inspection 06072019INSPECTION WORKSHEET (BINS-003359-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0223-2019Case Module:Permit Inspection Date:Fri Jun 7, 2019Inspection Status:Passed Inspector:Charles DyerInspection Type:Building Foundation Job Address:4 APRES CIRParcel Number:315.10-1-61 Queensbury, NY 12804 Contact TypeCompany NameName ApplicantCERRONE BUILDERS, INC. Granted PermissionCERRONE BUILDERS, INC. Primary OwnerCERRONE BUILDERS, INC. ContractorCERRONE BUILDERS, INC. Checklist ItemPassedComments Building Inspector NotesNO5/28/19 footings approved. FootingsYES5/28/19 footings approved PiersNO Monolithic SlabNO Reinforcement in PlaceYES2 rows of #4 rebar continuous Verticals to be wet set Reinforcement in PlaceYESWith 3 rows # 4 Foundation WaterproofingNO Jun 07, 2019Page (1) INSPECTION WORKSHEET (BINS-003359-2019) Checklist ItemPassedComments Footing Drain Daylight or SumpNO Footing Drain Stone - 12 inch widthNO Footing Drain Stone - 6 inches above footingNO Footing Drain stone - 6 mil polyNO Backfill ApprovalYES6/4/19 Plumbing Under SlabNO PVC / Cast / CopperNO Foundation Insulation Interior / ExteriorNO Rough Grade 6 inch drop within 10 ft.NO Poly Under SlabYES6/7/19 approved Dyer, Charles (Inspector) Jun 07, 2019Page (2)