Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
HVAC
APR022019 TOWN OF QUEENSBURY BUILDING&CODES 116 Burnt Hills Dr HVAC Load Calculations for The Michaels Group imp V AC RESIDENTIAL HVAC LOADS Prepared By: Jason Dion Appolo Heating 308.12-1-36 RC-0168-2019 Schenectady Ny 868eck52306 Michaels Group Homes LLC 116 Burnt Hills Dr, Lot 11 Friday, March 22, 2019 SFD w/gas FP 1939 s.f., Gar. 759 s.f. Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 116 Burnt Hills Dr Schenectady,NY 12306 Page 2 Project Report General Project Information Project Title: 116 Burnt Hills Dr Designed By: The Michaels Group Project Date: Friday, March 22, 2019 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Jason Dion Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 Design Data Reference City: Glens Falls, New York Building Orientation: Front door faces Northwest Daily Temperature Range: Medium Latitude: 43 Degrees Elevation: 328 ft. Altitude Factor: 0.988 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -4 -4.56 n/a n/a 70 n/a Summer: 85 71 51% 50% 75 27 Check Figures Total Building Supply CFM: 1,275 CFM Per Square ft.: 0.421 Square ft. of Room Area: 3,026 Square ft. Per Ton: 1,095 Volume (ft3): 25,215 BuddingLoads Total Heating Required Including Ventilation Air: 78,189 Btuh 78.189 MBH Total Sensible Gain: 29,109 Btuh 88 % Total Latent Gain: 4,040 Btuh 12 % Total Cooling Required Including Ventilation Air: 33,148 Btuh 2.76 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\116 Burnt Hills Dr.rh9 Friday, March 22, 2019, 11:00 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 44) 116 Burnt Hills Dr Schenectady,NY 12306 -Page 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb_-- Rel.Hum Rel.Hum Dry Bulb Difference Winter: -4 -4.56 80% n/a 70 n/a Summer: 85 71 51% 50% 75 27.41 Duct Sizing inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.370 AC/hr 0.190 AC/hr 155 CFM 80 CFM Infiltration Actual: 0.370 AC/hr 0.190 AC/hr Above Grade Volume: X 25.215 Cu.ft. X 25.215 Cu.ft. 9,330 Cu.ft./hr 4,791 Cu.ft./hr X 0.0167 X 0 0167 Total Building Infiltration: 155 CFM 80 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 10.87 = (1.10 X 0.988 X 10.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 18.42 = (0.68 X 0.988 X 27.41 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 80.44 = (1.10 X 0.988 X 74.00 Winter Temp. Difference) Winter Infiltration Specified: 0.370 AC/hr(155 CFM), Construction:Average Summer Infiltration Specified: 0.190 AC/hr(80 CFM), Construction: Average Duct Load Factor Scenarios for System 1 Attic Duct Duct Surface From No. Type Description Location Ceiling Leakage Insulation Area [T]MDD 1 Supply Attic 16B 0.12 6 817 No 1 Return Attic 16B 0.12 6 151 No C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\116 Burnt Hills Dr.rh9 Friday, March 22, 2019, 11:00 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. • 116 Burnt Hills Dr Schenectady,NY 12306 Page 4 Load Preview Report Sys Sys Sys Net ft.? Seri; La t Net Sen Ht CI , Act Duct Q Scope Tog /Torj Area Gain Gail Gain Loss. 9i Size CFMr CFM CFM' Building 2.76 1,095 3,026 29,109 4,040 33,148 78,189 1,002 1,275 1,275 System 1 2.76 1,095 3,026 29,109 4.040 33,148 78,189 1,002 1,275 1,275 12x1E Supply Duct Latent 1,104 1,104 Return Duct 1,386 262 1,649 1,947 Zone 1 3,026 27,722 2,673 30,395 76,242 1,002 1,275 1.275 12x1E 1-Basement 1,024 2,258 386 2,644 15,703 206 104 104 1--6 2-Dining 143 2,206 138 2,344 7,363 97 101 101 1--6 3-Great Room 337 3,366 166 3,532 9,681 127 155 155 2--5 4-Kitchen 186 1,395 66 1,461 3,703 49 64 64 1--5 5-Powder Room 30 545 12 557 654 9 25 25 1--4 6-Mud Room 58 1,059 60 1,119 2,524 33 49 49 1--4 7-Foyer 76 1,143 88 1,231 3,284 43 53 53 1--4 8-Home Office 186 2,031 101 2,132 5,504 72 93 93 1--6 9-Master Bedroom 306 3,891 723 4,614 8,027 105 179 179 2--6 10-Bedroom 3 168 2,920 391 3,311 5,366 71 134 134 2--5 11-Laundry 73 1,154 49 1,203 2,561 34 53 53 1--4 12-Bedroom 2 166 2,577 391 2,968 4,943 65 119 119 2--4 13-Loft 81 713 0 713 1,077 14 33 33 1--4 14-Bath 1 67 994 24 1,018 1,669 22 46 46 1--4 15-Master Bath 125 1,471 78 1,549 4,184 55 68 68 1--5 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\116 Burnt Hills Dr.rh9 Friday, March 22, 2019, 11:00 AM • Rhvac Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 4 116 Burnt Hills Dr Schenectady NY 12306 Pa e 5 j Duct Size Preview , 1 Room or Minimum Maximum Rough Design SPI Duc Du Htg Gig Act. + Duct Duct Name Source i Velocity Velocity Factor L/100 Loss! Velocity Lengtt Flow. Flow Flow.____,S e._ System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 528.9 206 104 104 1--6 2-Dining Built-In 450 750 0.01 0.1 516.8 97 101 101 1--6 3-Great Room Built-In 450 750 0.01 0.1 567.8 127 155 155 2--5 4-Kitchen Built-In 450 750 0.01 0.1 470.5 49 64 64 1--5 5-Powder Room Built-In 450 750 0.01 0.1 287.2 9 25 25 1--4 6-Mud Room Built-In 450 750 0.01 0.1 558.1 33 49 49 1--4 7-Foyer Built-In 450 750 0.01 0.1 602.7 43 53 53 1--4 8-Home Office Built-In 450 750 0.01 0.1 475.8 72 93 93 1--6 9-Master Bedroom Built-In 450 750 0.01 0.1 455.8 105 179 179 2--6 10-Bedroom 3 Built-In 450 750 0.01 0.1 492.5 71 134 134 2--5 11-Laundry Built-In 450 750 0.01 0.1 608.2 34 53 53 1--4 12-Bedroom 2 Built-In 450 750 0.01 0.1 679.1 65 119 119 2--4 13-Loft Built-In 450 750 0.01 0.1 375.8 14 33 33 1--4 14-Bath 1 Built-In 450 750 0.01 0.1 523.9 22 46 46 1--4 15-Master Bath Built-In 450 750 0.01 0.1 496.2 55 68 68 1--5 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 850.1 1,002 1,275 1,275 12x16 Summary System 1 Heatina Flow: 1002 Coolina Flow: 1275 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\116 Burnt Hills Dr.rh9 Friday, March 22, 2019, 11:00 AM • Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 116 Burnt Hills Dr Schenectady, NY 12306 Page 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Pella Vinyl: Glazing-Pella Vinyl, U-value 0.31, SHGC 0.28 288.1 6,610 0 3,708 3,708 Pella Slider: Door-Slider, U-value 0.3 40.8 906 0 257 257 Fire Rated: Door-Fire Rated, U-value 0.17 21 264 0 75 75 Front Door TMG: Door-TMG Entry, U-value 0.17 21 264 0 75 75 12E-0bm: Wall-Frame, R-19 insulation in 2 x 6 stud 889.2 6,779 0 586 586 cavity, no board insulation, brick finish, metal studs, U-value 0.103 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 2132.9 10,257 0 1,425 1,425 cavity, no board insulation, siding finish, wood studs, U-value 0.065 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 986.1 1,898 0 1,154 1,154 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation, U-value 0.026 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1024 1,894 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24'wide, U-value 0.025 19A-Ocp: Floor-Over enclosed crawl space, No insulation 1649.1 13,523 0 1,826 1,826 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood, U-value 0.295 19A-Otp: Floor-Over enclosed crawl space, No insulation 352.6 3,124 0 422 422 on exposed walls, sealed or vented space, passive, no floor insulation, tile or vinyl, U-value 0.368 Subtotals for structure: 45,519 0 9,528 9,528 People: 4 1,200 1,600 2,800 Equipment: 0 0 0 Lighting: 2480 8,457 8,457 Ductwork: 20,163 1,367 8,467 9,834 Infiltration: Winter CFM: 155, Summer CFM: 80 12,507 1,473 867 2,340 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 190 190 Total Building Load Totals: 78,189 4,040 29,109 33,148 Check Figures Total Building Supply CFM: 1,275 CFM Per Square ft.: 0.421 Square ft. of Room Area: 3,026 Square ft. Per Ton: 1,095 Volume (ft3): 25,215 Building Loads Total Heating Required Including Ventilation Air: 78,189 Btuh 78.189 MBH Total Sensible Gain: 29,109 Btuh 88 % Total Latent Gain: 4,040 Btuh 12 % Total Cooling Required Including Ventilation Air: 33,148 Btuh 2.76 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\116 Burnt Hills Dr.rh9 Friday, March 22, 2019, 11:00 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 11lir 116 Burnt Hills Dr Schenectady,NY 12306 Page 7 Building Pie Chart Infiltration 16% Floor 24% Roof 2% rb f$ Ductwork 26% L. • „ Wall 22% .., Door 2% Glass 8% AED Excursion 1% Floor 7% Infiltration 7% Roof 3% Wall 6% Glass 110/o Ductwork 30% Door 1% People 8% Lighting 26% C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\116 Burnt Hills Dr.rh9 Friday, March 22, 2019, 11:00 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 116 Burnt Hills Dr Schenectady,NY 12306 111 Page 8 System 1 Room Load Summary Htg Min Run Run Clg CIg Min Act Room Area Sens Htg Duct Duct Sens Lat CIg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 1,024 15,703 206 1-6 529 2,258 386 104 104 2 Dining 143 7,363 97 1-6 517 2,206 138 101 101 3 Great Room 337 9,681 127 2-5 568 3,366 166 155 155 4 Kitchen 186 3,703 49 1-5 471 1,395 66 64 64 5 Powder Room 30 654 9 1-4 287 545 12 25 25 6 Mud Room 58 2,524 33 1-4 558 1,059 60 49 49 7 Foyer 76 3,284 43 1-4 603 1,143 88 53 53 8 Home Office 186 5,504 72 1-6 476 2,031 101 93 93 9 Master Bedroom 306 8,027 105 2-6 456 3,891 723 179 179 10 Bedroom 3 168 5,366 71 2-5 492 2,920 391 134 134 11 Laundry 73 2,561 34 1-4 608 1,154 49 53 53 12 Bedroom 2 166 4,943 65 2-4 679 2,577 391 119 119 13 Loft 81 1,077 14 1-4 376 713 0 33 33 14 Bath 1 67 1,669 22 1-4 524 994 24 46 46 15 Master Bath 125 4,184 55 1-5 496 1,471 78 68 68 Duct Latent 1,104 Return Duct 1,947 1,386 262 System 1 total 3,026 78,189 1,002 29,109 4,040 1,275 1,275 System 1 Main Trunk Size: 12x18 in. Velocity: 850 ft./min Loss per 100 ft.: 0.100 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.76 88%/ 12% 29,109 4,040 33,148 Actual: 2.40 75%/25% 21,600 7,200 28,800 Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B-* 13ACXN030-230-** Indoor Model: C35-24B+TDR+TXV Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 64,000 Btuh 28,800 Btuh Sensible Capacity: n/a 21,600 Btuh Latent Capacity: n/a 7,200 Btuh AHRI Reference No.: n/a 8269470 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\116 Burnt Hills Dr.rh9 Friday, March 22, 2019, 11:00 AM