inspection 05082019INSPECTION WORKSHEET (BINS-002556-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0198-2019Case Module:Permit
Inspection Date:Wed May 8, 2019Inspection Status:Partial Pass
Inspector:Mark SmithInspection Type:Building Foundation
Job Address:45 ALESSIA DRParcel Number:315.-1-1.2
Queensbury, NY 12804
Contact TypeCompany NameName
ArchitectWhisonant, Bill
Primary OwnerStokes, James
ApplicantStokes, James
ApplicantStokes, Donna
Primary OwnerStokes, Donna
Granted PermissionMountain Living Landscaping
ContractorMountain Living Landscaping
Checklist ItemPassedComments
Building Inspector NotesNO5/8/19 rebar not installed as shown on plans . Foundation
walls not approved
5/8/19 document stating that rebar installed meets engineers
requirements was provided.
FootingsYESWith 2 rows # 4 continuous Approved 5/2/19
PiersYESAs per plan page 3.2
Monolithic SlabNO
May 08, 2019Page (1)
INSPECTION WORKSHEET (BINS-002556-2019)
Checklist ItemPassedComments
Reinforcement in PlaceNO
Reinforcement in PlaceYES3rows of #4 rebar horizontal at foundation walls, 2rows #4
rebar horizontal at garage frost walls. Verticals #4, four foot
on center
Footing Dowels or Keyway in placeNO
Foundation DampproofingNO
Foundation WaterproofingNO
Footing Drain Daylight or SumpYESTo daylight
Footing Drain stone - 6 mil polyYESFabric
Backfill ApprovalNO
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabNO
Smith, Mark (Inspector)
May 08, 2019Page (2)