inspection 06032019INSPECTION WORKSHEET (BINS-003214-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0170-2019Case Module:Permit
Inspection Date:Mon Jun 3, 2019Inspection Status:Partial Pass
Inspector:Charles DyerInspection Type:Building Foundation
Job Address:57 GRAND VIEW DRParcel Number:289.16-1-10
Queensbury, NY 12804
Contact TypeCompany NameName
ContractorHilltop Construction
Primary OwnerGarvey, Marc
Granted PermissionGarvey, Marc
ApplicantHilltop Construction
Checklist ItemPassedComments
Building Inspector NotesNO5/8/19 footings approved
5/17/19 foundation walls approved
5/28/19 foundation waterproofing approved, back fill
approved for garage only. Footings drains not completed at
side and rear of house. Call for recheck when ready.
FootingsYES5/8/19 footings approved
PiersNO
Monolithic SlabNO
Reinforcement in PlaceNO2rows of #4 continuous
Verticals to be wet set
Reinforcement in PlaceNO3 rows of #4 rebar continuous
Jun 03, 2019Page (1)
INSPECTION WORKSHEET (BINS-003214-2019)
Checklist ItemPassedComments
Footing Dowels or Keyway in placeYES#4 rebar 4' on center one foot down from top of wall
Foundation DampproofingNO
Foundation WaterproofingNO5/28/19 waterproofing verified
Footing Drain Daylight or SumpYESVerified 6/3/19
Footing Drain stone - 6 mil polyYESWith fabric
Backfill ApprovalYESFor remainder of east and north 6/3/19
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabNO
Dyer, Charles (Inspector)
Jun 03, 2019Page (2)