ResCheck REScheck Software Version 4.6.3 r r W m reCtf Compliance Certificate z04 Eg ® 021 Project New Residence FL COPY "� 1 6 7,_ se_ ®� Energy Code: 2015 IECC �`� I-- Location: Glens Falls, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 2,802 ft2 289.16-1-10 RC-0170-2019 Glazing Area 13% Garvey, Stacey & Marc Climate Zone: 6 (7635 HDD) 57 Grand View Dr Permit Date: Permit Number: SFD w/gas FP 3077 s.f., Gar. 1188 s.f. Construction Site: Owner/Agent: Designer/Contractor: Lot#9 Grand View Drive Marc&Stacey Garvey Ethan Peter Hall Queensbury, NY 12804 43 Hunter Lane Rucinski Hall Architecture Queensbury, NY 12804 134 Dix Ave REVIEWED FOR Glens Falls, NY 12801 518-741-0268 ENERGY CODE COMPLIANCE ephall@nycap.rr.com Compliance: Passes using UA trade-off Compliance: 3.8%Better Than Code Maximum UA: 474 Your UA: 456 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter R-Value R-Value Ceiling 1: Raised or Energy Truss 2,802 38.0 0.0 0.025 70 Ceiling 2: Raised or Energy Truss 320 38.0 0.0 0.025 8 Wall 1: Wood Frame, 16"o.c. 721 21.0 3.6 0.046 27 Window 1:Wood Frame:Double Pane with Low-E 69 0.290 20 Door 1: Solid 55 0.300 17 Wall 2:Wood Frame, 16"o.c. 341 21.0 3.6 0.046 14 Window 2:Wood Frame:Double Pane with Low-E 30 0.290 9 Wall 3: Wood Frame, 16"o.c. 1,191 21.0 3.6 0.046 43 Window 3: Wood Frame:Double Pane with Low-E 84 0.290 24 Window 4:Wood Frame:Double Pane with Low-E 51 0.290 15 Door 2: Glass 42 0.320 13 Door 3: Glass 42 0.320 13 Door 4: Glass 42 0.320 13 Wall 4: Wood Frame, 16"o.c. 662 21.0 3.6 0.046 30 Door 5: Solid 20 0.300 6 Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 1 of10 Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor Perimeter Wall 5:Wood Frame, 24"o .c. 242 21.0 0.0 0.056 i4 Wall 6: Wood Frame, 16"o.c. 112 21.0 3.6 0.046 4 Window 5:Wood Frame:Double Pane with Low-E 28 0.290 8 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 320 38.0 0.0 0.026 8 Basement Wall 1: Solid Concrete or Masonry 1,541 0.0 15.0 0.048 73 Wall height: 7.9' Depth below grade: 7.0' Insulation depth: 7.5' Window 6:Vinyl/Fiberglass Frame:Double Pane with Low-E 30 0.290 9 Crawl 1: Solid Concrete or Masonry 826 0.0 15.0 0.055 18 Wall height: 5.9' Depth below grade: 5.5' Insulation depth: 5.5' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.3 and to comply with the mandatory requirements ' d in RE he Inspection Checklist.///�� Ethan Peter Hall-Architect M Ogg 1�/9 Name-Title Signati Date Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 2 of10 REScheck Software VersionChecklist 4.6.3 Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the Location on plans/spec:A- building envelope.Thermal Not Observable 1 envelope represented on [Not Applicable construction documents. _ 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for ❑Not Observable Location on plans/spec:A- [PR3]1 lighting and mechanical systems. ;1 Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is! Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr '❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Location on plans/spec:A- ;, Manual J or other methods Btu/hr 1 Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 I Low Impact(Tier 3) Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID _ 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies Requirement will be met. [FO5]1 insulation installed per ❑Does Not manufacturer's instructions. [Not Observable Location on plans/spec:A- ❑Not Applicable 1 402.2.9 Conditioned basement wall ft ft !❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ['Not Observable ❑Not Applicable 402.2.11 Unvented crawl space wall R- R- ❑Complies See the Envelope Assemblies [FO7]1 insulation R-value. R- R- ❑Does Not table for values. ['Not Observable ElNot Applicable 303.2 Unvented crawl space wall ElComplies Requirement will be met. [FO8]1 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable Location on plans/spec:A- ❑Not Applicable 1 402.2.11 Unvented crawl space continuous ❑Complies Requirement will be met. [FO9]1 vapor retarder installed over ❑Does Not exposed earth,joints overlapped ❑Not Observable Location on plans/spec:A- by 6 in.and sealed,extending at 1 least 6 in. up and attached to the ❑Not Applicable wall. 402.2.11 'Unvented crawl space wall in. in. ❑Complies See the Envelope Assemblies [FO10]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ['Not Observable EJNot Applicable 303.2.1 A protective covering is installed ;, ❑Complies Exception: Requirement is [FOil]z to protect exposed exterior ❑Does Not not applicable. insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is [FO12]z controls installed. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) I 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 4 of10 • Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- DComplies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable 2- ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- DComplies See the Envelope Assemblies 402.3.1, average). ElDoes Not table for values. 402.3.3, ['Not402.3.6, Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products DComplies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or [Not Observable Location on plans/spec:A- ,, taken from the default table. 1 ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier DComplies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. Location on plans/spec:A- '..?, ❑Not Observable ;1 ❑Not Applicable 402.4.3 Fenestration that is not site built DComplies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC or Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures DComplies Exception: Requirement is [FR16]2 sealed at housing/interior finish ❑Does Not not applicable. and labeled to indicate <_2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics DComplies Exception: Ducts located [FR12]1 insulated >= R-8 where duct is ❑Does Not completely inside the >= 3 inches in diameter and >= ❑Not Observable building envelope. R-6 where < 3 inches.Supply and, return ducts in other portions of ( ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for<3 inches in diameter. 403.3.3.5 Building cavities are not used as ! DComplies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not 1 [Not Observable Location on plans/spec:A- ❑Not Applicable 1 403.4 HVAC piping conveying fluids R- R- DComplies Exception: Requirement is [FR17]2 above 105°F or chilled fluids ❑Does Not not applicable. below 55°F are insulated to>_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC DComplies Exception: Requirement is [FR24]1 piping. ❑Does Not not applicable. _ ['Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- DComplies Exception: Requirement is [FR18]2 >_R-3. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are DComplies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable Location on plans/spec:A- 1 ❑Not Applicable [1 'High Impact(Tier 1) 1 2 'Medium Impact(Tier 2) L 3 'Low Impact(Tier 3) Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 5 of10 Additional Comments/Assumptions: Cl High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 6 of10 • Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID _ _ 303.1 All installed insulation is labeled :, DComplies Requirement will be met. [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- DComplies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel :Not Observable ❑Not Applicable 303.2, Floor insulation installed per DComplies Requirement will be met. 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the Location on plans/spec:A- underside of the subfloor,or floor ❑Not Observable 1 framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a` R- R- DComplies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable [IN311 exterior,the exterior insulation requirement applies(FR10). III Steel El Steel ❑Not Applicable 303.2 Wall insulation is installed per DComplies Requirement will be met. [IN4i1 manufacturer's instructions. ❑Does Not ❑Not Observable Location on plans/spec:A- 1 ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) j 2 [Medium Impact(Tier 2) I 3jLow Impact(Tier 3) Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 7 of10 • Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ElDoes Not table for values. 402.2.2, ❑ Steel ❑ Steel ['Not Observable 402.2.6 [Fl1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ElDoes Not [FI2]1 Blown insulation marked every ['Not Observable Location on plans/spec:A- 300 ft2. 1 ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies Requirement will be met. [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable Location on plans/spec:A- extends over insulation. 1 ❑Not Applicable 402.2.4 ,Attic access hatch and door R- R- ❑Complies Requirement will be met. [FI3]1 insulation .__R-value of the ElDoes Not adjacent assembly. Location on plans/spec:A- ❑Not Observable 1 ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met. [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable Location on plans/spec:A- 1 ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Exception:All ducts and air [Fl4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not handlers are located within <=3 cfm/100 ft2 without air ['Not Observable conditioned space. handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception:All ducts and air [FI27]1 determine air leakage with ft2 ft2 ElDoes Not handlers are located within either: Rough-in test:Total !❑Not Observable conditioned space. leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met. [FI24]1 by manufacturer at<=2%of ElDoes Not design air flow. Location on plans/spec:A- ❑Not Observable ,1 ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [FI9]2 installed for control of primary ElDoes Not heating and cooling systems and Location on plans/spec: A- initially set by manufacturer to 1 code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies Exception: Requirement is [FI10]2 on heat pumps. ElDoes Not not applicable. ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies Exception: Requirement is [FI11]2 systems have automatic or ❑Does Not not applicable. accessible manual controls. ['Not Observable ❑Not Applicable [1'High Impact(Tier 1) 12 IMedium Impact(Tier 2) 13-ILow Impact(Tier 3) I Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 8 of10 • Section Plans Verified" Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies Exception: Requirement is [FI25]2 fans not part of tested and listed ❑Does Not not applicable. HVAC equipment meet efficacy and air flow limits. ['Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is [F126]2 through one-or two-pipe heating ❑Does Not not applicable. systems have outdoor setback control to lower boiler water ['Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies Exception: Requirement is [FI2812 have a circulation pump.The ❑Does Not not applicable. system return pipe is a dedicated return pipe or a cold water supply ['Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is [F129]2 comply with IEEE 515.1 or UL ❑Does Not not applicable. 515.Controls automatically adjust the energy input to the ['Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies Exception: Requirement is [FI30]2 have recirculation pumps that ❑Does Not not applicable. pump water from a heated water supply pipe back to the heated ['Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies Requirement will be met. [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side ['Not Observable Location on plans/spec:A- pressure loss of drain water heat 1 recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies Requirement will be met. [FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Location on plans/spec:A- Does not apply to low-voltage Not Observable 1 lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met. [FI23]3 no continuous pilot light. ❑Does Not t+' ❑Not Observable Location on plans/spec:A- 1 ❑Not Applicable High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 9 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. ❑Complies Requirement will be met. [FI7]2 ❑Does Not ['Not Observable ❑Not Applicable 303.3 Manufacturer manuals for DComplies Requirement will be met. [FI18]3 mechanical and water heating ElDoes Not systems have been provided. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: [1 IHigh Impact(Tier 1) 1 2 'Medium Impact(Tier 2) ] 3 LLow Impact(Tier 3) Project Title: New Residence Report date: 03/29/19 Data filename: Y:\Garvey Residence\Const Dwg's\Garvey.rck Page 10 of10 i20 IE C Efficie15ncyCC Energy Certificate Insulation Rating R-Value Above-Grade Wall 24.60 Below-Grade Wall 15.00 Floor 38.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.30 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments