Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Manual S
• Manual S Compliance Report Job: 4 APRES 201 CIRCLE Date: Apr 019 Entire House By: Plan: 1434 CERRONE BUILDERS QUEENSBURY,NY 12804 Project l3nformatio_n For: CERRONE BUILDERS Cooling _Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 23986 Btuh Entering coil DB: 75.3°F Outdoor design WB: 71.0°F Latent gain: 5517 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 29503 Btuh Indoor RH: 50% Estimated airflow: 1148 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: TCHD36S41S3+FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1 Actual airflow: 1100 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating-_Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 109578 Btuh Entering coil DB: 65.1°F Indoor design DB: 68.0°F 1pAPR 18 2019 11:1)Manufacturers Performance Data at Actual Design Conditions L 1 Equipment type: Gas furnace TOWN OF C.UEENSBURY Manufacturer: York Model: TM9X100C16MP11 L BUILDING&CODES Actual airflow: 1100 cfm Output capacity: 95000 Btuh 87% of load Temp. rise: 50 °F 315.10-1-61 RC-0223-2019 Cerrone Builders Inc 4 Apres Cir, Lot 25 SFD w/gas FP 1714 s.f., Gar. 450 s.f. Meets are all requirements of ACCA Manual S. 2019-Apr-17 09:46:06 wrightsoft° Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCN ...t.langeworthy\Documents\York\4 APRES CIRCLE.rup Cale=MJ7 Front Door faces: N t Residential Plans Examiner Review Form RPER1 ACCk® for HVAC System Design (Loads, Equipment, Ducts) 15Mar09 Ararcifcniig Catacias rIA....La QUEENSBURY Header Information Contractor: CERRONE BUILDERS REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ❑ No ❑ Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes 0 No OEM performance data(heating,cooling,blower): Yes Ei No ❑ Building plan#: 1434 Manual D Friction Rate Worksheet: Yes l] No 0 Duct distribution sketch: Yes ❑ No ❑ Home address(Street or Lot#,Block,Subdivision): , Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: -4 °F Orientation: Front Door faces North Indoor temperature: 68 °F North,East,west,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 109578 Btuh Number of bedrooms: 2 Conditioned floor area: 5010 ft' Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof Grains difference: 27 gr/Ib t'p�0% RH Eave overhang depth: 0 ft Sensible heat gain: 26651 Btuh Internal shade: none Eave Latent heat gain: 6130 Btuh Blinds,drapes,etc. Depth Window Total heat gain: 32781 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Euipment tye: Gas furnace Equipment type: Split AC Heating cfm: 1100 Furnace,Heatpump,Boiler,etc. it onditioner,Heat pump,etc. Cooling cfm: 1100 Model: York Model: York Static pressure: 0 in H2O TM9X100C16MP11 TCHD36S41S3 Fan's rated extemal static pressure for design airflow Heating output capacity:_ 9500 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at winter design outdoorconditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 1100 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal Friction Rate=ASP=(TEL x 100) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County,Town Municipality orAuthority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist +f F wrightsofr Right-Suite®Universal 2017 17.0.16 RSU25116 Project SummaryJob: 4 APRES CIRCLE Entire House Byte: Apr 17,2019 By: CERRONE BUILDERS Plan: 1434 QUEENSBURY,NY 12804 Pro'ect Incformation _ _- For: CERRONE BUILDERS Notes: Desi• n lnformation_ _ -` Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 103085 Btuh Structure 22868 Btuh Ducts 6493 Btuh Ducts 1119 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Bl (none) 0 Btuh Piping 0 Btuh Equipment load 109578 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 21588 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 5517 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 5010 5010 Equipment latent load 5517 Btuh Volume(ft3) 45090 45090 Air changes/hour 0.90 0.40 Equipment total load 27105 Btuh Equiv.AVF (cfm) 676 301 Req. total capacity at 0.70 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade HORIZONTAL DISCHARGE Model TM9X100C16MP11 Cond TCHD36S41S3 AHRI ref 2008692 Coil FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1 AHRI ref 3743636 Efficiency 95.5AFUE Efficiency 12.0 EER, 14.1 SEER Heating input 100000 Btuh Sensible cooling 23100 Btuh Heating output 95000 Btuh Latent cooling 9900 Btuh Temperature rise 79 °F Total cooling 33000 Btuh Actual air flow 1100 cfm Actual air flow 1100 cfm Air flow factor 0.010 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2019-Apr-17 09:46:06 wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCP. ...t.langeworthy\Documents\York14 APRES CIRCLE.rup Calc=MJ7 Front Door faces: N Right-J®Worksheet Job: 4 APRES CIRCLE Entire House Date: Apr 17,2019 By: CERRONE BUILDERS Plan: 1434 QUEENSBURY, NY 12804 MANUAL J:7th Ed. 1 Name of room Entire House Room1 Room2 Room3 2 Length of exposed wall 582.0 ft 194.0 ft 27.0 ft 57.0 ft 3 Room dimensions 1.0 x 1670 ft 1.0 x 186.0 ft 1.0 x 786.0 ft 4 Ceilings Condit.Option 9.0 ft d 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 5238 **** **** 1746 **** **** 243 **** **** 513 **** **** Exposed b 0 0 mill **** **** IIIIII **** **** 111111 **** **** IIIIII **** **** walls and c 0 0 Ili'II **** **** mill **** **** IIIIII **** **** win **** **** partitions d 0 0 111111 **** **** I11111 **** **** 111111 **** **** I I I I I I **** **** e 0 0 IIIIII **** **** 111111 **** **** Him **** **** IIIIII **** **** f 0 0 will **** **** IIIIII **** *** IIIIII **** mill 6 Windows and a 3A0 39.7 ** 235 9323 **** 0 0 **** 30 1190 **** 105 4166 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 `*** 0 0 *'** f 0 ** 0 0 **** 0 0 *''* 0 0 **** 0 0 **** 7 Windows and North 19.0 75 **** 1425 0 **** 0 0 **** 0 55 **** 1045 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 100 **** 6800 0 **** 0 30 **** 2040 15 **** 1020 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 60 **** 2040 0 **** 0 0 **** 0 35 **** 1190 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 84 2782 526 0 0 0 0 0 0 63 2087 394 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 4919 26563 5017 1746 9428 1781 213 1150 217 345 1863 352 exposed b 0 0 unn 0 0 111111 0 0 111111 0 0 111111 0 0 walls and c 0 0 mill 0 0 111111 0 0 111111 0 0 111111 0 0 partitions d 0 0 mill 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 mill 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 3345 7948 3753 1670 3968 1874 186 442 209 786 1868 882 b 0 0 Hull 0 0 IIIIII 0 0 1111n 0 0 111111 0 0 c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 d 0 0 HMI 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 null 0 0 IIIIII 0 0 111111 0 0 111111 0 0 f 0 0 mill 0 0 min 0 0 win 0 0 111111 0 0 11 Floors a 1910 1.7 0 1670 2886 0 0 0 0 0 0 0 0 0 0 (Note:room b 1910 1.7 0 10 17 0 5 9 0 0 0 0 0 0 0 perimeter c 0 0 III!!! 0 0 min 0 0 min 0 0 IIIIII 0 0 is displ. d 0 0 null 0 0 111111 0 0 111111 0 0 111111 0 0 for slab e 0 0 will 0 0 111111 0 0 111111 0 0 111111 0 0 floors) f 0 0 lull! 0 0 min 0 0 111111 0 0 111111 0 0 12 Infiltration a 168 10.4 319 53567 3307 0 0 0 30 5038 311 168 28211 1741 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 103085 **** **** 13405 **** **** 7820 **** **** 38193 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 6493 **** 6% 844 "*** 6% 493 **** 6% 2406 **** 15 Total loss=13+14 **** 109578 **** **** 14249 **** **** 8312 **** **** 40599 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 22868 **** **** 3655 **** **** 2777 **** **** 6624 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 1119 5% **** 179 5% **** 136 5% **** 324 19 Total RSH gain=(17+18)*PLF 1.00 **** 23986 1.00 **** 3833 1.00 **** 2913 1.00 **** 6948 20 Air required(cfm) 1100 1100 143 176 83 134 408 319 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wr- htsoft® 2019-Apr-17 09:46:06 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 /CCN ...t.langeworthy\Documents\York\4 APRES CIRCLE.rup Calc=MJ7 Front Door faces: N Right-J®Worksheet Job: 4 APRES CIRCLE Entire House Date: Apr 17,2019 CERRONE BUILDERS Plan: 1434 QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Room4 Room5 Room6 Room7 2 Length of exposed wall 9.0 ft 16.0 ft 21.0 ft 23.0 ft 3 Room dimensions 9.0 x 9.0 ft 9.0 x 7.0 ft 11.0 x 15.0 ft 1.0 x 162.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 81 **** **** 144 **** **** 189 **** **** 207 **** **** Exposed b 0 0 Illlll **** **** 11I111 **** **** mill **** **** Him **** **** walls and c 0 0 111111 **** **** 111111 **** **** 111111 **** **** I11III **** **** partitions d 0 0 111111 **** **** null **** **** ill!II **** **** IIIIII **** **** e 0 0 111111 **** **** 111111 **** **** 111111 **** **** 111111 **** **** f _.. 0 0 .111111 **** """. Illlll **** ****. Illlll..__****. **** ..._.IIIIII **** **** _.. 6 Windows and a 3A0 39.7 ** 0 0 **** 10 397 **'* 0 0 **** 20 793 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 20 **** 380 glass doors NE/NW 0 0 **** 0 0 **** 0 0 '*** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 10 **** 680 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 0 0 0 21 696 131 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 81 437 83 134 724 137 168 907 171 187 1010 191 exposed b 0 0 111111 0 0 1 1 1111 0 0 111111 1111110 0 111111 0 0 walls and c 0 0 partitions d 0 0 mill 0 0 111111 0 0 111111 0 0 111111 0 0 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 f 0 0 111111 0 0 Illlll 0 0 IIIIII 0 0 0 0 IIIIII 0 0 10 Ceilings a 16G0 2.4 1.1 81 192 91 63 150 71 165 392 185 162 385 182 b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 d 0 0 111111 0 0 111111 0 0 1111110 0 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 111111 0 0 Illlll f 0 0 IIIIII 0 0 1111110 0 0 0 111111 0 0 Illln 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 1910 1.7 0 0 0 0 0 0 0 5 9 0 0 0 0 perimeter c 0 0 Illlll 0 0 111111 0 0 111111 is displ. d 0 0 111111 0 0 111111 0 0 111111 0 0 for slab e 0 0 1111110 0 111111 0 0 111111 0 0 0 0 111111 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 12 Infiltration a 168 10.4 0 0 0 10 1679 104 21 3526 218 20 3358 207 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 630 **** **** 2949 **** **** 5530 **** **** 5547 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 40 **** 6% 186 **** 6% 348 **** 6% 349 **** 15 Total loss=13+14 **** 670 **** **** 3135 **** **** 5878 **** **** 5896 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 174 **** **** 991 **** **** 706 **** **** 960 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 8 5% **** 48 5% **** 35 5% **** 47 19 Total RSH gain=(17+18)*PLF 1.00 **** 182 1.00 **** 1039 1.00 **** 740 1.00 **** 1007 20 Air required(cfm) 7 8 31 48 59 34 59 46 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrightsoft* 2019-Apr-17 09:46:06 4CCP Right-Suite®Universal 2017 17.0.16 RSU25116 Page 2 ..t.langeworthy\Documents\York\4 APRES CIRCLE.rup Calc=MJ7 Front Door faces: N r Right-J®Worksheet Job: 4 APRES CIRCLE Entire House Date: Apr 17,2019 By: CERRONE BUILDERS Pan: 1434 QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Room8 Room9 Room10 2 Length of exposed wall 9.0 ft 32.0 ft 194.0 ft 3 Room dimensions 5.0 x 9.0 ft 13.0 x 14.0 ft 1.0 x 1670 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg Htg Clg 5 Gross a 12E3 5.4 1.0 81 **** **** 288 **** **** 1746 **** **** **** **** Exposed b 0 0 1 1 1 11l **** **** - jinn **** **** 111111 **** **** **** **** walls and c 0 0 111l 1 1 **** **** l um m **** **** 111111 **** **** **** **** partitions d 0 0 lllllt **** **** cum **** **** lllllt **** **** **** **** e 0 0 111111 **** **** i l l l l l **** **** min **** **** **** **** f 0_......0 IIllll **** **** Illll1. **** ****. 11llll __.**** **** ........ **** **** _... 6 Windows and a 3A0 39.7 ** 10 397 **** 25 992 **** 35 1389 **** **** glass doors b 0 ** 0 0 **`* 0 0 **** 0 0 **** **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** **** d 0 ** 0 0 **** 0 0 **** 0 0 **** **** e 0 ** 0 0 **** 0 0 **** 0 0 **** **** f 0 ** 0 0 **** 0 0 **** 0 0 **** **** 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 **** glass doors NE/NW 0 0 **** 0 0 **** 0 0 `*** 0 **** Cooling E/W 68.0 10 **** 680 0 **** 0 35 **** 2380 **** SE/SW 0 0 **** 0 0 **** 0 0 **** 0 **** South 34.0 0 **** 0 25 **** 850 0 **** 0 **** Horz 0 0 **** 0 0 **** 0 0 **** 0 **** 8 Other doors a 10D0 33.1 6.3 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 71 383 72 263 1420 268 1711 9239 1745 exposed b 0 0 111111 0 0 nnn 0 0 min 0 0 walls and c 0 0 111111 0 0 111111 0 0 lllllt 0 0 partitions d 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 lllllt 0 0 f 0 0 lllllt 0 0 111111 0 0 lllllt 0 0 10 Ceilings a 16G0 2.4 1.1 45 107 50 182 432 204 5 12 6 b 0 0 111111 0 0 111111 0 0 111111 0 0 c 0 0 lllllt 0 0 111111 0 0 lllllt 0 0 d 0 0 111111 0 0 min 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 lllllt 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 1670 2886 0 (Note:room b 1910 1.7 0 0 0 0 0 0 0 0 0 0 perimeter c 0 0 111111 0 0 111111 0 0 lllllt 0 0 is displ. d 0 0 111111 0 0 111111 0 0 lllllt 0 0 for slab e 0 0 111111 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 111111 0 0 111111 0 0 12 Infiltration a 168 10.4 10 1679 104 25 4198 259 35 5877 363 Ventilation 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 2566 **** **** 7042 **** **** 19403 **** **** **** Less extemal heating **** 0 **** **** 0 **** **** 0 **** **** **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** **** 14 Duct loss 6% 162 **** 6% 444 **** 6% 1299 **** **** 15 Total loss=13+14 **** 2728 **** **** 7486 **** **** 20625 **** **** **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 **** Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 **** 17 Subtot RSH gain=7+8..+12+16 **** **** 907 **** **** 1582 **** **** 4494 **** **** Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 18 Duct gain 5% **** 44 5% **** 77 5% **** 220 **** 19 Total RSH gain=(17+18)*PLF 1.00 **** 951 1.00 **** 1659 1.00 **** 4713 **** 20 Air required(cfm) 27 44 75 76 207 216 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2019-Apr-17 09:46:06 wrightSOft°° Right-Suite®Universal 2017 17.0.16 RSU25116 Page 3 ACC1* ...t.langeworthy\Documents\York\4 APRES CIRCLE.rup Calc=MJ7 Front Door faces: N