ResCheck REScheck Software Version 4.6.3 r r
W
m
reCtf Compliance Certificate z04
Eg ® 021
Project New Residence FL COPY "� 1 6
7,_ se_ ®�
Energy Code: 2015 IECC �`� I--
Location: Glens Falls, New York
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 2,802 ft2 289.16-1-10 RC-0170-2019
Glazing Area 13% Garvey, Stacey & Marc
Climate Zone: 6 (7635 HDD) 57 Grand View Dr
Permit Date:
Permit Number: SFD w/gas FP 3077 s.f., Gar. 1188 s.f.
Construction Site: Owner/Agent: Designer/Contractor:
Lot#9 Grand View Drive Marc&Stacey Garvey Ethan Peter Hall
Queensbury, NY 12804 43 Hunter Lane Rucinski Hall Architecture
Queensbury, NY 12804 134 Dix Ave
REVIEWED FOR Glens Falls, NY 12801
518-741-0268
ENERGY CODE COMPLIANCE ephall@nycap.rr.com
Compliance: Passes using UA trade-off
Compliance: 3.8%Better Than Code Maximum UA: 474 Your UA: 456
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or U-Factor UA
Perimeter R-Value R-Value
Ceiling 1: Raised or Energy Truss 2,802 38.0 0.0 0.025 70
Ceiling 2: Raised or Energy Truss 320 38.0 0.0 0.025 8
Wall 1: Wood Frame, 16"o.c. 721 21.0 3.6 0.046 27
Window 1:Wood Frame:Double Pane with Low-E 69 0.290 20
Door 1: Solid 55 0.300 17
Wall 2:Wood Frame, 16"o.c. 341 21.0 3.6 0.046 14
Window 2:Wood Frame:Double Pane with Low-E 30 0.290 9
Wall 3: Wood Frame, 16"o.c. 1,191 21.0 3.6 0.046 43
Window 3: Wood Frame:Double Pane with Low-E 84 0.290 24
Window 4:Wood Frame:Double Pane with Low-E 51 0.290 15
Door 2: Glass 42 0.320 13
Door 3: Glass 42 0.320 13
Door 4: Glass 42 0.320 13
Wall 4: Wood Frame, 16"o.c. 662 21.0 3.6 0.046 30
Door 5: Solid 20 0.300 6
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 1 of10
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor
Perimeter
Wall 5:Wood Frame, 24"o .c. 242 21.0 0.0 0.056 i4
Wall 6: Wood Frame, 16"o.c. 112 21.0 3.6 0.046 4
Window 5:Wood Frame:Double Pane with Low-E 28 0.290 8
Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 320 38.0 0.0 0.026 8
Basement Wall 1: Solid Concrete or Masonry 1,541 0.0 15.0 0.048 73
Wall height: 7.9'
Depth below grade: 7.0'
Insulation depth: 7.5'
Window 6:Vinyl/Fiberglass Frame:Double Pane with Low-E 30 0.290 9
Crawl 1: Solid Concrete or Masonry 826 0.0 15.0 0.055 18
Wall height: 5.9'
Depth below grade: 5.5'
Insulation depth: 5.5'
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.3 and to comply with the mandatory requirements ' d in RE he Inspection Checklist.///��
Ethan Peter Hall-Architect M Ogg 1�/9
Name-Title Signati Date
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 2 of10
REScheck Software VersionChecklist 4.6.3
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the Location on plans/spec:A-
building envelope.Thermal Not Observable 1
envelope represented on [Not Applicable
construction documents. _
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for ❑Not Observable Location on plans/spec:A-
[PR3]1 lighting and mechanical systems. ;1
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is! Heating: Heating: ❑Complies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr Btu/hr '❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Location on plans/spec:A-
;, Manual J or other methods Btu/hr 1
Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 I Low Impact(Tier 3)
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 3 of10
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID _
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO4]1 insulation R-value.Where interior R_ R- ❑Does Not table for values.
insulation is used,verification
may need to occur during ❑Not Observable
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies Requirement will be met.
[FO5]1 insulation installed per ❑Does Not
manufacturer's instructions. [Not Observable Location on plans/spec:A-
❑Not Applicable 1
402.2.9 Conditioned basement wall ft ft !❑Complies See the Envelope Assemblies
[FO6]1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall.
['Not Observable
❑Not Applicable
402.2.11 Unvented crawl space wall R- R- ❑Complies See the Envelope Assemblies
[FO7]1 insulation R-value. R- R- ❑Does Not table for values.
['Not Observable
ElNot Applicable
303.2 Unvented crawl space wall ElComplies Requirement will be met.
[FO8]1 insulation installed per ❑Does Not
manufacturer's instructions. ❑Not Observable Location on plans/spec:A-
❑Not Applicable 1
402.2.11 Unvented crawl space continuous ❑Complies Requirement will be met.
[FO9]1 vapor retarder installed over ❑Does Not
exposed earth,joints overlapped ❑Not Observable Location on plans/spec:A-
by 6 in.and sealed,extending at 1
least 6 in. up and attached to the ❑Not Applicable
wall.
402.2.11 'Unvented crawl space wall in. in. ❑Complies See the Envelope Assemblies
[FO10]1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall.
['Not Observable
EJNot Applicable
303.2.1 A protective covering is installed ;, ❑Complies Exception: Requirement is
[FOil]z to protect exposed exterior ❑Does Not not applicable.
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is
[FO12]z controls installed. ❑Does Not not applicable.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) I 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3)
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 4 of10
• Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U- U- DComplies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
2- ❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- DComplies See the Envelope Assemblies
402.3.1, average). ElDoes Not table for values.
402.3.3,
['Not402.3.6, Not Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 U-factors of fenestration products DComplies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or [Not Observable Location on plans/spec:A-
,,
taken from the default table. 1
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier DComplies Requirement will be met.
[FR23]1 installed per manufacturer's ❑Does Not
instructions. Location on plans/spec:A-
'..?, ❑Not Observable ;1
❑Not Applicable
402.4.3 Fenestration that is not site built DComplies Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC or Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures DComplies Exception: Requirement is
[FR16]2 sealed at housing/interior finish ❑Does Not not applicable.
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. ❑Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics DComplies Exception: Ducts located
[FR12]1 insulated >= R-8 where duct is ❑Does Not completely inside the
>= 3 inches in diameter and >= ❑Not Observable building envelope.
R-6 where < 3 inches.Supply and,
return ducts in other portions of ( ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for<3 inches in diameter.
403.3.3.5 Building cavities are not used as ! DComplies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
1 [Not Observable Location on plans/spec:A-
❑Not Applicable 1
403.4 HVAC piping conveying fluids R- R- DComplies Exception: Requirement is
[FR17]2 above 105°F or chilled fluids ❑Does Not not applicable.
below 55°F are insulated to>_R-
3 ❑Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC DComplies Exception: Requirement is
[FR24]1 piping. ❑Does Not not applicable.
_ ['Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- DComplies Exception: Requirement is
[FR18]2 >_R-3. ❑Does Not not applicable.
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are DComplies Requirement will be met.
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Not Observable Location on plans/spec:A-
1
❑Not Applicable
[1 'High Impact(Tier 1) 1 2 'Medium Impact(Tier 2) L 3 'Low Impact(Tier 3)
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 5 of10
Additional Comments/Assumptions:
Cl High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 6 of10
•
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID _ _
303.1 All installed insulation is labeled :, DComplies Requirement will be met.
[IN13]2 or the installed R-values ❑Does Not
provided. ❑Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- DComplies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 ❑ Steel ❑ Steel :Not Observable
❑Not Applicable
303.2, Floor insulation installed per DComplies Requirement will be met.
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the Location on plans/spec:A-
underside of the subfloor,or floor ❑Not Observable 1
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing,or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a` R- R- DComplies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable
[IN311 exterior,the exterior insulation
requirement applies(FR10). III Steel El Steel ❑Not Applicable
303.2 Wall insulation is installed per DComplies Requirement will be met.
[IN4i1 manufacturer's instructions. ❑Does Not
❑Not Observable Location on plans/spec:A-
1
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) j 2 [Medium Impact(Tier 2) I 3jLow Impact(Tier 3)
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 7 of10
•
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ElDoes Not table for values.
402.2.2, ❑ Steel ❑ Steel ['Not Observable
402.2.6
[Fl1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. ElDoes Not
[FI2]1 Blown insulation marked every ['Not Observable Location on plans/spec:A-
300 ft2. 1
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies Requirement will be met.
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that ❑Not Observable Location on plans/spec:A-
extends over insulation. 1
❑Not Applicable
402.2.4 ,Attic access hatch and door R- R- ❑Complies Requirement will be met.
[FI3]1 insulation .__R-value of the ElDoes Not
adjacent assembly. Location on plans/spec:A-
❑Not Observable 1
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met.
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8. ❑Not Observable Location on plans/spec:A-
1
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Exception:All ducts and air
[Fl4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not handlers are located within
<=3 cfm/100 ft2 without air ['Not Observable conditioned space.
handler @ 25 Pa. For rough-in
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception:All ducts and air
[FI27]1 determine air leakage with ft2 ft2 ElDoes Not handlers are located within
either: Rough-in test:Total !❑Not Observable conditioned space.
leakage measured with a
pressure differential of 0.1 inch ❑Not Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met.
[FI24]1 by manufacturer at<=2%of ElDoes Not
design air flow. Location on plans/spec:A-
❑Not Observable ,1
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies Requirement will be met.
[FI9]2 installed for control of primary ElDoes Not
heating and cooling systems and Location on plans/spec: A-
initially set by manufacturer to 1
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies Exception: Requirement is
[FI10]2 on heat pumps. ElDoes Not not applicable.
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies Exception: Requirement is
[FI11]2 systems have automatic or ❑Does Not not applicable.
accessible manual controls.
['Not Observable
❑Not Applicable
[1'High Impact(Tier 1) 12 IMedium Impact(Tier 2) 13-ILow Impact(Tier 3) I
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 8 of10
•
Section Plans Verified" Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system ❑Complies Exception: Requirement is
[FI25]2 fans not part of tested and listed ❑Does Not not applicable.
HVAC equipment meet efficacy
and air flow limits. ['Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is
[F126]2 through one-or two-pipe heating ❑Does Not not applicable.
systems have outdoor setback
control to lower boiler water ['Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies Exception: Requirement is
[FI2812 have a circulation pump.The ❑Does Not not applicable.
system return pipe is a dedicated
return pipe or a cold water supply ['Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is
[F129]2 comply with IEEE 515.1 or UL ❑Does Not not applicable.
515.Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies Exception: Requirement is
[FI30]2 have recirculation pumps that ❑Does Not not applicable.
pump water from a heated water
supply pipe back to the heated ['Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F.
403.5.4 Drain water heat recovery units ❑Complies Requirement will be met.
[FI31]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side ['Not Observable Location on plans/spec:A-
pressure loss of drain water heat 1
recovery units< 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies Requirement will be met.
[FI611 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps. Location on plans/spec:A-
Does not apply to low-voltage Not Observable 1
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met.
[FI23]3 no continuous pilot light. ❑Does Not
t+' ❑Not Observable Location on plans/spec:A-
1
❑Not Applicable
High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3)
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 9 of10
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. ❑Complies Requirement will be met.
[FI7]2 ❑Does Not
['Not Observable
❑Not Applicable
303.3 Manufacturer manuals for DComplies Requirement will be met.
[FI18]3 mechanical and water heating ElDoes Not
systems have been provided.
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
[1 IHigh Impact(Tier 1) 1 2 'Medium Impact(Tier 2) ] 3 LLow Impact(Tier 3)
Project Title: New Residence Report date: 03/29/19
Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 10 of10
i20 IE
C Efficie15ncyCC Energy Certificate
Insulation Rating R-Value
Above-Grade Wall 24.60
Below-Grade Wall 15.00
Floor 38.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.29
Door 0.30
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments