/
LOCATION:DATE:|TYPE OF STRUCTURE
VEL A d /v Comments
z Yes|No|N/A L
Building Number /Address visible from road dewo
Chimmey Height /"B”Vent/Direct Vent Location
Fresh Air Intake e3inchPlumbingVentthroughroofminimum6inches
Roof Complete /Exterior Finish Complete
Platform at all exterior doors
‘Guards at stairs,decks,patios more than 30 inches above grade
‘Guard at stairwell at 34 inches or more I
‘Guard at deck,porches 36 inches or more [
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers VAS \Grade away from foundation 6 inches with 10 feet SMiE:
G inch clearance to sill pate a
‘GasValve shut-off exposed /reglaor 18 inches above gage
Tnterior privacy/trim doors /main entrance 36 inches
Bathroom /Kitchen watertight
Safety glazing /Window in stairwells safety glazing
Interior Smoke Detectors:
Every level:Every Bedroom:
Outside every bedroom area:
Inter Connected:Baitery backup:
Carbon Monoxide Detector
Aitic access 30 inches x 22 inches x 30 inches (height)in accessible area
Craw Spaces 18 inch x 24 inch access,I sq,fl.-150 sq.ft.vents
Bathroom Fans,ifno window.
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
‘Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
‘Low water shut-off boiler
Relief Valve(s)installed /Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum ¥"Gypsum
‘Basement stairs closed rise >4 inches
Garage Floor Pitched
‘Garage fireproofing /¥%hour fire door/door closer
‘Duct work Sealed proper!
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
‘As Built Septic System /Sewer Dept.Inspection Sticker ISitePlan/Variance required
Flood Plain Certification,if required
‘Okay to issue CC or C/O {Temporary /Permanent ]
L:\Building &Codes Forms\Building &Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc