Signed Inspection Report (12-16-2019) (4).pdfINSPECTION WORKSHEET (BINS-008224-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0625-2018 Case Module:Permit
Inspection Date:Mon Dec 16, 2019 Inspection Status:Partial Pass
Inspector:Charles Dyer Inspection Type:Building Framing
Job Address:Parcel Number:154 CLEVERDALE RD
Queensbury, NY, 12804
227.17-2-30
Contact Type Company Name Name
Primary Owner Stonewood Development of
Northeastern NY Inc
Applicant HOFFMAN, JEAN
Engineer Environmental Design Partnership, LLC
Concrete Contractor R. C. Springer Concrete
Contractor Stonewood Development of
Northeastern NY Inc
Architect McLaughlin, Tim
Granted Permission HOFFMAN, JEAN
Framing Contractor Top Notch Builders
Checklist Item Status
Building Inspector Notes Failed
12/4/19 basement framing not shown on plans, proved updated plan and res check to show basement framing
and insulation.
Load for window jacks at back stairs should continue to foundation
Load from header at kitchen area should continue to foundation
Ice and water shield not installed at this time
Truss specs not provided.
12/9/19 framing approved.
Jack Studs Headers Failed
Dec 16, 2019 Page (1)
INSPECTION WORKSHEET (BINS-008224-2019)
Checklist Item Status
12/9/19 framing approved.
Truss Specification Provided Failed
Truss specs not provided
12/9/19 framing approved.
Air Seal all Plates and Sills Failed
Air Seal All Registers at Floor Failed
Air Sealing all Joints Before Insulation Failed
Jack Posts Main Beams Failed
Load from header in kitchen area should continue to foundation
Notches Holes Bearing Walls Failed
Metal Strapping for Notches Top Plate Failed
Ice and water shield 24 inches from wall Passed
Ice and water shield not installed at this time
Verified 12/16/19
Soffits-Insulation Baffel Failed
Design Professional Sign-off, if required Failed
Dec 16, 2019 Page (2)
Dyer, Charles